Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(20)2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33050252

RESUMO

Silver nanoplates (AgP) were prepared and used in a colorimetric method for the evaluation of Xanthine (Xan) in blood plasma and fish meat. The detection mechanism for Xan was observed to occur via etching of AgP particles/aggregation/fusion steps, resulting in a color change from blue to grey. First, the basic Xan solution is adsorbed through partial substitution of capping molecules around the AgP with Xan, and then intermolecular hydrogen bonds form between AgP and AgP. Subsequently, the titrant Xan solution further etches the AgP and finally fuses particles together. Owing to the step by step mechanism, the response range towards Xan has two linear regression ranges: 0.15-0.60 µM and 0.61-3.00 µM, respectively. The detection limit in the range of 0.15-0.60 µM is 0.011 µM (S/N = 3). AgP exhibits good selectivity for Xan over other potential interferents such as amino acids and blood proteins. AgP achieves rapid detection of Xan and can be applied to the satisfactory determination of Xan in blood plasma and fish meat. This colorimetric sensor is easy to use, cost effective, fast, selective and user friendly.


Assuntos
Colorimetria , Nanopartículas Metálicas , Prata , Animais , Humanos , Carne , Plasma , Xantina
2.
RSC Adv ; 10(45): 27042-27049, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35515798

RESUMO

The commercially-available colorimetric urine dipstic for the early detection of urinary tract infection (UTI) has several limitations. The quantitative determination of urinary leukocyte esterase (LE) for predicting UTI remains uncertain. This study presents a paper-based analytical device to detect LE (LE-PAD) as a point-of-care quantitative test for UTI. The LE-PAD is composed of a coating of mixed 3-(N-tosyl-L-alaninyloxy)-5-phenylpyrrole (PE) and 1-diazo-2-naphthol-4-sulfonic acid (DAS) deposited onto a silver conducting film (Ag film). The LE/urine reacts with the PE and DAS, and the resulting products in turn react with the silver coating, causing a change in resistivity. The quantitative calibration curve was established in this study and has been used to analyse urine samples from inpatients with urinary catheters (n = 21). The results revealed that the level of LE determined by LE-PADs was predictive of UTI diagnosis with an area under the receiver operating characteristic curve of 0.875 (95% confidence interval, 0.704-1.000). Using an appropriate cut-off value, the sensitivity and specificity of UTI diagnosis by LE-PAD were 87.5% and 92.3%, while the LE-positivities of urine dipstics were 62.5% and 76.9%, respectively. For UTI diagnosis, the LE-PAD demonstrated positive and negative likelihood ratios of 11.38 and 0.14, suggesting that the novel LE-PAD is a reliable test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...