Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38836574

RESUMO

Background: Increased left atrial pressure (LAP) has been associated with adverse outcomes after mitral transcatheter edge-to-edge repair (M-TEER). We sought to evaluate outcomes based on differences in post-procedural LAP measured after final clip deployment. Methods: We included consecutive patients who underwent M-TEER at our institution between 2014-2022 with LAP monitoring. Patients were stratified into 3 groups according to tertiles of post-TEER mean LAP. Outcomes were assessed using Kaplan-Meier analysis and Cox proportional hazard models. Results: We included 273 patients (mean age 76.8±10.8 years, 42.5% women, 78.4% Caucasian). The mean post-TEER LAP was 8.7±1.7 mmHg in tertile 1 (N=85), 14.4±1.6 mmHg in tertile 2 (N=95), and 21.9±3.8 mmHg in tertile 3 (N=93). In comparison with tertile 1, both tertiles 2 and 3 were associated with increased risk of all-cause mortality or heart failure hospitalization at 2 years (adjHR 2.27, 95% CI 1.25-4.12; and adjHR 3.00, 95% CI 1.59-5.64 respectively). Among patients with primary MR, higher LAP was associated with increased risk of 2-year all-cause mortality or heart failure hospitalization [tertile 2 vs. 1: adjHR 3.00, 95% CI 1.37-6.56; and tertile 3 vs. 1: adjHR 5.52, 95% CI 2.04-14.95). However, in patients with secondary MR, neither being in tertile 2 (adjHR 1.53; 95% CI 0.55-4.24), nor tertile 3 (adjHR 2.18; 95% CI 0.82-5.77) were associated with the composite outcome compared with tertile 1. Any degree of LAP reduction following M-TEER was associated with lower mortality or heart failure hospitalization compared with no LAP reduction (adjHR 0.59; 95% CI 0.39-0.88). Conclusions: Elevated LAP after M-TEER was associated with increased 2-year risk of mortality or heart failure hospitalization. Exploration of reasons for elevated LAP after M-TEER, and ways to lower it warrant further investigation.

2.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
3.
J Am Heart Assoc ; 13(11): e033447, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780160

RESUMO

BACKGROUND: Coronary microvascular function and hemodynamics may play a role in coronary circulation and myocardial remodeling in patients with aortic stenosis (AS). We aimed to evaluate the relationship between myocardial blood flow and myocardial function in patients with AS, no AS, and aortic valve sclerosis. METHODS AND RESULTS: We included consecutive patients who had resting transthoracic echocardiography and clinically indicated positron emission tomography myocardial perfusion imaging to capture their left ventricular ejection fraction, global longitudinal strain (GLS), and myocardial flow reserve (MFR). The primary outcome was major adverse cardiovascular event (all-cause mortality, myocardial infarction, or late revascularization). There were 2778 patients (208 with aortic sclerosis, 39 with prosthetic aortic valve, 2406 with no AS, and 54, 49, and 22 with mild, moderate, and severe AS, respectively). Increasing AS severity was associated with impaired MFR (P<0.001) and GLS (P<0.001), even when perfusion was normal. Statistically significant associations were noted between MFR and GLS, MFR and left ventricular ejection fraction, and MFR and left ventricular ejection fraction reserve. After a median follow-up of 349 (interquartile range, 116-662) days, 4 (7.4%), 5 (10.2%), and 6 (27.3%) patients experienced a major adverse cardiovascular event in the mild, moderate, and severe AS groups, respectively. In a matched-control analysis, patients with mild-to-moderate AS had higher rates of impaired MFR (52.9% versus 39.9%; P=0.048) and major adverse cardiovascular event (11.8% versus 3.0%; P=0.002). CONCLUSIONS: Despite lack of ischemia, as severity of AS increased, MFR decreased and GLS worsened, reflecting worse coronary microvascular health and myocardial remodeling. Positron emission tomography-derived MFR showed a significant independent correlation with left ventricular ejection fraction and GLS. Patients with prosthetic aortic valve showed a high prevalence of impaired MFR.


Assuntos
Estenose da Valva Aórtica , Reserva Fracionada de Fluxo Miocárdico , Microcirculação , Imagem de Perfusão do Miocárdio , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Masculino , Remodelação Ventricular/fisiologia , Idoso , Função Ventricular Esquerda/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Volume Sistólico/fisiologia , Microcirculação/fisiologia , Circulação Coronária/fisiologia , Ecocardiografia , Índice de Gravidade de Doença , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Estudos Retrospectivos , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
4.
Curr Cardiol Rep ; 26(7): 767-775, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38806975

RESUMO

PURPOSE OF REVIEW: This review explores the epidemiology, clinical traits, and diagnosis of Transcatheter Aortic Valve Replacement-Associated Infective Endocarditis (TAVR-IE) and mitral transcatheter edge-to-edge repair infective endocarditis (TEER-IE), focusing on a multimodal imaging approach. It addresses the rising prevalence of TAVR and TEER, emphasizing the need to understand long-term complications and clinical consequences, which poses significant challenges despite advancements in valve technology. RECENT FINDINGS: Studies report a variable incidence of TAVR-IE and TEER-IE influenced by diverse patient risk profiles and procedural factors. Younger age, male gender, and certain comorbidities emerge as patient-related risk factors. Procedure-related factors include intervention location, valve type, and technical aspects. Microbiologically, Staphylococcus aureus, Viridans Group Streptococcus, and Enterococcus are frequently encountered pathogens. TAVR-IE and TEER-IE diagnosis involves a multimodal imaging approach due to limitations in echocardiography. Blood cultures and imaging aid identification, with Fluorescence in situ hybridization is showing promise. Treatment encompasses medical management with antibiotics and, when necessary, surgical intervention. The management approach requires a multidisciplinary "Endocarditis Team." This review underscores the need for continued research to refine risk prediction, enhance diagnostic accuracy, and optimize management strategies for TAVR-IE, considering the evolving landscape of transcatheter interventions.


Assuntos
Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Antibacterianos/uso terapêutico , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/terapia , Endocardite/microbiologia , Endocardite/etiologia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38781428

RESUMO

AIMS: The association between secondary mitral regurgitation (MR) and right ventricular (RV) dysfunction in heart failure patients with non-ischemic cardiomyopathy (NICM) is unclear. Hence, our objective was to study the association between secondary MR and the occurrence of RV dysfunction among patients with NICM using cardiac magnetic resonance (CMR). METHODS AND RESULTS: Patients with NICM were enrolled in a prospective observational registry between 2008-2019. CMR was used to quantify MR severity along with RV function. RV dysfunction was defined as RV ejection fraction <45%. The outcome of the study was a composite event of all-cause death, heart transplantation, or left ventricular assist device implantation at follow-up. In the study cohort of 241 patients, RV dysfunction (RVEF < 45%) was present in 148 (61%). In comparison to patients without RV dysfunction, those with RV dysfunction had higher median MR volume (23 ml [IQR 16-31ml] vs 18 ml [IQR 12-25 ml], P=0.002) and MR fraction (33% [IQR 25-43%] vs 22% [IQR 15-29%], P<0.001). Furthermore, secondary MR was independently associated with RV dysfunction: MR volume ≥ 24ml (OR 3.21, 95% CI 1.26-8.15, P= 0.01) and MR fraction≥ 30% (OR 5.46, 95% 2.23-13.35, P=0.002). Increasing RVEF (every 1% increase) was independently associated with lower risk of adverse events (HR 0.98, 95% 0.95, 1.00, P=0.047). CONCLUSIONS: In patients with NICM, the severity of secondary MR is associated with an increased prevalence of RV dysfunction. RV dysfunction is not only associated with the severity of LV dysfunction, but also with the severity of secondary MR.

7.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567665

RESUMO

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Insuficiência da Valva Mitral/cirurgia , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Artéria Pulmonar , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
8.
Cardiovasc Revasc Med ; 65: 10-15, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38553281

RESUMO

BACKGROUND: The role of percutaneous coronary intervention (PCI) in patients with stable coronary artery disease (CAD) who subsequently undergo transcatheter aortic valve replacement (TAVR) remains uncertain. Therefore, we conducted this study to assess the association of PCI before TAVR with mortality and cardiovascular outcomes. METHODS: We used the TriNetX database (Jan 2012 - Aug 2022) and grouped patients into PCI (3 months or less) before TAVR and no PCI. We performed propensity score matched (PSM) analyses for outcomes at 30 days and 1 year. RESULTS: Of 17,120 patients undergoing TAVR, 2322 (14 %) had PCI, and 14,798 (86 %) did not have PCI before TAVR. In the PSM cohort (2026 patients in each group), PCI was not associated with lower all-cause mortality at 30 days (HR: 1.25, 95 % CI: 0.82-1.90) or 1 year (HR: 1.02, 95 % CI: 0.83-1.24). Frequency of repeat PCI after TAVR was low in both no PCI vs. PCI (2.4 % vs. 1.2 %) at 1 year; PCI was associated with a lower rate of repeat PCI (HR: 0.49, 95 % CI: 0.30-0.80). Sensitivity analysis revealed an E-value of 3.5 for repeat PCI (E-value for lower CI for HR: 1.81). PCI was not linked to reductions in MI, heart failure exacerbation, all-cause hospitalization, major bleeding, or permanent pacemaker/implantable cardioverter defibrillator. CONCLUSION: This analysis showed that PCI prior to TAVR was not associated with improvement in all-cause mortality. However, PCI was associated with a reduced rate of repeat PCI at 1 year.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Bases de Dados Factuais , Intervenção Coronária Percutânea , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Feminino , Resultado do Tratamento , Idoso de 80 Anos ou mais , Idoso , Fatores de Tempo , Fatores de Risco , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Medição de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estudos Retrospectivos , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia
11.
J Am Heart Assoc ; 13(5): e032784, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390821

RESUMO

BACKGROUND: Prior studies investigating the impact of residual mitral regurgitation (MR), tricuspid regurgitation (TR), and elevated predischarge transmitral mean pressure gradient (TMPG) on outcomes after mitral transcatheter edge-to-edge repair (TEER) have assessed each parameter in isolation. We sought to examine the prognostic value of combining predischarge MR, TR, and TMPG to study long-term outcomes after TEER. METHODS AND RESULTS: We reviewed the records of 291 patients who underwent successful mitral TEER at our institution between March 2014 and June 2022. Using well-established outcomes-related cutoffs for predischarge MR (≥moderate), TR (≥moderate), and TMPG (≥5 mm Hg), 3 echo profiles were developed based on the number of risk factors present (optimal: 0 risk factors, mixed: 1 risk factor, poor: ≥2 risk factors). Discrimination of the profiles for predicting the primary composite end point of all-cause mortality and heart failure hospitalization at 2 years was examined using Cox regression. Overall, mean age was 76.7±10.6 years, 43.3% were women, and 53% had primary MR. Two-year event-free survival was 61%. Predischarge TR≥moderate, MR≥moderate, and TMPG≥5 mm Hg were risk factors associated with the primary end point. Compared with the optimal profile, there was an incremental risk in 2-year event-rate with each worsening profile (optimal as reference; mixed profile: hazard ratio (HR), 2.87 [95% CI, 1.71-5.17], P<0.001; poor profile: HR, 3.76 [95% CI, 1.84-6.53], P<0.001). Echocardiographic profile was statistically associated with the 2-year mortality end point (optimal as reference; mixed profile: HR, 3.55 [95% CI, 1.81-5.96], P<0.001; poor profile: HR, 3.39 [95% CI, 2.56-7.33], P=0.02). CONCLUSIONS: The echocardiographic profile integrating predischarge TR, MR, and TMPG presents a novel prognostic stratification tool for patients undergoing mitral TEER.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Mercúrio , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Ecocardiografia , Instalações de Saúde , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
12.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224255

RESUMO

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Remoção de Dispositivo , Catéteres , Valvas Cardíacas , Sistema de Registros
15.
Curr Probl Cardiol ; 49(1 Pt A): 102042, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37595856

RESUMO

Data on the use of intracardiac echocardiography (ICE) guidance in mitral transcatheter edge-to-edge repair (mTEER) procedure is limited to case reports and small case series. Our study aims to assess the feasibility, safety, utilization patterns, and clinical outcomes of mTEER procedure with ICE guidance using a nationally representative real-world cohort of patients. This study used the National Inpatient Sample database from quarter 4 of 2015 to 2020. We used a propensity-matched analysis and adjusted odds ratios for in-hospital outcomes/complications. A P value of < 0.05 was considered significant. A total of 38,770 weighted cases of mTEER were identified. Of the included patients 665 patients underwent ICE-guided mTEER while 38,105 had TEE-guided mTEER. There were no differences in the in-hospital mortality between both groups (2.5% vs 3.0%, P = 0.58). Adjusted odds of in-hospital mortality (aOR 0.83, 95%CI [0.42-1.64]) were not significantly different. There were no differences in periprocedural complications including cardiac (aOR 0.85, 95%CI [0.54-1.35]), bleeding (aOR 1.45, 95%CI [0.93-2.33]), respiratory (aOR 0.88, 95%CI [0.61-1.25]), and renal (aOR 0.89, 95%CI [0.66-1.20]) complications between patients undergoing ICE-guided vs TEE-guided mTEER. There was no difference in GI complications between both groups (aOR 1.11, 95%CI [0.46-2.70]). The adjusted length of stay was less among ICE-guided mTEER (median: 1 vs 2, P < 0.01) with lower inflation-adjusted costs of hospitalization ($35,513 vs $47,067, P < 0.01). ICE-guided mTEER is safe when compared with TEE guided mTEER with no significant differences in in-hospital mortality, cardiac, bleeding, respiratory, and renal complications.


Assuntos
Ecocardiografia Transesofagiana , Pacientes Internados , Humanos , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Resultado do Tratamento
17.
BMJ ; 383: e077848, 2023 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-37973170

RESUMO

OBJECTIVE: To assess the absolute treatment effects of intravascular imaging guided versus angiography guided percutaneous coronary intervention in patients with coronary artery disease, considering their baseline risk. DESIGN: Systematic review and meta-analysis. DATA SOURCES: PubMed/Medline, Embase, and Cochrane Library databases up to 31 August 2023. STUDY SELECTION: Randomized controlled trials comparing intravascular imaging (intravascular ultrasonography or optical coherence tomography) guided versus coronary angiography guided percutaneous coronary intervention in adults with coronary artery disease. MAIN OUTCOME MEASURES: Random effect meta-analysis and GRADE (grading of recommendations, assessment, development, and evaluation) were used to assess certainty of evidence. Data included rate ratios and absolute risks per 1000 people for cardiac death, myocardial infarction, stent thrombosis, target vessel revascularization, and target lesion revascularization. Absolute risk differences were estimated using SYNTAX risk categories for baseline risks at five years, assuming constant rate ratios across different cardiovascular risk thresholds. RESULTS: In 20 randomized controlled trials (n=11 698), intravascular imaging guided percutaneous coronary intervention was associated with a reduced risk of cardiac death (rate ratio 0.53, 95% confidence interval 0.39 to 0.72), myocardial infarction (0.81, 0.68 to 0.97), stent thrombosis (0.44, 0.27 to 0.72), target vessel revascularization (0.74, 0.61 to 0.89), and target lesion revascularization (0.71, 0.59 to 0.86) but not all cause death (0.81, 0.64 to 1.02). Using SYNTAX risk categories, high certainty evidence showed that from low risk to high risk, intravascular imaging was likely associated with 23 to 64 fewer cardiac deaths, 15 to 19 fewer myocardial infarctions, 9 to 13 fewer stent thrombosis events, 28 to 38 fewer target vessel revascularization events, and 35 to 48 fewer target lesion revascularization events per 1000 people. CONCLUSIONS: Compared with coronary angiography guided percutaneous coronary intervention, intravascular imaging guided percutaneous coronary intervention was associated with significantly reduced cardiac death and cardiovascular outcomes in patients with coronary artery disease. The estimated absolute effects of intravascular imaging guided percutaneous coronary intervention showed a proportional relation with baseline risk, driven by the severity and complexity of coronary artery disease. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42023433568.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Fatores de Risco , Infarto do Miocárdio/etiologia , Trombose/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Morte , Resultado do Tratamento
18.
JACC Case Rep ; 22: 101973, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37790767

RESUMO

A 59-year-old male patient with history of rheumatic heart disease with 3 previous surgical aortic valve replacements with the last one being homograft followed by transcatheter aortic valve implantation in failed homograft presented with severe aortic regurgitation and cardiogenic shock requiring urgent TAV-in-TAV-in homograft. (Level of Difficulty: Advanced.).

20.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...