Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Appl Toxicol ; 44(4): 510-525, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37897225

RESUMO

The Epidermal Sensitization Assay (EpiSensA) is a reconstructed human epidermis (RhE)-based gene expression assay for predicting the skin sensitization potential of chemicals. Since the RhE model is covered by a stratified stratum corneum, various kinds of test chemicals, including lipophilic ones and pre-/pro-haptens, can be tested with a route of exposure akin to an in vivo assay and human exposure. This article presents the results of a formally managed validation study of the EpiSensA that was carried out by three participating laboratories. The purpose of this validation study was to assess transferability of the EpiSensA to new laboratories along with its within- (WLR) and between-laboratory reproducibility (BLR). The validation study was organized into two independent stages. As demonstrated during the first stage, where three sensitizers and one non-sensitizer were correctly predicted by all participating laboratories, the EpiSensA was successfully transferred to all three participating laboratories. For Phase I of the second stage, each participating laboratory performed three experiments with an identical set of 15 coded test chemicals resulting in WLR of 93.3%, 93.3%, and 86.7%, respectively. Furthermore, when the results from the 15 test chemicals were combined with those of the additional 12 chemicals tested in Phase II of the second stage, the BLR for 27 test chemicals was 88.9%. Moreover, the predictive capacity among the three laboratories showed 92.6% sensitivity, 63.0% specificity, 82.7% accuracy, and 77.8% balanced accuracy based on murine local lymph node assay (LLNA) results. Overall, this validation study concluded that EpiSensA is easily transferable and sufficiently robust for assessing the skin sensitization potential of chemicals.


Assuntos
Alérgenos , Dermatite Alérgica de Contato , Humanos , Animais , Camundongos , Reprodutibilidade dos Testes , Alérgenos/toxicidade , Epiderme , Pele , Haptenos/toxicidade , Ensaio Local de Linfonodo , Alternativas aos Testes com Animais
2.
J Appl Toxicol ; 44(3): 415-427, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37846211

RESUMO

The hazards and potency of skin sensitizers are traditionally determined using animal tests such as the local lymph node assay (LLNA); however, significant progress has been made in the development of non-animal test methods addressing the first three mechanistic key events of adverse outcome pathway in skin sensitization. We developed the epidermal sensitization assay (EpiSensA), which is a reconstructed human epidermis-based assay, by measuring four genes related to critical keratinocyte responses during skin sensitization. Four in vitro skin sensitization test methods (EpiSensA, direct peptide reactivity assay [DPRA], KeratinoSens™, and human cell line activation test [h-CLAT]) were systematically evaluated using 136 chemicals including lipophilic chemicals and pre/pro-haptens, which may be related to assay-specific limitations. The constructed database included existing and newly generated data. The EpiSensA showed a broader applicability domain and predicted the hazards with 82.4% and 78.8% accuracy than LLNA and human data. The EpiSensA could detect 76 out of 88 sensitizers at lower concentrations than the LLNA, indicating that the EpiSensA has higher sensitivity for the detection of minor sensitizing constituents. These results confirmed the potential use of the EpiSensA in evaluating a mixture of unknown compositions that can be evaluated by animal tests. To combine different information sources, the reconstructed human epidermis-based testing strategy (RTS) was developed based on weighted multiple information from the EpiSensA and TImes MEtabolism Simulator platform for predicting Skin Sensitization (TIMES-SS; RTSv1) or Organization for Economic Cooperation and Development (OECD) QSAR Toolbox automated workflow (RTSv2). The predictivities of the hazards and Globally Harmonized System (GHS) subcategories were equal to or better than the defined approaches (2 out of 3, integrated testing strategy [ITS]v1, and ITSv2) adopted as OECD Guideline 497.


Assuntos
Alternativas aos Testes com Animais , Dermatite Alérgica de Contato , Animais , Humanos , Alternativas aos Testes com Animais/métodos , Pele , Epiderme , Queratinócitos/metabolismo , Testes Cutâneos , Ensaio Local de Linfonodo , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/metabolismo
3.
J Appl Toxicol ; 42(6): 1029-1043, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34927266

RESUMO

Demands for the elimination and replacement of animal experiments for cosmetic safety assessment have increased in recent years. Evaluation of skin sensitization, however, is a critical issue in cosmetic safety assessment. The SH test is an in vitro skin sensitization test method that evaluates protein binding of chemical substances, which is an important event in skin sensitization. We previously verified the technical transferability and between-laboratory reproducibility of the SH test, a domestic test method for which no scientific research has been conducted, and improved the protocol, but also noted some unresolved issues. Therefore, in the present study, we successfully improved the operational efficiency and clarity of the final judgment of the SH test by (i) developing a new decision-making system that can make a final judgment without statistical processing, (ii) changing the statistical method, and (iii) evaluating and determining the maximum number of repetitions necessary for optimal efficiency. The improved SH test was verified by comparing it with existing test methods already adopted by the Organization for Economic Cooperation and Development. The results of this study demonstrated excellent performance of the improved SH test, with high reproducibility, reliable predictability, and good operational efficiency. The predictive performance of the improved method does not differ significantly from that of the conventional method, although it is clearer and more efficient. Therefore, the results of the present improved method are consistent with those obtained using the conventional method, with higher efficiency.


Assuntos
Alternativas aos Testes com Animais , Cosméticos , Alternativas aos Testes com Animais/métodos , Animais , Árvores de Decisões , Reprodutibilidade dos Testes , Pele , Testes Cutâneos/métodos
4.
J Toxicol Sci ; 46(5): 235-248, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33952800

RESUMO

There has been an increased demand to eliminate animal experiments and to replace the experiments with alternative tests for assessing the safety of cosmetics. The SH test is an in vitro skin sensitization test that evaluates the protein binding abilities of a test substance. Skin sensitization must be evaluated by multiple test methods. The SH test uses the same cell line and measuring instruments as the human Cell-Line Activation Test (h-CLAT), which is one of the test methods used to evaluate different key events and is listed in the OECD test guidelines. There are cost advantages to usher the SH test into facilities that are already running the h-CLAT. The SH test is conducted only at a facility that has developed the SH test because studies on the between-facility reproducibility and validity have not been performed. Therefore, to verify the transferability of the SH test and the between-facilities reproducibility, we evaluated the reproducibility of the SH test results at three facilities, including the development facility. After an initial round of testing, the protocol was refined as follows to improve reproducibility among the three facilities: i) determine the optimum pH range, ii) change the maximum applicable concentration of water-soluble substances, and iii) define the appropriate dispersion conditions for evaluating hydrophobic substances. These refinements markedly enhanced the between-facility reproducibility (from 76.0% to 96.0%) for the 25 substances evaluated in this study. This study confirmed that the SH test is an effective skin sensitization test method with high technical transferability and between-facility reproducibility.


Assuntos
Dermatite Alérgica de Contato , Haptenos/toxicidade , Laboratórios/normas , Testes de Toxicidade/métodos , Testes de Toxicidade/normas , Alternativas aos Testes com Animais/métodos , Alternativas aos Testes com Animais/normas , Linhagem Celular , Humanos , Reprodutibilidade dos Testes
5.
J Toxicol Sci ; 43(12): 751-768, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30518713

RESUMO

The Organisation for Economic Co-operation and Development (OECD) Test Guideline (TG) 439 is an in vitro test method of reconstructed human epidermis (RhE), which was developed for hazard identification of irritating chemicals in accordance with a primary skin irritation test using rabbits with 4-hr exposure. A regulation for quasi-drugs in Japan requires data from primary skin irritation tests using rabbits to undergo 24-hr exposure, and this is used as an evidence for 24-hr closed patch tests in humans. In this study with the same chemicals, primary skin irritation test data using rabbits undergoing 24-hr exposure and a 24-hr occlusive human patch test data were analyzed by comparing the results obtained with four test methods adopted in OECD TG 439. The performances of in vitro test methods showed a positive predictive value of 72.7-85.7% to predict the results of 24-hr primary rabbit skin irritation test knowing that its positive predictive value was 57.1% against humans only. The prediction factors of in vitro test methods were higher for the human patch test data with a sensitivity reaching 60 to 80%. Three surfactants gave false negatives in some of the RhE methods evaluated with the human patch test, but in each case, they were correctly classified as positive when evaluated at double concentration. Therefore, the approach of setting the margin to 2 was effective in eliminating false negatives. This suggests that in vitro test methods are useful for assessing skin irritation potential without animal testing for the application of quasi-drugs in Japan.


Assuntos
Alternativas aos Testes com Animais , Irritantes/toxicidade , Testes do Emplastro , Testes de Irritação da Pele , Animais , Humanos , Organização para a Cooperação e Desenvolvimento Econômico , Coelhos
6.
J Appl Toxicol ; 38(9): 1233-1243, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29722446

RESUMO

The epidermal sensitization assay (EpiSensA) is an in vitro skin sensitization test method based on gene expression of four markers related to the induction of skin sensitization; the assay uses commercially available reconstructed human epidermis. EpiSensA has exhibited an accuracy of 90% for 72 chemicals, including lipophilic chemicals and pre-/pro-haptens, when compared with the results of the murine local lymph node assay. In this work, a ring study was performed by one lead and two naive laboratories to evaluate the transferability, as well as within- and between-laboratory reproducibilities, of EpiSensA. Three non-coded chemicals (two lipophilic sensitizers and one non-sensitizer) were tested for the assessment of transferability and 10 coded chemicals (seven sensitizers and three non-sensitizers, including four lipophilic chemicals) were tested for the assessment of reproducibility. In the transferability phase, the non-coded chemicals (two sensitizers and one non-sensitizer) were correctly classified at the two naive laboratories, indicating that the EpiSensA protocol was transferred successfully. For the within-laboratory reproducibility, the data generated with three coded chemicals tested in three independent experiments in each laboratory gave consistent predictions within laboratories. For the between-laboratory reproducibility, 9 of the 10 coded chemicals tested once in each laboratory provided consistent predictions among the three laboratories. These results suggested that EpiSensA has good transferability, as well as within- and between-laboratory reproducibility.


Assuntos
Dermatite Alérgica de Contato/etiologia , Epiderme/efeitos dos fármacos , Irritantes/toxicidade , Queratinócitos/efeitos dos fármacos , Ensaio de Proficiência Laboratorial , Testes de Irritação da Pele/métodos , Fator 3 Ativador da Transcrição/genética , Células Cultivadas , Dermatite Alérgica de Contato/genética , Epiderme/metabolismo , Regulação da Expressão Gênica/efeitos dos fármacos , Marcadores Genéticos , Glutamato-Cisteína Ligase/genética , Proteínas de Choque Térmico HSP40/genética , Humanos , Interleucina-8/genética , Queratinócitos/metabolismo , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Medição de Risco
7.
J Appl Toxicol ; 35(11): 1333-47, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25824844

RESUMO

The skin sensitization potential of chemicals has been determined with the use of the murine local lymph node assay (LLNA). However, in recent years public concern about animal welfare has led to a requirement for non-animal risk assessment systems for the prediction of skin sensitization potential, to replace LLNA. Selection of an appropriate in vitro test or in silico model descriptors is critical to obtain good predictive performance. Here, we investigated the utility of artificial neural network (ANN) prediction models using various combinations of descriptors from several in vitro sensitization tests. The dataset, collected from published data and from experiments carried out in collaboration with the Japan Cosmetic Industry Association (JCIA), consisted of values from the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA), SH test and antioxidant response element (ARE) assay for chemicals whose LLNA thresholds have been reported. After confirming the relationship between individual in vitro test descriptors and the LLNA threshold (e.g. EC3 value), we used the subsets of chemicals for which the requisite test values were available to evaluate the predictive performance of ANN models using combinations of h-CLAT/DPRA (N = 139 chemicals), the DPRA/ARE assay (N = 69), the SH test/ARE assay (N = 73), the h-CLAT/DPRA/ARE assay (N = 69) and the h-CLAT/SH test/ARE assay (N = 73). The h-CLAT/DPRA, h-CLAT/DPRA/ARE assay and h-CLAT/SH test/ARE assay combinations showed a better predictive performance than the DPRA/ARE assay and the SH test/ARE assay. Our data indicates that the descriptors evaluated in this study were all useful for predicting human skin sensitization potential, although combinations containing h-CLAT (reflecting dendritic cell-activating ability) were most effective for ANN-based prediction.


Assuntos
Alternativas aos Testes com Animais/métodos , Redes Neurais de Computação , Testes Cutâneos/métodos , Pele/metabolismo , Linhagem Celular , Células Dendríticas/metabolismo , Humanos , Ensaio Local de Linfonodo , Medição de Risco , Sensibilidade e Especificidade
8.
J Appl Toxicol ; 35(11): 1318-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25820183

RESUMO

To develop a testing strategy incorporating the human cell line activation test (h-CLAT), direct peptide reactivity assay (DPRA) and DEREK, we created an expanded data set of 139 chemicals (102 sensitizers and 37 non-sensitizers) by combining the existing data set of 101 chemicals through the collaborative projects of Japan Cosmetic Industry Association. Of the additional 38 chemicals, 15 chemicals with relatively low water solubility (log Kow > 3.5) were selected to clarify the limitation of testing strategies regarding the lipophilic chemicals. Predictivities of the h-CLAT, DPRA and DEREK, and the combinations thereof were evaluated by comparison to results of the local lymph node assay. When evaluating 139 chemicals using combinations of three methods based on integrated testing strategy (ITS) concept (ITS-based test battery) and a sequential testing strategy (STS) weighing the predictive performance of the h-CLAT and DPRA, overall similar predictivities were found as before on the 101 chemical data set. An analysis of false negative chemicals suggested a major limitation of our strategies was the testing of low water-soluble chemicals. When excluded the negative results for chemicals with log Kow > 3.5, the sensitivity and accuracy of ITS improved to 97% (91 of 94 chemicals) and 89% (114 of 128). Likewise, the sensitivity and accuracy of STS to 98% (92 of 94) and 85% (111 of 129). Moreover, the ITS and STS also showed good correlation with local lymph node assay on three potency classifications, yielding accuracies of 74% (ITS) and 73% (STS). Thus, the inclusion of log Kow in analysis could give both strategies a higher predictive performance.


Assuntos
Alternativas aos Testes com Animais/métodos , Cosméticos/toxicidade , Pele/efeitos dos fármacos , Linhagem Celular , Cosméticos/química , Determinação de Ponto Final , Humanos , Ensaio Local de Linfonodo , Peptídeos/química , Valor Preditivo dos Testes , Medição de Risco , Sensibilidade e Especificidade , Testes Cutâneos , Solubilidade , Testes de Toxicidade , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...