Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Eur J Radiol ; 178: 111649, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39094464

RESUMO

PURPOSE: To create a simple model using standard BI-RADS® descriptors from pre-treatment B-mode ultrasound (US) combined with clinicopathological tumor features, and to assess the potential of the model to predict the presence of residual tumor after neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients. METHOD: 245 female BC patients receiving NAC between January 2017 and December 2019 were included in this retrospective study. Two breast imaging fellows independently evaluated representative B-mode tumor images from baseline US. Additional clinicopathological tumor features were retrieved. The dataset was split into 170 training and 83 validation cases. Logistic regression was used in the training set to identify independent predictors of residual disease post NAC and to create a model, whose performance was evaluated by ROC curve analysis in the validation set. The reference standard was postoperative histology to determine the absence (pathological complete response, pCR) or presence (non-pCR) of residual invasive tumor in the breast or axillary lymph nodes. RESULTS: 100 patients (40.8%) achieved pCR. Logistic regression demonstrated that tumor size, microlobulated margin, spiculated margin, the presence of calcifications, the presence of edema, HER2-positive molecular subtype, and triple-negative molecular subtype were independent predictors of residual disease. A model using these parameters demonstrated an area under the ROC curve of 0.873 in the training and 0.720 in the validation set for the prediction of residual tumor post NAC. CONCLUSIONS: A simple model combining standard BI-RADS® descriptors from pre-treatment B-mode breast US with clinicopathological tumor features predicts the presence of residual disease after NAC.


Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Neoplasia Residual , Ultrassonografia Mamária , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Neoplasias da Mama/terapia , Neoplasia Residual/diagnóstico por imagem , Pessoa de Meia-Idade , Ultrassonografia Mamária/métodos , Estudos Retrospectivos , Adulto , Idoso , Quimioterapia Adjuvante , Valor Preditivo dos Testes , Mama/diagnóstico por imagem , Mama/patologia
2.
BJR Open ; 6(1): tzae019, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39165295

RESUMO

Metabolic imaging in clinical practice has long relied on PET with fluorodeoxyglucose (FDG), a radioactive tracer. However, this conventional method presents inherent limitations such as exposure to ionizing radiation and potential diagnostic uncertainties, particularly in organs with heightened glucose uptake like the brain. This review underscores the transformative potential of traditional deuterium MR spectroscopy (MRS) when integrated with gradient techniques, culminating in an advanced metabolic imaging modality known as deuterium MRI (DMRI). While recent advancements in hyperpolarized MRS hold promise for metabolic analysis, their widespread clinical usage is hindered by cost constraints and the availability of hyperpolarizer devices or facilities. DMRI, also denoted as deuterium metabolic imaging (DMI), represents a pioneering, single-shot, and noninvasive paradigm that fuses conventional MRS with nonradioactive deuterium-labelled substrates. Extensively tested in animal models and patient cohorts, particularly in cases of brain tumours, DMI's standout feature lies in its seamless integration into standard clinical MRI scanners, necessitating only minor adjustments such as radiofrequency coil tuning to the deuterium frequency. DMRI emerges as a versatile tool for quantifying crucial metabolites in clinical oncology, including glucose, lactate, glutamate, glutamine, and characterizing IDH mutations. Its potential applications in this domain are broad, spanning diagnostic profiling, treatment response monitoring, and the identification of novel therapeutic targets across diverse cancer subtypes.

5.
Magn Reson Med Sci ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39010211

RESUMO

PURPOSE: Gadolinium-based contrast media (GBCM) may affect apparent diffusion coefficient measurements on diffusion-weighted imaging. We aimed at investigating the effect of GBCM and inter-reader variation on intravoxel incoherent motion (IVIM) parameters in breast lesions. METHODS: A total of 89 patients referred to 3T breast MRI with at least one histologically verified lesion were included. IVIM data were acquired using a single-shot echo planar imaging sequence before and after GBCM administration. D (true diffusion coefficient), D* (pseudo-diffusion coefficient) and f (perfusion fraction) were calculated and measured by two readers (R1, R2). Inter-reader and intra-reader agreements were assessed by intraclass correlation coefficients (ICCs) and Bland-Altman plots. RESULTS: D was comparable before and after GBCM administration and between readers. D* and f decreased after GBCM administration and showed a lower agreement between readers. Intra-reader agreement before and after GBCM administration was almost perfect for D for both R1 and R2 (ICC 0.955 and 0.887). The intra-reader agreement was substantial to moderate for D* (ICC R1 0.708, R2 0.583) and moderate for f (ICC R1 0.529 and R2 0.425). Inter-reader agreement before GBCM administration was almost perfect for D (ICC 0.905), substantial for D* (ICC 0.733), and moderate for f (ICC 0.404); after contrast media administration, it was almost perfect for D (ICC 0.876) and substantial for D* (ICC 0.654) and f (ICC 0.606). Bland-Altman plots revealed no significant bias. CONCLUSION: Administration of GBCM seems to have a stronger effect on D* and f values than on D values. This should be considered when applying IVIM in clinical practice.

6.
J Magn Reson Imaging ; 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38703143

RESUMO

Breast cancer is one of the most prevalent forms of cancer affecting women worldwide. Hypoxia, a condition characterized by insufficient oxygen supply in tumor tissues, is closely associated with tumor aggressiveness, resistance to therapy, and poor clinical outcomes. Accurate assessment of tumor hypoxia can guide treatment decisions, predict therapy response, and contribute to the development of targeted therapeutic interventions. Over the years, functional magnetic resonance imaging (fMRI) and magnetic resonance spectroscopy (MRS) techniques have emerged as promising noninvasive imaging options for evaluating hypoxia in cancer. Such techniques include blood oxygen level-dependent (BOLD) MRI, oxygen-enhanced MRI (OE) MRI, chemical exchange saturation transfer (CEST) MRI, and proton MRS (1H-MRS). These may help overcome the limitations of the routinely used dynamic contrast-enhanced (DCE) MRI and diffusion-weighted imaging (DWI) techniques, contributing to better diagnosis and understanding of the biological features of breast cancer. This review aims to provide a comprehensive overview of the emerging functional MRI and MRS techniques for assessing hypoxia in breast cancer, along with their evolving clinical applications. The integration of these techniques in clinical practice holds promising implications for breast cancer management. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.

7.
Magn Reson Imaging ; 110: 1-6, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38479541

RESUMO

PURPOSE: This pilot-study aims to assess, whether quantitatively assessed enhancing breast tissue as a percentage of the entire breast volume can serve as an indicator of breast cancer at breast MRI and whether the contrast-agent employed affects diagnostic efficacy. MATERIALS: This retrospective IRB-approved study, included 39 consecutive patients, that underwent two subsequent breast MRI exams for suspicious findings at conventional imaging with 0.1 mmol/kg gadobenic and gadoteric acid. Two independent readers, blinded to the histopathological outcome, assessed unenhanced and early post-contrast images using computer-assisted software (Brevis, Siemens Healthcare). Diagnostic performance was statistically determined for percentage of ipsilateral voxel volume enhancement and for percentage of contralateral enhancing voxel volume subtracted from ipsilateral enhancing voxel volume after crosstabulation with the dichotomized histological outcome (benign/malignant). RESULTS: Ipsilateral enhancing voxel volume versus histopathological outcome resulted in an AUC of 0.707 and 0.687 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.778 and 0.773 for gadoteric acid, reader 1 and 2, respectively. Accounting for background parenchymal enhancement by subtracting contralateral enhancing volume from ipsilateral enhancing voxel volume versus histolopathological outcome resulted in an AUC of 0.793 and 0.843 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.692 and 0.662 for gadoteric acid, reader 1 and 2, respectively. Pairwise testing yielded no statistically significant difference both between readers and between contrast agents employed (p > 0.05). CONCLUSION: Our proposed CAD algorithm, which quantitatively assesses enhancing breast tissue as a percentage of the entire breast volume, allows indicating the presence of breast cancer.


Assuntos
Neoplasias da Mama , Mama , Meios de Contraste , Imageamento por Ressonância Magnética , Compostos Organometálicos , Humanos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Projetos Piloto , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Meglumina/análogos & derivados , Reprodutibilidade dos Testes , Algoritmos , Sensibilidade e Especificidade
8.
Eur Radiol ; 34(7): 4764-4773, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38112765

RESUMO

OBJECTIVES: The aim of this study was to apply spatiotemporal analysis of contrast-enhanced ultrasound (CEUS) loops to quantify the enhancement heterogeneity for improving the differentiation between benign and malignant breast lesions. MATERIALS AND METHODS: This retrospective study included 120 women (age range, 18-82 years; mean, 52 years) scheduled for ultrasound-guided biopsy. With the aid of brightness-mode images, the border of each breast lesion was delineated in the CEUS images. Based on visual evaluation and quantitative metrics, the breast lesions were categorized into four grades of different levels of contrast enhancement. Grade-1 (hyper-enhanced) and grade-2 (partly-enhanced) breast lesions were included in the analysis. Four parameters reflecting enhancement heterogeneity were estimated by spatiotemporal analysis of neighboring time-intensity curves (TICs). By setting the threshold on mean parameter, the diagnostic performance of the four parameters for differentiating benign and malignant lesions was evaluated. RESULTS: Sixty-four of the 120 patients were categorized as grade 1 or 2 and used for estimating the four parameters. At the pixel level, mutual information and conditional entropy present significantly different values between the benign and malignant lesions (p < 0.001 in patients of grade 1, p = 0.002 in patients of grade 1 or 2). For the classification of breast lesions, mutual information produces the best diagnostic performance (AUC = 0.893 in patients of grade 1, AUC = 0.848 in patients of grade 1 or 2). CONCLUSIONS: The proposed spatiotemporal analysis for assessing the enhancement heterogeneity shows promising results to aid in the diagnosis of breast cancer by CEUS. CLINICAL RELEVANCE STATEMENT: The proposed spatiotemporal method can be developed as a standardized software to automatically quantify the enhancement heterogeneity of breast cancer on CEUS, possibly leading to the improved diagnostic accuracy of differentiation between benign and malignant lesions. KEY POINTS: • Advanced spatiotemporal analysis of ultrasound contrast-enhanced loops for aiding the differentiation of malignant or benign breast lesions. • Four parameters reflecting the enhancement heterogeneity were estimated in the hyper- and partly-enhanced breast lesions by analyzing the neighboring pixel-level time-intensity curves. • For the classification of hyper-enhanced breast lesions, mutual information produces the best diagnostic performance (AUC = 0.893).


Assuntos
Neoplasias da Mama , Meios de Contraste , Ultrassonografia Mamária , Humanos , Feminino , Pessoa de Meia-Idade , Adulto , Neoplasias da Mama/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Ultrassonografia Mamária/métodos , Diagnóstico Diferencial , Adolescente , Adulto Jovem , Análise Espaço-Temporal , Aumento da Imagem/métodos
9.
Eur J Radiol ; 169: 111185, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37939606

RESUMO

PURPOSE: We investigated the added value of two internationally used clinical decision rules in the management of enhancing lesions on breast MRI. METHODS: This retrospective, institutional review board approved study included consecutive patients from two different populations. Patients received breast MRI according to the recommendations of the European Society of Breast Imaging (EUSOBI). Initially, all examinations were assessed by expert readers without using clinical decision rules. All lesions rated as category 4 or 5 according to the Breast Imaging Reporting and Data System were histologically confirmed. These lesions were re-evaluated by an expert reader blinded to the histology. He assigned each lesion a Göttingen score (GS) and a Kaiser score (KS) on different occasions. To provide an estimate on inter-reader agreement, a second fellowship-trained reader assessed a subset of these lesions. Subgroup analyses based on lesion type (mass vs. non-mass), size (>1 cm vs. ≤ 1 cm), menopausal status, and significant background parenchymal enhancement were conducted. The areas under the ROC curves (AUCs) for the GS and KS were compared, and the potential to avoid unnecessary biopsies was determined according to previously established cutoffs (KS > 4, GS > 3) RESULTS: 527 lesions in 506 patients were included (mean age: 51.8 years, inter-quartile-range: 43.0-61.0 years). 131/527 lesions were malignant (24.9 %; 95 %-confidence-interval: 21.3-28.8). In all subgroups, the AUCs of the KS (median = 0.91) were higher than those of the GS (median = 0.83). Except for "premenopausal patients" (p = 0.057), these differences were statistically significant (p ≤ 0.01). Kappa agreement was higher for the KS (0.922) than for the GS (0.358). CONCLUSION: Both the KS and the GS provided added value for the management of enhancing lesions on breast MRI. The KS was superior to the GS in terms of avoiding unnecessary biopsies and showed superior inter-reader agreement; therefore, it may be regarded as the clinical decision rule of choice.


Assuntos
Neoplasias da Mama , Regras de Decisão Clínica , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Mama/patologia , Biópsia Guiada por Imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Sensibilidade e Especificidade
10.
Cancers (Basel) ; 15(20)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37894455

RESUMO

In this prospective study, 117 female patients (mean age = 53 years) with 127 histologically proven breast cancer lesions (lymph node (LN) positive = 85, LN negative = 42) underwent simultaneous 18F-FDG PET/MRI of the breast. Quantitative parameters were calculated from dynamic contrast-enhanced (DCE) imaging (tumor Mean Transit Time, Volume Distribution, Plasma Flow), diffusion-weighted imaging (DWI) (tumor ADCmean), and PET (tumor SUVmax, mean and minimum, SUVmean of ipsilateral breast parenchyma). Manual whole-lesion segmentation was also performed on DCE, T2-weighted, DWI, and PET images, and radiomic features were extracted. The dataset was divided into a training (70%) and a test set (30%). Multi-step feature selection was performed, and a support vector machine classifier was trained and tested for predicting axillary LN status. 13 radiomic features from DCE, DWI, T2-weighted, and PET images were selected for model building. The classifier obtained an accuracy of 79.8 (AUC = 0.798) in the training set and 78.6% (AUC = 0.839), with sensitivity and specificity of 67.9% and 100%, respectively, in the test set. A machine learning-based radiomics model comprising 18F-FDG PET/MRI radiomic features extracted from the primary breast cancer lesions allows high accuracy in non-invasive identification of axillary LN metastasis.

11.
Radiol Med ; 128(6): 689-698, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37221356

RESUMO

PURPOSE: To assess 18F-Fluoroethylcholine (18F-FEC) as a PET/MRI tracer in the evaluation of breast lesions, breast cancer aggressiveness, and prediction of lymph node status. MATERIALS AND METHODS: This prospective, monocentric study was approved by the ethics committee and patients gave written, informed consent. This clinical trial was registered in the EudraCT database (Number 2017-003089-29). Women who presented with suspicious breast lesions were included. Histopathology was used as reference standard. Simultaneous 18F-FEC PET/MRI of the breast was performed in a prone position with a dedicated breast coil. MRI was performed using a standard protocol before and after contrast agent administration. A simultaneous read by nuclear medicine physicians and radiologists collected the imaging data of MRI-detected lesions, including the maximum standardized 18F-FEC-uptake value of breast lesions (SUVmaxT) and axillary lymph nodes (SUVmaxLN). Differences in SUVmax were evaluated with the Mann-Whitney U test. To calculate diagnostic performance, the area under the receiver operating characteristics curve (ROC) was used. RESULTS: There were 101 patients (mean age 52.3 years, standard deviation 12.0) with 117 breast lesions included (30 benign, 7 ductal carcinomas in situ, 80 invasive carcinomas). 18F-FEC was well tolerated by all patients. The ROC to distinguish benign from malignant breast lesions was 0.846. SUVmaxT was higher if lesions were malignant (p < 0.001), had a higher proliferation rate (p = 0.011), and were HER2-positive (p = 0.041). SUVmaxLN was higher in metastatic lymph nodes, with an ROC of 0.761 for SUVmaxT and of 0.793 for SUVmaxLN. CONCLUSION: Simultaneous 18F-FEC PET/MRI is safe and has the potential to be used for the evaluation of breast cancer aggressiveness, and prediction of lymph node status.


Assuntos
Neoplasias da Mama , Fluordesoxiglucose F18 , Humanos , Feminino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia
12.
Diagnostics (Basel) ; 13(4)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36832242

RESUMO

There is limited information about whether the level of enhancement on contrast-enhanced mammography (CEM) can be used to predict malignancy. The purpose of this study was to correlate the level of enhancement with the presence of malignancy and breast cancer (BC) aggressiveness on CEM. This IRB-approved, cross-sectional, retrospective study included consecutive patients examined with CEM for unclear or suspicious findings on mammography or ultrasound. Excluded were examinations performed after biopsy or during neoadjuvant treatment for BC. Three breast radiologists who were blinded to patient data evaluated the images. The enhancement intensity was rated from 0 (no enhancement) to 3 (distinct enhancement). ROC analysis was performed. Sensitivity and negative likelihood ratio (LR-) were calculated after dichotomizing enhancement intensity as negative (0) versus positive (1-3). A total of 156 lesions (93 malignant, 63 benign) in 145 patients (mean age 59 ± 11.6 years) were included. The mean ROC curve was 0.827. Mean sensitivity was 95.4%. Mean LR- was 0.12%. Invasive cancer presented predominantly (61.8%) with distinct enhancement. A lack of enhancement was mainly observed for ductal carcinoma in situ. Stronger enhancement intensity was positively correlated with cancer aggressiveness, but the absence of enhancement should not be used to downgrade suspicious calcifications.

13.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
14.
Ultraschall Med ; 44(2): 162-168, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34425600

RESUMO

PURPOSE: In this prospective, multicenter trial we evaluated whether additional shear wave elastography (SWE) for patients with BI-RADS 3 or 4 lesions on breast ultrasound could further refine the assessment with B-mode breast ultrasound for breast cancer diagnosis. MATERIALS AND METHODS: We analyzed prospective, multicenter, international data from 1288 women with breast lesions rated by conventional 2 D B-mode ultrasound as BI-RADS 3 to 4c and undergoing 2D-SWE. After reclassification with SWE the proportion of undetected malignancies should be < 2 %. All patients underwent histopathologic evaluation (reference standard). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 lesions (28.6 %). The assessment with B-mode breast ultrasound resulted in 1.39 % (6 of 431) undetected malignancies (malignant lesions in BI-RADS 3) and 53.80 % (495 of 920) unnecessary biopsies (biopsies in benign lesions). Re-classifying BI-RADS 4a patients with a SWE cutoff of 2.55 m/s resulted in 1.98 % (11 of 556) undetected malignancies and a reduction of 24.24 % (375 vs. 495) of unnecessary biopsies. CONCLUSION: A SWE value below 2.55 m/s for BI-RADS 4a lesions could be used to downstage these lesions to follow-up, and therefore reduce the number of unnecessary biopsies by 24.24 %. However, this would come at the expense of some additionally missed cancers compared to B-mode breast ultrasound (rate of undetected malignancies 1.98 %, 11 of 556, versus 1.39 %, 6 of 431) which would, however, still be in line with the ACR BI-RADS 3 definition (< 2 % of undetected malignancies).


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos , Biópsia
15.
J Nucl Med ; 64(2): 304-311, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36137756

RESUMO

In addition to its high prognostic value, the involvement of axillary lymph nodes in breast cancer patients also plays an important role in therapy planning. Therefore, an imaging modality that can determine nodal status with high accuracy in patients with primary breast cancer is desirable. Our purpose was to investigate whether, in newly diagnosed breast cancer patients, machine-learning prediction models based on simple assessable imaging features on MRI or PET/MRI are able to determine nodal status with performance comparable to that of experienced radiologists; whether such models can be adjusted to achieve low rates of false-negatives such that invasive procedures might potentially be omitted; and whether a clinical framework for decision support based on simple imaging features can be derived from these models. Methods: Between August 2017 and September 2020, 303 participants from 3 centers prospectively underwent dedicated whole-body 18F-FDG PET/MRI. Imaging datasets were evaluated for axillary lymph node metastases based on morphologic and metabolic features. Predictive models were developed for MRI and PET/MRI separately using random forest classifiers on data from 2 centers and were tested on data from the third center. Results: The diagnostic accuracy for MRI features was 87.5% both for radiologists and for the machine-learning algorithm. For PET/MRI, the diagnostic accuracy was 89.3% for the radiologists and 91.2% for the machine-learning algorithm, with no significant differences in diagnostic performance between radiologists and the machine-learning algorithm for MRI (P = 0.671) or PET/MRI (P = 0.683). The most important lymph node feature was tracer uptake, followed by lymph node size. With an adjusted threshold, a sensitivity of 96.2% was achieved by the random forest classifier, whereas specificity, positive predictive value, negative predictive value, and accuracy were 68.2%, 78.1%, 93.8%, and 83.3%, respectively. A decision tree based on 3 simple imaging features could be established for MRI and PET/MRI. Conclusion: Applying a high-sensitivity threshold to the random forest results might potentially avoid invasive procedures such as sentinel lymph node biopsy in 68.2% of the patients.


Assuntos
Neoplasias da Mama , Sistemas de Apoio a Decisões Clínicas , Humanos , Feminino , Fluordesoxiglucose F18 , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Sensibilidade e Especificidade , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Compostos Radiofarmacêuticos
16.
Eur J Cancer ; 177: 1-14, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36283244

RESUMO

BACKGROUND: Breast ultrasound identifies additional carcinomas not detected in mammography but has a higher rate of false-positive findings. We evaluated whether use of intelligent multi-modal shear wave elastography (SWE) can reduce the number of unnecessary biopsies without impairing the breast cancer detection rate. METHODS: We trained, tested, and validated machine learning algorithms using SWE, clinical, and patient information to classify breast masses. We used data from 857 women who underwent B-mode breast ultrasound, SWE, and subsequent histopathologic evaluation at 12 study sites in seven countries from 2016 to 2019. Algorithms were trained and tested on data from 11 of the 12 sites and externally validated using the additional site's data. We compared findings to the histopathologic evaluation and compared the diagnostic performance between B-mode breast ultrasound, traditional SWE, and intelligent multi-modal SWE. RESULTS: In the external validation set (n = 285), intelligent multi-modal SWE showed a sensitivity of 100% (95% CI, 97.1-100%, 126 of 126), a specificity of 50.3% (95% CI, 42.3-58.3%, 80 of 159), and an area under the curve of 0.93 (95% CI, 0.90-0.96). Diagnostic performance was significantly higher compared to traditional SWE and B-mode breast ultrasound (P < 0.001). Unlike traditional SWE, positive-predictive values of intelligent multi-modal SWE were significantly higher compared to B-mode breast ultrasound. Unnecessary biopsies were reduced by 50.3% (79 versus 159, P < 0.001) without missing cancer compared to B-mode ultrasound. CONCLUSION: The majority of unnecessary breast biopsies might be safely avoided by using intelligent multi-modal SWE. These results may be helpful to reduce diagnostic burden for patients, providers, and healthcare systems.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Estudos Retrospectivos , Ultrassonografia Mamária , Biópsia , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Diagnóstico Diferencial
17.
Cancers (Basel) ; 14(16)2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36010936

RESUMO

PURPOSE: To investigate whether a machine learning (ML)-based radiomics model applied to 18F-FDG PET/MRI is effective in molecular subtyping of breast cancer (BC) and specifically in discriminating triple negative (TN) from other molecular subtypes of BC. METHODS: Eighty-six patients with 98 BC lesions (Luminal A = 10, Luminal B = 51, HER2+ = 12, TN = 25) were included and underwent simultaneous 18F-FDG PET/MRI of the breast. A 3D segmentation of BC lesion was performed on T2w, DCE, DWI and PET images. Quantitative diffusion and metabolic parameters were calculated and radiomics features extracted. Data were selected using the LASSO regression and used by a fine gaussian support vector machine (SVM) classifier with a 5-fold cross validation for identification of TNBC lesions. RESULTS: Eight radiomics models were built based on different combinations of quantitative parameters and/or radiomic features. The best performance (AUROC 0.887, accuracy 82.8%, sensitivity 79.7%, specificity 86%, PPV 85.3%, NPV 80.8%) was found for the model combining first order, neighborhood gray level dependence matrix and size zone matrix-based radiomics features extracted from ADC and PET images. CONCLUSION: A ML-based radiomics model applied to 18F-FDG PET/MRI is able to non-invasively discriminate TNBC lesions from other BC molecular subtypes with high accuracy. In a future perspective, a "virtual biopsy" might be performed with radiomics signatures.

18.
Eur Radiol ; 32(10): 6557-6564, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35852572

RESUMO

OBJECTIVES: Due to its high sensitivity, DCE MRI of the breast (MRIb) is increasingly used for both screening and assessment purposes. The Kaiser score (KS) is a clinical decision algorithm, which formalizes and guides diagnosis in breast MRI and is expected to compensate for lesser reader experience. The aim was to evaluate the diagnostic performance of untrained residents using the KS compared to off-site radiologists experienced in breast imaging using only MR BI-RADS. METHODS: Three off-site, board-certified radiologists, experienced in breast imaging, interpreted MRIb according to the MR BI-RADS scale. The same studies were read by three residents in radiology without prior training in breast imaging using the KS. All readers were blinded to clinical information. Histology was used as the gold standard. Statistical analysis was conducted by comparing the AUC of the ROC curves. RESULTS: A total of 80 women (median age 52 years) with 93 lesions (32 benign, 61 malignant) were included. The individual within-group performance of the three expert readers (AUC 0.723-0.742) as well as the three residents was equal (AUC 0.842-0.928), p > 0.05, respectively. But, the rating of each resident using the KS significantly outperformed the experts' ratings using the MR BI-RADS scale (p ≤ 0.05). CONCLUSION: The KS helped residents to achieve better results in reaching correct diagnoses than experienced radiologists empirically assigning MR BI-RADS categories in a clinical "problem solving MRI" setting. These results support that reporting breast MRI benefits more from using a diagnostic algorithm rather than expert experience. KEY POINTS: • Reporting breast MRI benefits more from using a diagnostic algorithm rather than expert experience in a clinical "problem solving MRI" setting. • The Kaiser score, which provides a clinical decision algorithm for structured reporting, helps residents to reach an expert level in breast MRI reporting and to even outperform experienced radiologists using MR BI-RADS without further formal guidance.


Assuntos
Neoplasias da Mama , Mama , Algoritmos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35175381

RESUMO

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Algoritmos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imagem Multimodal
20.
Eur J Cancer ; 161: 1-9, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34879299

RESUMO

BACKGROUND: Shear wave elastography (SWE) and strain elastography (SE) have shown promising potential in breast cancer diagnostics by evaluating the stiffness of a lesion. Combining these two techniques could further improve the diagnostic performance. We aimed to exploratorily define the cut-offs at which adding combined SWE and SE to B-mode breast ultrasound could help reclassify Breast Imaging Reporting and Data System (BI-RADS) 3-4 lesions to reduce the number of unnecessary breast biopsies. METHODS: We report the secondary results of a prospective, multicentre, international trial (NCT02638935). The trial enrolled 1288 women with BI-RADS 3 to 4c breast masses on conventional B-mode breast ultrasound. All patients underwent SWE and SE (index test) and histopathologic evaluation (reference standard). Reduction of unnecessary biopsies (biopsies in benign lesions) and missed malignancies after recategorising with SWE and SE were the outcome measures. RESULTS: On performing histopathologic evaluation, 368 of 1288 breast masses were malignant. Following the routine B-mode breast ultrasound assessment, 53.80% (495 of 920 patients) underwent an unnecessary biopsy. After recategorising BI-RADS 4a lesions (SWE cut-off ≥3.70 m/s, SE cut-off ≥1.0), 34.78% (320 of 920 patients) underwent an unnecessary biopsy corresponding to a 35.35% (320 versus 495) reduction of unnecessary biopsies. Malignancies in the new BI-RADS 3 cohort were missed in 1.96% (12 of 612 patients). CONCLUSION: Adding combined SWE and SE to routine B-mode breast ultrasound to recategorise BI-RADS 4a patients could help reduce the number of unnecessary biopsies in breast diagnostics by about 35% while keeping the rate of undetected malignancies below the 2% ACR BI-RADS 3 definition.


Assuntos
Biópsia/métodos , Neoplasias da Mama/diagnóstico , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...