Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Intensive Care Med Exp ; 9(1): 8, 2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33728866

RESUMO

BACKGROUND: Inspired air is heated and humidified in the nose before it reaches lower airways. This mechanism is bypassed during tracheostomy, directly exposing the airways to colder and drier air from the environment, known to negatively affect mucociliary transport; however, little is known about how quickly mucociliary transport deteriorates. This study determines the short-term effect of flowing room air and nebulized hypertonic saline and mannitol on mucociliary transport in the trachea. In an ovine perfused in vitro tracheal model (N = 9) the epithelium was exposed to 25 L/min of flow, heated to lamb body temperature (38 °C) and fully saturated with water vapor as the control, followed by either room air (22 °C and 50% relative humidity) or nebulized solutions of NaCl 7% and mannitol 20% up to 1 min for a short duration, until mucociliary transport had visually changed. Mucus transport velocity (MTV) and cilia beat frequency (CBF) were continuously measured with video-microscopy. RESULTS: Exposing the tracheal epithelium to air heated to body temperature and fully humidified had stable MTV 9.5 ± 1.1 mm/min and CBF 13.4 ± 0.6 Hz. When exposed to flow of room air, MTV slowed down to 0.1 ± 0.1 mm/min in 2.0 ± 0.4 s followed by a decrease in CBF to 6.7 ± 1.9 Hz, after 2.3 ± 0.8 s. Both MTV and CBF recovered to their initial state when heated and humidified air-flow was re-introduced. Exposing the tracheal epithelium to nebulized hypertonic saline and nebulized mannitol for 1 min increased MTV without a subsequent increase in CBF. CONCLUSIONS: This study demonstrates mucociliary transport can deteriorate within seconds of exposing the tracheal epithelium to flowing room air and increase rapidly when exposed to nebulized hypertonic solutions. The reduction in MTV precedes slowing of CBF with room air and MTV increases without a subsequent increase in CBF during the nebulization. Their relationship is non-linear and a minimum CBF of approximately 6 Hz is required for MTV > 0, while MTV can reach 10.9 mm/min without CBF increasing. Clinically these findings indicate a potential rapid detrimental effect of breathing with non-humidified air via bypassed upper airways and the short-term effects of nebulized osmotic agents that increase MTV.

2.
BMC Res Notes ; 14(1): 78, 2021 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-33640024

RESUMO

OBJECTIVE: Small angle X-ray scattering (SAXS) analysis is a sensitive way of determining the ultrastructure of collagen in tissues. Little is known about how parameters measured by SAXS are affected by preservatives commonly used to prevent autolysis. We determined the effects of formalin, glutaraldehyde, Triton X and saline on measurements of fibril diameter, fibril diameter distribution, and D-spacing of corneal collagen using SAXS analysis. RESULTS: Compared to sections of sheep and cats' corneas stored frozen as controls, those preserved in 5% glutaraldehyde and 10% formalin had significantly larger mean collagen fibril diameters, increased fibril diameter distribution and decreased D-spacing. Sections of corneas preserved in Triton X had significantly increased collagen fibril diameters and decreased fibril diameter distribution. Those preserved in 0.9% saline had significantly increased mean collagen fibril diameters and decreased diameter distributions. Subjectively, the corneas preserved in 5% glutaraldehyde and 10% formalin maintained their transparency but those in Triton X and 0.9% saline became opaque. Subjective morphological assessment of transmission electron microscope images of corneas supported the SAXS data. Workers using SAXS analysis to characterize collagen should be alerted to changes that can be introduced by common preservatives in which their samples may have been stored.


Assuntos
Colágeno , Córnea , Animais , Gatos , Projetos Piloto , Espalhamento a Baixo Ângulo , Ovinos , Difração de Raios X , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...