Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Radiography (Lond) ; 30(3): 869-881, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38598886

RESUMO

INTRODUCTION: The SAFE EUROPE project, a European-funded project, addressed educational gaps of Therapeutic Radiographers/Radiation Therapists (TR/RTTs) by offering a series of free webinars. This study aimed to assess the quality of these webinars and their impact on professional practice. METHODS: Data collection involved two methods: an automated feedback form administered after each webinar, supplemented by a survey disseminated through social media. The collected data encompassed attendance statistics, participants' professions and geographic locations, webinar quality assessment, the acquisition of new knowledge and skills, the application of this newfound knowledge in practice, and the likelihood of recommending these webinars. Descriptive statistics and thematic analysis were used to analyse the quantitative and qualitative data, respectively. Ethical approval for the study was obtained. RESULTS: 11,286 individuals from 107 countries participated in 18 webinars. Despite 72.7% being radiographers, a diverse array of professionals attended the webinars, including medical physicists, oncologists, radiologists, and academics. Remarkably, 98.7% of respondents rated the webinar quality as either good or excellent. The average rating for the likelihood of recommending these webinars to colleagues was 8.96/10. A substantial proportion of respondents expressed agreement or strong agreement that the webinars enhanced their knowledge (85%) and skills (73%). Furthermore, 79% of participants indicated that the webinars motivated them to change practice, with 65% having already implemented these changes. The insights from open-ended questions corroborated these findings. CONCLUSION: The webinars effectively achieved the aim of the SAFE EUROPE project to enhance practice by increasing knowledge and skills. Participants overwhelmingly endorsed the quality of these webinars. IMPLICATIONS FOR PRACTICE: Webinars represent a cost-efficient training tool that reaches a global audience and various radiography/radiotherapy professions. The development of additional webinars is strongly recommended.


Assuntos
Educação a Distância , Humanos , Europa (Continente) , Educação a Distância/métodos , Inquéritos e Questionários , Internet , Radiologia/educação
2.
Radiography (Lond) ; 28(3): 663-667, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35623269

RESUMO

INTRODUCTION: Anti-scatter grids efficiently reduce scatter radiation from reaching the imaging receptor, enhancing image quality; however, the patient radiation dose increases in the process. There is disagreement regarding the thickness thresholds for which anti-scatter grids are beneficial. This study aims to establish a thickness threshold for the use of anti-scatter grids to optimise adult knee radiography. METHODS: The study consisted of two phases. In Phase 1 phantom knee radiographs were acquired at varying thicknesses (10-16 cm) and tube voltages (60-80 kV). For each thickness and tube voltage, images with and without an anti-scatter grid were obtained. In Phase 2, two radiologists and three radiographers, evaluated the image quality of these images. Visual Grading Analysis (VGA) scores were analysed using Visual Grading Characteristics (VGC) based on the visualisation of five anatomic criteria. RESULTS: The average DAP decreased by 72.1% and mAs by 73.1% when removing the anti-scatter grid. The VGC revealed that overall images taken with an anti-scatter grid have better image quality (AUC ≥0.5 for all comparisons). However, the anti-scatter grids could be removed for thicknesses 10, 12 and 14 cm in conjunction with using 80 kVp,. CONCLUSION: Anti-scatter grids can be removed when imaging adult knees between 10 and 12 cm using any kVp setting since the radiation dose is reduced without significantly affecting image quality. For thicknesses >12 cm, the use of anti-scatter grids significantly improves image quality; however, the radiation dose to the patient is increased. The exception is at 14 cm used with 80 kVp, where changes in image quality were insignificant. IMPLICATIONS FOR PRACTICE: Optimisation by removing anti-scatter grids in adult knee radiography seems beneficial below 12 cm thickness with any kVp value. Since the average knee thickness ranges between 10 and 13 cm, anti-scatter grid can be removed for most patients. Nevertheless, further studies are recommended to test if this phantom-based threshold applies to human subjects.


Assuntos
Imagens de Fantasmas , Adulto , Humanos , Radiografia , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...