Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(5): e13906, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36691339

RESUMO

PURPOSE: Deep inspiration breath-hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left-sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT). MATERIALS AND METHODS: We examined intra- and inter-fraction positional variation of the left lung. Eight left-sided breast cancer patients were monitored with electronic portal imaging during breath-hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded. RESULTS: The mean intrafraction stability across all patients for the LLat field was 1.3 ± 0.7% and 1.5 ± 0.9% for VRT and ABC, respectively. Similarly, this was 1.5 ± 0.7% and 1.6 ± 0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0 ± 3.4% and 14.9 ± 6.0% for VRT and ABC, respectively. Similarly, this was 13.0 ± 2.5% and 14.8 ± 9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique. CONCLUSIONS: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline.


Assuntos
Neoplasias da Mama , Neoplasias Unilaterais da Mama , Humanos , Feminino , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Suspensão da Respiração , Coração
2.
Transplant Cell Ther ; 28(2): 113.e1-113.e8, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34775145

RESUMO

Total body irradiation is an important part of the conditioning regimens frequently used to prepare patients for allogeneic hematopoietic stem cell transplantation (SCT). Volumetric-modulated arc therapy enabled total body irradiation (VMAT-TBI), an alternative to conventional TBI (cTBI), is a novel radiotherapy treatment technique that has been implemented and investigated in our institution. The purpose of this study is to (1) report our six-year clinical experience in terms of treatment planning strategy and delivery time and (2) evaluate the clinical outcomes and toxicities in our cohort of patients treated with VMAT-TBI. This is a retrospective single center study. Forty-four patients at our institution received VMAT-TBI and chemotherapy conditioning followed by allogeneic SCT between 2014 and 2020. Thirty-two patients (73%) received standard-dose TBI (12-13.2 Gy in 6-8 fractions twice daily), whereas 12 (27%) received low-dose TBI (2-4 Gy in one fraction). Treatment planning, delivery, and treatment outcome data including overall survival (OS), relapse-free survival (RFS), and toxicities were analyzed. The developed VMAT-TBI planning strategy consistently generated plans satisfying our dose constraints, with planning target volume coverage >90%, mean lung dose ∼50% to 75% of prescription dose, and minimal hotspots in critical organs. Most of the treatment deliveries were <100 minutes (range 33-147, mean 72). The median follow-up was 26 months. At the last follow-up, 34 of 44 (77%) of patients were alive, with 1- and 2-year OS of 90% and 79% and RFS of 88% and 71%, respectively. The most common grade 3+ toxicities observed were mucositis (31 patients [71%]) and nephrotoxicity (6 patients [13%]), both of which were deemed multifactorial in cause. Four patients (9%) in standard-dose cohort developed grade 3+ pneumonitis, with 3 cases in the setting of documented respiratory infection and only 1 (2%) deemed likely related to radiation alone. VMAT-TBI provides a safe alternative to cTBI. The dose modulation capability of VMAT-TBI may lead to new treatment strategies, such as simultaneous boost and further critical organ sparing, for better malignant cell eradication, immune suppression, and lower toxicities.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Irradiação Corporal Total
3.
Cureus ; 13(3): e13998, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-33758727

RESUMO

The indications and techniques for the treatment of intracranial lesions continue to evolve with the advent of novel technologies. The Gamma Knife Icon™ (GK Icon™) is the most recent model available from Elekta, providing a frameless solution for stereotactic radiosurgery. At our institution, 382 patients with 3,213 separate intracranial lesions have been treated with frameless stereotactic radiotherapy using the GK Icon. The wide range of diagnoses include brain metastases, meningiomas, arteriovenous malformations, acoustic neuromas, pituitary adenomas, and several other histologies. The ability to perform both frame and frameless treatments on the GK Icon has significantly increased our daily volume by almost 50% on a single machine. Although the frameless approach allows one to take advantage of the precision in radiosurgery, the intricacies regarding treatment with this frameless system are not well established. Our initial experience will help to serve as a guide to those wishing to implement this novel technology in their practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...