Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(16)2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39204836

RESUMO

Micro-Computed Tomography (µCT) systems are used for examining the internal structures of various objects, such as material samples, manufactured parts, and natural objects. Resolving fine details or performing accurate geometric measurements in the voxel data critically depends on the precise calibration of the µCT systems geometry. This paper presents a calibration method for µCT systems using projections of a calibration phantom, where the coordinates of the phantom are initially unknown. The approach involves detecting and tracking steel ball bearings and adjusting the unknown system geometry parameters using non-linear least squares optimization. Multiple geometric models are tested to verify their suitability for a self-calibration approach. The implementation is tested using a calibration phantom captured at different magnifications. The results demonstrate the system's capability to determine the geometry model parameters with a remaining error on the detector between 0.27 px and 0.18 px. Systematic errors that remain after calibration, as well as changing parameters due to system instabilities, are investigated. The source code of this work is published to enable further research.

2.
Bioprocess Biosyst Eng ; 41(3): 369-380, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29230535

RESUMO

A novel, non-destructive method for the biomass estimation of biological samples on culture dishes was developed. To achieve this, a photogrammetric system, which consists of a digital single-lens reflex camera (DSLR), an illuminated platform where the culture dishes are positioned and an Arduino board which controls the capturing process, was constructed. The camera was mounted on a holder which set the camera at different title angles and the platform rotated, to capture images from different directions. A software, based on stereo photogrammetry, was developed for the three-dimensional (3D) reconstruction of the samples. The proof-of-concept was demonstrated in a series of experiments with plant tissue cultures and specifically with calli cultures of Salvia fruticosa and Ocimum basilicum. For a period of 14 days images of these cultures were acquired and 3D-reconstructions and volumetric data were obtained. The volumetric data correlated well with the experimental measurements and made the calculation of the specific growth rate, µ max, possible. The µ max value for S. fruticosa samples was 0.14 day-1 and for O. basilicum 0.16 day-1. The developed method demonstrated the high potential of this photogrammetric approach in the biological sciences.


Assuntos
Biomassa , Ocimum basilicum/citologia , Fotogrametria/métodos , Células Vegetais , Salvia/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...