Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Gerontol Geriatr Med ; 10: 23337214241246843, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628166

RESUMO

Background: Perturbation-based balance training (PBT) is a promising fall risk reduction method that involves inducing unexpected perturbations to balance to train participants reactive balance control. Due to the unpredictable nature of PBT, its acceptability to older adults could present a barrier to the implementation of PBT in the community. Aim/Purpose: The purpose of this study was to assess the perceived acceptability of a community-based PBT program to both older adults and healthcare professionals (HCPs). Methods: Nineteen older adults (aged 69.6 ± 6.6 years, 17 women, 2 men) and three HCPs participated in the qualitative study. Participants completed four PBT sessions facilitated in conjunction with HCPs. Interviews, based on the theoretical framework of acceptability, were conducted before and after PBT and analyzed using template analysis. Results: PBT was perceived as effective by older adults and HCPs. However, HCPs perceived the equipment cost as a substantial barrier to feasibility in the community.

2.
J Biomed Opt ; 28(10): 102910, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37799938

RESUMO

Significance: Optical coherence tomography (OCT) can be integrated into needle probes to provide real-time navigational guidance. However, unscanned implementations, which are the simplest to build, often struggle to discriminate the relevant tissues. Aim: We explore the use of polarization-sensitive (PS) methods as a means to enhance signal interpretability within unscanned coherence tomography probes. Approach: Broadband light from a laser centered at 1310 nm was sent through a fiber that was embedded into a needle. The polarization signal from OCT fringes was combined with Doppler-based tracking to create visualizations of the birefringence properties of the tissue. Experiments were performed in (i) well-understood structured tissues (salmon and shrimp) and (ii) ex vivo porcine spine. The porcine experiments were selected to illustrate an epidural guidance use case. Results: In the porcine spine, unscanned and Doppler-tracked PS OCT imaging data successfully identified the skin, subcutaneous tissue, ligament, and epidural spaces during needle insertion. Conclusions: PS imaging within a needle probe improves signal interpretability relative to structural OCT methods and may advance the clinical utility of unscanned OCT needle probes in a variety of applications.


Assuntos
Pele , Tomografia de Coerência Óptica , Animais , Suínos , Tomografia de Coerência Óptica/métodos , Pele/diagnóstico por imagem , Luz , Refração Ocular , Birrefringência
3.
ArXiv ; 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37292463

RESUMO

We demonstrate that a simple, unscanned polarization-sensitive optical coherence tomography needle probe can be used to perform layer identification in biological tissues. Broadband light from a laser centered at 1310 nm was sent through a fiber that was embedded into a needle, and analysis of the polarization state of the returning light after interference coupled with Doppler-based tracking allowed the calculation of phase retardation and optic axis orientation at each needle location. Proof-of-concept phase retardation mapping was shown in Atlantic salmon tissue, while axis orientation mapping was demonstrated in white shrimp tissue. The needle probe was then tested on the ex vivo porcine spine, where mock epidural procedures were performed. Our imaging results demonstrate that unscanned, Doppler-tracked polarization-sensitive optical coherence tomography imaging successfully identified the skin, subcutaneous tissue, and ligament layers, before successfully reaching the target of the epidural space. The addition of polarization-sensitive imaging into the bore of a needle probe therefore allows layer identification at deeper locations in the tissue.

4.
Transl Vis Sci Technol ; 11(10): 28, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36259678

RESUMO

Purpose: Melanin plays an important function in maintaining eye health, however there are few metrics that can be used to study retinal melanin content in vivo. Methods: The slope of the spectral coefficient of variation (SSCoV) is a novel biomarker that measures chromophore concentration by analyzing the local divergence of spectral intensities using optical coherence tomography (OCT). This metric was validated in a phantom and applied in a longitudinal study of superoxide dismutase 1 knockout (SOD1-/-) mice, a model for wet and dry age-related macular degeneration. We also examined a new feature of interest in standard OCT image data, the ratio of maximum intensity in the retinal pigment epithelium to that of the choroid (RC ratio). These new biomarkers were supported by polarization-sensitive OCT and histological analysis. Results: SSCoV correlated well with depolarization metrics both in phantom and in vivo with both metrics decreasing more rapidly in SOD1-/- mice with age (P < 0.05). This finding is correlated with reduced melanin pigmentation in the choroid over time. The RC ratio clearly differentiated the SOD1-/- and control groups (P < 0.0005) irrespective of time and may indicate lower retinal pigment epithelium melanin in the SOD1-/- mice. Histological analysis showed decreased melanin content and potential differences in melanin granule shape in SOD1-/- mice. Conclusions: SSCoV and RC ratio biomarkers provided insights into the changes of retinal melanin in the SOD1-/- model longitudinally and noninvasively. Translational Relevance: These biomarkers were designed with the potential for rapid adoption by existing clinical OCT systems without requiring new hardware.


Assuntos
Melaninas , Tomografia de Coerência Óptica , Camundongos , Animais , Tomografia de Coerência Óptica/métodos , Superóxido Dismutase-1 , Estudos Longitudinais , Biomarcadores
5.
Opt Lett ; 47(6): 1517-1520, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35290353

RESUMO

In optical coherence tomography (OCT), axial resolution and signal-to-noise ratio (SNR) are typically viewed as uncoupled parameters. We show that this is true only for mirror-like surfaces and that in diffuse scattering samples such as biological tissues there is an inherent coupling between axial resolution and measurement SNR. We explain the origin of this coupling and demonstrate that it can be used to achieve increased imaging penetration depth at the expense of resolution. Finally, we argue that this coupling should be considered during OCT system design processes that seek to balance the competing needs of resolution, sensitivity, and system/source complexity.


Assuntos
Tomografia de Coerência Óptica , Razão Sinal-Ruído , Tomografia de Coerência Óptica/métodos
6.
Expert Opin Ther Targets ; 26(3): 217-231, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35225722

RESUMO

INTRODUCTION: Calpain-1 and calpain-2 are prototypical classical isoforms of the calpain family of calcium-activated cysteine proteases. Their substrate proteins participate in a wide range of cellular processes, including transcription, survival, proliferation, apoptosis, migration, and invasion. Dysregulated calpain activity has been implicated in tumorigenesis, suggesting that calpains may be promising therapeutic targets. AREAS COVERED: This review covers clinical and basic research studies implicating calpain-1 and calpain-2 expression and activity in tumorigenesis and metastasis. We highlight isoform specific functions and provide an overview of substrates and cancer-related signalling pathways affected by calpain-mediated proteolytic cleavage. We also discuss efforts to develop clinically relevant calpain specific inhibitors and spotlight the challenges facing inhibitor development. EXPERT OPINION: Rationale for targeting calpain-1 and calpain-2 in cancer is supported by pre-clinical and clinical studies demonstrating that calpain inhibition has the potential to attenuate carcinogenesis and block metastasis of aggressive tumors. The wide range of substrates and cleavage products, paired with inconsistencies in model systems, underscores the need for more complete understanding of physiological substrates and how calpain cleavage alters their functions in cellular processes. The development of isoform specific calpain inhibitors remains an important goal with therapeutic potential in cancer and other diseases.


Assuntos
Calpaína , Neoplasias , Apoptose , Calpaína/metabolismo , Carcinogênese , Humanos , Neoplasias/tratamento farmacológico , Isoformas de Proteínas
7.
Biomed Opt Express ; 12(4): 1774-1791, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33996197

RESUMO

Vascular leakage plays a key role in vision-threatening retinal diseases such as diabetic retinopathy and age-related macular degeneration. Fluorescence angiography is the current gold standard for identification of leaky vasculature in vivo, however it lacks depth resolution, providing only 2D images that complicate precise identification and localization of pathological vessels. Optical coherence tomography (OCT) has been widely adopted for clinical ophthalmology due to its high, micron-scale resolution and rapid volumetric scanning capabilities. Nevertheless, OCT cannot currently identify leaky blood vessels. To address this need, we have developed a new method called exogenous contrast-enhanced leakage OCT (ExCEL-OCT) which identifies the diffusion of tracer particles around leaky vasculature following injection of a contrast agent. We apply this method to a mouse model of retinal neovascularization and demonstrate high-resolution 3D vascular leakage measurements in vivo for the first time.

8.
Light Sci Appl ; 10(1): 6, 2021 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-33402664

RESUMO

In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.

9.
J Biophotonics ; 14(4): e202000323, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33332741

RESUMO

Polarization-sensitive optical coherence tomography (PS-OCT) enables three-dimensional imaging of biological tissues based on the inherent contrast provided by scattering and polarization properties. In fibrous tissue such as the white matter of the brain, PS-OCT allows quantitative mapping of tissue birefringence. For the popular PS-OCT layout using a single circular input state, birefringence measurements are based on a straight-forward evaluation of phase retardation data. However, the accuracy of these measurements strongly depends on the signal-to-noise ratio (SNR) and is prone to mapping artifacts when the SNR is low. Here we present a simple yet effective approach for improving the accuracy of PS-OCT phase retardation and birefringence measurements. By performing a noise bias correction of the detected OCT signal amplitudes, the impact of the noise floor on retardation measurements can be markedly reduced. We present simulation data to illustrate the influence of the noise bias correction on phase retardation measurements and support our analysis with real-world PS-OCT image data.


Assuntos
Artefatos , Tomografia de Coerência Óptica , Birrefringência , Neuroimagem , Razão Sinal-Ruído
10.
Transl Vis Sci Technol ; 9(4): 15, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32818102

RESUMO

Purpose: The retinal phenotype of popular mouse models mimicking ophthalmic diseases, such as the superoxide dismutase 1 (SOD1) knockout (KO) mouse model, has mainly been assessed by ex vivo histology and in vivo fundus photography. We used multifunctional optical coherence tomography (OCT) to characterize the retinas of SOD1 KO mice in vivo. Methods: The custom-made ophthalmoscope featured a combination of conventional OCT, polarization-sensitive OCT, and OCT angiography. Seven SOD1 KO mice and nine age-matched controls were imaged between 6 and 17 months of age. A postprocessing framework was used to analyze total and outer retinal thickness changes. Drusenlike lesions were segmented, and their sizes and the number of lesions were assessed quantitatively. Their appearance in the conventional reflectivity images, as well as in the corresponding polarization-sensitive images, was characterized qualitatively. Results: Drusenlike lesions increased in size and number with age for SOD1 KO mice. Exploiting the multiple contrast channels, the appearance of the lesions was found to resemble pseudodrusen observed in eyes of patients suffering from dry age-related macular degeneration. The total and outer retinal thicknesses were lower on average after 11 months and 7 months in SOD1 KO mice compared with age-matched controls. Neovascularizations were found in one out of seven KO animals. Conclusions: OCT imaging proved beneficial for a detailed in vivo characterization of the pathological changes in SOD1 KO mice. Translational Relevance: Phenotyping of animal models using modern imaging concepts can be conducted with more precision and might also ease the translation of conclusions between clinical and preclinical research.


Assuntos
Superóxido Dismutase , Tomografia de Coerência Óptica , Animais , Humanos , Camundongos , Camundongos Knockout , Retina/diagnóstico por imagem , Superóxido Dismutase/genética , Superóxido Dismutase-1/genética
11.
Cancers (Basel) ; 12(7)2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-32640583

RESUMO

Fluorescence-guided surgery is a state-of-the-art approach for intraoperative imaging during neurosurgical removal of tumor tissue. While the visualization of high-grade gliomas is reliable, lower grade glioma often lack visible fluorescence signals. Here, we present a hybrid prototype combining visible light optical coherence microscopy (OCM) and high-resolution fluorescence imaging for assessment of brain tumor samples acquired by 5-aminolevulinic acid (5-ALA) fluorescence-guided surgery. OCM provides high-resolution information of the inherent tissue scattering and absorption properties of tissue. We here explore quantitative attenuation coefficients derived from volumetric OCM intensity data and quantitative high-resolution 5-ALA fluorescence as potential biomarkers for tissue malignancy including otherwise difficult-to-assess low-grade glioma. We validate our findings against the gold standard histology and use attenuation and fluorescence intensity measures to differentiate between tumor core, infiltrative zone and adjacent brain tissue. Using large field-of-view scans acquired by a near-infrared swept-source optical coherence tomography setup, we provide initial assessments of tumor heterogeneity. Finally, we use cross-sectional OCM images to train a convolutional neural network that discriminates tumor from non-tumor tissue with an accuracy of 97%. Collectively, the present hybrid approach offers potential to translate into an in vivo imaging setup for substantially improved intraoperative guidance of brain tumor surgeries.

12.
Opt Lett ; 45(8): 2359-2362, 2020 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-32287239

RESUMO

In recent years, there has been growing interest in the application of exogenous contrast agents to supplement the traditional strengths of optical coherence tomography (OCT) and provide additional biological information. In this Letter, we present how indocyanine green, a common fluorescent contrast agent approved by the United States Food and Drug Administration, can provide absorption and spectral contrast for OCT imaging in the mouse eye in vivo. We further demonstrate high stability of spectral contrast measurements for the long-term monitoring of contrast agents in spite of fluctuations in intensity.


Assuntos
Absorção Fisico-Química , Corantes Fluorescentes/química , Verde de Indocianina/química , Tomografia de Coerência Óptica/métodos , Animais , Camundongos , Retina/diagnóstico por imagem , Razão Sinal-Ruído
13.
Biomed Opt Express ; 11(4): 2085-2097, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32341868

RESUMO

Diagnostic classification techniques used to diagnose cataracts, the world's leading cause of blindness, are currently based on subjective methods. Here, we present optical coherence tomography as a noninvasive tool for volumetric visualization of lesions formed in the crystalline lens. A custom-made swept-source optical coherence tomography (SS-OCT) system was utilized to investigate the murine crystalline lens. In addition to imaging cataractous lesions in aged wildtype mice, we studied the structure and shape of cataracts in a mouse model of Alzheimer's disease. Hyperscattering opacifications in the crystalline lens were observed in both groups. Post mortem histological analysis were performed to correlate findings in the anterior and posterior part of the lens to 3D OCT in vivo imaging. Our results showcase the capability of OCT to rapidly visualize cataractous lesions in the murine lens and suggest that OCT might be a valuable tool that provides additional insight for preclinical studies of cataract formation.

14.
Neurophotonics ; 7(1): 015006, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32042855

RESUMO

Significance. Recent Alzheimer's disease (AD) patient studies have focused on retinal analysis, as the retina is the only part of the central nervous system that can be imaged noninvasively by optical methods. However, as this is a relatively new approach, the occurrence and role of retinal pathological features are still debated. Aim. The retina of an APP/PS1 mouse model was investigated using multicontrast optical coherence tomography (OCT) in order to provide a documentation of what was observed in both transgenic and wild-type mice. Approach. Both eyes of 24 APP/PS1 transgenic mice (age: 45 to 104 weeks) and 15 age-matched wild-type littermates were imaged by the custom-built OCT system. At the end of the experiment, retinas and brains were harvested from a subset of the mice (14 transgenic, 7 age-matched control) in order to compare the in vivo results to histological analysis and to quantify the cortical amyloid beta plaque load. Results. The system provided a combination of standard reflectivity data, polarization-sensitive data, and OCT angiograms. Qualitative and quantitative information from the resultant OCT images was extracted on retinal layer thickness and structure, presence of hyper-reflective foci, phase retardation abnormalities, and retinal vasculature. Conclusions. Although multicontrast OCT revealed abnormal structural properties and phase retardation signals in the retina of this APP/PS1 mouse model, the observations were very similar in transgenic and control mice.

15.
Opt Lett ; 44(16): 4040-4043, 2019 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-31415542

RESUMO

We present a polarization-sensitive (PS) extension for bright- and dark-field (BRAD) optical coherence tomography imaging. Using a few-mode fiber detection scheme, the light backscattered at different angles is separated, and the BRAD images of tissue scattering are generated. A calibration method to correct for the fiber birefringence is proposed. Since particle scattering profiles are polarization dependent, a PS detection extends the capabilities for investigating the scattering properties of biological tissues. Both phantoms consisting of different-sized microparticles and a brain tissue specimen were imaged to validate the system performance and demonstrate the complementary image contrast.

16.
J Biophotonics ; 12(12): e201900153, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31334610

RESUMO

Previous studies for melanin visualization in the retinal pigment epithelium (RPE) have exploited either its absorption properties (using photoacoustic tomography or photothermal optical coherence tomography [OCT]) or its depolarization properties (using polarization sensitive OCT). However, these methods are only suitable when the melanin concentration is sufficiently high. In this work, we present the concept of hyperspectral OCT for melanin visualization in the RPE when the concentration is low. Based on white light OCT, a hyperspectral stack of 27 wavelengths (440-700 nm) was created in post-processing for each depth-resolved image. Owing to the size and shape of the melanin granules in the RPE, the variations in backscattering coefficient as a function of wavelength could be identified-a result which is to be expected from Mie theory. This effect was successfully identified both in eumelanin-containing phantoms and in vivo in the low-concentration Brown Norway rat RPE.


Assuntos
Melaninas/metabolismo , Descolamento Retiniano/metabolismo , Tomografia de Coerência Óptica , Animais , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Camundongos , Imagens de Fantasmas , Ratos
17.
J Biomed Opt ; 24(6): 1-11, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31240898

RESUMO

We present a multimodal visible light optical coherence microscopy (OCM) and fluorescence imaging (FI) setup. Specification and phantom measurements were performed to characterize the system. Two applications in neuroimaging were investigated. First, curcumin-stained brain slices of a mouse model of Alzheimer's disease were examined. Amyloid-beta plaques were identified based on the fluorescence of curcumin, and coregistered morphological images of the brain tissue were provided by the OCM channel. Second, human brain tumor biopsies retrieved intraoperatively were imaged prior to conventional neuropathologic work-up. OCM revealed the three-dimensional structure of the brain parenchyma, and FI added the tumor tissue-specific contrast. Attenuation coefficients computed from the OCM data and the florescence intensity values were analyzed and showed a statistically significant difference for 5-aminolevulinic acid (5-ALA)-positive and -negative brain tissues. OCM findings correlated well with malignant hot spots within brain tumor biopsies upon histopathology. The combination of OCM and FI seems to be a promising optical imaging modality providing complementary contrast for applications in the field of neuroimaging.


Assuntos
Doença de Alzheimer/diagnóstico , Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Microscopia/métodos , Neuroimagem/métodos , Imagem Óptica/métodos , Tomografia de Coerência Óptica/métodos , Doença de Alzheimer/patologia , Animais , Encéfalo/patologia , Neoplasias Encefálicas/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Placa Amiloide/diagnóstico por imagem
18.
J Biomed Opt ; 23(8): 1-12, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30168301

RESUMO

Polarization-sensitive optical coherence tomography (PS-OCT) enables noninvasive, high-resolution imaging of tissue polarization properties. In the anterior segments of human eyes, PS-OCT allows the visualization of birefringent and depolarizing structures. We present the use of PS-OCT for imaging the murine anterior eye. Using a spectral domain PS-OCT setup operating in the 840-nm regime, we performed in vivo volumetric imaging in anesthetized C57BL/6 mice. The polarization properties of murine anterior eye structures largely replicated those known from human PS-OCT imagery, suggesting that the mouse eye may also serve as a model system under polarization contrast. However, dissimilarities were found in the depolarizing structure of the iris which, as we confirmed in postmortem histological sections, were caused by anatomical differences between both species. In addition to the imaging of tissues in the anterior chamber and the iridocorneal angle, we demonstrate longitudinal PS-OCT imaging of the murine anterior segment during mydriasis as well as birefringence imaging of corneal pathology in an aged mouse.


Assuntos
Córnea/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Animais , Birrefringência , Catarata/diagnóstico por imagem , Catarata/patologia , Córnea/patologia , Técnicas de Diagnóstico Oftalmológico , Desenho de Equipamento , Camundongos , Camundongos Endogâmicos C57BL , Midríase/diagnóstico por imagem , Processamento de Sinais Assistido por Computador
19.
Biomed Opt Express ; 9(6): 2476-2494, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30258667

RESUMO

Optical coherence tomography (OCT) is a powerful technology for rapid volumetric imaging in biomedicine. The bright field imaging approach of conventional OCT systems is based on the detection of directly backscattered light, thereby waiving the wealth of information contained in the angular scattering distribution. Here we demonstrate that the unique features of few-mode fibers (FMF) enable simultaneous bright and dark field (BRAD) imaging for OCT. As backscattered light is picked up by the different modes of a FMF depending upon the angular scattering pattern, we obtain access to the directional scattering signatures of different tissues by decoupling illumination and detection paths. We exploit the distinct modal propagation properties of the FMF in concert with the long coherence lengths provided by modern wavelength-swept lasers to achieve multiplexing of the different modal responses into a combined OCT tomogram. We demonstrate BRAD sensing for distinguishing differently sized microparticles and showcase the performance of BRAD-OCT imaging with enhanced contrast for ex vivo tumorous tissue in glioblastoma and neuritic plaques in Alzheimer's disease.

20.
Neurophotonics ; 5(3): 035002, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30137880

RESUMO

We implemented a wide field-of-view visible-light optical coherence microscope (OCM) for investigating ex-vivo brain tissue of patients diagnosed with Alzheimer's disease (AD) and of a mouse model of AD. A submicrometer axial resolution in tissue was achieved using a broad visible light spectrum. The use of various objective lenses enabled reaching micrometer transversal resolution and the acquisition of images of microscopic brain features, such as cell structures, vessels, and white matter tracts. Amyloid-beta plaques in the range of 10 to 70 µm were visualized. Large field-of-view images of young and old mouse brain sections were imaged using an automated x-y-z stage. The plaque load was characterized, revealing an age-related increase. Human brain tissue affected by cerebral amyloid angiopathy was investigated and hyperscattering structures resembling amyloid beta accumulations in the vessel walls were identified. All results were in good agreement with histology. A comparison of plaque features in both human and mouse brain tissue was performed, revealing an increase in plaque load and a decrease in reflectivity for mouse as compared with human brain tissue. Based on the promising outcome of our experiments, visible light OCM might be a powerful tool for investigating microscopic features in ex-vivo brain tissue.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...