Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 17(5): e013579, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38629273

RESUMO

BACKGROUND: The prognostic impact of left atrial appendage (LAA) patency, including those with and without visible peri-device leak (PDL), post-LAA closure in patients with atrial fibrillation, remains elusive. METHODS: Patients with atrial fibrillation implanted with the WATCHMAN 2.5 device were prospectively enrolled. The device surveillance by cardiac computed tomography angiography was performed at 3 months post-procedure. Adverse events, including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular death, all-cause death, and the combined major adverse events (MAEs), were compared between patients with complete closure and LAA patency. RESULTS: Among 519 patients with cardiac computed tomography angiography surveillance at 3 months post-LAA closure, 271 (52.2%) showed complete closure, and LAA patency was detected in 248 (47.8%) patients, including 196 (37.8%) with visible PDL and 52 (10.0%) without visible PDL. During a median of 1193 (787-1543) days follow-up, the presence of LAA patency was associated with increased risks of stroke/TIA (adjusted hazard ratio for baseline differences, 3.22 [95% CI, 1.17-8.83]; P=0.023) and MAEs (adjusted hazard ratio, 1.12 [95% CI, 1.06-1.17]; P=0.003). Specifically, LAA patency with visible PDL was associated with increased risks of stroke/TIA (hazard ratio, 3.66 [95% CI, 1.29-10.42]; P=0.015) and MAEs (hazard ratio, 3.71 [95% CI, 1.71-8.07]; P=0.001), although LAA patency without visible PDL showed higher risks of MAEs (hazard ratio, 3.59 [95% CI, 1.28-10.09]; P=0.015). Incidences of stroke/TIA (2.8% versus 3.0% versus 6.7% versus 22.2%; P=0.010), cardiovascular death (0.9% versus 0% versus 1.7% versus 11.1%; P=0.005), and MAEs (4.6% versus 9.0% versus 11.7% versus 22.2%; P=0.017) increased with larger PDL (0, >0 to ≤3, >3 to ≤5, or >5 mm). Older age and discontinuing antiplatelet therapy at 6 months were independent predictors of stroke/TIA and MAEs in patients with LAA patency. CONCLUSIONS: LAA patency detected by cardiac computed tomography angiography at 3 months post-LAA closure is associated with unfavorable prognosis in patients with atrial fibrillation implanted with WATCHMAN 2.5 device. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03788941.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/mortalidade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Fatores de Risco , Ataque Isquêmico Transitório/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Medição de Risco , Hemorragia , Desenho de Prótese
2.
Front Cardiovasc Med ; 10: 1018877, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36776262

RESUMO

Objectives: This study aims to evaluate the diagnostic value of real-time four-dimensional transesophageal echocardiography (RT4D-TEE) for implant-related thrombus (IRT). Methods: We collected 1,125 patients with atrial fibrillation from May 2019 to February 2022 in our hospital. All patients accepted transesophageal echocardiography (TEE) examination to exclude any thrombi before the LAAC procedure. Results: There were 760 patients with LAAC, 66 patients with CIED, and 299 patients without any implantations. A total of 40 patients with an established diagnosis of IRT were further analyzed. The accurate detection rate of IRT by RT4D-TEE was 4.8% (40/826), which was higher than 3.8% (31/826) by 2D-TEE (P = 0.004). No IRT was found on TEE in the rest of the 786 patients. These 40 patients were divided into LAAC (n = 23) and CIED (n = 17) groups according to the results of RT4D-TEE. In the LAAC group, IRT distributed on different parts of the LAA occluder surface, 91.3% (21/23) with clumps of thrombi, and 8.7% (2/23) with a thin layer of thrombi covering the surface of the occluder. In the CIED group, thrombi were seen attached to the leads in the right atrium and right ventricle. The thrombi were beaded in 17.6% (3/17), corded in 17.6% (3/17), and clotted in the remaining 64.7% (11/17) of cases. After adjusting the anticoagulant dosage and following up for 6 months, 20% (8/40) of cases were successfully resolved, 67.5% (27/40) became smaller, and 12.5% (5/40) showed no changes. Conclusion: The accurate detection rate of IRT by RT4D-TEE was significantly higher than that by 2D-TEE. 2D-TEE has limitations, but RT4D-TEE can be used as an effective complementary method. Imaging and some clinical features differ significantly between IRT on occluder and IRT on CIED lead.

3.
Heliyon ; 9(1): e12662, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36691523

RESUMO

Background: Left atrial appendage (LAA) closure (LAAC) in atrial fibrillation (AF) patients with the reversed chicken-wing (RCW) LAA is challenging. Aims: To elucidate the LAAC strategy of the RCW-LAA. Methods: A total of 802 AF patients who were enrolled in the LAACablation registry for LAAC procedure were included, 55 of whom presented with the RCW-LAA. The WATCHMAN device was implanted using the standard protocol when the sheath depth was no less than the device depth (the simple group). For those with a sheath depth of less than the device depth (the complex group), device deployment was attempted with acceptable protrusion or after a repeated atrial transseptal puncture (re-ATP) at a more inferior and anterior position. The anatomical and procedural features were compared between groups and before and after the re-ATP. Results: The success rate of LAAC was significantly lower in patients with the RCW-LAA than with the other morphologies (92.7% vs. 98.8%, p = 0.001). Compared with the simple group, the complex group had shorter root depth and shorter neck length, and more LAAs in the complex group were at lower position (all p < 0.05). The sheath depth after the re-ATP was significantly greater than that before the re-ATP (18.8 ± 3.4 mm vs. 14.7 ± 2.6 mm, p < 0.001). For the patients who underwent re-ATP, the sheath went significantly deeper in successful procedures than in aborted procedures (19.7 ± 3.3 mm vs. 15.8 ± 1.8 mm, p = 0.040). Conclusions: The anatomical features of the RCW-LAA were related to the complexity of the LAAC procedure. The re-ATP at an inferior and anterior location could increase the success rate of LAAC. ClinicalTrialsgov: NCT03788941.

4.
Europace ; 25(1): 146-155, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35942655

RESUMO

AIMS: Activation mapping of premature atrial complexes (PACs) proves challenging due to interference by mechanical bumping and non-targeted ectopies. This study aims to compare the mapping efficacy, instant success, and long-term recurrence of catheter ablation for PACs with non-pulmonary vein (PV) and non-superior vena cava (SVC) origins between the novel dual-reference approach (DRA) and the routine single-reference approach (SRA) of mapping. METHODS AND RESULTS: Patients with symptomatic, drug-refractory PACs, or frequent residual PACs after atrial tachyarrhythmia ablation were enrolled. During activation mapping, the coronary sinus (CS) catheter was used as the only timing reference in the SRA group. In the DRA group, another catheter, which was spatially separated from the CS catheter, was used as the second reference. The timing difference between the two references was used to discriminate the targeted PACs from the uninterested rhythms. Procedural parameters and long-term recurrence were compared. A total of 188 patients (109 in SRA and 79 in DRA) were enrolled. The baseline characteristics were similar. Compared with the SRA group, the DRA group had less repeated mapping (1.2 ± 0.4 vs. 1.4 ± 0.5, P = 0.004), shorter mapping (15 ± 6 vs. 23 ± 7 min, P < 0.001) and procedural time (119 ± 28 vs. 132 ± 22 min, P = 0.001), similar procedural complication rates (3.6 vs. 3.8%, P > 0.999), higher instant success (96.2 vs. 87.2%, P = 0.039), and lower recurrence rate (15.2 vs. 29.3%, hazard ratio 1.943, P = 0.033) during a 24-month follow-up. CONCLUSION: As a novel strategy, the DRA shortens the procedural time and improves both instant and long-term success of PAC ablation, serving as a promising approach in mapping PACs with non-PV and non-SVC origins.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
6.
J Cardiovasc Electrophysiol ; 32(10): 2655-2664, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34428342

RESUMO

OBJECTIVES: To explore the value of detecting the peri-device leak (PDL) and device endothelialization after left atrial appendage closure (LAAC) by cardiac computed tomography (CT) in patients with atrial fibrillation (AF), who underwent Watchman LAAC combined with radiofrequency ablation of atrial fibrillation (AFCA). METHODS: Patients with symptomatic drug-refractory atrial fibrillation at high risk of stroke (CHA2 DS2 -VASc Score ≥ 2), who underwent Watchman LAAC combined with AFCA in our center from March 2017 to December 2018 were enrolled. Maximum diameter of LAA orifice was determined by preoperative CCTA. A standardized view of Watchman device was obtained by postoperative CCTA multiplannar reconstruction to evaluate the PDL and device endothelialization. RESULTS: Approximately 84 patients post successful LAAC and AFCA were enrolled in this study. The satisfactory LAA occlusion rate was 100%. There was no death, bleeding, stroke, and device-related thrombus (DRT) events. At 6-month postprocedure, CCTA images evidenced complete endothelialization in 44 patients (no contrast enhancement in LAA); contrast enhancement in LAA and visible PDL in 33 patients; contrast enhancement in LAA but without PDL in seven patients (incomplete device endothelialization). Maximum diameter of LAA orifice could independently predict the occurrence of PDL (odds ratio, 1.31; 95% confidence interval, 1.11-1.55; p = .002), sensitivity was 69.7% and specificity was 80.4% with the cutoff value of maximum diameter of LAA orifice more than 28.2 mm on predicting PDL. CONCLUSIONS: CCTA is feasible to evaluate PDL and device endothelialization after LAAC. The maximum diameter of LAA orifice derived from CT can independently predict the occurrence of post-LAAC PDL.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Radiofrequência , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Angiografia por Tomografia Computadorizada , Ecocardiografia Transesofagiana , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Chin Med J (Engl) ; 133(12): 1422-1428, 2020 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-32433041

RESUMO

BACKGROUND: Catheter ablation is effective in restoring sinus rhythm and left atrial appendage closure (LAAC) is increasingly used for stroke prevention in patients with atrial fibrillation (AF). We aimed to observe the feasibility and safety of performing AF ablation and LAAC in a single (one-stop) procedure. METHODS: Consecutive AF patients who underwent the combined procedure of AF ablation and LAAC with WATCHMAN device between March 2017 and September 2018 were prospectively enrolled. Baseline and intra-procedural parameters were evaluated. Three-month and subsequent 1-year follow-up were performed in all and earlier-enrolled subjects, respectively. RESULTS: A total of 178 AF patients (94 males, 68.9 ±â€Š8.1 years) underwent the one-stop procedure with CHA2DS2-VASc score 3.3 ±â€Š1.5 and HAS-BLED score 1.6 ±â€Š1.0, respectively. Pulmonary vein isolation was achieved in all patients while additional linear ablation was applied if the operator deemed necessary, yielding immediate ablation success rate of 98.9% (176/178). In the subsequent LAAC, satisfactory seal (residual leak <5 mm) was achieved in all patients. One stroke and four cardiac perforations occurred peri-operatively. At 3-month follow-up, sinus rhythm and satisfactory seal were maintained in 153/178 (86.0%) and 178/178 (100%) patients, respectively. One stroke and one delayed cardiac tamponade occurred, while no device-related thrombus or device migration was observed. During the 1-year follow-up for the earlier enrolled subjects, 52/72 (72.2%) of the patients maintained sinus rhythm. There was no stroke or systemic embolism observed. CONCLUSION: Combining catheter ablation and LAAC in a single procedure can be successfully and safely performed in non-valvular AF patients of Chinese population.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Humanos , Masculino , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 30(10): 1868-1876, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31353748

RESUMO

INTRODUCTION: Catheter ablation of atrial fibrillation (AFCA) and left atrial appendage closure (LAAC) exert opposite effects on left atrial (LA) size. We aim to observe the net impact of combined AFCA and LAAC strategy on LA size and explore those factors which might affect the postprocedure LA structural remodeling. METHODS: A total of 53 patients, who underwent combined AFCA and Watchman LAAC in our center from March to December 2017, were enrolled. Atrial fibrillation (AF) recurrence was monitored after the procedure. Left atrial volume (LAV) and left atrial appendage volume (LAAV) were measured by Mimics based on dual-source computed tomography images. RESULTS: At 6 months, sinus rhythm (SR) was maintained in 79.2% patients. LAV was significantly reduced (130.2 ± 36.3 mL to 107.1 ± 30.0 ml; P < .001) in SR maintenance group, but not in AF recurrence group (138.8 ± 39.3 mL to 137.9 ± 36.9 mL; P = .671). In SR group, preoperative LAAV/LAV ratio (B = -0.894; P = .015), NT-proBNP (B = 0.005; P = .019) and left ventricular ejection fraction (LVEF) (B = -0.778; P < .001) could interactively affect the extent of postoperative LA structural reverse remodeling, among which LAAV/LAV ratio could independently predict the significance of reverse remodeling (≥15% reduction in LAV) (OR, 0.56; 95% CI, 0.34-0.90; P = .018). A preoperative LAAV/LAV ratio less than 7.1% is indicative of significant LA structural reverse remodeling in this patient cohort. CONCLUSIONS: LA structural reverse remodeling could be evidenced in patients with maintained SR following combined AFCA and LAAC. Smaller LAAV/LAV ratio, higher NT-proBNP or lower LVEF at baseline are associated with more significant LA structural reverse remodeling, while LAAV/LAV ratio can predict the significance of the process after one-stop treatment.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Remodelamento Atrial , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Potenciais de Ação , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ablação por Cateter/efeitos adversos , Feminino , Fibrose , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...