Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 30(Pt 6): 1168-1182, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37860937

RESUMO

The Femtosecond X-ray Experiments (FXE) instrument at the European X-ray Free-Electron Laser (EuXFEL) provides an optimized platform for investigations of ultrafast physical, chemical and biological processes. It operates in the energy range 4.7-20 keV accommodating flexible and versatile environments for a wide range of samples using diverse ultrafast X-ray spectroscopic, scattering and diffraction techniques. FXE is particularly suitable for experiments taking advantage of the sub-MHz repetition rates provided by the EuXFEL. In this paper a dedicated setup for studies on ultrafast biological and chemical dynamics in solution phase at sub-MHz rates at FXE is presented. Particular emphasis on the different liquid jet sample delivery options and their performance is given. Our portfolio of high-speed jets compatible with sub-MHz experiments includes cylindrical jets, gas dynamic virtual nozzles and flat jets. The capability to perform multi-color X-ray emission spectroscopy (XES) experiments is illustrated by a set of measurements using the dispersive X-ray spectrometer in von Hamos geometry. Static XES data collected using a multi-crystal scanning Johann-type spectrometer are also presented. A few examples of experimental results on ultrafast time-resolved X-ray emission spectroscopy and wide-angle X-ray scattering at sub-MHz pulse repetition rates are given.

2.
Rev Sci Instrum ; 87(5): 053116, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27250401

RESUMO

We report about the development and implementation of a new setup for time-resolved X-ray absorption fine structure spectroscopy at beamline P11 utilizing the outstanding source properties of the low-emittance PETRA III synchrotron storage ring in Hamburg. Using a high intensity micrometer-sized X-ray beam in combination with two positional feedback systems, measurements were performed on the transition metal complex fac-Tris[2-phenylpyridinato-C2,N]iridium(III) also referred to as fac-Ir(ppy)3. This compound is a representative of the phosphorescent iridium(III) complexes, which play an important role in organic light emitting diode (OLED) technology. The experiment could directly prove the anticipated photoinduced charge transfer reaction. Our results further reveal that the temporal resolution of the experiment is limited by the PETRA III X-ray bunch length of ∼103 ps full width at half maximum (FWHM).

3.
Faraday Discuss ; 171: 169-78, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25415532

RESUMO

We have studied the photoinduced low spin (LS) to high spin (HS) conversion of aqueous Fe(bpy)3 with pulse-limited time resolution. In a combined setup permitting simultaneous X-ray diffuse scattering (XDS) and spectroscopic measurements at a MHz repetition rate we have unraveled the interplay between intramolecular dynamics and the intermolecular caging solvent response with 100 ps time resolution. On this time scale the ultrafast spin transition including intramolecular geometric structure changes as well as the concomitant bulk solvent heating process due to energy dissipation from the excited HS molecule are long completed. The heating is nevertheless observed to further increase due to the excess energy between HS and LS states released on a subnanosecond time scale. The analysis of the spectroscopic data allows precise determination of the excited population which efficiently reduces the number of free parameters in the XDS analysis, and both combined permit extraction of information about the structural dynamics of the first solvation shell.

4.
J Phys Chem A ; 116(40): 9878-87, 2012 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-22970732

RESUMO

We have studied the photoinduced low spin (LS) to high spin (HS) conversion of [Fe(bipy)(3)](2+) in aqueous solution. In a laser pump/X-ray probe synchrotron setup permitting simultaneous, time-resolved X-ray diffuse scattering (XDS) and X-ray spectroscopic measurements at a 3.26 MHz repetition rate, we observed the interplay between intramolecular dynamics and the intermolecular caging solvent response with better than 100 ps time resolution. On this time scale, the initial ultrafast spin transition and the associated intramolecular geometric structure changes are long completed, as is the solvent heating due to the initial energy dissipation from the excited HS molecule. Combining information from X-ray emission spectroscopy and scattering, the excitation fraction as well as the temperature and density changes of the solvent can be closely followed on the subnanosecond time scale of the HS lifetime, allowing the detection of an ultrafast change in bulk solvent density. An analysis approach directly utilizing the spectroscopic data in the XDS analysis effectively reduces the number of free parameters, and both combined permit extraction of information about the ultrafast structural dynamics of the caging solvent, in particular, a decrease in the number of water molecules in the first solvation shell is inferred, as predicted by recent theoretical work.


Assuntos
Compostos Férricos/química , Teoria Quântica , Termodinâmica , Cinética , Processos Fotoquímicos , Espectrometria por Raios X , Fatores de Tempo , Água/química , Difração de Raios X
5.
Opt Express ; 17(23): 20853-9, 2009 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-19997320

RESUMO

We have used a low repetition rate (1 kHz), femtosecond laser amplifier in combination with a spatial light modulator (SLM) to write optical waveguides with controllable cross-section inside a phosphate glass sample. The SLM is used to induce a controllable amount of astigmatism in the beam wavefront while the beam ellipticity is controlled through the propagation distance from the SLM to the focusing optics of the writing set-up. The beam astigmatism leads to the formation of two separate disk-shaped foci lying in orthogonal planes. Additionally, the ellipticity has the effect of enabling control over the relative peak irradiances of the two foci, making it possible to bring the peak irradiance of one of them below the material transformation threshold. This allows producing a single waveguide with controllable cross-section. Numerical simulations of the irradiance distribution at the focal region under different beam shaping conditions are compared to in situ obtained experimental plasma emission images and structures produced inside the glass, leading to a very satisfactory agreement. Finally, guiding structures with controllable cross-section are successfully produced in the phosphate glass using this approach.


Assuntos
Lasers , Óptica e Fotônica/métodos , Amplificadores Eletrônicos , Desenho de Equipamento , Vidro , Luz , Modelos Teóricos , Fosfatos/química , Refratometria/instrumentação , Espalhamento de Radiação
6.
J Chem Phys ; 130(12): 124520, 2009 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-19334864

RESUMO

We present a novel analysis of time-resolved extended x-ray absorption fine structure (EXAFS) spectra based on the fitting of the experimental transients obtained from optical pump/x-ray probe experiments. We apply it to the analysis of picosecond EXAFS data on aqueous [Fe(II)(bpy)(3)](2+), which undergoes a light induced conversion from its low-spin (LS) ground state to the short-lived (tau approximately 650 ps) excited high-spin (HS) state. A series of EXAFS spectra were simulated for a collection of possible HS structures from which the ground state fit spectrum was subtracted to generate transient difference absorption (TA) spectra. These are then compared with the experimental TA spectrum using a least-squares statistical analysis to derive the structural change. This approach reduces the number of required parameters by cancellation in the differences. It also delivers a unique solution for both the fractional population and the extracted excited state structure. We thus obtain a value of the Fe-N bond elongation in the HS state with subpicometer precision (0.203+/-0.008 A).


Assuntos
Compostos Ferrosos/química , Absorção , Análise Espectral , Fatores de Tempo , Água/química , Raios X
7.
Science ; 323(5913): 489-92, 2009 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-19074309

RESUMO

X-ray absorption spectroscopy is a powerful probe of molecular structure, but it has previously been too slow to track the earliest dynamics after photoexcitation. We investigated the ultrafast formation of the lowest quintet state of aqueous iron(II) tris(bipyridine) upon excitation of the singlet metal-to-ligand-charge-transfer (1MLCT) state by femtosecond optical pump/x-ray probe techniques based on x-ray absorption near-edge structure (XANES). By recording the intensity of a characteristic XANES feature as a function of laser pump/x-ray probe time delay, we find that the quintet state is populated in about 150 femtoseconds. The quintet state is further evidenced by its full XANES spectrum recorded at a 300-femtosecond time delay. These results resolve a long-standing issue about the population mechanism of quintet states in iron(II)-based complexes, which we identify as a simple 1MLCT-->3MLCT-->5T cascade from the initially excited state. The time scale of the 3MLCT-->5T relaxation corresponds to the period of the iron-nitrogen stretch vibration.

8.
J Phys Chem B ; 110(51): 26497-505, 2006 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-17181311

RESUMO

We report a femtosecond pump-probe study on the photochemistry of concentrated aqueous solutions of [RuII(bpy)3]2+, as a function of pump power (up to 2 TW/cm2) at 400 nm excitation. The transient absorption spectra in the 345-660 nm range up to 1 ns time delay enable the observation of the following photoproducts: the triplet 3MLCT (metal-to-ligand-charge-transfer) excited state, the reduced form [RuII(bpy)3]+, the oxidized species [RuIII(bpy)3]3+, and the solvated electron e(aq). The 3MLCT state is formed within the excitation pulse and undergoes vibrational relaxation in 3-5 ps, as evidenced by the shift of the ligand-centered (LC) absorption band below 400 nm. Even at the highest pump powers, the majority of e(aq) originates from multiphoton ionization of [RuII(bpy)3]2+ and not from the solvent, generating [RuIII(bpy)3]3+ as a byproduct. At 10 ps time delay, the total concentration of the three product species is balanced by the depleted concentration of [RuII(bpy)3]2+, even at the highest fluences used, indicating that no further reaction products significantly contribute to the overall photochemistry. On the 100 ps time scale, most probably diffusion-controlled reduction of ground-state [RuII(bpy)3]2+ by solvated electrons occurs, next to recombination between e(aq) and [RuIII(bpy)3]3+.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...