Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros












Intervalo de ano de publicação
1.
Food Chem ; 458: 140184, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38968708

RESUMO

The public health concern of antibiotic residues in animal-origin food has been a long-standing issue. In this work, we present a novel method for antibiotic detection, leveraging optical weak value amplification and harnessing an indirect competitive inhibition assay, which significantly boosts the system's sensitivity in identifying small molecule antibiotics. We chose chloramphenicol as a model compound and mixed it with chloramphenicol-bovine serum albumin conjugates to bind to the chloramphenicol antibody competitively. We achieved a broad linear detection range of up to 3.24 ng/mL and a high concentration resolution of 33.20 pg/mL. To further validate the universality of our proposed detection methodology, we successfully applied it to testing gibberellin and tetracycline. Moreover, we conducted regeneration experiments and real-sample correlation studies. This study introduces a novel strategy for the label-free optical sensing of small molecule antibiotics, greatly expanding the range of applications for sensors utilizing optical weak value amplification.

2.
ACS Sens ; 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38943618

RESUMO

Allergy is a prevalent disease, and the potential allergic population is expanding with industrialization and changes in people's living standards. Serum immunoglobulin E (IgE) level is one of the critical indicators for determining allergy. Here, we proposed a simple, real-time monitoring, low chip cost, label-free aptamer biosensing strategy based on weak value amplification (WVA) for the quantitative detection of IgE in serum samples, enabling early and accurate diagnosis of allergic or hypersensitive patients. The aptasensor combined an imaging weak measurement system with the high specificity of the aptamer for the marker IgE. By modifying the amino group at the 3-terminal end, the anti-IgE aptamers can attach to a dopamine-modified prism's surface and selectively recognize IgE in human serum. In the presence of IgE, a specific binding reaction occurred, resulting in a change in the refractive index of the reactive region's surface, manifested as a change in the light intensity of the camera acquired experimental images. As the concentration of IgE increased, the relative light intensity advanced sequentially. The WVA-aptasensing strategy achieved a wide detection range of 0.01 ng/mL to 2 µg/mL in phosphate buffered saline buffer, with the resolution as low as 4.3 pg/mL. IgE testing experiments in human serum have proved the feasibility of our methods in detecting complex samples. In addition, the method specifically recognized IgE without interference from other proteins. We believe that our proposed sensing strategy opens up new possibilities for ultrahigh sensitivity screening of IgE and can be expanded to detecting other biomolecules.

3.
Talanta ; 277: 126302, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38830277

RESUMO

A label-free optical sandwich immunoassay sensor, utilizing weak value amplification and total internal reflection, was devised for real-time, high-sensitivity analysis and detection of low-concentration targets. 3D printed channels and sodium chloride solution were employed to ensure reproducibility, reliability, and stability of the measurements for calibration. The sandwich structure demonstrated enhanced responsiveness in the proposed optical biosensor through a comparative analysis of the direct assay and sandwich assay for detecting alpha-fetoprotein (AFP) at the same concentration. By optimizing the binding sequences of the coating antibody, target, and detection antibody in the sandwich method, a more suitable sandwich sensing approach based on weak value amplification was achieved. With this approach, the limit of detection (LOD) of 6.29 ng/mL (pM level) for AFP in PBS solution was achieved. AFP testing and regeneration experiments in human serum have proved the feasibility of our methods in detecting complex samples and the reusability of sensing chips. Additionally, the method demonstrated excellent selectivity for unpaired antigens. The efficacy of this methodology was evaluated by simultaneously detecting AFP, carcinoembryonic antigen (CEA), and CA15-3 on a singular sensor chip. In conclusion, the label-free sandwich immunoassay sensing scheme holds promise for advancing the proposed optical sensors based on weak value amplification in early diagnosis and prevention applications. Compared to other biomarker detection methods, it will be easier to promote in practical applications.

4.
BMC Pregnancy Childbirth ; 24(1): 420, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858685

RESUMO

BACKGROUND: Frontonasal dysplasia (FND) is a rare congenital anomaly resulting from the underdevelopment of the frontonasal process, and it can be syndromic or nonsyndromic. The typical features of FND include a deformed nose and ocular hypertelorism, which are sometimes associated with cleft lip and/or palate. Only approximately 10 cases of prenatally diagnosed nonsyndromic FND have been reported in the past 30 years. CASE PRESENTATION: A 33-year-old woman (G2P1) was referred to our center at 20 gestational weeks for bilateral hydrocephaly. We detected typical features of FND, including severe hypertelorism, median nasal bifidity, a minor cleft lip, and multiple limb anomalies using three-dimensional (3D) ultrasound. A hypoplastic corpus callosum, unilateral microtia, and a ventricular septal defect were also detected. Genetic testing, including karyotype analysis, copy number variation (CNV) analysis, trio-whole exome sequencing (trio-WES), and trio-whole-gene sequencing (trio-WGS), was performed; however, we did not find any de novo gene variants in the fetus as compared to the parents. Postmortem examination confirmed the prenatal diagnosis of FND. CONCLUSION: The present case expands the wide phenotypic spectrum of prenatal FND patients. 3D ultrasound is a useful tool for detecting facial and limb deformities.


Assuntos
Agenesia do Corpo Caloso , Anormalidades Craniofaciais , Face , Hidrocefalia , Imageamento Tridimensional , Deformidades Congênitas dos Membros , Ultrassonografia Pré-Natal , Humanos , Feminino , Adulto , Gravidez , Anormalidades Craniofaciais/diagnóstico por imagem , Agenesia do Corpo Caloso/diagnóstico por imagem , Agenesia do Corpo Caloso/genética , Deformidades Congênitas dos Membros/diagnóstico por imagem , Deformidades Congênitas dos Membros/genética , Face/anormalidades , Face/diagnóstico por imagem , Hidrocefalia/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/genética , Anormalidades Múltiplas/diagnóstico por imagem , Anormalidades Múltiplas/genética
5.
J Opt Soc Am A Opt Image Sci Vis ; 41(4): 631-642, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568663

RESUMO

Most of the state-of-the-art defogging models presented in the literature assume that the attenuation coefficient of all spectral channels is constant, which inevitably leads to spectral distortion and information bias. To address this issue, this paper proposes a defogging method that takes into account the difference between the extinction coefficients of multispectral channels of light traveling through fog. Then the spatially distributed transmission map of each spectral channel is reconstructed to restore the fog-degraded images. The experimental results of various realistic complex scenes show that the proposed method has more outstanding advantages in restoring lost detail, compensating for degraded spectral information, and recognizing more targets hidden in uniform ground fog than state-of-the-art technologies. In addition, this work provides a method to characterize the intrinsic property of fog expressed as multispectral relative extinction coefficients, which act as a fundament for further reconstruction of multispectral information.

6.
Front Chem ; 12: 1382251, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38524915

RESUMO

An ultra-sensitive phase plasmonic sensor combined with weak value amplification is proposed for the detection of IgG, as a model analyte. Phase detection is accomplished by self-interference between the p-polarization and the s-polarization of the light. With the principles of weak value amplification, a phase compensator is used to modulate the coupling strength and enhance the refractive index sensitivity of the system. On a simple Au-coated prism-coupled surface plasmon resonance (SPR) structure, the scheme, called WMSPR, achieves a refractive index sensitivity of 4.737 × 104 nm/RIU, which is about three times higher than that of the conventional phase-based approach. The proposed WMSPR biosensor gives great characteristics with a high resolution of 6.333 × 10-8 RIU and a low limit of detection (LOD) of 5.3 ng/mL. The results yield a great scope to promote the optimization of other SPR biosensors for high sensitivity.

7.
Opt Express ; 31(23): 38540-38549, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-38017957

RESUMO

Compared to other parts of the electromagnetic spectrum, the terahertz frequency range lacks efficient polarization manipulation techniques, which is impeding the proliferation of terahertz technology. In this work, we demonstrate a tunable and broadband linear-to-circular polarization converter based on an InSb plate containing a free-carrier magnetoplasma. In a wide spectral region (∼ 0.45 THz), the magnetoplasma selectively absorbs one circularly polarized mode due to electron cyclotron resonance and also reflects it at the edges of the absorption band. Both effects are nonreciprocal and contribute to form a near-zero transmission band with a high isolation of -36 dB, resulting in the output of a near-perfect circularly polarized terahertz wave for an incident linearly polarized beam. The near-zero transmission band is tunable with magnetic field to cover a wide frequency range from 0.3 to 4.8 THz.

8.
Talanta ; 257: 124217, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36801563

RESUMO

In this study, an interfacial biosensing scheme with ultra-precision is proposed. The scheme uses weak measurement techniques to ensure ultra-high sensitivity of the sensing system while improving the stability of the system through self-referencing and pixel point averaging, thus achieving ultra-high detection accuracy of biological samples. In specific experiments, we have used the biosensor in this study to perform specific binding reaction experiments for protein A and Mouse IgG with a detection line of 2.71 ng/mL for IgG. In addition, the sensor is non-coated, simple in structure, easy to operate, and low in cost of use.


Assuntos
Técnicas Biossensoriais , Animais , Camundongos , Técnicas Biossensoriais/métodos , Imunoglobulina G
9.
Opt Express ; 30(20): 35125-35135, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36258471

RESUMO

A quantitative understanding about the optical scattering of medium plays an important role in many common but important application fields including optical imaging, optical communication, and optical remote sensing. In this paper, two quantitative models about single scattering and multiple scattering were established based on the different polarization properties of these two scattering processes on the condition of paraxial approximation. The related approximate explicit functions about the light scattering characteristics through fog are solved. Moreover, on the basis of scattering models, the depolarization ratio of broad-band polarized light is also measured. The physical models are demonstrated very consistent with the experimental results and Monte Carlo simulations. These works greatly simplify previous models and have a significant promotion to the study of medium scattering characteristics.

10.
Front Chem ; 10: 880081, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35402379

RESUMO

Interferometry has been widely used in biosensing due to its ability to acquire molecular affinity and kinetics in real-time. However, interferometric-based sensors are susceptible to environmental disturbances, including temperature and non-specific binding of target molecules, which reduces their detection robustness. To address this shortcoming, this paper proposes a self-referencing interference sensor based on coherence multiplexing to resist environmental disturbances. The proposed sensor can address temperature and non-specific binding, but it is not limited only to these types of disturbances. In the proposed sensor design, each sensor signal is encoded using a specific optical path difference determined by the optical thickness of a sensor chip. In addition, two sensor signals for disturbances tracking and biomolecule detection are detected simultaneously without additional cost to the second spectrometer and then differenced to achieve real-time self-reference. The temperature fluctuations experiments and specific binding experiments of protein A to IgG are performed to verify the performance of the proposed sensor. The results demonstrate that the proposed sensor can eliminate non-specific binding and temperature disturbances in real-time during biomolecule detection, achieving higher detection robustness. The proposed sensor is suitable for applications that require large-scale testing of biomolecular interactions, such as drug screening.

11.
Opt Express ; 30(2): 957-965, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35209273

RESUMO

Reverse design is a frontier direction in the optical research field. In this work, reverse design is applied to the design of terahertz devices. We have employed direct binary search (DBS) and binary particle swarm optimization (BPSO) algorithms to design pixel-type terahertz band-pass filters, respectively. Through a comparative analysis of the designed devices, we found that BPSO algorithm converged faster than DBS algorithm, and the device performance is better on out-of-band suppression. We have fabricated a sample utilizing femtosecond laser micromachining and characterized it by terahertz time-domain spectroscopy. The experimental results were consistent with the finite difference time domain (FDTD) simulation. Our method can simultaneously optimize multiple characteristics of the band-pass filters, including the peak transmittance, out-of-band transmittance, bandwidth, and polarization stability, which can not be achieved by traditional optical design methods.

12.
Biomed Opt Express ; 12(8): 5128-5138, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34513246

RESUMO

Diabetes is an important public health problem and finding quick testing methods with high accuracy, reliability, and convenience are important to control the blood glucose of diabetic patients. In this study, a sensor based on a weak measurement scheme was developed for the specific detection of glucose for the first time. The detection of glucose using the proposed method was completed by the high sensitivity and resolution of the weak measurement based on optical rotation detection, as well as the change in the optical rotation before and after the specific oxidation of glucose. The resolution of the as-obtained glucose sensor was around 2.71×10-3 g/L (1.50×10-2 mmol/L), and the detection range was 0-11 g/L (0-61 mmol/L).

13.
Anal Chem ; 93(38): 12914-12920, 2021 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-34523343

RESUMO

Flow battery electrodes are vital for performing redox reactions, and an in-depth understanding of reaction kinetics and spatial distribution differences in electrodes is very important for improving the efficiency of electrochemical reactions. In this study, a reflection-type phase-sensitive weak measurement imaging system was developed for the detection of flow batteries. The phase difference between two polarization components in total internal reflection caused by electrode redox processes was measured by weak value amplification. The resulting refractive index resolution of the imaging system was estimated to be 2.8-4.2 × 10-6 RIU. The real-time monitoring ability of the system was demonstrated by linear sweep voltammetry tests of vanadium redox batteries. Compared to traditional optical methods, the proposed weak measurement imaging sensor did not require coating, as it can be used in acid electrolytes of vanadium flow batteries. Meanwhile, the weak value amplification effect led to a higher resolution than the total internal reflection system shown in our previous work, thereby resulting in more accurate detection of electrochemical reactions. In sum, the proposed sensor looks very promising for the detection of electrochemical reactions in flow batteries, water splitting, electrochemical corrosion, and electrocatalysis.


Assuntos
Fontes de Energia Elétrica , Eletrólitos , Eletrodos , Oxirredução , Vanádio
14.
J Ultrasound Med ; 39(3): 453-461, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31448445

RESUMO

OBJECTIVES: To investigate fetal hemodynamic alterations using transabdominal ultrasound in fetuses with isolated mild-to-moderate ventriculomegaly (VM). METHODS: Fetuses diagnosed with isolated mild-to-moderate VM by transabdominal ultrasound were evaluated for hemodynamic changes, including changes in fetal cardiac function, the umbilical artery, the ductus venosus, and the middle cerebral artery. The fetuses with isolated mild-to-moderate VM were divided into 2 groups, namely, before 32 weeks' gestation (20 weeks-31 weeks 6 days) and after 32 weeks' gestation (32-38 weeks), and matched to corresponding healthy control fetuses. RESULTS: The 53 fetuses with VM before 32 weeks had a longer mean isovolumetric relaxation time (IRT; mean ± SD, 42.9 ± 6.8 versus 40.4 ± 5.0 milliseconds; P < .05) and an apparently higher modified myocardial performance index 0.46 ± 0.06 versus 0.43 ± 0.05; P < .01) than the healthy control fetuses. The 43 fetuses with VM after 32 weeks had a significantly longer mean IRT (45.5 ± 6.7 versus 40.9 ± 7.2 milliseconds; P < .01) and a lower UA pulsatility index (0.81 ± 0.13 versus 0.89 ± 0.11; P < .01). The optimal cutoff levels for the IRT in the prediction of adverse perinatal outcomes were 40 and 43 milliseconds before and after 32 weeks, respectively (sensitivity, 100% versus 100%; specificity, 40.4% versus 50.0%; area under the curve, 0.601 versus 0.748; 95% confidence interval, 0.457-0.733 versus 0.590-0.869; P = .291 versus .005). CONCLUSIONS: Some fetuses with isolated mild-to-moderate VM may have impaired cardiac function, characterized by a higher modified myocardial performance index or longer IRT. This finding might be useful for improving fetal surveillance.


Assuntos
Coração Fetal/diagnóstico por imagem , Coração Fetal/fisiopatologia , Hemodinâmica/fisiologia , Hidrocefalia/embriologia , Hidrocefalia/fisiopatologia , Ultrassonografia Pré-Natal/métodos , Adulto , Estudos Transversais , Feminino , Coração Fetal/embriologia , Humanos , Hidrocefalia/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Índice de Gravidade de Doença , Ultrassonografia Doppler/métodos , Adulto Jovem
15.
Appl Opt ; 58(31): 8583-8588, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31873343

RESUMO

The ability to identify L(+)-ascorbic acid from D(-)-isoascorbic acid in medicinal products is of practical interest. Based on the method of frequency domain weak measurement, a set of common optical path sensors for identification of L(+)-ascorbic acid and D(-)-isoascorbic acid is established. By quantificationally analyzing the magnitude and offset direction of the spectral central wavelength, a good identification of the concentration and the optically active forms of ascorbic acid has been achieved. The sensitivity and resolution of the sensor for optical rotation can reach 34.35 nm/° and ${5.53} \times {{10}^{ - 5}}^\circ $5.53×10-5 ∘, respectively. The detection resolution for L(+)-ascorbic acid is ${2.00} \times {{10}^{ - 4}}\;{\rm mol}/{\rm mL}$2.00×10-4mol/mL, and that for D(-)-isoascorbic acid is ${2.73} \times {{10}^{ - 4}}\;{\rm mol}/{\rm mL}$2.73×10-4mol/mL. The potential of the sensor in the detection of transparent but optically inactive impurities has been verified by comparative experiments of sodium chloride solution. The sensor also has been applied to identify medicinal vitamin C tablets, which verified the feasibility of the method in optically active pharmaceutical solutions with water-insoluble, optically inactive impurities. Since the sensor has the advantages of high precision, real-time, high robustness, and being non-destructive, it has a great prospect in the field of drug detection containing chiral molecules.

16.
Rev Assoc Med Bras (1992) ; 65(8): 1055-1060, 2019 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-31531601

RESUMO

OBJECTIVE: This study aims to investigate the causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (TVS RT-3D-HyCoSy), in order to improve the diagnostic efficiency of TVS RT-3D-HyCoSy. METHODS: A total of 162 oviducts of 83 infertility patients were examined by TVS RT-3D-HyCoSy. These results were compared with the gold standard for laparoscopic dye studies, and the misdiagnosed cases were analyzed. RESULTS: TVS RT-3D-HyCoSy revealed that 68 oviducts were unobstructed and 94 obstructed. The results for the 144 oviducts were in line with the gold standard, while those for 18 oviducts were not. The accuracy rate of the TVS RT-3D-HyCoSy was 88.9%, and the misdiagnosis rate was 11.1%. The main causes of misdiagnosis included contrast medium countercurrent and diffusion, oviduct spasm, abnormal shape or position of the oviduct, pelvic adhesion, and poor imaging operation. CONCLUSION: TVS RT-3D-HyCoSy can well-evaluate tubal patency, and understand and improve the cause of misdiagnosis. Furthermore, the diagnostic efficiency of TVS RT-3D-HyCoSy can still be further improved.


Assuntos
Tubas Uterinas/diagnóstico por imagem , Infertilidade Feminina/diagnóstico por imagem , Adulto , Erros de Diagnóstico , Endossonografia , Testes de Obstrução das Tubas Uterinas/métodos , Feminino , Humanos , Histerossalpingografia , Imageamento Tridimensional , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem
17.
Prenat Diagn ; 39(12): 1086-1095, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31441071

RESUMO

OBJECTIVES: To quantitatively assess prenatal diagnostic performance of three-dimensional ultrasound (3D-US) for posterior fossa anomalies (PFA) and establish a preliminarily 3D-US prediction model. METHODS: Sixty singleton fetuses suspected of PFA by 2D-US presented their detailed 3D-US evaluation. The surface area of vermis (SAV), brainstem-vermis, and brainstem-tentorium angles were measured by 3D-US. The good prognosis was defined as normal neurodevelopmental outcome. MRI and autopsy were the diagnostic reference standard. RESULTS: There was a significant difference between 2D-US (60.0%, 36/60) and 3D-US (94.8%, 55/58) for the diagnostic accuracy (P < .01). Prenatal 3D-US prediction model was established with observed/expected SAV as the main predictor (area under the curve [AUC]: 0.901; 95% CI, 0.810-0.992, P < .001). When it was more than 107.5%, the prognosis seemed to be good (sensitivity: 96.4%, specificity: 26.7%), which led to consideration of mega cisterna magna, Blake pouch cyst, or small arachnoid cyst. The prognosis appeared to be poor when it was less than 73% (sensitivity: 71.4%, specificity: 100%), and the diagnosis tended to be a Dandy-Walker malformation, vermian hypoplasia, and cerebellar hypoplasia. Brainstem-vermis and brainstem-tentorium angles were the secondary indicators (AUC: 0.689 vs 0.761; 95% CI, 0.541-0.836 vs 0.624-0.897, P = .014 vs.001). CONCLUSIONS: It seems that the exact types of PFA can be effectively diagnosed by quantitative indicators of 3D-US.


Assuntos
Fossa Craniana Posterior/anormalidades , Fossa Craniana Posterior/diagnóstico por imagem , Imageamento Tridimensional/métodos , Modelos Estatísticos , Malformações do Sistema Nervoso/diagnóstico , Ultrassonografia Pré-Natal/métodos , Adulto , Autopsia , Fossa Craniana Posterior/patologia , Feminino , Feto/diagnóstico por imagem , Feto/patologia , Idade Gestacional , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Masculino , Malformações do Sistema Nervoso/patologia , Tamanho do Órgão , Valor Preditivo dos Testes , Gravidez , Resultado da Gravidez , Dados Preliminares , Prognóstico , Padrões de Referência , Ultrassonografia Pré-Natal/normas , Adulto Jovem
18.
Anal Chem ; 91(18): 11576-11581, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31407571

RESUMO

In this paper, we propose a linear differential detection system based on a frequency domain weak measurement. The system can be used for detecting optical substances. Moreover, we completed an experiment to detect himan serum albumin (HSA) content in a mixture of human serum albumin and l-proline via dialysis. This work also proves the differential function of the system. This experiment can be further extended to detecting protein content in a mixed solution that contains protein macromolecules and various small molecules. It is very important for detecting molecules without photomarking in solutions of complex biological samples. In this paper, the system has an optical resolution of 1.39 × 10-5, and resolution of 4.06 × 10-8 mol/L for himan serum protein solution.


Assuntos
Óptica e Fotônica/métodos , Albumina Sérica Humana/análise , Glucose/química , Humanos , Rotação Ocular , Prolina/química , Teoria Quântica
19.
Rev. Assoc. Med. Bras. (1992) ; 65(8): 1055-1060, Aug. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1041056

RESUMO

SUMMARY OBJECTIVE This study aims to investigate the causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography (TVS RT-3D-HyCoSy), in order to improve the diagnostic efficiency of TVS RT-3D-HyCoSy. METHODS A total of 162 oviducts of 83 infertility patients were examined by TVS RT-3D-HyCoSy. These results were compared with the gold standard for laparoscopic dye studies, and the misdiagnosed cases were analyzed. RESULTS TVS RT-3D-HyCoSy revealed that 68 oviducts were unobstructed and 94 obstructed. The results for the 144 oviducts were in line with the gold standard, while those for 18 oviducts were not. The accuracy rate of the TVS RT-3D-HyCoSy was 88.9%, and the misdiagnosis rate was 11.1%. The main causes of misdiagnosis included contrast medium countercurrent and diffusion, oviduct spasm, abnormal shape or position of the oviduct, pelvic adhesion, and poor imaging operation. CONCLUSION TVS RT-3D-HyCoSy can well-evaluate tubal patency, and understand and improve the cause of misdiagnosis. Furthermore, the diagnostic efficiency of TVS RT-3D-HyCoSy can still be further improved.


RESUMO OBJETIVO Este estudo tem como objetivo investigar as causas do diagnóstico equivocado na avaliação da patência tubária por meio da ultrassonografia de contraste histerosalpingo em tempo real transvaginal (TVS RT-3D-HyCoSy), a fim de melhorar a eficiência diagnóstica das TVS RT-3D-HyCoSy. MÉTODOS Um total de 162 ovidutos em 83 pacientes da infertilidade foi examinado por TVS RT-3D-HyCoSy. Esses resultados foram comparados com o padrão ouro para estudos de tintura laparoscópica, e os casos diagnosticados erroneamente foram analisados. RESULTADOS TVS RT-3D-HyCoSy revelaram que 68 ovidutos foram desobstruídos e 94 ovidutos foram obstruídos. Os resultados para os 144 ovidutos estavam em consonância com o padrão ouro, enquanto que aqueles para os 18 ovidutos, não. A taxa de acurácia do TVS RT-3D-HyCoSy foi de 88,9%, e a taxa de erro de diagnóstico foi de 11,1%. As principais causas de erro de diagnóstico incluíram contraponto e difusão do meio de contraste, espasmo do oviduto, forma ou posição anormal do oviduto, adesão pélvica e má operação de imagem. CONCLUSÃO TVS RT-3D-HyCoSy pode bem avaliar a patência tubária, e compreender e melhorar a causa do erro de diagnóstico. Além disso, a eficiência diagnóstica do TVS RT-3D-HyCoSy ainda pode ser melhorada.


Assuntos
Humanos , Feminino , Adulto , Adulto Jovem , Tubas Uterinas/diagnóstico por imagem , Infertilidade Feminina/diagnóstico por imagem , Histerossalpingografia , Fatores de Risco , Endossonografia , Imageamento Tridimensional , Erros de Diagnóstico , Testes de Obstrução das Tubas Uterinas/métodos , Pessoa de Meia-Idade
20.
Nat Commun ; 10(1): 1609, 2019 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-30962433

RESUMO

Bacterial degradation of organosulfonates plays an important role in sulfur recycling, and has been extensively studied. However, this process in anaerobic bacteria especially gut bacteria is little known despite of its potential significant impact on human health with the production of toxic H2S. Here, we describe the structural and biochemical characterization of an oxygen-sensitive enzyme that catalyzes the radical-mediated C-S bond cleavage of isethionate to form sulfite and acetaldehyde. We demonstrate its involvement in pathways that enables C2 sulfonates to be used as terminal electron acceptors for anaerobic respiration in sulfate- and sulfite-reducing bacteria. Furthermore, it plays a key role in converting bile salt-derived taurine into H2S in the disease-associated gut bacterium Bilophila wadsworthia. The enzymes and transporters in these anaerobic pathways expand our understanding of microbial sulfur metabolism, and help deciphering the complex web of microbial pathways involved in the transformation of sulfur compounds in the gut.


Assuntos
Acetiltransferases/metabolismo , Proteínas de Bactérias/metabolismo , Desulfovibrio/metabolismo , Sulfeto de Hidrogênio/toxicidade , Taurina/metabolismo , Acetiltransferases/genética , Acetiltransferases/isolamento & purificação , Proteínas de Bactérias/genética , Proteínas de Bactérias/isolamento & purificação , Ácidos e Sais Biliares/metabolismo , Bilophila/metabolismo , Ensaios Enzimáticos , Microbioma Gastrointestinal/fisiologia , Sulfeto de Hidrogênio/metabolismo , Mucosa Intestinal/metabolismo , Mucosa Intestinal/microbiologia , Mercaptoetanol/análogos & derivados , Mercaptoetanol/metabolismo , Redes e Vias Metabólicas/fisiologia , Proteínas Recombinantes/genética , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/metabolismo , Enxofre/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...