Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 544
Filtrar
1.
BMJ Open ; 14(6): e078358, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926145

RESUMO

INTRODUCTION: The treatment of patients with cardiogenic shock (CS) encompasses several health technologies including Impella pumps and venoarterial extracorporeal membrane oxygenation (VA-ECMO). However, while they are widely used in clinical practice, information on resource use and quality of life (QoL) associated with these devices is scarce. The aim of this study is, therefore, to collect and comparatively assess clinical and socioeconomic data of Impella versus VA-ECMO for the treatment of patients with severe CS, to ultimately conduct both a cost-effectiveness (CEA) and budget impact (BIA) analyses. METHODS AND ANALYSIS: This is a prospective plus retrospective, multicentre study conducted under the scientific coordination of the Center for Research on Health and Social Care Management of SDA Bocconi School of Management and clinical coordination of Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) San Raffaele Scientific Institute in Milan. The Impella Network stemmed for the purposes of this study and comprises 17 Italian clinical centres from Northern to Southern Regions in Italy. The Italian network qualifies as a subgroup of the international Impella Cardiac Surgery Registry. Patients with CS treated with Impella pumps (CP, 5.0 or 5.5) will be prospectively recruited, and information on clinical outcomes, resource use and QoL collected. Economic data will be retrospectively matched with data from comparable patients treated with VA-ECMO. Both CEA and BIA will be conducted adopting the societal perspective in Italy. This study will contribute to generate new socioeconomic evidence to inform future coverage decisions. ETHICS AND DISSEMINATION: As of May 2024, most of the clinical centres submitted the documentation to their ethical committee (N=13; 76%), six centres received ethical approval and two centres started to enrol patients. Study results will be published in peer-reviewed publications and disseminated through conference presentations.


Assuntos
Análise Custo-Benefício , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/economia , Oxigenação por Membrana Extracorpórea/economia , Oxigenação por Membrana Extracorpórea/métodos , Coração Auxiliar/economia , Estudos Prospectivos , Estudos Retrospectivos , Itália , Qualidade de Vida , Estudos Multicêntricos como Assunto , Orçamentos , Estudos Observacionais como Assunto
2.
J Clin Med ; 13(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38892916

RESUMO

Current guidelines for the care of heart transplantation recipients recommend routine endomyocardial biopsy and invasive coronary angiography as the cornerstones in the surveillance for acute rejection (AR) and coronary allograft vasculopathy (CAV). Non-invasive tools, including coronary computed tomography angiography and cardiac magnetic resonance, have been introduced into guidelines without roles of their own as gold standards. These techniques also carry the risk of contrast-related kidney injury. There is a need to explore non-invasive approaches providing valuable information while minimizing risks and allowing their application independently of patient comorbidities. Echocardiographic examination can be performed at bedside, serially repeated, and does not carry the burden of contrast-related kidney injury and procedure-related risk. It provides comprehensive assessment of cardiac morphology and function. Advanced echocardiography techniques, including Doppler tissue imaging and strain imaging, may be sensitive tools for the detection of minor myocardial dysfunction, thus providing insight into early detection of AR and CAV. Stress echocardiography may offer a valuable tool in the detection of CAV, while the assessment of coronary flow reserve can unravel coronary microvascular impairment and add prognostic value to conventional stress echocardiography. The review highlights the role of Doppler echocardiography in heart transplantation follow-up, weighting advantages and limitations of the different techniques.

3.
Medicina (Kaunas) ; 60(6)2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38929496

RESUMO

Background and Objectives: Determinants of long-term outcomes after surgery for native mitral valve endocarditis have not been thoroughly investigated. The aim of this study was to assess anatomical, disease, and surgical risk factors for long-term mortality and need of reintervention, in patients undergoing mitral valve surgery for active endocarditis. Materials and Methods: Patients who underwent surgery for active native mitral valve endocarditis at three academic centres, between 2000 and 2022, were analysed. The primary outcome was long-term survival. The secondary outcome was the freedom from mitral reoperation. Survival curves were constructed with Kaplan-Meier methodology. Multivariable Cox regression was used to identify demographic, anatomical, disease, and surgical factors associated with late mortality and reoperation. Results: 335 consecutive patients with active mitral endocarditis were analysed. Two hundred and one patients (70.5%) had infection confined to the valve cusp whereas 89 (25.6%) had invasive disease extended to the annulus and surrounding tissues. Preoperative neurological events occurred at the diagnosis in 52 cases. Streptococci were the most common causative organisms followed by Staphylococcus aureus, Coagulase-negative Staphylococcus, and Enterococcus. Valve repair was performed in 108 patients (32.2%). Survival at 5 and 10 years was 70.1% and 59.2%, respectively. Staphylococcus emerged as an independent predictor of late mortality, along with age, chronic obstructive pulmonary disease, and previous cardiac surgery. Survival was considerably reduced in patients with S. aureus compared with those without (log rank p < 0.001). The type of surgery (repair vs. replacement) did not emerge as a risk factor for late mortality and reoperation. Seventeen patients underwent mitral reoperation during the follow-up. The 5- and 10-year freedom from reoperation was 94.7% and 91.8%, respectively. Conclusions: Active mitral valve endocarditis remains a life-threatening disease with impaired survival. While lesion characteristics influenced surgical decision-making and intraoperative management, their impact on long-term survival and freedom from reintervention appears to be moderated by other factors such as infecting pathogens and patient comorbidities.


Assuntos
Valva Mitral , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Idoso , Reoperação/estatística & dados numéricos , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos , Endocardite/cirurgia , Endocardite/mortalidade , Adulto , Modelos de Riscos Proporcionais , Estimativa de Kaplan-Meier
4.
J Clin Med ; 13(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731152

RESUMO

Background: Heart failure (HF)-related mortality has been exacerbated by the COVID-19 pandemic; however, it is unclear how healthcare reassessment has contributed to the excess mortality versus SARS-CoV-2 infection itself. We aimed to assess how the pandemic affected the therapeutic management and prognosis of HF patients. Methods: We retrospectively reviewed the healthcare utilization databases of the Lombardy region (Italy) to identify all newly-diagnosed HF patients from January 2018 to December 2021. Outcomes were the utilization of HF therapies (Sacubitril/Valsartan; cardiac resynchronization therapy [CRT] and/or implantable cardioverter-defibrillator [ICD]; mechanical circulatory support [MCS]; heart transplantation [HTX]) and mortality. Cox regression models were fitted to estimate the hazard ratios (HR) and 95% confidence intervals (CI) for outcomes associated with the pandemic. Results: 36,130 and 17,263 patients were identified in the pre-pandemic and pandemic eras, respectively. The pandemic reduced Sacubitril/Valsartan utilization (HR = 0.77, 95% CI: 0.65-0.91) and CRT/ICD implantation (HR = 0.85, 95% CI: 0.78-0.92), but not MCS (HR = 1.11, 95% CI: 0.86-1.43) and HTX (HR = 0.88, 95% CI: 0.70-1.09). An increased mortality risk was observed during the pandemic (HR = 1.19, 95% CI: 1.15-1.23), which was attributable to SARS-CoV-2 infection (HR for non-COVID-19-related mortality = 1.01, 95% CI: 0.97-1.04). Conclusions: The COVID-19 pandemic was associated with a reduction in medical and interventional therapies for HF and an increase in mortality for HF patients.

5.
Bioengineering (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790303

RESUMO

The production of biomedical devices able to appropriately interact with the biological environment is still a great challenge. Synthetic materials are often employed, but they fail to replicate the biological and functional properties of native tissues, leading to a variety of adverse effects. Several commercial products are based on chemically treated xenogeneic tissues: their principal drawback is due to weak mechanical stability and low durability. Recently, decellularization has been proposed to bypass the drawbacks of both synthetic and biological materials. Acellular materials can integrate with host tissues avoiding/mitigating any foreign body response, but they often lack sufficient patency and impermeability. The present paper investigates an innovative approach to the realization of hybrid materials that combine decellularized bovine pericardium with polycarbonate urethanes. These hybrid materials benefit from the superior biocompatibility of the biological tissue and the mechanical properties of the synthetic polymers. They were assessed from physicochemical, structural, mechanical, and biological points of view; their ability to promote cell growth was also investigated. The decellularized pericardium and the polymer appeared to well adhere to each other, and the two sides were distinguishable. The maximum elongation of hybrid materials was mainly affected by the pericardium, which allows for lower elongation than the polymer; this latter, in turn, influenced the maximum strength achieved. The results confirmed the promising features of hybrid materials for the production of vascular grafts able to be repopulated by circulating cells, thus, improving blood compatibility.

6.
Transplantation ; 108(7): e106-e109, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38750639

RESUMO

BACKGROUND: Withdrawal of life-sustaining therapy (WLST) performed in the circulatory determination of death (DCD) donors leads to cardiac arrest, challenging the utilization of the myocardium for transplantation. The rapid initiation of normothermic regional perfusion or extracorporeal membrane oxygenation after death helps to optimize organs before implantation. However, additional strategies to mitigate the effects of stress response during WLST, hypoxic/ischemic injury, and reperfusion injury are required to allow myocardium recovery. METHODS: To this aim, our team routinely used a preconditioning protocol for each DCD donation before and during the WLST and after normothermic regional perfusion/extracorporeal membrane oxygenation. The protocol includes pharmacological treatments combined to reduce oxidative stress (melatonin, N -acetylcysteine, and ascorbic acid), improve microcirculation (statins), and mitigate organ's ischemic injury (steroids) and organ ischemia/reperfusion injury (remifentanil and sevoflurane when the heart is available for transplantation). RESULTS: This report presents the first case of recovery of cardiac function, with the only support of normothermic regional reperfusion, following 20 min of a no-touch period and 41 min of functional warm ischemic time in a DCD donor after the preconditioning protocol. CONCLUSIONS: Our protocol seems to be effective in abolishing the stress response during WLST and, on the other hand, particularly organ protective (and heart protective), giving a chance to donate organs less impaired from ischemia/reperfusion injury.


Assuntos
Oxigenação por Membrana Extracorpórea , Recuperação de Função Fisiológica , Humanos , Masculino , Doadores de Tecidos , Transplante de Coração , Fatores de Tempo , Perfusão/métodos , Resultado do Tratamento , Estresse Oxidativo , Morte , Pessoa de Meia-Idade , Adulto , Isquemia Quente/efeitos adversos
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38485695

RESUMO

Endovascular aortic arch repair (Ar-TEVAR) with single-branch, off-the-shelf Nexus aortic arch system has shown promising early and 3-year outcomes. There is lack of data regarding long-term results of this specific device, particularly regarding patency of supra-aortic bypasses and stability of the connection between the 2 modules. This case report describes 6-year clinical and imaging follow-up of a 74-year-old patient who underwent Ar-TEVAR with Nexus. Over 6 years, the patient experienced minor complications unrelated to the device. The patency of supra-aortic bypasses and integrity of the device's connection were confirmed. Computed tomography angiography constantly showed exclusion of the aneurysm and reduction of the aneurysmal sac. In conclusion, although extended research and broader data are needed, this case provides encouraging evidence of long-term results of Ar-TEVAR with Nexus.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Idoso , Prótese Vascular , Angiografia por Tomografia Computadorizada , Implante de Prótese Vascular/métodos , Stents , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Seguimentos , Resultado do Tratamento , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Estudos Retrospectivos
9.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38317061

RESUMO

Patients with aortic arch pathologies after surgery for type-A acute aortic dissection represent a challenging population since open surgery is associated with a non-negligible rate of mortality and complications. Microinvasive endovascular aortic arch repair Arch-Thoracic EndoVascular Aortic Repair (Ar-TEVAR) has shown promising results in high-risk patients. Ar-TEVAR is usually performed under general anaesthesia. We report the case of an 83-year-old man with a history of ascending aorta replacement for type-A acute aortic dissection who was referred for an anastomotic pseudoaneurysm. Ar-TEVAR using an off-the-shelf single-branch aortic arch stent graft was chosen. In order to further minimize procedural invasiveness, monitored anaesthesia care (local anaesthesia with sedation and analgesia) was performed since it provides less stress on the cardiovascular and respiratory systems and overall leads to a faster recovery especially in elderly patients.


Assuntos
Anestesia , Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/cirurgia , Prótese Vascular , Correção Endovascular de Aneurisma , Aneurisma da Aorta Torácica/cirurgia , Stents , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Estudos Retrospectivos
10.
ASAIO J ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334806

RESUMO

A 45 year old male obese patient with a previous history of repaired congenital heart disease developed worsening heart failure making heart transplantation listing mandatory. Unfortunately, due to his anthropometric measures, the search for a suitable brain-dead donor was unsuccessful. For this reason, he accepted to be enrolled in the controlled donation after circulatory death (cDCD) program. According to the Italian Law regulating death declaration after cardiac arrest (no-touch period of 20 minutes-one of the longest in the world), we faced a 34 minute cardiac asystole, after which the heart was recovered through a thoraco-abdominal normothermic regional perfusion excluding the epiaortic vessels. The heart was then preserved by means of cold static storage. Heart transplantation was performed successfully without any signs of primary graft failure. Postoperative endomyocardial biopsies were negative for acute cellular and antibody-mediated rejection. Furthermore, echocardiographic and cardiac magnetic resonance evaluation of the heart did not show any functional abnormalities. The patient was discharged on post-operative day (POD) #39 in good clinical conditions.

11.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
12.
Med Sci (Basel) ; 12(1)2024 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-38249082

RESUMO

Vein grafts are the most used conduits in coronary artery bypass grafting (CABG), even though many studies have suggested their lower patency compared to arterial alternatives. We have reviewed the techniques and technologies that have been investigated over the years with the aim of improving the quality of these conduits. We found that preoperative and postoperative optimal medical therapy and no-touch harvesting techniques have the strongest evidence for optimizing vein graft patency. On the other hand, the use of venous external support, endoscopic harvesting, vein preservation solution and anastomosis, and graft configuration need further investigation. We have also analyzed strategies to treat vein graft failure: when feasible, re-doing the CABG and native vessel primary coronary intervention (PCI) are the best options, followed by percutaneous procedures targeting the failed grafts.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Coração , Tecnologia
13.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38212996

RESUMO

OBJECTIVES: In the last decades, 4 different scores for the prediction of mortality following surgery for type A acute aortic dissection (TAAD) were proposed. We aimed to validate these scores in a large external multicentre cohort. METHODS: We retrospectively analysed patients who underwent surgery for TAAD between 2000 and 2020. Patients were enrolled from 10 centres from 2 European countries. Outcomes were the early (30-day and/or in-hospital) and 1-year mortality. Discrimination, calibration and observed/expected (O/E) ratio were evaluated. RESULTS: A total of 1895 patients (31.7% females, mean age 63.72 ± 12.8 years) were included in the study. Thirty-day mortality and in-hospital mortality were 21.7% (n = 412) and 22.5% (n = 427) respectively. The German Registry of Acute Aortic Dissection Type A (GERAADA) score shows to have the best discrimination [area under the curve (AUC) 0.671 and 0.672] in predicting as well the early and the 1-year mortality, followed by the International Registry of Acute Aortic Dissection (IRAD) model 1 (AUC 0.658 and 0.672), the Centofanti (AUC 0.645 and 0.66) and the UK aortic score (AUC 0.549 and 0.563). According to Hosmer-Lemeshow and Brier tests, the IRAD model I and GERAADA, respectively, were well calibrated for the early mortality, while the GERAADA and Centofanti for the 1-year mortality. The O/E analysis showed a marked underestimation for patients labelled as low-risk for UK aortic score and IRAD model I for both outcomes. CONCLUSIONS: The GERAADA score showed the best performance in comparison with other scores. However, none of them achieved together a fair discrimination and a good calibration for predicting either the early or the 1-year mortality.


Assuntos
Dissecção Aórtica , Azidas , Desoxiglucose/análogos & derivados , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Mortalidade Hospitalar , Europa (Continente) , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
14.
J Interv Card Electrophysiol ; 67(1): 175-182, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37365481

RESUMO

BACKGROUND: The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations. METHODS: The study population comprised 6 consecutive patients (67% male; mean age 70 ± 22 years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead (n = 3) and His pacing lead (n = 3) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97 ± 90 months [range 8-193). RESULTS: Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of < 1-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred. CONCLUSIONS: Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.


Assuntos
Cardiopatias Congênitas , Marca-Passo Artificial , Humanos , Masculino , Adulto , Criança , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Remoção de Dispositivo , Cardiopatias Congênitas/cirurgia , Estimulação Cardíaca Artificial , Doença do Sistema de Condução Cardíaco
15.
J Cardiovasc Med (Hagerstown) ; 25(2): 165-172, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149703

RESUMO

AIMS: Training in congenital cardiac surgery has become more and more difficult because of the reduced opportunities for trainees in the operating room and the high patient anatomical variability. The aim of this study was to perform a pilot evaluation of surgical simulation on a simple 3D-printed heart model in training of young surgeons and its potential inclusion in the curriculum of residency programs. METHODS: A group of 11 residents performed a surgical correction of aortic coarctation using a 3D-printed surgical model. After teaching the surgical procedure, a simulation was performed twice, at different times, and was evaluated quantitatively and qualitatively by a senior surgeon. A 3D model-based training program was then developed and incorporated into our cardiac surgery training program. RESULTS: A significant improvement in surgical technique was observed between the first and second surgical simulations: median of 65% [interquartile range (IQR) = 61-70%] vs. 83% (IQR = 82-91%, P < 0.001). The median time required to run the simulation was significantly shorter during the second simulation: 39 min (IQR = 33-40) vs. 45 min (IQR = 37-48; P = 0.02). Regarding the simulation program, a basic and an advanced program were developed, including a total of 40 different simulated procedures divided into 12 sessions. CONCLUSION: Surgical simulation using 3D-printing technology can be an extremely valuable tool to improve surgical training in congenital heart disease. Our pilot study can represent the first step towards the creation of an integrated training system on 3D-printed models of congenital and acquired heart diseases in other Italian residency programs.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Internato e Residência , Humanos , Projetos Piloto , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Currículo , Competência Clínica
16.
Curr Probl Cardiol ; 49(1 Pt B): 102078, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37716536

RESUMO

Transfusions are extremely frequent after cardiac surgery, and they have a considerable economic burden and impact on outcomes. Optimal patient blood management could play a fundamental role in reducing the rate of transfusion and Jehovah's Witnesses (JW) represent the ideal surrogate study population. This meta-analysis compares outcomes of JWs and non-JWs' patients undergoing cardiac surgery, assessing the safety of a bloodless cardiac surgery. A scoping review was conducted using a search strategy for studies assessing outcomes of JW undergoing cardiac surgery. The primary outcome was perioperative mortality, and a random-effects meta-analysis was performed. Ten studies were included in our meta-analysis, involving 780 JW patients refusing any type of transfusion ("JW") and 1182 patients accepting transfusion if needed ("non-JW"). 86% of non-JW patients received at least 1 transfusion. There was no significant difference in terms of perioperative mortality (OR 0.91; 95% CI 0.55-1.52; p = 0.72). The volume blood loss was significantly less in the JW (p = 0.001), while the rate of reoperation for bleeding was also lower, but not statistically significative, in the JW (p = 0.16). Both preoperative and postoperative hemoglobin and hematocrit were significantly higher in the JW. Therefore, we concluded that bloodless cardiac surgery is safe and early outcomes are similar between JW and non-JW patients: optimal patient blood management is fundamental in guarantying these results. Further studies are needed to assess if a limitation of transfusion could have a positive long-term impact on outcomes.


Assuntos
Procedimentos Médicos e Cirúrgicos sem Sangue , Procedimentos Cirúrgicos Cardíacos , Testemunhas de Jeová , Humanos , Estudos Retrospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Transfusão de Sangue
17.
Cardiovasc Pathol ; 69: 107598, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38101526

RESUMO

Primary malignant cardiac tumors are rare and usually misdiagnosed because they can mimic more common intracardiac lesions, therefore, in clinical practice it is important to always consider even uncommon diseases in order to avoid delayed diagnosis and to plan the most appropriate therapeutic strategy in a timely fashion. We report a case of a 73-year-old man with clinical signs and imaging findings (echocardiography) suggesting infective bacterial endocarditis of the mitral valve. However, intraoperative evaluation raised suspicion that the mitral lesions had a different nature. Surgical removal of the mass was performed, and the final correct diagnosis was made through pathologic examination, revealing a mitral valve sarcoma thus allowing for the beginning of specific oncological treatment.


Assuntos
Endocardite Bacteriana , Endocardite , Masculino , Humanos , Idoso , Endocardite Bacteriana/microbiologia , Endocardite/diagnóstico , Endocardite/patologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/patologia , Ecocardiografia/métodos
18.
J Clin Med ; 12(24)2023 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-38137672

RESUMO

BACKGROUND: When heart transplantation and myocardial recovery are unlikely, patients presenting with biventricular cardiogenic shock initially treated with extracorporeal membrane oxygenation (ECMO) may benefit from a mechanical support upgrade. In this scenario, a micro-invasive approach is proposed: the combination of the double-lumen ProtekDuo cannula (Livanova, London, UK) and the Impella 5.5 (Abiomed, Danvers, MA) trans-aortic pump that translates into a hybrid BiVAD. METHODS: All consecutive ECMO patients presenting with biventricular cardiogenic shock and ineligibility to heart transplantation from August 2022 were prospectively enrolled. The clinical course, procedural details, and in-hospital events were collected via electronic medical records. RESULTS: A total of three patients, who were temporarily not eligible for heart transplantation or durable LVAD due to severe acute pneumonia and right ventricular (RV) dysfunction, were implanted with a hybrid BiVAD. This strategy provided high-flow biventricular support while pulmonary function ameliorated. Moreover, by differentially sustaining the systemic and pulmonary circulation, it allowed for a more adequate reassessment of RV function. All the patients were considered eligible for isolated durable LVAD and underwent less invasive LVAD implantation paired with a planned postoperative RVAD. In all cases, RV function gradually recovered and the RVAD was successfully removed. CONCLUSIONS: The Hybrid BiVAD represents an up-to-date micro-invasive mechanical treatment of acute biventricular failure beyond ECMO. Its rationale relies on more physiological circulation across the lungs, the complete biventricular unloading, and the possibility of including an oxygenator in the circuit. Finally, the independent and differential control of pulmonary and systemic flows allows for more accurate RV function evaluation for isolated durable LVAD eligibility reassessment.

19.
Am J Cardiol ; 209: 104-113, 2023 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-37848175

RESUMO

Although surgical ablation has been shown to produce excellent outcomes at follow-up for patients with atrial fibrillation who underwent mitral valve replacement/repair (MVR), this procedure is not commonly performed. Our objective was to conduct a systematic review and meta-analysis to evaluate the outcomes of concomitant surgical ablation during MVR. Three databases were systematically reviewed for randomized clinical trials published by August 2022. The primary outcome was sinus rhythm (SR) at 12 months. Secondary outcomes included SR at discharge and 6 months, all-cause mortality, permanent pacemaker implantation, and stroke and thromboembolic events. A random-effects meta-analysis was performed, calculating odds ratios (ORs) for each outcome. Thirteen studies were included, involving 1,089 patients comparing patients who underwent either isolated MVR ("MVR-only") or concomitant surgical ablation during MVR ("MVR+Ablation"). The odds of SR were significantly higher in the MVR+Ablation group at discharge (OR 9.62, 95% confidence interval [CI] 4.87 to 19.02, I2 = 55%), at 6-month follow-up (OR 7.21, 95% CI 4.30 to 12.11, I2 = 34%), and at 1-year follow-up (OR 8.41, 95% CI 5.14 to 13.77, I2 = 48%). All-cause mortality was not different in the groups, as were stroke and thromboembolic events, whereas the odds of permanent pacemaker implantation were slightly higher in the MVR+Ablation group (OR 1.87, 95% CI 1.11 to 3.17, I2 = 0%). Concomitant surgical ablation during MVR showed excellent outcomes at short-term follow-up, despite a slightly higher rate of permanent pacemaker implantation. Further studies with longer follow-ups are needed to assess if the SR is maintained over the years.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Valva Mitral/cirurgia , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Ablação por Cateter/métodos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/complicações , Implante de Prótese de Valva Cardíaca/métodos
20.
Diagnostics (Basel) ; 13(17)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37685356

RESUMO

Heart transplantation (HT) is the established treatment for end-stage heart failure, significantly enhancing patients' survival and quality of life. To ensure optimal outcomes, the routine monitoring of HT recipients is paramount. While existing guidelines offer guidance on a blend of invasive and non-invasive imaging techniques, certain aspects such as the timing of echocardiographic assessments and the role of echocardiography or cardiac magnetic resonance (CMR) as alternatives to serial endomyocardial biopsies (EMBs) for rejection monitoring are not specifically outlined in the guidelines. Furthermore, invasive coronary angiography (ICA) is still recommended as the gold-standard procedure, usually performed one year after surgery and every two years thereafter. This review focuses on recent advancements in non-invasive and contrast-saving imaging techniques that have been investigated for HT patients. The aim of the manuscript is to identify imaging modalities that may potentially replace or reduce the need for invasive procedures such as ICA and EMB, considering their respective advantages and disadvantages. We emphasize the transformative potential of non-invasive techniques in elevating patient care. Advanced echocardiography techniques, including strain imaging and tissue Doppler imaging, offer enhanced insights into cardiac function, while CMR, through its multi-parametric mapping techniques, such as T1 and T2 mapping, allows for the non-invasive assessment of inflammation and tissue characterization. Cardiac computed tomography (CCT), particularly with its ability to evaluate coronary artery disease and assess graft vasculopathy, emerges as an integral tool in the follow-up of HT patients. Recent studies have highlighted the potential of nuclear myocardial perfusion imaging, including myocardial blood flow quantification, as a non-invasive method for diagnosing and prognosticating CAV. These advanced imaging approaches hold promise in mitigating the need for invasive procedures like ICA and EMB when evaluating the benefits and limitations of each modality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...