Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Resuscitation ; 202: 110354, 2024 09.
Artigo em Inglês | MEDLINE | ID: mdl-39122176

RESUMO

AIM OF THE STUDY: We evaluated whether an artificial intelligence (AI)-driven robot cardiopulmonary resuscitation (CPR) could improve hemodynamic parameters and clinical outcomes. METHODS: We developed an AI-driven CPR robot which utilizes an integrated feedback system with an AI model predicting carotid blood flow (CBF). Twelve pigs were assigned to the AI robot group (n = 6) and the LUCAS 3 group (n = 6). They underwent 6 min of CPR after 7 min of ventricular fibrillation. In the AI robot group, the robot explored for the optimal compression position, depth and rate during the first 270-second period, and continued CPR with the optimal setup during the next 90-second period and beyond. The primary outcome was CBF during the last 90-second period. The secondary outcomes were coronary perfusion pressure (CPP), end-tidal carbon dioxide level (ETCO2) and return of spontaneous circulation (ROSC). RESULTS: The AI model's prediction performance was excellent (Pearson correlation coefficient = 0.98). CBF did not differ between the two groups [estimate and standard error (SE), -23.210 ± 20.193, P = 0.250]. CPP, ETCO2 level and rate of ROSC also did not show difference [estimate and SE, -0.214 ± 7.245, P = 0.976 for CPP; estimate and SE, 1.745 ± 3.199, P = 0.585 for ETCO2; 5/6 (83.3%) vs. 4/6 (66.7%), P = 1.000 for ROSC). CONCLUSION: This study provides proof of concept that an AI-driven CPR robot in porcine cardiac arrest is feasible. Compared to a LUCAS 3, an AI-driven CPR robot produced comparable hemodynamic and clinical outcomes.


Assuntos
Inteligência Artificial , Reanimação Cardiopulmonar , Parada Cardíaca , Robótica , Animais , Reanimação Cardiopulmonar/métodos , Reanimação Cardiopulmonar/instrumentação , Suínos , Robótica/instrumentação , Robótica/métodos , Parada Cardíaca/terapia , Parada Cardíaca/fisiopatologia , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Fibrilação Ventricular/terapia , Fibrilação Ventricular/fisiopatologia , Artérias Carótidas/fisiopatologia
2.
PLoS One ; 19(1): e0297057, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38241416

RESUMO

BACKGROUND: Recently, we developed a chest compression device that can move the chest compression position without interruption during CPR and be remotely controlled to minimize rescuer exposure to infectious diseases. The purpose of this study was to compare its performance with conventional mechanical CPR device in a mannequin and a swine model of cardiac arrest. MATERIALS AND METHODS: A prototype of a remote-controlled automatic chest compression device (ROSCER) that can change the chest compression position without interruption during CPR was developed, and its performance was compared with LUCAS 3 in a mannequin and a swine model of cardiac arrest. In a swine model of cardiac arrest, 16 male pigs were randomly assigned into the two groups, ROSCER CPR (n = 8) and LUCAS 3 CPR (n = 8), respectively. During 5 minutes of CPR, hemodynamic parameters including aortic pressure, right atrial pressure, coronary perfusion pressure, common carotid blood flow, and end-tidal carbon dioxide partial pressure were measured. RESULTS: In the compression performance test using a mannequin, compression depth, compression time, decompression time, and plateau time were almost equal between ROSCER and LUCAS 3. In a swine model of cardiac arrest, coronary perfusion pressure showed no difference between the two groups (p = 0.409). Systolic aortic pressure and carotid blood flow were higher in the LUCAS 3 group than in the ROSCER group during 5 minutes of CPR (p < 0.001, p = 0.008, respectively). End-tidal CO2 level of the ROSCER group was initially lower than that of the LUCAS 3 group, but was higher over time (p = 0.022). A Kaplan-Meier survival analysis for ROSC also showed no difference between the two groups (p = 0.46). CONCLUSION: The prototype of a remote-controlled automated chest compression device can move the chest compression position without interruption during CPR. In a mannequin and a swine model of cardiac arrest, the device showed no inferior performance to a conventional mechanical CPR device.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Masculino , Animais , Suínos , Projetos Piloto , Manequins , Parada Cardíaca/terapia , Pressão , Hemodinâmica
3.
IEEE J Transl Eng Health Med ; 10: 2100111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34976445

RESUMO

Background: The lumbar stabilization exercise is one of the most recommended treatments in medical professionals for patients suffering from low back pain. However, because lumbar stabilization exercise is calisthenics, it is challenging to perform because of the body load of the elderly, disabled, and patients that lack muscle strength. Additionally, it interferes with the effect of exercise because it can strain parts of the body. Methods: To overcome them, a compliant anti-gravity rehabilitation proto-type device using the Series Elastic Actuator (SEA) was developed previously to provide quantitative assist force to the person, producing similar exercise effects with calisthenics. From an exercise experiment with 20 participants, it caused discomfort to participants during exercise owing to the non-ergonomic design of the previous device. Different muscle activation tendencies were observed between calisthenics and exercise using the device. For advanced technical solutions to clinical needs, which is exercise using the rehabilitation robot to produce a similar effect to calisthenics, the mechanical design of the rehabilitation robot was improved based on the previous device after receiving feedback from clinical trials and static analysis. For the safety of exercise using the robot, a cascade PID-PI controller was used to reduce the influence of friction and disturbance due to the external movement. Results: Surface electromyography(sEMG) signal from lumbar muscles showed desired monotonic reduction ratio and higher similarity results compared to the previous device, which proved the exercise effectiveness using the robot. Conclusion: The proposed robot is considered as a solution to a clinical need of lumbar rehabilitation for the elderly, disabled, and patients.


Assuntos
Dor Lombar , Robótica , Idoso , Eletromiografia/métodos , Exercício Físico , Humanos , Dor Lombar/terapia , Região Lombossacral