Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Clin Virol ; 173: 105689, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38781633

RESUMO

BACKGROUND: HDV antibody testing is recommended for universal screening and as the first line in an HDV double reflex testing strategy for effectively identifying patients with active infection for therapeutic treatments. OBJECTIVE: The aim of this study is to evaluate the performance of a newly developed ARCHITECT HDV Total Ig (ARCHITECT HDV Ig) prototype assay. STUDY DESIGN: Performance characteristics were determined for the ARCHITECT HDV Ig and a reference test, LIAISON XL Anti-HDV using a well-characterized specimen panel, comprising HDV RNA positive (n = 62) and negative (n = 70) samples, and healthy US blood donors. RESULTS: Healthy US blood donors (n=200) showed 99.5% (199/200, 95%CI=97.65-99.98) specificity with ARCHITECT HDV Ig and 98.5 % (197/200, 95 %CI = 96.10-99.64) with LIAISON Anti-HDV. Among known HDV RNA positive samples, ARCHITECT HDV Ig detected 59/62 demonstrating 95.2 % sensitivity while LIAISON Anti-HDV sensitivity was 90.3 % (56/62). Among 101 HBV positive samples, 70 were reactive in the ARCHITECT test, 59 of which tested positive for HDV RNA for a positive predictive value (PPV) for the presence of HDV RNA was 84.3 %. For LIAISON Anti-HDV, 79 specimens were reactive and 56 contained HDV RNA: PPV for HDV RNA was 70.9 %. Among 70 HDV RNA negative samples, 39 were HBV positive. ARCHITECT HDV Ig negative predictive value (NPV) was 71.8 % and LIAISON Anti-HDV NPV was 41 % for the HBV positive group, respectively. CONCLUSION: When compared to the LIASON Anti-HDV test, the ARCHITECT HDV Ig assay demonstrated enhanced sensitivity and specificity and better NPV and PPV values for HDV RNA status. The ARCHITECT HDV Ig assay represents a promising tool for universal screening of all HBsAg-positive persons.


Assuntos
Anticorpos Anti-Hepatite , Hepatite D , Vírus Delta da Hepatite , Ensaios de Triagem em Larga Escala , Sensibilidade e Especificidade , Humanos , Hepatite D/diagnóstico , Hepatite D/imunologia , Vírus Delta da Hepatite/imunologia , Vírus Delta da Hepatite/genética , Vírus Delta da Hepatite/isolamento & purificação , Anticorpos Anti-Hepatite/sangue , Ensaios de Triagem em Larga Escala/métodos , Testes Sorológicos/métodos , Automação Laboratorial/métodos , Doadores de Sangue
2.
J Infect Dis ; 229(Supplement_2): S137-S143, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-37739785

RESUMO

BACKGROUND: The 2022 outbreak of the clade IIb monkeypox virus and subsequent global spread lead to an urgent need for the development of high-throughput, sensitive, and reproducible diagnostic tests. METHODS: We developed 3 assays to detect monkeypox virus, 2 (MPXV+ and MPXV) for m2000 RealTime and 1 (MPXV) for Alinity m platforms. Dual targets in E9L and B6R (MPXV+) and J2L and B7R (MPXV) increased mutation resistance. In silico prediction indicates MPXV+ cross-reactivity with orthopox viruses and specific monkeypox virus detection with MPXV. RESULTS: m2000 RealTime MPXV+ and MPXV assay sensitivity was determined to be 3.2 plaque-forming units/mL using a reference virus culture diluted into universal transport medium (UTM). Alinity m MPXV lower limit of detection was 200 copies/mL using monkeypox virus plasmids in pooled UTM matrix. m2000 RealTime MPXV+ and MPXV assays were validated with lesion swabs in UTM and 1:1 saliva to UTM mixtures. Commercially available and remnant clinical lesion specimens in UTM were tested with RealTime MPXV+, RealTime MPXV and Alinity m MPXV assays and demonstrated high agreement to known mpox (MPX)-positive specimens. CONCLUSIONS: RealTime MPXV+, RealTime MPXV, and Alinity MPXV are high throughput and sensitive assays used for the detection of monkeypox virus. These assays maybe useful during MPX outbreaks.


Assuntos
Mpox , Humanos , Bioensaio , Reações Cruzadas , Meios de Cultura , Surtos de Doenças , Monkeypox virus
3.
J Clin Virol ; 166: 105532, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37459763

RESUMO

BACKGROUND: The SARS-CoV-2 pandemic saw the rapid rise, global spread, and diversification of the omicron variant in 2022. Given the overwhelming dominance of this variant globally and its diverse lineages, there is an urgent need to ensure that diagnostic assays are capable of detecting widely circulating omicron sub-lineages. STUDY DESIGN: Remnant clinical VTM samples from SARS-CoV-2 PCR confirmed infections (n = 733) collected in Wisconsin (n = 94), New York (n = 267), and South Carolina (n = 372) throughout 2022 were sequenced, classified, and tested with m2000 RealTime SARS-CoV-2, Alinity m SARS-CoV-2, ID NOW COVID-19 v2.0, BinaxNOW COVID-19 Ag Card, and Panbio COVID-19 Rapid Test Device assays. RESULTS: Sequences and lineage classifications were obtained for n = 641/733 (87.4%) samples and included delta (n = 6) and representatives from all major SARS-CoV-2 omicron variants circulating in 2022 (BA.1, BA.2, BA.3, BA.4, BA.5, BE, BF, BQ.1, and XBB). Panels of diverse omicron lineages were tested by molecular assays RealTime (n = 624), Alinity m (n = 80), and ID NOW v2.0 (n = 88) with results showing 100% detection for all samples. BinaxNOW and Panbio had sensitivities of 494/533 (92.7%) and 416/469 (88.7%), respectively for specimens with >4 log10 copies/test, consistent with expected performance for frozen specimens. Furthermore, BinaxNOW demonstrated SARS-CoV-2 detection in clinical samples 1-4 days, and up to 18 days post-symptom onset in BA.1 infected patients with >4 log10 copies/test. CONCLUSIONS: This data highlights the rise and diversification of SARS-CoV-2 omicron variants over the course of 2022 and demonstrate that each of the 5 tested assays can detect the breadth of omicron variants circulating globally.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Bioensaio , Testes Imunológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...