RESUMO
Objective: To examine the application effect of ultrasound-guided placement of midline catheter and to select the appropriate placement method of intravenous catheter for patients with oral and maxillofacial tumors. Methods: We retrospectively analyzed the general data and venous catheter-related information of 143 oral and maxillofacial tumor patients who received treatment between June 2019 and December 2021. There were two patient groups, a control group of patients with inserted peripheral venous catheters (PVC) and an observation group of patients with midline catheters placed under ultrasound guidance. We made a comparative analysis of the incidence of catheter-related complications, including bleeding at the insertion site, phlebitis, catheter blockage, extravasation, etc., in the two groups. When the baseline data from the two groups were not balanced, we used propensity score matching (PSM) to match the general data before comparing the complication incidence between the two groups. Results: There were 71 patients who underwent 215 times of PVC placement in the control group and 72 patients who underwent 72 times of midline catheter placement in the observation group. There was no significant difference between the patients in the two groups in terms of age, sex, diagnosis, or the use of anticoagulant medication ( P>0.05) . The observation group had longer average length-of-stay than the control group did ( P<0.01). The cost of catheter placement in the observation group was 1080 yuan per set, with the average daily cost being about (56.27±20.23) yuan. Patients in the control group had PVC placement for an average of (3.03±0.93) times. The cost for PVC placement was 96 yuan per time and the average daily cost was about (19.94±7.50) yuan. There was significant difference in the average daily cost between the observation group and the control group ( P<0.01). PSM was performed for the two groups. Before PSM, the incidence of catheter-related complications in the observation group (8.3%, 6/72) was lower than that of the control group (30.2%, 65/215) and the difference was statistically significant ( P<0.01). After PSM, 72 times of catheter placement from each group were included in comparative analysis. The incidence of catheter-related complications in the observation group (8.3%, 6/72) was lower than that of the control group (54.2%, 39/72) and the difference was statistically significant ( P<0.01). Conclusion: Patients have low incidence of catheter-related complications when they have midline catheter placed under ultrasound guidance, which helps reduce the pain of repeated venous insertion that patients incur and the workload of clinical nurses. The use of midline catheters is appropriate for and should be popularized among patients with oral and maxillofacial malignant tumors, especially patients who have poor peripheral venous conditions and those who are undergoing repair and reconstruction surgeries.
Assuntos
Cateterismo Venoso Central , Cateterismo Periférico , Neoplasias , Humanos , Estudos Retrospectivos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Catéteres , Ultrassonografia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodosRESUMO
BACKGROUND: Mandibular osteoradionecrosis (ORN) is a devastating complication secondary to the radiotherapy of head and neck cancer. The nutritional status of ORN patients is compromised, but remains rarely studied. We aimed to evaluate the overall nutritional status of patients with ORN and explore the risk factors behind poor nutrition. METHODS: This is a single-institution cross-sectional study. Patients diagnosed with ORN were consecutively recruited in a tertiary teaching hospital from July 2017 to August 2019. Multiple laboratory markers and physical indicators were examined to profile their nutritional status. The potential risk factors of poor nutrition were explored by logistic regression. RESULTS: A total of 107 patients with ORN were recruited. Among them, almost all patients (95.3%) had at least one laboratory marker lower than the normal physiological range. A total of 40 (37.5%) patients were categorized as undernutrition, who had lower serum albumin (mean difference: 1.8 ± 0.8 g/L; p = .02), prealbumin (mean difference: 26.8 ± 10.8 mg/L; p = .02), and BMI (3.8 ± 0.4 kg/m2 ; p < .0001) compared to patients of normal nutrition. Notably, the multivariate logistic regression indicated that patients with semi-liquid diet had 14.41 (95% CI: 3.03-68.54, p = .001) times; patients with liquid diet had 5.70 (95% CI: 1.55-20.98, p = .009) times more likely to be in undernutrition, as compared to patients with regular diets. CONCLUSIONS: This is the first study characterizing the poor nutritional status in ORN patients. Patients having semi-liquid or liquid diets tended to have poorer nutritional status. The nutritional status of ORN patients should be underlined for professional nutritional supports so as to enhance their quality of life. More studies are warranted.
Assuntos
Neoplasias de Cabeça e Pescoço , Doenças Mandibulares , Osteorradionecrose , Estudos Transversais , Neoplasias de Cabeça e Pescoço/complicações , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Mandíbula , Doenças Mandibulares/complicações , Estado Nutricional , Osteorradionecrose/etiologia , Qualidade de Vida , Estudos RetrospectivosRESUMO
AIM: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes. BACKGROUND: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities; therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. METHODS: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. RESULTS: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3% (17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P > 0.05). CONCLUSION: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method.