Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros













Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 32(9): 15760-15773, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38859218

RESUMO

Fluorescence molecular tomography (FMT) serves as a noninvasive modality for visualizing volumetric fluorescence distribution within biological tissues, thereby proving to be an invaluable imaging tool for preclinical animal studies. The conventional FMT relies upon a point-by-point raster scan strategy, enhancing the dataset for subsequent reconstruction but concurrently elongating the data acquisition process. The resultant diminished temporal resolution has persistently posed a bottleneck, constraining its utility in dynamic imaging studies. We introduce a novel system capable of simultaneous FMT and surface extraction, which is attributed to the implementation of a rapid line scanning approach and dual-camera detection. The system performance was characterized through phantom experiments, while the influence of scanning line density on reconstruction outcomes has been systematically investigated via both simulation and experiments. In a proof-of-concept study, our approach successfully captures a moving fluorescence bolus in three dimensions with an elevated frame rate of approximately 2.5 seconds per frame, employing an optimized scan interval of 5 mm. The notable enhancement in the spatio-temporal resolution of FMT holds the potential to broaden its applications in dynamic imaging tasks, such as surgical navigation.


Assuntos
Imageamento Tridimensional , Imagens de Fantasmas , Imageamento Tridimensional/métodos , Fluorescência , Animais , Imagem Óptica/métodos , Luz
2.
Nat Commun ; 15(1): 2341, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491065

RESUMO

Nanothermometers enable the detection of temperature changes at the microscopic scale, which is crucial for elucidating biological mechanisms and guiding treatment strategies. However, temperature monitoring of micron-scale structures in vivo using luminescent nanothermometers remains challenging, primarily due to the severe scattering effect of biological tissue that compromises the imaging resolution. Herein, a lanthanide luminescence nanothermometer with a working wavelength beyond 1500 nm is developed to achieve high-resolution temperature imaging in vivo. The energy transfer between lanthanide ions (Er3+ and Yb3+) and H2O molecules, called the environment quenching assisted downshifting process, is utilized to establish temperature-sensitive emissions at 1550 and 980 nm. Using an optimized thin active shell doped with Yb3+ ions, the nanothermometer's thermal sensitivity and the 1550 nm emission intensity are enhanced by modulating the environment quenching assisted downshifting process. Consequently, minimally invasive temperature imaging of the cerebrovascular system in mice with an imaging resolution of nearly 200 µm is achieved using the nanothermometer. This work points to a method for high-resolution temperature imaging of micron-level structures in vivo, potentially giving insights into research in temperature sensing, disease diagnosis, and treatment development.


Assuntos
Elementos da Série dos Lantanídeos , Animais , Camundongos , Elementos da Série dos Lantanídeos/química , Temperatura , Luminescência , Diagnóstico por Imagem , Íons
3.
J Biophotonics ; 17(2): e202300214, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37877307

RESUMO

Head-mounted miniaturized fluorescence microscopy (Miniscope) has emerged as a significant tool in neuroscience, particularly for behavioral studies in awake rodents. However, the challenges of image quality control and standardization persist for both Miniscope users and developers. In this study, we propose a cost-effective and comprehensive toolkit named MiniMounter. This toolkit comprises a hardware platform that offers customized grippers and four-degree-of-freedom adjustment for Miniscope, along with software that integrates displacement control, image quality evaluation, and enhancement of 3D visualization. Our toolkit makes it feasible to accurately characterize Miniscope. Furthermore, MiniMounter enables auto-focusing and 3D imaging for Miniscope prototypes that possess solely a 2D imaging function, as demonstrated in phantom and animal experiments. Overall, the implementation of MiniMounter effectively enhances image quality, reduces the time required for experimental operations and image evaluation, and consequently accelerates the development and research cycle for both users and developers within the Miniscope community.


Assuntos
Neurociências , Software , Animais , Microscopia de Fluorescência , Comportamento Animal , Controle de Qualidade , Aumento da Imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA