Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Eur J Pharm Sci ; 197: 106773, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38641124

RESUMO

Cytochrome P450 (CYP) system is a critical elimination route to most pharmaceuticals in human, but also prone to drug-drug interactions arising from the fact that concomitantly administered pharmaceuticals inhibit one another's CYP metabolism. The most severe form of CYP interactions is irreversible inhibition, which results in permanent inactivation of the critical CYP pathway and is only restored by de novo synthesis of new functional enzymes. In this study, we conceptualize a microfluidic approach to mechanistic CYP inhibition studies using human liver microsomes (HLMs) immobilized onto the walls of a polymer micropillar array. We evaluated the feasibility of these HLM chips for CYP inhibition studies by establishing the stability and the enzyme kinetics for a CYP2C9 model reaction under microfluidic flow and determining the half-maximal inhibitory concentrations (IC50) of three human CYP2C9 inhibitors (sulfaphenazole, tienilic acid, miconazole), including evaluation of their inhibition mechanisms and nonspecific microsomal binding on chip. Overall, the enzyme kinetics of CYP2C9 metabolism on the HLM chip (KM = 127 ± 55 µM) was shown to be similar to that of static HLM incubations (KM = 114 ± 14 µM) and the IC50 values toward CYP2C9 derived from the microfluidic assays (sulfaphenazole 0.38 ± 0.09 µM, tienilic acid 3.4 ± 0.6 µM, miconazole 0.54 ± 0.09 µM) correlated well with those determined using current standard IC50 shift assays. Most importantly, the HLM chip could distinguish between reversible (sulfaphenazole) and irreversible (tienilic acid) enzyme inhibitors in a single, automated experiment, indicating the great potential of the HLM chip to simplify current workflows used in mechanistic CYP inhibition studies. Furthermore, the results suggest that the HLM chip can also identify irreversible enzyme inhibitors, which are not necessarily resulting in a time-dependent inhibition (like suicide inhibitors), but whose inhibition mechanism is based on other kind of covalent or irreversible interaction with the CYP system. With our HLM chip approach, we could identify miconazole as such a compound that nonselectively inhibits the human CYP system with a prolonged, possibly irreversible impact in vitro, even if it is not a time-dependent inhibitor according to the IC50 shift assay.


Assuntos
Microssomos Hepáticos , Humanos , Microssomos Hepáticos/metabolismo , Citocromo P-450 CYP2C9/metabolismo , Cinética , Inibidores das Enzimas do Citocromo P-450/farmacologia , Miconazol/farmacologia , Enzimas Imobilizadas/metabolismo , Inibidores do Citocromo P-450 CYP2C9/farmacologia , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/métodos , Sulfafenazol/farmacologia , Microfluídica/métodos
2.
J Mater Chem C Mater ; 10(12): 4871-4877, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35433006

RESUMO

The full potential of triplet fusion photon upconversion (TF-UC) of providing high-energy photons locally with low-energy excitation is limited in biomedicine and life sciences by its oxygen sensitivity. This hampers the applicability of TF-UC systems in sensors, imaging, optogenetics and drug release. Despite the advances in improving the oxygen tolerability of TF-UC systems, the evaluation of oxygen tolerability is based on comparing the performance at completely deoxygenated (0% oxygen) and ambient (20-21%) conditions, leaving the physiological oxygen levels (0.3-13.5%) neglected. This oversight is not deliberate and is only the result of the lack of simple and predictable methods to obtain and maintain these physiological oxygen levels in an optical setup. Herein, we demonstrate the use of microfluidic chips made of oxygen depleting materials to study the oxygen tolerability of four different micellar nanocarriers made of FDA-approved materials with various oxygen scavenging capabilities by screening their TF-UC performance over physiological oxygen levels. All nanocarriers were capable of efficient TF-UC even in ambient conditions. However, utilizing oxygen scavengers in the oil phase of the nanocarrier improves the oxygen tolerability considerably. For example, at the mean tumour oxygen level (1.4%), nanocarriers made of surfactants and oil phase both capable of oxygen scavenging retained remarkably 80% of their TF-UC emission. This microfluidic concept enables faster, simpler and more realistic evaluation of, not only TF-UC, but any micro or nanoscale oxygen-sensitive system and facilitates their development and implementation in biomedical and life science applications.

3.
Lab Chip ; 21(9): 1820-1831, 2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33949410

RESUMO

Tissue oxygen levels are known to be critical to regulation of many cellular processes, including the hepatic metabolism of therapeutic drugs, but its impact is often ignored in in vitro assays. In this study, the material-induced oxygen scavenging property of off-stoichiometric thiol-enes (OSTE) was exploited to create physiologically relevant oxygen concentrations in microfluidic immobilized enzyme reactors (IMERs) incorporating human liver microsomes. This could facilitate rapid screening of, for instance, toxic drug metabolites possibly produced in hypoxic conditions typical for many liver injuries. The mechanism of OSTE-induced oxygen scavenging was examined in depth to enable precise adjustment of the on-chip oxygen concentration with the help of microfluidic flow. The oxygen scavenging rate of OSTE was shown to depend on the type and the amount of the thiol monomer used in the bulk composition, and the surface-to-volume ratio of the chip design, but not on the physical or mechanical properties of the bulk. Our data suggest that oxygen scavenging takes place at the polymer-liquid interface, likely via oxidative reactions of the excess thiol monomers released from the bulk with molecular oxygen. Based on the kinetic constants governing the oxygen scavenging rate in OSTE microchannels, a microfluidic device comprising monolithically integrated oxygen depletion and IMER units was designed and its performance validated with the help of oxygen-dependent metabolism of an antiretroviral drug, zidovudine, which yields a cytotoxic metabolite under hypoxic conditions.


Assuntos
Microfluídica , Preparações Farmacêuticas , Estudos de Viabilidade , Humanos , Hipóxia , Oxigênio , Compostos de Sulfidrila
4.
Eur J Pharm Sci ; 158: 105677, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33309889

RESUMO

UDP-glucuronosyltransferases (UGTs), located in the endoplasmic reticulum of liver cells, are an important family of enzymes, responsible for the biotransformation of several endogenous and exogenous chemicals, including therapeutic drugs. However, the phenomenon of 'latency', i.e., full UGT activity revealed by disruption of the microsomal membrane, poses substantial challenges for predicting drug clearance based on in vitro glucuronidation assays. This work introduces a microfluidic reactor design comprising immobilized human liver microsomes to facilitate the study of UGT-mediated drug clearance under flow-through conditions. The performance of the microreactor is characterized using glucuronidation of 8-hydroxyquinoline (via multiple UGTs) and zidovudine (via UGT2B7) as the model reactions. With the help of alamethicin and albumin effects, we show that conducting UGT metabolism assays under flow conditions facilitates in-depth mechanistic studies, which may also shed light on UGT latency.


Assuntos
Microssomos Hepáticos , Preparações Farmacêuticas , Glucuronídeos , Glucuronosiltransferase , Humanos , Microfluídica , Microssomos
5.
Adv Biosyst ; 3(1): e1800245, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32627340

RESUMO

This work describes a new nanotechnology-based immobilization strategy for cytochrome P450s (CYPs), the major class of drug metabolizing enzymes. Immobilization of CYPs on solid supports provides a significant leap forward compared with soluble enzyme assays by enabling the implementation of through-flow microreactors for, for example, determination of time-dependent inhibition. Immobilization of the complex CYP membrane-protein system is however particularly challenging as the preservation of the authentic enzyme kinetic parameters requires the full complexity of the lipid environment. The developed strategy is based on the spontaneous fusion of biotinylated fusogenic liposomes with lipid bilayers to facilitate the gentle biotinylation of human liver microsomes that incorporate all main natural CYP isoforms. The same process is also feasible for the biotinylation of recombinant CYPs expressed in insect cells, same as any membrane-bound enzymes in principle. As a result, CYPs could be immobilized on streptavidin-functionalized surfaces, both those of commercial magnetic beads and customized microfluidic arrays, so that the enzyme kinetic parameters remain unchanged, unlike in previously reported immobilization approaches that often suffer from restricted substrate diffusion to the enzyme's active site and steric hindrances. The specificity and robustness of the functionalization method of customized microfluidic CYP assays are also carefully examined.

6.
Anal Bioanal Chem ; 410(25): 6677-6687, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30073515

RESUMO

We report the development and characterization of digital microfluidic (DMF) immobilized enzyme reactors (IMERs) for studying cytochrome P450 (CYP)-mediated drug metabolism on droplet scale. The on-chip IMERs consist of porous polymer (thiol-ene) monolith plugs prepared in situ by photopolymerization and functionalized with recombinant CYP1A1 isoforms (an important detoxification route for many drugs and other xenobiotics). The DMF devices also incorporate inexpensive, inkjet-printed microheaters for on-demand regio-specific heating of the IMERs to physiological temperature, which is crucial for maintaining the activity of the temperature-sensitive CYP reaction. For on-chip monitoring of the CYP activity, the DMF devices were combined with a commercial well-plate reader, and a custom fluorescence quantification method was developed for detection of the chosen CYP1A1 model activity (ethoxyresorufin-O-deethylation). The reproducibility of the developed assay was examined with the help of ten parallel CYP-IMERs. All CYP-IMERs provided statistically significant difference (in fluorescence response) compared to any of the negative controls (including room-temperature reactions). The average (n = 10) turnover rate was 20.3 ± 9.0 fmol resorufin per minute. Via parallelization, the concept of the droplet-based CYP-IMER developed in this study provides a viable approach to rapid and low-cost prediction of the metabolic clearance of new chemical entities in vitro.


Assuntos
Sistema Enzimático do Citocromo P-450/química , Dispositivos Lab-On-A-Chip , Microfluídica , Impressão , Reprodutibilidade dos Testes
7.
Pharmaceutics ; 11(1)2018 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-30598037

RESUMO

Biologicals are important ocular drugs that are be delivered using monthly and bimonthly intravitreal injections to treat retinal diseases, such as age-related macular degeneration. Long acting delivery systems are needed for prolongation of their dosing interval. Intravitreal biologicals are eliminated from the eye via the aqueous humor outflow. Thus, the anterior and posterior segments are exposed to the drug. We utilized a kinetic simulation model to estimate protein drug concentrations in the vitreous and aqueous humor after bolus injection and controlled release administration to the vitreous. The simulations predicted accurately the experimental levels of 5 biologicals in the vitreous and aqueous humor. The good match between the simulations and experimental data demonstrated almost complete anterior segment bioavailability, and major dose sparing with ocular controlled release systems. Overall, the model is a useful tool in the design of intraocular delivery of biologicals.

8.
Rapid Commun Mass Spectrom ; 29(5): 424-30, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26349464

RESUMO

RATIONALE: Neonicotinoids are widely used insecticides which have been shown to affect the memory and learning abilities of honey bees, and are suspected to play a part in the unexplainable, large-scale loss of honey bee colonies. Fast methods, such as ambient mass spectrometry (MS), for their analysis from a variety of matrices are necessary to control the use of forbidden products and study the spreading of insecticides in nature. METHODS: The feasibilities of two ambient MS methods, desorption electrospray ionization (DESI) and desorption atmospheric pressure photoionization (DAPPI), for the analysis of five most used neonicotinoid compounds, thiacloprid, acetamiprid, clothianidin, imidacloprid and thiamethoxam, were tested. In addition, DAPPI was used to analyze fresh rose leaves treated with commercially available thiacloprid insecticide and dried and powdered turnip rape flowers, which had been collected from a field treated with thiacloprid-containing insecticide. RESULTS: DAPPI was found to be more sensitive than DESI, with 2-11 times better signal-to-noise ratios, and limits of detection at 0.4-5.0 fmol for the standard compounds. DAPPI was able to detect thiacloprid from the rose leaves even 2.5 months after the treatment and from the turnip rape flower samples collected from a field. The analysis of plant material by DAPPI did not require extraction or other sample preparation. CONCLUSIONS: DAPPI was found to be suitable for the fast and direct qualitative analysis of thiacloprid neonicotinoid from plant samples. It shows promise as a fast tool for screening of forbidden insecticides, or studying the distribution of insecticides in nature.


Assuntos
Flores/química , Inseticidas/análise , Folhas de Planta/química , Piridinas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Compostos de Enxofre/análise , Brassica napus/química , Limite de Detecção , Rosa/química
9.
Rapid Commun Mass Spectrom ; 29(7): 585-92, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-26212275

RESUMO

RATIONALE: Desorption atmospheric pressure photoionization (DAPPI) is an ambient mass spectrometry (MS) technique that is suitable for the direct analysis of polar and nonpolar compounds from a variety of surfaces. Conventional DAPPI uses reflection geometry, but here transmission mode (TM)-DAPPI is introduced for fast and easy analysis of liquid samples. METHODS: Stainless steel and PEEK meshes were used as sampling support in TM-DAPPI. The sample was applied either in the form of a droplet on the mesh, or by dipping the mesh in the sample solution. Physical parameters affecting the ionization efficiency were optimized for TM-DAPPI. The mesh materials were used to extract compounds from aqueous samples, which were then analyzed by TM-DAPPI. TM-DAPPI and conventional DAPPI were compared. RESULTS: In TM-DAPPI, intense signals for the analytes were achieved with less heating power, and lower nebulizer gas and dopant flow rates than optimally used in conventional DAPPI. Either due to this, or the different sample support material used, a much lower background and improved sensitivity compared to conventional DAPPI was achieved. The analytes could be extracted and concentrated from liquid samples on the mesh material used in TM-DAPPI, which was especially efficient for the nonpolar benzo[a]pyrene. This effect was utilized in the analysis of triacylglycerols from cow milk. CONCLUSIONS: While conventional DAPPI is still the method of choice for solid samples, TM-DAPPI can be utilized as a fast, easily automated method for analyzing liquid samples. The mesh materials can be utilized for extraction of low polarity compounds, such as steroid hormones or PAHs from dilute, aqueous solutions, followed by subsequent analysis by TM-DAPPI.


Assuntos
Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Animais , Pressão Atmosférica , Benzo(a)pireno/análise , Benzo(a)pireno/química , Benzofenonas , Bovinos , Cetonas , Procedimentos Analíticos em Microchip , Leite/química , Polietilenoglicóis , Polímeros , Aço Inoxidável , Tolueno/química , Triglicerídeos/análise , Triglicerídeos/química
10.
Anal Chem ; 87(6): 3280-5, 2015 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-25715054

RESUMO

A new ambient mass spectrometry method, solvent jet desorption capillary photoionization (DCPI), is described. The method uses a solvent jet generated by a coaxial nebulizer operated at ambient conditions with nitrogen as nebulizer gas. The solvent jet is directed onto a sample surface, from which analytes are extracted into the solvent and ejected from the surface in secondary droplets formed in collisions between the jet and the sample surface. The secondary droplets are directed into the heated capillary photoionization (CPI) device, where the droplets are vaporized and the gaseous analytes are ionized by 10 eV photons generated by a vacuum ultraviolet (VUV) krypton discharge lamp. As the CPI device is directly connected to the extended capillary inlet of the MS, high ion transfer efficiency to the vacuum of MS is achieved. The solvent jet DCPI provides several advantages: high sensitivity for nonpolar and polar compounds with limit of detection down to low fmol levels, capability of analyzing small and large molecules, and good spatial resolution (250 µm). Two ionization mechanisms are involved in DCPI: atmospheric pressure photoionization, capable of ionizing polar and nonpolar compounds, and solvent assisted inlet ionization capable of ionizing larger molecules like peptides. The feasibility of DCPI was successfully tested in the analysis of polar and nonpolar compounds in sage leaves and chili pepper.


Assuntos
Espectrometria de Massas/métodos , Solventes/química , Capsicum/química , Estudos de Viabilidade , Espectrometria de Massas/instrumentação , Nebulizadores e Vaporizadores , Salvia officinalis/química , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...