RESUMO
PURPOSE: To evaluate the feasibility of CT angiography-derived fractional flow reserve (CT-FFR) calculations on ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT series and to intra-individually compare the results with energy-integrating (EID)-CT measurements. METHOD: Prospective patients with calcified plaques detected on EID-CT between April 1st, 2023 and January 31st, 2024 were recruited for a UHR CCTA on PCD-CT within 30 days. PCD-CT was performed using the same or a lower CT dose index and an equivalent volume of contrast media. An on-site machine learning algorithm was used to obtain CT-FFR values on a per-vessel and per-patient basis. For all analyses, CT-FFR values ≤ 0.80 were deemed to be hemodynamically significant. RESULTS: A total of 34 patients (age: 67.3 ± 6.6 years, 7 women [20.6 %]) were included. Excellent inter-scanner agreement was noted for CT-FFR values in the per-vessel (ICC: 0.93 [0.90-0.95]) and per-patient (ICC: 0.94 [0.88-0.97]) analysis. PCD-CT-derived CT-FFR values proved to be higher compared to EID-CT values on both vessel (0.58 ± 0.23 vs. 0.55 ± 0.23, p < 0.001) and patient levels (0.73 ± 0.23 vs. 0.70 ± 0.22, p < 0.001). Two patients (5.9 %) with hemodynamically significant lesions on EID-CT were reclassified as non-significant on PCD-CT. All remaining participants were classified into the same category with both scanner systems. CONCLUSIONS: While UHR CT-FFR values demonstrate excellent agreement with EID-CT measurements, PCD-CT produces higher CT-FFR values that could contribute to a reclassification of hemodynamic significance.
RESUMO
BACKGROUND: Advanced imaging techniques play a pivotal role in oncology. A large variety of computed tomography (CT) scanners, scan protocols, and acquisition techniques have led to a wide range in image quality and radiation exposure. This study aims at implementing verifiable oncological imaging by quality assurance and optimization (i-Violin) through harmonizing image quality and radiation dose across Europe. METHODS: The 2year multicenter implementation study outlined here will focus on CT imaging of lung, stomach, and colorectal cancer and include imaging for four radiological indications: diagnosis, radiation therapy planning, staging, and follow-up. Therefore, 480 anonymized CT data sets of patients will be collected by the associated university hospitals and uploaded to a repository. Radiologists will determine key abdominopelvic structures for image quality assessment by consensus and subsequently adapt a previously developed lung CT tool for the objective evaluation of image quality. The quality metrics will be evaluated for their correlation with perceived image quality and the standardized optimization strategy will be disseminated across Europe. RESULTS: The results of the outlined study will be used to obtain European reference data, to build teaching programs for the developed tools, and to create a culture of optimization in oncological CT imaging. CONCLUSION: The study protocol and rationale for iViolin, a European approach for standardization and harmonization of image quality and optimization of CT procedures in oncological imaging, is presented. Future results will be disseminated across all EU member states, and iViolin is thus expected to have a sustained impact on CT imaging for cancer patients across Europe.
RESUMO
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P<0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P<0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Humanos , Estenose Coronária/diagnóstico por imagem , Masculino , Feminino , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Vasos Coronários/diagnóstico por imagem , Fótons , Índice de Gravidade de Doença , Calcificação Vascular/diagnóstico por imagemRESUMO
BACKGROUND: Lower extremity peripheral artery disease frequently presents with calcifications which reduces the accuracy of computed tomography (CT) angiography, especially below-the-knee. Photon-counting detector (PCD)-CT offers improved spatial resolution and less calcium blooming. We aimed to identify the optimal reconstruction parameters for PCD-CT angiography of the lower legs. METHODS: Tubes with different diameters (1-5 mm) were filled with different iodine concentrations and scanned in a water container. Images were reconstructed with 0.4 mm isotropic resolution using a quantitative kernel at all available sharpness levels (Qr36 to Qr76) and using different levels of quantum iterative reconstruction (QIR-2-4). Noise and image sharpness were determined for all reconstructions. Additionally, CT angiograms of 20 patients, reconstructed with a medium (Qr44), sharp (Qr60), and ultrasharp (Qr72) kernel at QIR-2-4, were evaluated by three readers assessing noise, delineation of plaques and vessel walls, and overall quality. RESULTS: In the phantom study, increased kernel sharpness led to higher image noise (e.g., 16, 38, 77 HU for Qr44, Qr60, Qr72, and QIR-3). Image sharpness increased with increasing kernel sharpness, reaching a plateau at the medium-high level 60. Higher QIR levels decreased image noise (e.g., 51, 38, 25 HU at QIR-2-4 and Qr60) without reducing vessel sharpness. The qualitative in vivo results confirmed these findings: the sharp kernel (Qr60) with the highest QIR yielded the best overall quality. CONCLUSION: The combination of a sharpness level optimized reconstruction kernel (Qr60) and the highest QIR level yield the best image quality for PCD-CT angiography of the lower legs when reconstructed at 0.4-mm resolution. RELEVANCE STATEMENT: Using high-resolution PCD-CT angiography with optimized reconstruction parameters might improve diagnostic accuracy and confidence in peripheral artery disease of the lower legs. KEY POINTS: Effective exploitation of the potential of PCD-CT angiography requires optimized reconstruction parameters. Too soft or too sharp reconstruction kernels reduce image quality. The highest level of quantum iterative reconstruction provides the best image quality.
Assuntos
Angiografia por Tomografia Computadorizada , Imagens de Fantasmas , Fótons , Angiografia por Tomografia Computadorizada/métodos , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Masculino , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Feminino , Idoso , Pessoa de Meia-IdadeRESUMO
Preliminary work has shown that portal hypertension plays a key role for the prognosis in patients with hepatocellular carcinoma (HCC) undergoing transarterial chemoembolization (TACE). Specifically, the presence of ascites appears to be a strong negative predictor for these patients. However, it remains unclear whether different ascites volumes influence prognosis. Therefore, the aim of this work was to investigate the influence of different ascites volumes on survival for patients with HCC undergoing TACE. A total of 327 treatment-naïve patients with HCC undergoing initial TACE at our tertiary care center between 2010 and 2020 were included. In patients with ascites, the fluid was segmented, and the volume quantified by slice-wise addition using contrast-enhanced CT imaging. Median overall survival (OS) was calculated and univariate and multivariate Cox regression analysis has been performed. Ascites was present in 102 (31.9%) patients. Ascites volume as continuous variable was significantly associated with an increased hazard ratio in univariate analysis (p < 0.001) and remained an independent predictor of impaired median OS in multivariate analysis (p < 0.001). Median OS without ascites was 17.1 months, and therefore significantly longer than in patients with ascites (6.4 months, p < 0.001). When subdivided into groups of low and high ascites volume in relation to the median ascites volume, patients with low ascites volume had a significantly longer median OS (8.6 vs 3.6 months, p < 0.001). Ascites in patients with HCC undergoing TACE is strongly associated with a poor prognosis. Our results show that not only the presence but also the amount of ascites is highly relevant. Therefore, true ascites volume as opportunistic quantitative biomarker is likely to impact clinical decision-making once automated solutions become available.
Assuntos
Ascite , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/complicações , Quimioembolização Terapêutica/métodos , Ascite/terapia , Ascite/mortalidade , Ascite/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes CMR reports from 396 patients with suspected myocarditis and eight centers, respectively. CMR reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and radiologists with 1 (resident 1), 2 (resident 2), and 4 years (resident 3) of experience in CMR and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of Generative pre-trained transformer 4 (GPT-4) and the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in CMR). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p = 0.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p = 0.007 and R3: 91%, 85%, 96%, p < 0.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for residents 1 and 3 with statistical significance (p = 0.004 and p = 0.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on CMR reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision-supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.
RESUMO
Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.
Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de ContrasteRESUMO
Structured reporting (SR) not only offers advantages regarding report quality but, as an IT-based method, also the opportunity to aggregate and analyze large, highly structured datasets (data mining). In this study, a data mining algorithm was used to calculate epidemiological data and in-hospital prevalence statistics of pulmonary embolism (PE) by analyzing structured CT reports.All structured reports for PE CT scans from the last 5 years (n = 2790) were extracted from the SR database and analyzed. The prevalence of PE was calculated for the entire cohort and stratified by referral type and clinical referrer. Distributions of the manifestation of PEs (central, lobar, segmental, subsegmental, as well as left-sided, right-sided, bilateral) were calculated, and the occurrence of right heart strain was correlated with the manifestation.The prevalence of PE in the entire cohort was 24% (n = 678). The median age of PE patients was 71 years (IQR 58-80), and the sex distribution was 1.2/1 (M/F). Outpatients showed a lower prevalence of 23% compared to patients from regular wards (27%) and intensive care units (30%). Surgically referred patients had a higher prevalence than patients from internal medicine (34% vs. 22%). Patients with central and bilateral PEs had a significantly higher occurrence of right heart strain compared to patients with peripheral and unilateral embolisms.Data mining of structured reports is a simple method for obtaining prevalence statistics, epidemiological data, and the distribution of disease characteristics, as demonstrated by the PE use case. The generated data can be helpful for multiple purposes, such as for internal clinical quality assurance and scientific analyses. To benefit from this, consistent use of SR is required and is therefore recommended. · SR-based data mining allows simple epidemiologic analyses for PE.. · The prevalence of PE differs between outpatients and inpatients.. · Central and bilateral PEs have an increased risk of right heart strain.. · Jorg T, Halfmann MC, Graafen D et al. Structured reporting for efficient epidemiological and in-hospital prevalence analysis of pulmonary embolisms. Fortschr Röntgenstr 2024; DOI 10.1055/a-2301-3349.
RESUMO
PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.
Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Masculino , Feminino , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , AlgoritmosRESUMO
PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.
Assuntos
Imagem Cinética por Ressonância Magnética , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Átrios do Coração , Variações Dependentes do Observador , Função Ventricular EsquerdaRESUMO
OBJECTIVES: Artificial intelligence (AI) has tremendous potential to help radiologists in daily clinical routine. However, a seamless, standardized, and time-efficient way of integrating AI into the radiology workflow is often lacking. This constrains the full potential of this technology. To address this, we developed a new reporting pipeline that enables automated pre-population of structured reports with results provided by AI tools. METHODS: Findings from a commercially available AI tool for chest X-ray pathology detection were sent to an IHE-MRRT-compliant structured reporting (SR) platform as DICOM SR elements and used to automatically pre-populate a chest X-ray SR template. Pre-populated AI results could be validated, altered, or deleted by radiologists accessing the SR template. We assessed the performance of this newly developed AI to SR pipeline by comparing reporting times and subjective report quality to reports created as free-text and conventional structured reports. RESULTS: Chest X-ray reports with the new pipeline could be created in significantly less time than free-text reports and conventional structured reports (mean reporting times: 66.8 s vs. 85.6 s and 85.8 s, respectively; both p < 0.001). Reports created with the pipeline were rated significantly higher quality on a 5-point Likert scale than free-text reports (p < 0.001). CONCLUSION: The AI to SR pipeline offers a standardized, time-efficient way to integrate AI-generated findings into the reporting workflow as parts of structured reports and has the potential to improve clinical AI integration and further increase synergy between AI and SR in the future. CRITICAL RELEVANCE STATEMENT: With the AI-to-structured reporting pipeline, chest X-ray reports can be created in a standardized, time-efficient, and high-quality manner. The pipeline has the potential to improve AI integration into daily clinical routine, which may facilitate utilization of the benefits of AI to the fullest. KEY POINTS: ⢠A pipeline was developed for automated transfer of AI results into structured reports. ⢠Pipeline chest X-ray reporting is faster than free-text or conventional structured reports. ⢠Report quality was also rated higher for reports created with the pipeline. ⢠The pipeline offers efficient, standardized AI integration into the clinical workflow.
RESUMO
Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.
Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Constrição Patológica , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia CoronáriaRESUMO
BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.
Assuntos
Estenose Coronária , Placa Aterosclerótica , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Estudos Retrospectivos , Constrição Patológica , Tomografia Computadorizada por Raios X/métodos , Estenose Coronária/diagnóstico por imagemRESUMO
BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.
Assuntos
Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Humanos , Feminino , Masculino , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Ventrículos do Coração , Função Ventricular EsquerdaRESUMO
Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.
RESUMO
OBJECTIVES: Medical imaging plays an essential role in healthcare. As a diagnostic test, imaging is prone to substantial overuse and potential overdiagnosis, with dire consequences to patient outcomes and health care costs. Clinical decision support systems (CDSSs) were developed to guide referring physicians in making appropriate imaging decisions. This study will evaluate the effect of implementing a CDSS (ESR iGuide) with versus without active decision support in a physician order entry on the appropriate use of imaging tests and ordering behaviour. METHODS: A protocol for a multi-center cluster-randomized trial with departments acting as clusters, combined with a before-after-revert design. Four university hospitals with eight participating departments each for a total of thirty-two clusters will be included in the study. All departments start in control condition with structured data entry of the clinical indication and tracking of the imaging exams requested. Initially, the CDSS is implemented and all physicians remain blinded to appropriateness scores based on the ESR imaging referral guidelines. After randomization, half of the clusters switch to the active intervention of decision support. Physicians in the active condition are made aware of the categorization of their requests as appropriate, under certain conditions appropriate, or inappropriate, and appropriate exams are suggested. Physicians may change their requests in response to feedback. In the revert condition, active decision support is removed to study the educational effect. RESULTS/CONCLUSIONS: The main outcome is the proportion of inappropriate diagnostic imaging exams requested per cluster. Secondary outcomes are the absolute number of imaging exams, radiation from diagnostic imaging, and medical costs. TRIAL REGISTRATION NUMBER: Approval from the Medical Ethics Review Committee was obtained under protocol numbers 20-069 (Augsburg), B 238/21 (Kiel), 20-318 (Lübeck) and 2020-15,125 (Mainz). The trial is registered in the ClinicalTrials.gov register under registration number NCT05490290.
Assuntos
Sistemas de Apoio a Decisões Clínicas , Humanos , Diagnóstico por Imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como AssuntoRESUMO
PURPOSE: Kidney volume is important in the management of renal diseases. Unfortunately, the currently available, semi-automated kidney volume determination is time-consuming and prone to errors. Recent advances in its automation are promising but mostly require contrast-enhanced computed tomography (CT) scans. This study aimed at establishing an automated estimation of kidney volume in non-contrast, low-dose CT scans of patients with suspected urolithiasis. METHODS: The kidney segmentation process was automated with 2D Convolutional Neural Network (CNN) models trained on manually segmented 2D transverse images extracted from low-dose, unenhanced CT scans of 210 patients. The models' segmentation accuracy was assessed using Dice Similarity Coefficient (DSC), for the overlap with manually-generated masks on a set of images not used in the training. Next, the models were applied to 22 previously unseen cases to segment kidney regions. The volume of each kidney was calculated from the product of voxel number and their volume in each segmented mask. Kidney volume results were then validated against results semi-automatically obtained by radiologists. RESULTS: The CNN-enabled kidney volume estimation took a mean of 32 s for both kidneys in a CT scan with an average of 1026 slices. The DSC was 0.91 and 0.86 and for left and right kidneys, respectively. Inter-rater variability had consistencies of ICC = 0.89 (right), 0.92 (left), and absolute agreements of ICC = 0.89 (right), 0.93 (left) between the CNN-enabled and semi-automated volume estimations. CONCLUSION: In our work, we demonstrated that CNN-enabled kidney volume estimation is feasible and highly reproducible in low-dose, non-enhanced CT scans. Automatic segmentation can thereby quantitatively enhance radiological reports.
Assuntos
Redes Neurais de Computação , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Cintilografia , Rim/diagnóstico por imagem , Automação , Processamento de Imagem Assistida por Computador/métodosRESUMO
BACKGROUND: Photon-counting detector computed tomography (PCD-CT) may influence imaging characteristics for various clinical conditions due to higher signal and contrast-to-noise ratio in virtual monoenergetic images (VMI). Radiomics analysis relies on quantification of image characteristics. We evaluated the impact of different VMI reconstructions on radiomic features in in vitro and in vivo PCD-CT datasets. METHODS: An organic phantom consisting of twelve samples (four oranges, four onions, and four apples) was scanned five times. Twenty-three patients who had undergone coronary computed tomography angiography on a first generation PCD-CT system with the same image acquisitions were analyzed. VMIs were reconstructed at 6 keV levels (40, 55, 70, 90, 120, and 190 keV). The phantoms and the patients' left ventricular myocardium (LVM) were segmented for all reconstructions. Ninety-three original radiomic features were extracted. Repeatability and reproducibility were evaluated through intraclass correlations coefficient (ICC) and post hoc paired samples ANOVA t test. RESULTS: There was excellent repeatability for radiomic features in phantom scans (all ICC = 1.00). Among all VMIs, 36/93 radiomic features (38.7%) in apples, 28/93 (30.1%) in oranges, and 33/93 (35.5%) in onions were not significantly different. For LVM, the percentage of stable features was high between VMIs ≥ 90 keV (90 versus 120 keV, 77.4%; 90 versus 190 keV, 83.9%; 120 versus 190 keV, 89.3%), while comparison to lower VMI levels led to fewer reproducible features (40 versus 55 keV, 8.6%). CONCLUSIONS: VMI levels influence the stability of radiomic features in an organic phantom and patients' LVM; stability decreases considerably below 90 keV. RELEVANCE STATEMENT: Spectral reconstructions significantly influence radiomic features in vitro and in vivo, necessitating standardization and careful attention to these reconstruction parameters before clinical implementation. KEY POINTS: ⢠Radiomic features have an excellent repeatability within the same PCD-CT acquisition and reconstruction. ⢠Differences in VMI lead to decreased reproducibility for radiomic features. ⢠VMI ≥ 90 keV increased the reproducibility of the radiomic features.
Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , MiocárdioRESUMO
Persistent or recurrent cardiovascular symptoms have been identified as one of the hallmarks of long-COVID or post-acute sequelae of SARS-CoV-2 infection (PASC). The purpose of this study was to determine the prevalence and extent of cardiac abnormalities in patients referred for cardiac MRI due to clinical evidence of PASC. To investigate this, two tertiary care hospitals identified all patients who were referred for cardiac MRI under the suspicion of PASC in a 2-year period and retrospectively included them in this study. Patients with previously known cardiac diseases were excluded. This resulted in a total cohort of 129 patients (63, 51% female; age 41 ± 16 years). The majority of patients (57%) showed normal cardiac results. No patient had active myocarditis or an acute myocardial infarction. However, 30% of patients had evidence of non-ischemic myocardial fibrosis, which exceeds the prevalence in the normal adult population and suggests that a possible history of myocarditis might explain persistent symptoms in the PASC setting.