Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Front Neurorobot ; 18: 1383089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39381774

RESUMO

Human activity recognition (HAR) and brain-machine interface (BMI) are two emerging technologies that can enhance human-robot collaboration (HRC) in domains such as industry or healthcare. HAR uses sensors or cameras to capture and analyze the movements and actions of humans, while BMI uses human brain signals to decode action intentions. Both technologies face challenges impacting accuracy, reliability, and usability. In this article, we review the state-of-the-art techniques and methods for HAR and BMI and highlight their strengths and limitations. We then propose a hybrid framework that fuses HAR and BMI data, which can integrate the complementary information from the brain and body motion signals and improve the performance of human state decoding. We also discuss our hybrid method's potential benefits and implications for HRC.

2.
Front Hum Neurosci ; 18: 1390714, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39086374

RESUMO

Error-related potentials (ErrPs) are brain signals known to be generated as a reaction to erroneous events. Several works have shown that not only self-made errors but also mistakes generated by external agents can elicit such event-related potentials. The possibility of reliably measuring ErrPs through non-invasive techniques has increased the interest in the brain-computer interface (BCI) community in using such signals to improve performance, for example, by performing error correction. Extensive calibration sessions are typically necessary to gather sufficient trials for training subject-specific ErrP classifiers. This procedure is not only time-consuming but also boresome for participants. In this paper, we explore the effectiveness of ErrPs in closed-loop systems, emphasizing their dependency on precise single-trial classification. To guarantee the presence of an ErrPs signal in the data we employ and to ensure that the parameters defining ErrPs are systematically varied, we utilize the open-source toolbox SEREEGA for data simulation. We generated training instances and evaluated the performance of the generic classifier on both simulated and real-world datasets, proposing a promising alternative to conventional calibration techniques. Results show that a generic support vector machine classifier reaches balanced accuracies of 72.9%, 62.7%, 71.0%, and 70.8% on each validation dataset. While performing similarly to a leave-one-subject-out approach for error class detection, the proposed classifier shows promising generalization across different datasets and subjects without further adaptation. Moreover, by utilizing SEREEGA, we can systematically adjust parameters to accommodate the variability in the ErrP, facilitating the systematic validation of closed-loop setups. Furthermore, our objective is to develop a universal ErrP classifier that captures the signal's variability, enabling it to determine the presence or absence of an ErrP in real EEG data.

3.
Comput Biol Med ; 168: 107649, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37980798

RESUMO

OBJECTIVE: Bio-Signals such as electroencephalography (EEG) and electromyography (EMG) are widely used for the rehabilitation of physically disabled people and for the characterization of cognitive impairments. Successful decoding of these bio-signals is however non-trivial because of the time-varying and non-stationary characteristics. Furthermore, existence of short- and long-range dependencies in these time-series signal makes the decoding even more challenging. State-of-the-art studies proposed Convolutional Neural Networks (CNNs) based architectures for the classification of these bio-signals, which are proven useful to learn spatial representations. However, CNNs because of the fixed size convolutional kernels and shared weights pay only uniform attention and are also suboptimal in learning short-long term dependencies, simultaneously, which could be pivotal in decoding EEG and EMG signals. Therefore, it is important to address these limitations of CNNs. To learn short- and long-range dependencies simultaneously and to pay more attention to more relevant part of the input signal, Transformer neural network-based architectures can play a significant role. Nonetheless, it requires a large corpus of training data. However, EEG and EMG decoding studies produce limited amount of the data. Therefore, using standalone transformers neural networks produce ordinary results. In this study, we ask a question whether we can fix the limitations of CNN and transformer neural networks and provide a robust and generalized model that can simultaneously learn spatial patterns, long-short term dependencies, pay variable amount of attention to time-varying non-stationary input signal with limited training data. APPROACH: In this work, we introduce a novel single hybrid model called ConTraNet, which is based on CNN and Transformer architectures that contains the strengths of both CNN and Transformer neural networks. ConTraNet uses a CNN block to introduce inductive bias in the model and learn local dependencies, whereas the Transformer block uses the self-attention mechanism to learn the short- and long-range or global dependencies in the signal and learn to pay different attention to different parts of the signals. MAIN RESULTS: We evaluated and compared the ConTraNet with state-of-the-art methods on four publicly available datasets (BCI Competition IV dataset 2b, Physionet MI-EEG dataset, Mendeley sEMG dataset, Mendeley sEMG V1 dataset) which belong to EEG-HMI and EMG-HMI paradigms. ConTraNet outperformed its counterparts in all the different category tasks (2-class, 3-class, 4-class, 7-class, and 10-class decoding tasks). SIGNIFICANCE: With limited training data ConTraNet significantly improves classification performance on four publicly available datasets for 2, 3, 4, 7, and 10-classes compared to its counterparts.


Assuntos
Interfaces Cérebro-Computador , Aprendizado de Máquina , Humanos , Movimento , Redes Neurais de Computação , Algoritmos , Eletroencefalografia/métodos , Imaginação
4.
Biomed Eng Online ; 22(1): 63, 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37355651

RESUMO

BACKGROUND: The underlying motivation of this work is to demonstrate that artificial muscle activity of known and unknown motion can be generated based on motion parameters, such as angular position, acceleration, and velocity of each joint (or the end-effector instead), which are similarly represented in our brains. This model is motivated by the known motion planning process in the central nervous system. That process incorporates the current body state from sensory systems and previous experiences, which might be represented as pre-learned inverse dynamics that generate associated muscle activity. METHODS: We develop a novel approach utilizing recurrent neural networks that are able to predict muscle activity of the upper limbs associated with complex 3D human arm motions. Therefore, motion parameters such as joint angle, velocity, acceleration, hand position, and orientation, serve as input for the models. In addition, these models are trained on multiple subjects (n=5 including , 3 male in the age of 26±2 years) and thus can generalize across individuals. In particular, we distinguish between a general model that has been trained on several subjects, a subject-specific model, and a specific fine-tuned model using a transfer learning approach to adapt the model to a new subject. Estimators such as mean square error MSE, correlation coefficient r, and coefficient of determination R2 are used to evaluate the goodness of fit. We additionally assess performance by developing a new score called the zero-line score. The present approach was compared with multiple other architectures. RESULTS: The presented approach predicts the muscle activity for previously through different subjects with remarkable high precision and generalizing nicely for new motions that have not been trained before. In an exhausting comparison, our recurrent network outperformed all other architectures. In addition, the high inter-subject variation of the recorded muscle activity was successfully handled using a transfer learning approach, resulting in a good fit for the muscle activity for a new subject. CONCLUSIONS: The ability of this approach to efficiently predict muscle activity contributes to the fundamental understanding of motion control. Furthermore, this approach has great potential for use in rehabilitation contexts, both as a therapeutic approach and as an assistive device. The predicted muscle activity can be utilized to guide functional electrical stimulation, allowing specific muscles to be targeted and potentially improving overall rehabilitation outcomes.


Assuntos
Redes Neurais de Computação , Extremidade Superior , Humanos , Masculino , Adulto Jovem , Adulto , Fenômenos Biomecânicos , Movimento/fisiologia , Músculos , Eletromiografia/métodos
5.
J Neural Eng ; 19(5)2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36206722

RESUMO

Objective. Accurate decoding of surface electromyography (sEMG) is pivotal for muscle-to-machine-interfaces and their application e.g. rehabilitation therapy. sEMG signals have high inter-subject variability, due to various factors, including skin thickness, body fat percentage, and electrode placement. Deep learning algorithms require long training time and tend to overfit if only few samples are available. In this study, we aim to investigate methods to calibrate deep learning models to a new user when only a limited amount of training data is available.Approach. Two methods are commonly used in the literature, subject-specific modeling and transfer learning. In this study, we investigate the effectiveness of transfer learning using weight initialization for recalibration of two different pretrained deep learning models on new subjects data and compare their performance to subject-specific models. We evaluate two models on three publicly available databases (non invasive adaptive prosthetics database 2-4) and compare the performance of both calibration schemes in terms of accuracy, required training data, and calibration time.Main results. On average over all settings, our transfer learning approach improves 5%-points on the pretrained models without fine-tuning, and 12%-points on the subject-specific models, while being trained for 22% fewer epochs on average. Our results indicate that transfer learning enables faster learning on fewer training samples than user-specific models.Significance. To the best of our knowledge, this is the first comparison of subject-specific modeling and transfer learning. These approaches are ubiquitously used in the field of sEMG decoding. But the lack of comparative studies until now made it difficult for scientists to assess appropriate calibration schemes. Our results guide engineers evaluating similar use cases.


Assuntos
Algoritmos , Membros Artificiais , Humanos , Eletromiografia/métodos , Calibragem , Aprendizado de Máquina
6.
Front Hum Neurosci ; 16: 806517, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35814961

RESUMO

The human brain has been an object of extensive investigation in different fields. While several studies have focused on understanding the neural correlates of error processing, advances in brain-machine interface systems using non-invasive techniques further enabled the use of the measured signals in different applications. The possibility of detecting these error-related potentials (ErrPs) under different experimental setups on a single-trial basis has further increased interest in their integration in closed-loop settings to improve system performance, for example, by performing error correction. Fewer works have, however, aimed at reducing future mistakes or learning. We present a review focused on the current literature using non-invasive systems that have combined the ErrPs information specifically in a reinforcement learning framework to go beyond error correction and have used these signals for learning.

7.
Sci Rep ; 12(1): 4245, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35273310

RESUMO

Brain-computer interfaces (BCIs) enable communication between humans and machines by translating brain activity into control commands. Electroencephalography (EEG) signals are one of the most used brain signals in non-invasive BCI applications but are often contaminated with noise. Therefore, it is possible that meaningful patterns for classifying EEG signals are deeply hidden. State-of-the-art deep-learning algorithms are successful in learning hidden, meaningful patterns. However, the quality and the quantity of the presented inputs are pivotal. Here, we propose a feature extraction method called anchored Short Time Fourier Transform (anchored-STFT), which is an advanced version of STFT, as it minimizes the trade-off between temporal and spectral resolution presented by STFT. In addition, we propose a data augmentation method derived from l2-norm fast gradient sign method (FGSM), called gradient norm adversarial augmentation (GNAA). GNAA is not only an augmentation method but is also used to harness adversarial inputs in EEG data, which not only improves the classification accuracy but also enhances the robustness of the classifier. In addition, we also propose a CNN architecture, namely Skip-Net, for the classification of EEG signals. The proposed pipeline outperforms the current state-of-the-art methods and yields classification accuracies of 90.7% on BCI competition II dataset III and 89.5%, 81.8%, 76.0% and 85.4%, 69.1%, 80.9% on different data distributions of BCI Competition IV dataset 2b and 2a, respectively.


Assuntos
Interfaces Cérebro-Computador , Imaginação , Algoritmos , Eletroencefalografia/métodos , Análise de Fourier , Humanos , Redes Neurais de Computação
8.
J Neural Eng ; 18(1)2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33166944

RESUMO

Objective.Advancements in electrode design have resulted in micro-electrode arrays with hundreds of channels for single cell recordings. In the resulting electrophysiological recordings, each implanted electrode can record spike activity (SA) of one or more neurons along with background activity (BA). The aim of this study is to isolate SA of each neural source. This process is called spike sorting or spike classification. Advanced spike sorting algorithms are time consuming because of the human intervention at various stages of the pipeline. Current approaches lack generalization because the values of hyperparameters are not fixed, even for multiple recording sessions of the same subject. In this study, a fully automatic spike sorting algorithm called 'SpikeDeep-Classifier' is proposed. The values of hyperparameters remain fixed for all the evaluation data.Approach.The proposed approach is based on our previous study (SpikeDeeptector) and a novel background activity rejector (BAR), which are both supervised learning algorithms and an unsupervised learning algorithm (K-means). SpikeDeeptector and BAR are used to extract meaningful channels and remove BA from the extracted meaningful channels, respectively. The process of clustering becomes straight-forward once the BA is completely removed from the data. Then, K-means with a predefined maximum number of clusters is applied on the remaining data originating from neural sources only. Lastly, a similarity-based criterion and a threshold are used to keep distinct clusters and merge similar looking clusters. The proposed approach is called cluster accept or merge (CAOM) and it has only two hyperparameters (maximum number of clusters and similarity threshold) which are kept fixed for all the evaluation data after tuning.Main results.We compared the results of our algorithm with ground-truth labels. The algorithm is evaluated on data of human patients and publicly available labeled non-human primates (NHPs) datasets. The average accuracy of BAR on datasets of human patients is 92.3% which is further reduced to 88.03% after (K-means + CAOM). In addition, the average accuracy of BAR on a publicly available labeled dataset of NHPs is 95.40% which reduces to 86.95% after (K-mean + CAOM). Lastly, we compared the performance of the SpikeDeep-Classifier with two human experts, where SpikeDeep-Classifier has produced comparable results.Significance.The SpikeDeep-Classifier is evaluated on the datasets of multiple recording sessions of different species, different brain areas and different electrode types without further retraining. The results demonstrate that 'SpikeDeep-Classifier' possesses the ability to generalize well on a versatile dataset and henceforth provides a generalized and fully automated solution to offline spike sorting.Clinical trial registration numberThe clinical trial registration number for patients implanted with the Utah array isNCT 01849822.For the epilepsy patients, approval from the local ethics committee at the Ruhr-University Bochum, Germany, was obtained prior to implantation. The Clinical trial registration number for the epilepsy patients implanted with microwires is16-5670.


Assuntos
Aprendizado Profundo , Potenciais de Ação/fisiologia , Algoritmos , Animais , Eletrodos Implantados , Humanos , Neurônios/fisiologia , Processamento de Sinais Assistido por Computador
9.
J Neural Eng ; 16(5): 056003, 2019 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-31042684

RESUMO

OBJECTIVE: In electrophysiology, microelectrodes are the primary source for recording neural data (single unit activity). These microelectrodes can be implanted individually or in the form of arrays containing dozens to hundreds of channels. Recordings of some channels contain neural activity, which are often contaminated with noise. Another fraction of channels does not record any neural data, but only noise. By noise, we mean physiological activities unrelated to spiking, including technical artifacts and neural activities of neurons that are too far away from the electrode to be usefully processed. For further analysis, an automatic identification and continuous tracking of channels containing neural data is of great significance for many applications, e.g. automated selection of neural channels during online and offline spike sorting. Automated spike detection and sorting is also critical for online decoding in brain-computer interface (BCI) applications, in which only simple threshold crossing events are often considered for feature extraction. To our knowledge, there is no method that can universally and automatically identify channels containing neural data. In this study, we aim to identify and track channels containing neural data from implanted electrodes, automatically and more importantly universally. By universally, we mean across different recording technologies, different subjects and different brain areas. APPROACH: We propose a novel algorithm based on a new way of feature vector extraction and a deep learning method, which we call SpikeDeeptector. SpikeDeeptector considers a batch of waveforms to construct a single feature vector and enables contextual learning. The feature vectors are then fed to a deep learning method, which learns contextualized, temporal and spatial patterns, and classifies them as channels containing neural spike data or only noise. MAIN RESULTS: We trained the model of SpikeDeeptector on data recorded from a single tetraplegic patient with two Utah arrays implanted in different areas of the brain. The trained model was then evaluated on data collected from six epileptic patients implanted with depth electrodes, unseen data from the tetraplegic patient and data from another tetraplegic patient implanted with two Utah arrays. The cumulative evaluation accuracy was 97.20% on 1.56 million hand labeled test inputs. SIGNIFICANCE: The results demonstrate that SpikeDeeptector generalizes not only to the new data, but also to different brain areas, subjects, and electrode types not used for training. CLINICAL TRIAL REGISTRATION NUMBER: The clinical trial registration number for patients implanted with the Utah array is NCT01849822. For the epilepsy patients, approval from the local ethics committee at the Ruhr-University Bochum, Germany, was obtained prior to implantation.


Assuntos
Potenciais de Ação/fisiologia , Encéfalo/fisiologia , Aprendizado Profundo , Redes Neurais de Computação , Neurônios/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Quadriplegia/diagnóstico , Quadriplegia/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...