Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Talanta ; 136: 183-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25703001

RESUMO

A simple, specific and reproducible liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of pyraoxystrobin in rat plasma and tissues. Chromatographic separation was achieved on a Zorbax Extend-C18 column (50×2.1mm I. D., 3.5µm), using a gradient mobile phase consisting of acetonitrile and 0.1% aqueous formic acid (v/v) at a flow rate of 0.5mL min(-1). Pyraoxystrobin and picoxystrobin (internal standard) were detected without interference in the selected reaction monitoring (SRM) mode with positive electrospray ionization. Further, the method was validated following FDA guideline. The calibration curves for plasma and tissues were linear over a concentration range of 1.00-200ng mL(-1), with lower limits of quantitation of 1.00ng mL(-1). Mean extraction recoveries in plasma and tissues ranged from 101.4% to 108.2% and from 49.1% to 59.4%, respectively. The intra-day and inter-day precision in plasma and tissues were within 9.9% and 8.9%, and the intra-day and inter-day accuracy ranged from 88.7% to 110.7% and 93.2% to 108.7%, respectively. Finally, the validated method was successfully applied to toxicokinetics and tissue distribution studies after oral administration of pyraoxystrobin to rats.


Assuntos
Acrilatos/análise , Fungicidas Industriais/análise , Pirazóis/análise , Acrilatos/sangue , Acrilatos/farmacocinética , Acrilatos/toxicidade , Animais , Cromatografia Líquida de Alta Pressão , Fungicidas Industriais/sangue , Fungicidas Industriais/farmacocinética , Fungicidas Industriais/toxicidade , Masculino , Pirazóis/sangue , Pirazóis/farmacocinética , Pirazóis/toxicidade , Ratos Sprague-Dawley , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem , Distribuição Tecidual , Toxicocinética
2.
J Electron Microsc (Tokyo) ; 57(1): 1-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18083975

RESUMO

In this work, a detailed TEM sample preparation recipe based on a wedge polishing technique for GaN-based materials is presented. The obtained samples have atomically flat surfaces without any obvious surface damages such as the formation of amorphous layers. A composition estimation of Al(x)Ga(1-x)N from Z-contrast STEM imaging is carried out using these samples. The results are in good accord with the nominal composition.


Assuntos
Alumínio/química , Gálio/química , Microscopia Eletrônica de Transmissão/métodos , Manejo de Espécimes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...