Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros













Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38718698

RESUMO

Aerosol microparticles in exhaled breath carry non-volatile compounds from the deeper parts of the lung. When captured and analyzed, these aerosol microparticles constitute a non-invasive and readily available specimen for drugs of abuse testing. The present study aimed to evaluate a simple breath collection device in a clinical setting. The device divides a breath sample into three parallel "collectors" that can be individually analyzed. Urine was used as the reference specimen, and parallel specimens were collected from 99 patients undergoing methadone maintenance treatment. Methadone was used as the primary validation parameter. A sensitive multi-analyte method using tandem liquid chromatography - mass spectrometry was developed and validated as part of the project. The method was successfully validated for 36 analytes with a limit of detection of 1 pg/collector for most compounds. Based on the validation results tetrahydrocannabinol THC), cannabidiol (CBD), and lysergic acid diethylamide (LSD) are suitable for qualitative analysis, but all other analytes can be quantitively assessed by the method. Methadone was positive in urine in 97 cases and detected in exhaled breath in 98 cases. Median methadone concentration was 64 pg/collector. The methadone metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) was detected in 90 % of the cases but below 10 pg/collector in most. Amphetamine was also present in the urine in 17 cases and in exhaled breath in 16 cases. Several other substances were detected in the exhaled breath and urine samples, but at a lower frequency. This study concluded that the device provides a specimen from exhaled breath, that is useful for drugs of abuse testing. The results show that high analytical sensitivity is needed to achieve good detectability and detection time after intake.


Assuntos
Testes Respiratórios , Limite de Detecção , Detecção do Abuso de Substâncias , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Detecção do Abuso de Substâncias/métodos , Testes Respiratórios/métodos , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Metadona/análise , Metadona/urina , Modelos Lineares , Masculino , Feminino , Adulto , Drogas Ilícitas/análise , Drogas Ilícitas/urina , Espectrometria de Massa com Cromatografia Líquida
2.
Drug Test Anal ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38663892

RESUMO

Phosphatidylethanol (PEth) measurement in whole blood samples is established as a specific alcohol biomarker with clinical and forensic applications. Establishment of dried blood spots (DBSs) as a specimen for PEth determination offers several advantages and was the focus of this work. A liquid chromatography tandem mass spectrometry method using a 96-well format for sample preparation was developed and validated. PEth was extracted from DBSs by using isopropanol containing PEth-d5 as internal standard. The blood sampling used a commercial volumetric DBS device having a phosholipase D inhibitor incorporated to stop continuous PEth formation. The method quantified PEth in the range of 0.05-10 µmol/L, with a bias and imprecision of less than 15%. In a clinical study (n = 25) using fingerprick blood, the volumetric device offered more precise quantifications (CV 4.6%) compared with the Whatman 903 Protein Saver card device (CV 16.6%). In another clinical study (n = 48), the use of dried venous and capillary blood, and liquid venous blood was compared under real-life conditions with samples sent by postal service. The capillary and venous DBS samples gave identical results while the liquid blood gave slightly higher values. Calculation of elimination half-life (PEth 16:0/18:1) in 31 cases based on two consecutive samples with 2-9 days in between gave results (mean 6.2 days) that agree with literature but several cases with values over 10 days. In conclusion, this study demonstrates that volumetric DBS is a valid specimen for determination of PEth blood concentrations, offering several advantages.

3.
Sci Rep ; 12(1): 20283, 2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36434044

RESUMO

The prevalence of drug use among nightlife attendees needs to be accurately estimated to, for example, evaluate preventive interventions. This study tested the feasibility of using a breath-sampling device to estimate the prevalence of drug use among nightlife attendees. The study was conducted at five nightclubs and a large music festival in Stockholm, Sweden. Participants were invited to participate and microparticles in exhaled breath were sampled and analyzed for 47 compounds using a state-of-the-art analytic method that follows forensic standards. In addition, participants' breath alcohol concentration was measured and they were interviewed about demographics, drinking habits, and drug use. Of the people invited, 73.7% (n = 1223) agreed to participate, and breath samples were collected from 1204 participants. Breath sampling was fast and well-accepted by participants. 13 percent of participants tested positive for an illicit drug, but only 4.3% self-reported drug use during the last 48 h. The most common substances detected were cocaine, amphetamine, and MDMA. There was no agreement between self-reported and measured use of any drug. Breath sampling is a convenient method to test illicit drug use among a large number of participants at events, and can be used as an estimate of drug use prevalence.


Assuntos
Líquidos Corporais , Drogas Ilícitas , Transtornos Relacionados ao Uso de Substâncias , Humanos , Prevalência , Estudos de Viabilidade , Transtornos Relacionados ao Uso de Substâncias/epidemiologia
4.
Anticancer Res ; 42(10): 5069-5076, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36191964

RESUMO

BACKGROUND/AIM: Solar ultraviolet radiation (UVR) is a carcinogen and irradiation of the skin results in DNA damage. Cyclobutane pyrimidine dimers (CPDs), including thymidine dimers, are among the most frequent forms of DNA damage. When CPDs are formed, the nucleotide excision repair system is activated and CPDs are excreted in the urine. Here, we developed a mass spectrometry-based method to quantify thymidine dimers in the urine and tested the method on a small group of volunteers after whole-body UVR exposure. PATIENTS AND METHODS: Years of research resulted in a method based on the "dilute-and-shoot" principle and ultra-performance liquid chromatography (UPLC) coupled to mass spectrometry. The whole body of each of eight healthy volunteers was exposed to 1.5-2.0 standard erythema doses (SEDs) of UVR for 3 consecutive days. Morning urine was collected on Day 1 (before irradiation) and on the following 7-9 days. Prior to analysis, sample preparation consisted of a simple dilution. A tandem quadrupole mass spectrometer coupled to UPLC was used for quantitative analysis in the multiple reaction monitoring mode. RESULTS: After 3 consecutive days of 1.5-2 SEDs, the highest level of thymidine dimer excretion occurred on Day 6 (0.7 ng/ml urine). Compared with baseline, significantly more thymidine dimers were excreted every day until Day 8 (p<0.016). Our method quantifies thymidine dimers that are excreted as dimers (i.e., not degraded further) after nucleotide excision repair. CONCLUSION: This is the first published mass spectrometry-based method for quantifying thymidine dimers in the urine after whole-body UVR exposure.


Assuntos
Dímeros de Pirimidina , Raios Ultravioleta , Carcinógenos , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Dano ao DNA , Reparo do DNA , Humanos , Dímeros de Pirimidina/efeitos da radiação , Dímeros de Pirimidina/urina , Espectrometria de Massas em Tandem , Timidina , Raios Ultravioleta/efeitos adversos , Voluntários
5.
Elife ; 102021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34747696

RESUMO

Reliable, robust, large-scale molecular testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for monitoring the ongoing coronavirus disease 2019 (COVID-19) pandemic. We have developed a scalable analytical approach to detect viral proteins based on peptide immuno-affinity enrichment combined with liquid chromatography-mass spectrometry (LC-MS). This is a multiplexed strategy, based on targeted proteomics analysis and read-out by LC-MS, capable of precisely quantifying and confirming the presence of SARS-CoV-2 in phosphate-buffered saline (PBS) swab media from combined throat/nasopharynx/saliva samples. The results reveal that the levels of SARS-CoV-2 measured by LC-MS correlate well with their correspondingreal-time polymerase chain reaction (RT-PCR) read-out (r = 0.79). The analytical workflow shows similar turnaround times as regular RT-PCR instrumentation with a quantitative read-out of viral proteins corresponding to cycle thresholds (Ct) equivalents ranging from 21 to 34. Using RT-PCR as a reference, we demonstrate that the LC-MS-based method has 100% negative percent agreement (estimated specificity) and 95% positive percent agreement (estimated sensitivity) when analyzing clinical samples collected from asymptomatic individuals with a Ct within the limit of detection of the mass spectrometer (Ct ≤ 30). These results suggest that a scalable analytical method based on LC-MS has a place in future pandemic preparedness centers to complement current virus detection technologies.


Assuntos
COVID-19/diagnóstico , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Técnicas de Diagnóstico Molecular/métodos , Proteínas Virais/análise , COVID-19/virologia , Humanos , Modelos Lineares , Nasofaringe/virologia , Fragmentos de Peptídeos/análise , Proteômica , Reprodutibilidade dos Testes , SARS-CoV-2/química , Sensibilidade e Especificidade
6.
Int J Tryptophan Res ; 13: 1178646920978241, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33354112

RESUMO

The kynurenine pathway of tryptophan degradation produces several neuroactive metabolites suggested to be involved in a wide variety of diseases and disorders, however, technical challenges in reliably detecting these metabolites hampers cross-comparisons. The main objective of this study was to develop an accurate, robust and precise bioanalytical method for simultaneous quantification of ten plasma kynurenine metabolites. As a secondary aim, we applied this method on blood samples taken from healthy subjects conducting 1 session of sprint interval exercise (SIE). It is well accepted that physical exercise is associated with health benefits and reduces risks of psychiatric illness, diabetes, cancer and cardiovascular disease, but also influences the peripheral and central concentrations of kynurenines. In line with this, we found that in healthy old adults (n = 10; mean age 64 years), levels of kynurenine increased 1 hour (P = .03) after SIE, while kynurenic acid (KYNA) concentrations were elevated after 24 hours (P = .02). In contrast, no significant changes after exercise were seen in young adults (n = 10; mean age 24 years). In conclusion, the described method performs well in reliably detecting all the analyzed metabolites in plasma samples. Furthermore, we also detected an age-dependent effect on the degree by which a single intense training session affects kynurenine metabolite levels.

7.
Bioanalysis ; 12(6): 379-392, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32209024

RESUMO

Aim: Kynurenine metabolites are potential modulators of psychiatric disease. We aimed to develop a highly sensitive biochemical analysis of cerebrospinal fluid (CSF) tryptophan (TRP) metabolites, to investigate the stability of metabolites and to confirm our previous findings of aberrant CSF quinolinic acid (QUIN) and picolinic acid (PIC) in suicide attempters using this method. Methodology & results: Ten CSF TRP metabolites were analyzed with ultraperformance LC-MS/MS. The method showed small intra- and interassay variation. Metabolites were stable following freeze-thaw cycles. A decreased CSF PIC/QUIN ratio was found in suicide attempters. Conclusion: The feasibility of reliably determining CSF TRP metabolites were demonstrated, including separation of the two isomers PIC and nicotinic acid (NA) and the finding of a reduced PIC/QUIN ratio replicated in suicide attempters.


Assuntos
Cinurenina/líquido cefalorraquidiano , Transtornos Mentais/líquido cefalorraquidiano , Adulto , Estudos de Casos e Controles , Cromatografia Líquida/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/líquido cefalorraquidiano , Ácidos Picolínicos/líquido cefalorraquidiano , Ácido Quinolínico/líquido cefalorraquidiano , Tentativa de Suicídio , Espectrometria de Massas em Tandem/métodos , Triptofano/líquido cefalorraquidiano , Adulto Jovem
8.
Artigo em Inglês | MEDLINE | ID: mdl-24413020

RESUMO

The purpose of this work was to develop and evaluate a fast, robust and specific UPLC-MS/MS screening platform for the determination and quantification of a variety of commonly used drugs of abuse in urine, i.e. a high-throughput quantitative analysis. Substances in the drug classes opioids, central nervous system stimulants and benzodiazepines and related agents were included in addition to cannabis and pregabalin, a total of 35 different analytes. Based on the concentrations and the physico-chemical properties of the substances, three UPLC-MS/MS methods were developed in parallel. Prior to analysis, sample preparation consisted of two different simple dilutions with 60 and 100 µL urine, respectively, using a Tecan Freedom Evo pipetting robot platform. A Waters Xevo TQ-S tandem quadrupole mass spectrometer coupled to a Waters I-class UPLC was used for quantitative analysis of one quantitative and one qualifying MRM transition for each analyte, except for tramadol for which the metabolite O-desmethyl-tramadol was included in the MRM method to confirm tramadol identity. Deuterated analogs were included as internal standards. The between-assay relative standard deviations varied from 2% to 11% and the limits of quantification were in the range 1-200 ng/mL for the various analytes. After development and initial testing, the method has been successfully implemented and routinely used at our hospital for quantitative screening of drugs of abuse in more than 35,000 urinary samples.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Drogas Ilícitas/urina , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Transtornos Relacionados ao Uso de Substâncias/urina
9.
J Anal Toxicol ; 34(6): 332-41, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20663286

RESUMO

An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for detection of 23 benzodiazepines and related compounds in whole blood was developed and validated. The method is used for screening and quantitation of benzodiazepines in whole blood received from autopsy cases and living persons. The detected compounds were alprazolam, bromazepam, brotizolam, chlordiazepoxide, demoxepam, clobazam, clonazepam, 7-aminoclonazepam, diazepam, nordiazepam, estazolam, flunitrazepam, 7-aminoflunitrazepam, lorazepam, lormetazepam, midazolam, nitrazepam, 7-aminonitrazepam, oxazepam, temazepam, triazolam, zaleplon, and zopiclone. Whole blood from drug-free volunteers was used for all experiments. Blood samples (0.200 g) were extracted with ethyl acetate at pH 9. Target drugs were quantified using a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole in positive electrospray ionization, multiple reaction monitoring mode. The use of deuterated internal standards for most compounds verified that the accuracy of the method was not influenced by matrix effects. Extraction recoveries were 73-108% for all analytes. Lower limits of quantification ranged from 0.002 to 0.005 mg/kg. Long-term imprecision (CV%) ranged from 6.0 to 18.7%. We present a fully validated UPLC-MS-MS method for 23 benzodiazepines in whole blood with a run-time of only 5 min and using only 0.200 g of whole blood.


Assuntos
Acetamidas/sangue , Compostos Azabicíclicos/sangue , Benzodiazepinas/sangue , Cromatografia Líquida , Piperazinas/sangue , Pirimidinas/sangue , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem , Acetamidas/isolamento & purificação , Compostos Azabicíclicos/isolamento & purificação , Benzodiazepinas/isolamento & purificação , Humanos , Piperazinas/isolamento & purificação , Pirimidinas/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA