Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Magn Reson Med Sci ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38960679

RESUMO

PURPOSE: We developed new deep learning-based hierarchical brain segmentation (DLHBS) method that can segment T1-weighted MR images (T1WI) into 107 brain subregions and calculate the volume of each subregion. This study aimed to evaluate the repeatability and reproducibility of volume estimation using DLHBS and compare them with those of representative brain segmentation tools such as statistical parametric mapping (SPM) and FreeSurfer (FS). METHODS: Hierarchical segmentation using multiple deep learning models was employed to segment brain subregions within a clinically feasible processing time. The T1WI and brain mask pairs in 486 subjects were used as training data for training of the deep learning segmentation models. Training data were generated using a multi-atlas registration-based method. The high quality of training data was confirmed through visual evaluation and manual correction by neuroradiologists. The brain 3D-T1WI scan-rescan data of the 11 healthy subjects were obtained using three MRI scanners for evaluating the repeatability and reproducibility. The volumes of the eight ROIs-including gray matter, white matter, cerebrospinal fluid, hippocampus, orbital gyrus, cerebellum posterior lobe, putamen, and thalamus-obtained using DLHBS, SPM 12 with default settings, and FS with the "recon-all" pipeline. These volumes were then used for evaluation of repeatability and reproducibility. RESULTS: In the volume measurements, the bilateral thalamus showed higher repeatability with DLHBS compared with SPM. Furthermore, DLHBS demonstrated higher repeatability than FS in across all eight ROIs. Additionally, higher reproducibility was observed with DLHBS in both hemispheres of six ROIs when compared with SPM and in five ROIs compared with FS. The lower repeatability and reproducibility in DLHBS were not observed in any comparisons. CONCLUSION: Our results showed that the best performance in both repeatability and reproducibility was found in DLHBS compared with SPM and FS.

2.
Radiol Phys Technol ; 16(3): 373-383, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37291372

RESUMO

In automated analyses of brain morphometry, skull stripping or brain extraction is a critical first step because it provides accurate spatial registration and signal-intensity normalization. Therefore, it is imperative to develop an ideal skull-stripping method in the field of brain image analysis. Previous reports have shown that convolutional neural network (CNN) method is better at skull stripping than non-CNN methods. We aimed to evaluate the accuracy of skull stripping in a single-contrast CNN model using eight-contrast magnetic resonance (MR) images. A total of 12 healthy participants and 12 patients with a clinical diagnosis of unilateral Sturge-Weber syndrome were included in our study. A 3-T MR imaging system and QRAPMASTER were used for data acquisition. We obtained eight-contrast images produced by post-processing T1, T2, and proton density (PD) maps. To evaluate the accuracy of skull stripping in our CNN method, gold-standard intracranial volume (ICVG) masks were used to train the CNN model. The ICVG masks were defined by experts using manual tracing. The accuracy of the intracranial volume obtained from the single-contrast CNN model (ICVE) was evaluated using the Dice similarity coefficient [= 2(ICVE ⋂ ICVG)/(ICVE + ICVG)]. Our study showed significantly higher accuracy in the PD-weighted image (WI), phase-sensitive inversion recovery (PSIR), and PD-short tau inversion recovery (STIR) compared to the other three contrast images (T1-WI, T2-fluid-attenuated inversion recovery [FLAIR], and T1-FLAIR). In conclusion, PD-WI, PSIR, and PD-STIR should be used instead of T1-WI for skull stripping in the CNN models.


Assuntos
Encéfalo , Crânio , Humanos , Crânio/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos
3.
Sci Rep ; 13(1): 8526, 2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37237139

RESUMO

Motion artefacts caused by the patient's body movements affect magnetic resonance imaging (MRI) accuracy. This study aimed to compare and evaluate the accuracy of motion artefacts correction using a conditional generative adversarial network (CGAN) with an autoencoder and U-net models. The training dataset consisted of motion artefacts generated through simulations. Motion artefacts occur in the phase encoding direction, which is set to either the horizontal or vertical direction of the image. To create T2-weighted axial images with simulated motion artefacts, 5500 head images were used in each direction. Of these data, 90% were used for training, while the remainder were used for the evaluation of image quality. Moreover, the validation data used in the model training consisted of 10% of the training dataset. The training data were divided into horizontal and vertical directions of motion artefact appearance, and the effect of combining this data with the training dataset was verified. The resulting corrected images were evaluated using structural image similarity (SSIM) and peak signal-to-noise ratio (PSNR), and the metrics were compared with the images without motion artefacts. The best improvements in the SSIM and PSNR were observed in the consistent condition in the direction of the occurrence of motion artefacts in the training and evaluation datasets. However, SSIM > 0.9 and PSNR > 29 dB were accomplished for the learning model with both image directions. The latter model exhibited the highest robustness for actual patient motion in head MRI images. Moreover, the image quality of the corrected image with the CGAN was the closest to that of the original image, while the improvement rates for SSIM and PSNR were approximately 26% and 7.7%, respectively. The CGAN model demonstrated a high image reproducibility, and the most significant model was the consistent condition of the learning model and the direction of the appearance of motion artefacts.


Assuntos
Aprendizado Profundo , Humanos , Processamento de Imagem Assistida por Computador/métodos , Artefatos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos
4.
Acta Radiol ; 64(2): 741-750, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35350871

RESUMO

BACKGROUND: Voxel-based morphometry (VBM) using magnetic resonance imaging (MR) has been used to estimate cortical atrophy associated with various diseases. However, there are mis-segmentations of segmented gray matter image in VBM. PURPOSE: To study a twofold evaluation of single- and multi-channel segmentation using synthetic MR images: (1) mis-segmentation of segmented gray matter images in transverse and cavernous sinuses; and (2) accuracy and repeatability of segmented gray matter images. MATERIAL AND METHODS: A total of 13 healthy individuals were scanned with 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) sequence on a 1.5-T scanner. Three of the 13 healthy participants were scanned five consecutive times for evaluation of repeatability. We used SyMRI software to create images with three contrasts: T1-weighted (T1W), T2-weighted (T2W), and proton density-weighted (PDW) images. Manual regions of interest (ROI) on T1W imaging were individually set as the gold standard in the transverse sinus, cavernous sinus, and putamen. Single-channel (T1W) and multi-channel (T1W + T2W, T1W + PDW, and T1W + T2W + PDW imaging) segmentations were performed with statistical parametric mapping 12 software. RESULTS: We found that mis-segmentations in both the transverse and cavernous sinuses were large in single-channel segmentation compared with multi-channel segmentations. Furthermore, the accuracy of segmented gray matter images in the putamen was high in both multi-channel T1W + PDW and T1W + T2W + PDW segmentations compared with other segmentations. Finally, the highest repeatability of left putamen volumetry was found with multi-channel segmentation T1WI + PDWI. CONCLUSION: Multi-channel segmentation with T1WI + PDWI provides good results for VBM compared with single-channel and other multi-channel segmentations.


Assuntos
Substância Cinzenta , Putamen , Humanos , Putamen/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Software
5.
Radiat Oncol ; 17(1): 69, 2022 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-35392947

RESUMO

BACKGROUND: Four-dimensional cone-beam computed tomography (4D-CBCT) can visualize moving tumors, thus adaptive radiation therapy (ART) could be improved if 4D-CBCT were used. However, 4D-CBCT images suffer from severe imaging artifacts. The aim of this study is to investigate the use of synthetic 4D-CBCT (sCT) images created by a cycle generative adversarial network (CycleGAN) for ART for lung cancer. METHODS: Unpaired thoracic 4D-CBCT images and four-dimensional multislice computed tomography (4D-MSCT) images of 20 lung-cancer patients were used for training. High-quality sCT lung images generated by the CycleGAN model were tested on another 10 cases. The mean and mean absolute errors were calculated to assess changes in the computed tomography number. The structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) were used to compare the sCT and original 4D-CBCT images. Moreover, a volumetric modulation arc therapy plan with a dose of 48 Gy in four fractions was recalculated using the sCT images and compared with ideal dose distributions observed in 4D-MSCT images. RESULTS: The generated sCT images had fewer artifacts, and lung tumor regions were clearly observed in the sCT images. The mean and mean absolute errors were near 0 Hounsfield units in all organ regions. The SSIM and PSNR results were significantly improved in the sCT images by approximately 51% and 18%, respectively. Moreover, the results of gamma analysis were significantly improved; the pass rate reached over 90% in the doses recalculated using the sCT images. Moreover, each organ dose index of the sCT images agreed well with those of the 4D-MSCT images and were within approximately 5%. CONCLUSIONS: The proposed CycleGAN enhances the quality of 4D-CBCT images, making them comparable to 4D-MSCT images. Thus, clinical implementation of sCT-based ART for lung cancer is feasible.


Assuntos
Neoplasias Pulmonares , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Quadridimensional , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
6.
Magn Reson Med Sci ; 21(1): 41-57, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35185061

RESUMO

Surface-based morphometry (SBM) is extremely useful for estimating the indices of cortical morphology, such as volume, thickness, area, and gyrification, whereas voxel-based morphometry (VBM) is a typical method of gray matter (GM) volumetry that includes cortex measurement. In cases where SBM is used to estimate cortical morphology, it remains controversial as to whether VBM should be used in addition to estimate GM volume. Therefore, this review has two main goals. First, we summarize the differences between the two methods regarding preprocessing, statistical analysis, and reliability. Second, we review studies that estimate cortical morphological changes using VBM and/or SBM and discuss whether using VBM in conjunction with SBM produces additional values. We found cases in which detection of morphological change in either VBM or SBM was superior, and others that showed equivalent performance between the two methods. Therefore, we concluded that using VBM and SBM together can help researchers and clinicians obtain a better understanding of normal neurobiological processes of the brain. Moreover, the use of both methods may improve the accuracy of the detection of morphological changes when comparing the data of patients and controls.In addition, we introduce two other recent methods as future directions for estimating cortical morphological changes: a multi-modal parcellation method using structural and functional images, and a synthetic segmentation method using multi-contrast images (such as T1- and proton density-weighted images).


Assuntos
Substância Cinzenta , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Substância Cinzenta/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
7.
Magn Reson Med Sci ; 21(1): 58-70, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35173096

RESUMO

Diffusion tensor imaging (DTI) has been established its usefulness in evaluating normal-appearing white matter (NAWM) and other lesions that are difficult to evaluate with routine clinical MRI in the evaluation of the brain and spinal cord lesions in multiple sclerosis (MS), a demyelinating disease. With the recent advances in the software and hardware of MRI systems, increasingly complex and sophisticated MRI and analysis methods, such as q-space imaging, diffusional kurtosis imaging, neurite orientation dispersion and density imaging, white matter tract integrity, and multiple diffusion encoding, referred to as advanced diffusion MRI, have been proposed. These are capable of capturing in vivo microstructural changes in the brain and spinal cord in normal and pathological states in greater detail than DTI.This paper reviews the current status of recent advanced diffusion MRI for assessing MS in vivo as part of an issue celebrating two decades of magnetic resonance in medical sciences (MRMS), an official journal of the Japanese Society of Magnetic Resonance in Medicine.


Assuntos
Esclerose Múltipla , Substância Branca , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Humanos , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Medula Espinal/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
8.
Magn Reson Med Sci ; 21(3): 517-524, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34305081

RESUMO

The volumes of intracranial tissues of 40 healthy volunteers acquired from 0.3- and 3-T scanners were compared using intraclass correlation coefficients, correlation analyses, and Bland-Altman analyses. We found high intraclass correlation coefficients, high Pearson's correlation coefficients, and low percentage biases in all tissues and most of the brain regions, although small differences were observed in some areas. These findings may support the validity of brain volumetry with low-field magnetic resonance imaging.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
9.
Acta Radiol ; 63(6): 814-821, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34279134

RESUMO

BACKGROUND: Atlas-based volumetry using three-dimensional T1-weighted (3D-T1W) magnetic resonance imaging (MRI) has been used previously to evaluate the volumes of intracranial tissues. PURPOSE: To evaluate the detectability of volume difference and accuracy for volumetry using smoothed data with an atlas-based method. MATERIAL AND METHODS: Twenty healthy individuals and 24 patients with idiopathic normal-pressure hydrocephalus (iNPH) underwent 3-T MRI, and sagittal 3D-T1W images were obtained in all participants. Signal values (as tissue probability) of voxels in five segmented data types (gray matter, white matter, cerebrospinal fluid [CSF], skull, soft tissue) derived from the 3D-T1W images with SPM 12 software were assigned simulated 3D-T1W signal intensities to each tissue image. The assigned data were termed "reference data." We created a reference 3D-T1W image that included the reference data of all five tissue types. Standard volumes were measured for the reference CSF data with region of interest of lateral ventricle in native space, and measured volumes were obtained for non-smoothed and smoothed-modulated data. Detectability was evaluated between measured volumes in the healthy control and iNPH groups. Accuracy was evaluated as the difference between the mean measured and standard volumes. RESULTS: In group comparison of measured volumes between the healthy control and iNPH groups, the lowest P value was for smoothed-modulated CSF data. In both groups, the largest difference from the standard volume was found for the mean of the measured volumes for smoothed-modulated CSF data. CONCLUSION: Our study shows that using smoothed data can improve detectability in group comparison. However, using smoothed data reduces the accuracy of volumetry.


Assuntos
Hidrocefalia , Processamento de Imagem Assistida por Computador , Encéfalo/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Software
10.
Juntendo Iji Zasshi ; 68(1): 44-51, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38911006

RESUMO

Background: The evolution of radiological technology is one of the most remarkable events of modern medical technology. Radiological examination has resulted in non-invasive, individual diagnostic imaging, which has contributed significantly to successful medical treatment of patients. Key Concepts: This review summarizes past and current Japanese educational systems for radiological technologists with a historical perspective focusing on three periods. The first period begins with Roentgen's discovery of X-rays (1895), the second period begins with the establishment of the Radiological X-ray Technologist Act (1951), and the third period begins with the launch of the first university course for radiological technologists (1987). It is conceivable that those periods are in accordance with the technological paradigm shifts, including the development of contrast radiography and the application of CT and MRI to clinical practice. To maintain awareness of the most recent available technologies and maximize safety, educational programs teaching the latest knowledge were offered during each period. Conclusions: The advanced technologies require highly skilled radiological technologists and highly established educational systems. At present, over 70% of Japanese educational programs for radiological technologists are university courses leading to a bachelor's degree. The increasing globalization of radiological technology requires future radiological education systems to have a global perspective.

11.
Invest Radiol ; 56(11): 669-679, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34292257

RESUMO

ABSTRACT: Low-field magnetic resonance imaging (MRI) systems have seen a renaissance recently due to improvements in technology (both hardware and software). Originally, the performance of low-field MRI systems was rated lower than their actual clinical usefulness, and they were viewed as low-cost but poorly performing systems. However, various applications similar to high-field MRI systems (1.5 T and 3 T) have gradually become possible, culminating with high-performance low-field MRI systems and their adaptations now being proposed that have unique advantages over high-field MRI systems in various aspects. This review article describes the physical characteristics of low-field MRI systems and presents both their advantages and disadvantages for clinical use (past to present), along with their cutting-edge clinical applications.


Assuntos
Imageamento por Ressonância Magnética , Software , Espectroscopia de Ressonância Magnética
12.
Vis Comput Ind Biomed Art ; 4(1): 21, 2021 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-34304321

RESUMO

To minimize radiation risk, dose reduction is important in the diagnostic and therapeutic applications of computed tomography (CT). However, image noise degrades image quality owing to the reduced X-ray dose and a possible unacceptably reduced diagnostic performance. Deep learning approaches with convolutional neural networks (CNNs) have been proposed for natural image denoising; however, these approaches might introduce image blurring or loss of original gradients. The aim of this study was to compare the dose-dependent properties of a CNN-based denoising method for low-dose CT with those of other noise-reduction methods on unique CT noise-simulation images. To simulate a low-dose CT image, a Poisson noise distribution was introduced to normal-dose images while convoluting the CT unit-specific modulation transfer function. An abdominal CT of 100 images obtained from a public database was adopted, and simulated dose-reduction images were created from the original dose at equal 10-step dose-reduction intervals with a final dose of 1/100. These images were denoised using the denoising network structure of CNN (DnCNN) as the general CNN model and for transfer learning. To evaluate the image quality, image similarities determined by the structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were calculated for the denoised images. Significantly better denoising, in terms of SSIM and PSNR, was achieved by the DnCNN than by other image denoising methods, especially at the ultra-low-dose levels used to generate the 10% and 5% dose-equivalent images. Moreover, the developed CNN model can eliminate noise and maintain image sharpness at these dose levels and improve SSIM by approximately 10% from that of the original method. In contrast, under small dose-reduction conditions, this model also led to excessive smoothing of the images. In quantitative evaluations, the CNN denoising method improved the low-dose CT and prevented over-smoothing by tailoring the CNN model.

13.
Magn Reson Imaging ; 78: 90-97, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33444595

RESUMO

INTRODUCTION: Recently, three-dimensional (3D) quantitative synthetic magnetic resonance imaging (MRI), which quantifies tissue properties and creates multiple contrast-weighted images, has been enabled by 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS). However, the relatively long scan time has hindered its introduction into clinical practice. A hybrid of compressed sensing and parallel imaging (Compressed sensing-sensitivity encoding: CS-SENSE) can accelerate 3D-QALAS; however, whether CS-SENSE affects the quantitative values acquired by 3D-QALAS remains unexplored. Therefore, this study aimed to examine the effects of reduction factors of CS-SENSE (RCSS) on the quantitative values derived from 3D-QALAS, by assessing the signal-to-noise ratio (SNR) of the quantitative maps, as well as accuracy (linearity and bias) and repeatability of measured quantitative values. METHODS: In this study, the ISMRM/NIST standardized phantom was scanned on a 1.5-T MRI scanner with 3D-QALAS using RCSS in the range between 1 and 3, with intervals of 0.2, and between 3 and 10 with intervals of 0.5. The T1, T2, and proton density (PD) values were calculated from the imaging data. For each quantitative value, the SNR, the coefficient of determination (R2) of a linear regression model, the error rate, and the within-subject coefficient of variation (wCV) were calculated for each RCSS and compared. RESULTS: Within the clinically-relevant dynamic range of the brain of T1 and T2 (T1: 200-1400 ms; T2; 50-400 ms) and PD value of 15-100% calculated from 3D-QALAS, the effects of RCSS on quantitative values was small between 1 and 2.8, with SNR ≧ 10, R2 ≧ 0.9, error rate ≦ 10%, and wCV ≦ 10%, except for T2 values of 186.1 and 258.4 ms. CONCLUSIONS: CS-SENSE enabled the reduction of the scan time of 3D-QALAS by 63.5% (RCSS = 2.8) while maintaining the SNR of quantitative maps and accuracy and repeatability of the quantitative values.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Modelos Lineares , Masculino , Razão Sinal-Ruído
14.
Magn Reson Med Sci ; 20(1): 40-46, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32074592

RESUMO

PURPOSE: The aim of this study was to investigate whether the detectability of brain volume change in voxel-based morphometry (VBM) with gray matter images is affected by mild white matter lesions (MWLs). METHODS: Three-dimensional T1-weighted images (3D-T1WIs) of 11 healthy subjects were obtained using a 3T MR scanner. We initially created 3D-T1WIs with focal cortical atrophy simulated cortical atrophy in left amygdala (type A) and the left medial frontal lobe (type B) from control 3D-T1WIs. Next, the following three types of MWL images were created: type A + 1L and type B + 1L images, only one white matter lesion; type A + 4L and type B + 4L images, four white matter lesions at distant positions; and type A + 4L* and type B + 4L* images, four white matter lesions at clustered positions. Comparisons between the control group and the other groups were performed with VBM using segmented gray matter images. RESULTS: The gray matter volume was significantly lower in the type A group than in the control group, and similar results were observed in the type A + 1L, type A + 4L, and type A + 4L* groups. Additionally, the gray matter volume was significantly lower in the type B group than in the control group, and similar results were observed in the type B + 1L, type B + 4L, and type B + 4L* groups, but the cluster size in type B + 4L* was smaller than that in type B. CONCLUSION: Our study showed that the detectability of brain volume change in VBM with gray matter images was not decreased by MWLs as lacunar infarctions. Therefore, we think that group comparisons with VBM should be analyzed by groups including and excluding subjects with MWLs, respectively.


Assuntos
Encefalopatias , Substância Cinzenta , Imageamento por Ressonância Magnética/métodos , Substância Branca , Encefalopatias/diagnóstico por imagem , Encefalopatias/patologia , Substância Cinzenta/diagnóstico por imagem , Substância Cinzenta/patologia , Humanos , Imageamento Tridimensional , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
15.
J Clin Neurosci ; 79: 178-182, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33070892

RESUMO

Brain extraction represents an important step in numerous neuroimaging analyses. The brain extraction tool (BET)2 is a widely used deformable model-based approach for extraction of intracranial volume (ICV). The aim of this study is to estimate the ICV extraction accuracy using synthetic MR(SyMRI) method and BET2 in healthy adult participants and patients with Sturge-Weber Syndrome (SWS), including infants. 'Quantification of relaxation times and proton density by multi-echo acquisition of saturation recovery with turbo-spin-echo readout' (QRAPMASTER) with a 3.0 T magnetic resonance image (MRI) system was used for data acquisition. Statistical evaluations were performed with linear regression analysis and the Jaccard similarity coefficient (J). ICV extraction accuracy with synthetic MR method is found to be higher than BET2, for both aged healthy participants and SWS.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Software , Síndrome de Sturge-Weber/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Voluntários Saudáveis , Humanos , Lactente , Imageamento por Ressonância Magnética/métodos , Masculino
16.
J Physiol Sci ; 70(1): 43, 2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-32948133

RESUMO

The relationship between long-term intensive training and brain plasticity in gymnasts has recently been reported. However, the relationship between abilities in different gymnastic events and brain structural changes has not been explored. This study aimed to evaluate the correlation between world-class gymnasts (WCGs)' specific abilities in different gymnastics events and their gray matter (GM) volume. Ten right-handed Japanese male WCGs and 10 right-handed gender- and age-matched controls with no history of gymnastic training participated in this study. Whole brain three-dimensional T1-weighted images (magnetization-prepared rapid gradient-echo sequence) with 0.90 mm3 voxels were obtained using a 3 T-MRI scanner from each subject. Volume-based morphometry (VolBM) was used to compare GM volume differences between WCGs and controls. We then explored the correlation between specific gymnastic abilities using different gymnastic apparatuses, and GM volume. Significantly higher GM volumes (false discovery rate-corrected p < 0.05) in the inferior parietal lobule, middle temporal gyrus, precentral gyrus, rostral middle frontal gyrus, and superior frontal gyrus were demonstrated in WCGs, compared with controls using VolBM. Moreover, significant positive correlations were observed between brain regions and the difficulty scores for each gymnastic event, for example, rings and inferior parietal lobule and parallel bars and rostral middle frontal gyrus. These results may reflect the neural basis of an outstanding gymnastic ability resulting from brain plasticity in areas associated with spatial perception, vision, working memory, and motor control.


Assuntos
Atletas , Espessura Cortical do Cérebro , Mapeamento Encefálico , Substância Cinzenta/diagnóstico por imagem , Ginástica , Imageamento por Ressonância Magnética , Adolescente , Desempenho Atlético , Estudos de Casos e Controles , Substância Cinzenta/fisiologia , Humanos , Masculino , Plasticidade Neuronal , Tamanho do Órgão , Condicionamento Físico Humano , Valor Preditivo dos Testes , Adulto Jovem
17.
J Clin Neurosci ; 74: 69-75, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32007376

RESUMO

The aim of this study was to evaluate changes in measured volumes using Statistical Parametric Mapping (SPM) 12 caused by contrast changes in magnetic resonance (MR) image. Twenty-one healthy subjects participated in the study. From all subjects, 3D T1-weighted images (T1WIs) were obtained using a 3T scanner. In the first step of creating reference volume data, we used SPM12 to binarize all the segmented data. In the second step, we assigned simulated 3D-T1WI signal intensities to each tissue image and used the following values. The last step was integration of each tissue image to generate 3D-T1WI simulated reference volume data for each participant. To create the reference 3D-T1WIs with various contrasts from the reference volume data, we varied the signal intensity of gray matter from 900 to 600, 700, 1100, 1300, and 1400. The reference 3D-T2WI was acquired using the method used for 3D-T1WIs. Then, six 3D-T1WIs were processed using intrasubject bias-correction processing with SPM12, resulting in six new 3D-T1WIs of nonuniform signal intensities. Thirteen volume data sets were segmented into native-space tissue probability data using SPM12. Examination of the 3D data without nonuniform signal intensity showed that significant differences in measured volumes were not observed on repeated analysis of variance, but examination of the 3D data with nonuniform signal intensity did show significant differences in measured volumes in gray matter and CSF but not in white matter. Measured volumes using segmented tissue probability data obtained using SPM12 were not influenced by the contrasts of analyzed images.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Probabilidade , Substância Branca/diagnóstico por imagem
19.
Radiol Phys Technol ; 13(1): 76-82, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31898013

RESUMO

The aim of this study was to evaluate the effect of changing the contrast of an analyzed image on the accuracy of intracranial volume (ICV) extraction using the Brain Extraction Tool (BET2) in healthy adults and patients with Sturge-Weber syndrome (SWS), including infants. Twelve SWS patients, including infants, and 12 healthy participants were imaged on a 3.0-T magnetic resonance imaging (MRI) machine. All individuals underwent quantification of relaxation times and proton density using multi-echo acquisition of saturation recovery with turbo-spin-echo readout (QRAPMASTER). Based on the QRAPMASTER data, we created images with seven contrasts (T1-WI, T2-WI, PD-WI, T2 short-tau inversion recovery [STIR], proton density [PD] STIR, T2STIR + PDSTIR, and T1-WI + T2-WI + PD-WI) by post-processing with SyMRI software. ICVs extracted with BET2 from the FMRIB (Functional Magnetic Resonance Imaging of the Brain) Software Library with each of the seven image contrasts were compared with manually extracted ICVs, which is the gold standard reviewed by a board-certificated neuroradiologist. Manual extraction was performed on T1-WI and T2STIR. Statistical analyses were performed with Jaccard similarity coefficients (J). The highest J score was found in T1-WI + T2-WI + PD-WI in all participants (0.8451); T1-WI in healthy participants (0.8984); T2STIR in participants with SWS (0.8325). Our findings suggest that T1-WI and T2STIR should be used in ICV extraction performed using BET2 on healthy participants and infants, respectively. Additionally, if the analyzed individuals include both healthy participants and infants, T1-WI + T2-WI + PD-WI should be used.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Síndrome de Sturge-Weber/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Meios de Contraste/farmacologia , Reações Falso-Positivas , Feminino , Humanos , Lactente , Imageamento por Ressonância Magnética , Masculino , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Software , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...