Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Endod ; 49(12): 1682-1689.e4, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37816431

RESUMO

INTRODUCTION: This study aimed to compare the curvature severity of mesio-buccal (MB) canals between sagittal and coronal planes using cone-beam computed tomography. METHODS: In a Brazilian subpopulation, untreated MB1 (n = 141) and MB2 (n = 72) with single curvatures in sagittal and coronal planes were measured to determine their angle and radius (r), plus the prevalence of S-shaped canals was recorded. Curvature severity was defined according to the American Association of Endodontists Case Difficulty Assessment form (AAE) and EndoApp (EA), as well as their modified versions that consider angle and radii (AAE-r, EA-r). Data were converted into mean angle and r, percentage of canals >30°, AAE, EA, AAE-r and EA-r categories. The influence of r on case severity was assessed. Statistical analysis was performed using t-tests and chi-squared tests. The level of significance was set as P ≤ .05. RESULTS: For single curvatures, significantly higher mean degrees (SD) angles were found in the sagittal views in both canals (MB1 sagittal: 35 [11]; MB1 coronal: 13 [13]; MB2 sagittal: 29 [14]; MB2 coronal: 22 [15] [P < .05]). A greater percentage of angles >30° (MB1: 56.7% vs 6.4%; MB2: 44.4% vs 22.2%) in sagittal planes compared to coronal planes was also found. Conversely, a higher prevalence of S-shaped canals (MB1: 33.3% vs 7.1% MB2: 31.9% vs 15.3%) was observed in coronal planes. Significant differences between AAE and AAE-r were present with greater case severity when radii were considered (P < .05). CONCLUSIONS: Sagittal planes were associated with more severe single curvatures, while coronal planes had a greater prevalence of S-shaped canals.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Estudos Transversais , Brasil , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos
2.
Aust Endod J ; 49(3): 512-523, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37439393

RESUMO

There is insufficient research to evaluate social media's influence on endodontic education. Therefore, this study assessed the percentage of students utilising Facebook in their education and the factors influencing their engagement. A survey was conducted on dental students, interns and dentists undertaking specialist programmes. Categorical data were analysed using Fisher's Exact test and multiple pairwise comparisons. The significance level was set at p < 0.05. Responses were received from 801 participants, with 98.4% using Facebook for endodontic knowledge. Although most students knew that scientific evidence is not always provided, they still deemed such information valuable as it was a practical demonstration of clinical cases. Most students turn to Facebook for endodontic education to compensate for the gap between their academic education and clinical practice. The utilisation of social media for education can be a concerning phenomenon and should not be ignored by academic institutes.


Assuntos
Mídias Sociais , Humanos , Estudantes , Inquéritos e Questionários
3.
Aust Endod J ; 49(3): 503-511, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37403810

RESUMO

This study assessed the antimicrobial effect of sodium hypochlorite (NaOCl) mixtures combined with Keratobacter (KB) using an engineered biofilm root canal model. Clinical and reagent grade NaOCl were mixed with KB (9:1-vol/vol) to assess pH values over 1 min to select the ideal solution with a pH just below the pKa of hypochlorous acid. The samples were randomly divided into five groups: 1% and 4% NaOCl reagents, a mixture of NaOCl:KB using 1% and 4% NaOCl reagents and distilled water. Outcome measures were colony-forming units (CFUs/mL) and positive/negative cultures. No significant differences were observed in the pairwise comparisons between 1%, 4% NaOCl and 4% NaOCl+KB for the outcome CFUs/mL. Only 4% NaOCl presented with negative cultures in all samples, whereas 1% NaOCl and 4% NaOCl+KB had similar results (54% vs. 40%). The addition of KB has a limited effect on the antimicrobial efficacy of 4% NaOCl in this laboratory model.


Assuntos
Anti-Infecciosos , Hipoclorito de Sódio , Hipoclorito de Sódio/farmacologia , Ácido Glicocólico/farmacologia , Anti-Infecciosos/farmacologia , Ácido Hipocloroso/farmacologia , Biofilmes , Irrigantes do Canal Radicular/farmacologia , Cavidade Pulpar , Enterococcus faecalis , Preparo de Canal Radicular/métodos
4.
J Endod ; 49(7): 909-914, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37149086

RESUMO

INTRODUCTION: This study aimed to calculate the correlation between the radiopacity levels of various intracanal medicaments and radiolucent streak formation using cone-beam computed tomography (CBCT). METHODS: Seven commercially-available intracanal medicaments were tested, which contained different amounts of radiopacifier [Consepsis, Ca(OH)2, UltraCal XS, Calmix, Odontopaste, Odontocide, and Diapex Plus]. Their radiopacity levels were measured according to the International Organization for Standardization 13116 testing standards (mmAl). Subsequently, the medicaments were placed in 3 canals of radiopaque artificial printed maxillary molars (n = 15 roots per medicament), leaving the second mesiobuccal canal empty. CBCT imaging was carried out using an Orthophos SL 3-dimensional scanner under recommended manufacturer exposure settings. Radiopaque streak formation was assessed by a calibrated examiner using a previously published grading system (0-3). The Kruskal-Wallis and Mann-Whitney U tests with and without Bonferroni correction were used to compare radiopacity levels and radiopaque streak scores for the medicaments. Their relationship was assessed using the Pearson correlation coefficient. The level of significance was set as (α = 0.05). RESULTS: Diapex plus presented with the highest radiopacity levels (4.98 ± 0.01) and radiopaque streak scores [middle third (2.8 ± 0.18); apical third (2.73 ± 0.43)]; which was similar to UltraCal XS's radiopaque streak scores [middle third (2.8 ± 0.92); apical third (2.73 ± 0.77)]. Consepsis had the lowest radiopacity levels (0.12 ± 0.05), followed by Odontocide (0.60 ± 0.05). Consepsis and Ca(OH)2 were scored 0 for artifacts in all roots at all levels. A high positive correlation (R = 0.95) was found between radiopacity and streak formation. CONCLUSIONS: The radiopacity of intracanal medicaments varies and strongly correlates with the formation of radiolucent streak artifacts during CBCT.


Assuntos
Artefatos , Hidróxido de Cálcio , Cavidade Pulpar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos
5.
J Endod ; 49(5): 567-574, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36965769

RESUMO

INTRODUCTION: This study investigated the effect of shaping parameters of 2 different configurations of middle mesial canals (MMCs) on the biomechanical behavior and life span of a mandibular first molar using finite element analysis (FEA). METHODS: A mandibular molar with an independent MMC and another with a confluent MMC were scanned via micro-computed tomography, and FEA models were produced. For each tooth, an intact model and 5 experimental models were produced that differed by parameters of how the MMC was shaped: unshaped MMC, 25/.04, 25/.06, 30/.04, and 30/.06. Cyclic loading of 50 N was applied on the occlusal surface in vertical and oblique scenarios, and the number of cycles until failure (NCF) was compared with the intact models. In addition, mathematical analyses evaluated the stress distribution patterns and calculated maximum von Mises and maximum principal stresses. RESULTS: For both the independent and confluent MMC models, shaping the MMC reduced the NCF. The lifelog percentage of models was inversely proportional with radicular shaping parameters during the vertical and oblique loading scenarios. The shaping size of 30/.06 resulted in lower lifelog percentage than the cases with shaping size of 25/.04 in both of the independent and confluent MMC models. For all models, oblique loading reduced NCF more than vertical loading. CONCLUSION: Shaping the MMC should be kept as conservative as 25/.04. Also, whether the MMC is independent or confluent is a deciding factor in whether to increase the apical diameter or the root canal taper when larger shaping parameters are needed.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Análise de Elementos Finitos , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Mandíbula
6.
Aust Endod J ; 49(2): 247-255, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35830370

RESUMO

Cone-beam computed tomography (CBCT) is an increasingly used imaging modality. This study aimed to identify the factors that predict its usage amongst endodontists in Australia and New Zealand and describe usage characteristics. Data were collected via an online questionnaire, with analysis including descriptive statistics, cross-tabulation and multifactorial modelling. Ninety-four endodontists completed the questionnaire who were using CBCT for 7 years (median), over half had a CBCT unit in practice, with most prescribing up to 10 scans/month and 55 using a small field of view. Sixty-eight participated in >5 h of CBCT education/year and a third received a specialist-prepared report. The number of prescriptions/month was significantly associated with on-site CBCT units (Exp B: 8.53; 95% CI: 1.46-49.86, p < 0.05) and the number of years of CBCT usage by participants (Exp B: 1.46; 95% CI: 1.17-1.84, p = 0.001). CBCT imaging in endodontics is a useful diagnostic aid to decision making and treatment planning, with widespread acceptance and usage.


Assuntos
Endodontia , Endodontistas , Humanos , Nova Zelândia , Tomografia Computadorizada de Feixe Cônico , Austrália
7.
Materials (Basel) ; 14(11)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200233

RESUMO

This study aimed to compare the density of mineral trioxide aggregate (MTA) as a root canal filling material in the apical 5 mm of artificial root canals. Forty transparent acrylic blocks with 30-degree curved canals were instrumented and allocated into four compaction technique groups (n = 10): Lawaty (hand files); gutta-percha (GP) points; auger (nickel-titanium rotary files in reverse mode); and plugger technique. Filled canals were weighed after setting the MTA to calculate difference in mass. Two postoperative radiographs compared radiopacity by measuring luminance variations at 0.5 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm from the root apex. Obturation time was measured using a digital chronometer. The significance level was set to p < 0.05. The plugger group had a lower mass. Relative luminance was significantly higher for the Lawaty group than the plugger group at all examined apical levels. The relative luminance of the auger and GP groups were significantly higher than the plugger group at depths between 0.5 mm and 2 mm. Relative luminance was highest for the Lawaty technique at all depths between 0.5 mm and 4 mm. The Lawaty technique group was associated with increased obturation time compared with pluggers. Compacting MTA in curved canals with the Lawaty technique has the highest mass and radiopacity but requires more time.

8.
J Vet Dent ; 38(1): 34-45, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34192968

RESUMO

Vital pulp therapy (VPT) and direct pulp capping (DPC) are procedures regularly performed in dogs for the management of acute tooth fractures and as part of management for traumatic malocclusions. The purpose of this review is to apply an evidence-based medicine approach to systematically review and evaluate the scientific literature evaluating the efficacy of mineral trioxide aggregate (MTA) to other commercially available materials used for VPT in the permanent teeth of dogs. The 9 studies meeting inclusion criteria were reviewed and each studies evidence was classified using a grading system modified from the Oxford Centre for Evidence-Based Medicine. For the studies meeting inclusion criteria, MTA consistently performed as well or better than other commercially available products in terms of calcific barrier formation and biocompatibility. This review found a lack of consistency between the studies making a direct comparison of the results unreliable. Future studies would benefit from the implementation of a standard scoring system for histology, equivalent and longer study duration times and the correlation of histological and radiographic data.


Assuntos
Agentes de Capeamento da Polpa Dentária e Pulpectomia , Compostos de Alumínio/uso terapêutico , Animais , Compostos de Cálcio/uso terapêutico , Capeamento da Polpa Dentária/veterinária , Cães , Combinação de Medicamentos , Óxidos , Silicatos
9.
J Endod ; 47(9): 1472-1480, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34139264

RESUMO

INTRODUCTION: This study investigated the impact of different canal tapers and access cavity designs on the life span of endodontically treated mandibular first molars using the finite element method. METHODS: Finite element analysis was performed on simulated models with 3 access cavity designs (traditional, conservative, and truss). The mesial canals were prepared to either constant tapers of 25/.04 and 25/.06 or a variable taper corresponding to the cumulative canal preparation shapes of TruNatomy Prime (Dentsply Sirona, Charlotte, NC) and ProTaper Gold F2 (Dentsply Sirona). The distal canals in all models had a 40/.04 preparation. Using occlusal fingerprint analysis, all models were subjected to cyclic occlusal loading until model failure. The number of cycles until failure, the location of failure, stress distribution patterns, and the maximum von Mises stresses were assessed. RESULTS: The traditional access models showed a lower life span than the conservative and truss models regardless of the canal taper, whereas there was not a notable difference in the conservative and truss models. The stresses migrated apically along the root surface and remarkably on the mesial aspect of the mesial root and the furcation area's outer surface. After root canal preparation with different tapers, there were no evident changes in the pattern and magnitude of the stresses distributed along the root surface. CONCLUSIONS: The life span of the tooth is affected more significantly by the access cavity design than the root canal preparation taper. Because stress patterns migrate apically rather than concentrate in the pericervical area, crack initiation and propagation might occur anywhere on the root surface.


Assuntos
Longevidade , Dente Molar , Cavidade Pulpar , Análise de Elementos Finitos , Preparo de Canal Radicular
10.
Dent Traumatol ; 37(3): 510-520, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33713538

RESUMO

Over the past eight years, there have been marked changes in the recommendations for the management of traumatic dental injuries (TDIs). The recently published International Association of Dental Traumatology (IADT) guidelines for the emergency management of TDIs provide a comprehensive manual for clinicians to refer when assessing and managing patients presenting with these types of injuries. Clinicians should be prepared to utilize these new guidelines which were released in 2020. The aim of this short communication is to support those with previous knowledge regarding the IADT guidelines, to identify the changes in treatment modality, and to provide backing for those exposed to trauma guidelines for the first time. In the present communication, the areas of TDIs have been separated into primary and permanent teeth plus avulsions, with a tabular format highlighting the main changes in the emergency management from the previous version in 2012. This format has been devised to aid the clinicians' understanding of the variations over time and facilitate recall of the new guidelines. For the first time, the 2020 IADT Guidelines present a Core Outcomes Set (COS) that includes outcomes that were relevant to all TDIs and outcomes related to only one or several TDIs. However, the COS is not the object of the present publication.


Assuntos
Avulsão Dentária , Fraturas dos Dentes , Traumatismos Dentários , Traumatologia , Dentição Permanente , Tratamento de Emergência , Humanos , Traumatismos Dentários/terapia
11.
J Endod ; 47(5): 836-843, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33387551

RESUMO

The preparation of severely curved S-shaped double-curved root canals can be technically challenging. A novel root canal instrumentation technique is proposed, which modifies 2 techniques: the McSpadden crown-down technique and the tactile controlled activation technique. In the McSpadden crown-down technique, the root canal is divided into 2 portions: the coronal zone and the apical zone. However, rather than focusing on the length of file engagement, a formula is proposed to calculate the maximum insertion depths of higher tapered instruments to prevent overflaring of the canal and preserve pericervical dentin. Tactile-controlled activation involves activating martensitic nickel-titanium rotary files upon engagement and then immediately withdrawing the files. The proposed technique recommends 3 apical strokes after the initial engagement before withdrawal to minimize instrumentation time. This novel technique is described in a case report involving the management of an S-shaped double-curved maxillary lateral incisor. The technique presents a new method of crown-down instrumentation that prevents overflaring and avoids instrument separation.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Coroas , Ligas Dentárias , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Humanos , Dente Molar , Tratamento do Canal Radicular , Titânio
12.
Acta Biomater Odontol Scand ; 2(1): 7-11, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27335899

RESUMO

Objective Mineral trioxide aggregate (MTA) cements contain two types of particles, namely Portland cement (PC) (nominally 80% w/w) and bismuth oxide (BO) (20%). This study aims to determine the particle size distribution (PSD) of PC and BO found in MTA. Materials and methods The PSDs of ProRoot MTA (MTA-P) and MTA Angelus (MTA-A) powder were determined using laser diffraction, and compared to samples of PC (at three different particle sizes) and BO. The non-linear least squares method was used to deconvolute the PSDs into the constituents. MTA-P and MTA-A powders were also assessed with scanning electron microscopy. Results BO showed a near Gaussian distribution for particle size, with a mode distribution peak at 10.48 µm. PC samples milled to differing degrees of fineness had mode distribution peaks from 19.31 down to 4.88 µm. MTA-P had a complex PSD composed of both fine and large PC particles, with BO at an intermediate size, whereas MTA-A had only small BO particles and large PC particles. Conclusions The PSD of MTA cement products is bimodal or more complex, which has implications for understanding how particle size influences the overall properties of the material. Smaller particles may be reactive PC or unreactive radiopaque agent. Manufacturers should disclose particle size information for PC and radiopaque agents to prevent simplistic conclusions being drawn from statements of average particle size for MTA materials.

13.
Acta Biomater Odontol Scand ; 2(1): 25-30, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28642908

RESUMO

Objective The current standard used to measure setting time for Mineral Trioxide Aggregate (MTA) involves indentation testing with arbitrary weights. This study compared indentation testing against rheological measurements and assessed the influences of particle size and the inclusion of bismuth oxide on the setting time of experimental MTA and Portland cement (PC). Material and methods Two PCs (P1 and P2) of different particle sizes were produced using the same clinker. From these two PCs, two experimental MTAs (M1 and M2) were created with the addition of bismuth oxide. Particle size distributions were assessed using laser diffraction analysis. Indentation setting time tests were performed in accordance to the Gillmore needle test. Elastic modulus was assessed using a strain-controlled rheometer at 1 rad s-1 and an applied strain of 0.01%. Results P1, P2, M1 and M2 cements had median particle sizes of 6.1, 12.5, 6.5 and 13.0 µm, respectively. Using indentation testing, final setting times were ranked P1 < M1 < P2 < M2. The ranking of the final setting time corresponded with the rheological assessment of time required to reach 95% of the elastic modulus plateau. Conclusions The time to reach 95% elastic modulus plateau of 9.3 min corresponds to a time close to the point where the material can be overlaid with another restorative material to give a final restoration. The 95% plateau value for elastic modulus may be a more useful parameter for determining how the setting reaction of PC and MTA cements progress over time.

14.
Acta Biomater Odontol Scand ; 2(1): 130-137, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28642923

RESUMO

Objectives: To assess the effects on curing conditions (dry versus submerged curing) and particle size on the compressive strength (CS) and flexural strength (FS) of set MTA cement. Materials and methods: Two different Portland cements were created, P1 and P2, with P1 < P2 in particle size. These were then used to create two experimental MTA products, M1 and M2, with M1 < M2 in particle size. Particle size analysis was performed according to ISO 13320. The particle size at the 90th percentile (i.e. the larger particles) was P1: 15.2 µm, P2: 29.1 µm, M1: 16.5 µm, and M2: 37.1 µm. M2 was cured exposed to air, or submerged in fluids of pH 5.0, 7.2 (PBS), or 7.5 for 1 week. CS and FS of the set cement were determined using a modified ISO 9917-1 and ISO 4049 methods, respectively. P1, P2, M1 and M2 were cured in PBS at physiological pH (7.2) and likewise tested for CS and FS. Results: Curing under dry conditions gave a significantly lower CS than when cured in PBS. There was a trend for lower FS for dry versus wet curing. However, this did not reach statistical significance. Cements with smaller particle sizes showed greater CS and FS at 1 day than those with larger particle sizes. However, this advantage was lost over the following 1-3 weeks. Conclusions: Experiments that test the properties of MTA should cure the MTA under wet conditions and at physiological pH.

SELEÇÃO DE REFERÊNCIAS