Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; PP2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39102317

RESUMO

BACKGROUND: Handheld laser speckle contrast imaging (LSCI) is crucial in clinical settings, but motion artifacts (MA) can compromise perfusion image reliability. Current prevention and suppression methods are often impractical or complex. Machine vision techniques, promising in medical imaging, could improve signal quality, but their use in suppressing MA is still unexplored. OBJECTIVE: We propose an innovative method based on linear regression for MA correction (MAC) in LSCI and validate it in vivo. METHODS: We performed paired handheld and mounted LSCI measurements on 14 subjects with psoriasis using the previously validated handheld perfusion imager (HAPI). By marking lesion boundaries for clinical purposes, the HAPI used a monochromatic camera for both speckle imaging and motion detection, simplifying hardware requirements. Accurate estimation of relative displacements between the test object and LSCI probe allowed us to apply MAC to the perfusion images. RESULTS: Local perfusion values correlated with applied speed were used to calculate and correct MA. The difference between mean perfusion in handheld and mounted modes after MAC significantly decreased (median error 14.2 perfusion units (p.u.) on lesions before correction ( ) and 0.5 p.u. after correction ( p=0.2)). CONCLUSION: The findings provide evidence for robust handheld LSCI and validate the MA technique in psoriasis case. Of the two causes of MA-onsurface speeds and wavefront tilt-we address the former and correct mean perfusion, assuming constant temporal perfusion at each location. SIGNIFICANCE: We describe a practical, non-contact, marker-free technique for reliable handheld perfusion imaging, supporting further clinical translation in plastic surgery and burns.

2.
Biomed Opt Express ; 14(9): 4485-4506, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37791261

RESUMO

We propose a new, user-friendly and accessible approach for fabricating thin phantoms with controllable absorption properties in magnitude, spectral shape, and spatial distribution. We utilize a standard office laser color printer to print on polyurethane thin films (40 - 60 µm), commonly available as medical film dressings and ultrasound probe covers. We demonstrate that the optical attenuation and absorption of the printed films correlate linearly with the printer input settings (opacity), which facilitates a systematic phantom design. The optical and acoustic properties of these polyurethane films are similar to biological tissue. We argue that these thin phantoms are applicable to a wide range of biomedical applications. Here, we introduce two potential applications: (1) homogeneous epidermal melanin phantoms and (2) spatially resolved absorbers for photoacoustic imaging. We characterize the thin phantoms in terms of optical properties, thickness, microscopic structure, and reproducibility of the printing process.

3.
J Biomed Opt ; 28(4): 046005, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37082096

RESUMO

Significance: In handheld laser speckle contrast imaging (LSCI), motion artifacts (MA) are inevitable. Suppression of MA leads to a valid and objective assessment of tissue perfusion in a wide range of medical applications including dermatology and burns. Our study shines light on the sources of these artifacts, which have not yet been explored. We propose a model based on optical Doppler effect to predict speckle contrast drop as an indication of MA. Aim: We aim to theoretically model MA when an LSCI system measuring on static scattering media is subject to translational displacements. We validate the model using both simulation and experiments. This is the crucial first step toward creating robustness against MA. Approach: Our model calculates optical Doppler shifts in order to predict intensity correlation function and contrast of the time-integrated intensity as functions of applied speed based on illumination and detection wavevectors. To validate the theoretical predictions, computer simulation of the dynamic speckles has been carried out. Then experiments are performed by both high-speed and low-framerate imaging. The employed samples for the experiments are a highly scattering matte surface and a Delrin plate of finite scattering level in which volume scattering occurs. Results: An agreement has been found between theoretical prediction, simulation, and experimental results of both intensity correlation functions and speckle contrast. Coefficients in the proposed model have been linked to the physical parameters according to the experimental setups. Conclusions: The proposed model provides a quantitative description of the influence of the types of illumination and media in the creation of MA. The accurate prediction of MA caused by translation based on Doppler shifts makes our model suitable to study the influence of rotation. Also the model can be extended for the case of dynamic media, such as live tissue.


Assuntos
Artefatos , Imagem de Contraste de Manchas a Laser , Simulação por Computador , Diagnóstico por Imagem , Ultrassonografia Doppler , Fluxometria por Laser-Doppler/métodos , Fluxo Sanguíneo Regional
4.
Skin Res Technol ; 28(1): 104-110, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34619003

RESUMO

BACKGROUND: Skin microvasculature changes are crucial in psoriasis development and correlate with perfusion. The noninvasive Handheld Perfusion Imager (HAPI) examines microvascular skin perfusion in large body areas using laser speckle contrast imaging (LSCI). OBJECTIVES: To (i) assess whether increased perilesional perfusion and perfusion inhomogeneity are predictors for expansion of psoriasis lesions and (ii) assess feasibility of the HAPI system in a mounted modality. METHODS: In this interventional pilot study in adults with unstable plaque psoriasis, HAPI measurements and color photographs were performed for lesions present on one body region at week 0, 2, 4, 6 and 8. The presence of increased perilesional perfusion and perfusion inhomogeneity was determined. Clinical outcome was categorized as increased, stable or decreased lesion surface between visits. Patient feedback was collected on a 10-point scale. RESULTS: In total, 110 lesions with a median follow-up of 6 (IQR 6.0) weeks were assessed in 6 patients with unstable plaque psoriasis. Perfusion data was matched to 281 clinical outcomes after two weeks. A mixed multinomial logistic regression model revealed a predictive value of perilesional increased perfusion (OR 9.90; p < 0.001) and perfusion inhomogeneity (OR 2.39; p = 0.027) on lesion expansion after two weeks compared to lesion stability. HAPI measurements were considered fast, patient-friendly and important by patients. CONCLUSION: Visualization of increased perilesional perfusion and perfusion inhomogeneity by noninvasive whole field LSCI holds potential for prediction of psoriatic lesion expansion. Furthermore, the HAPI is a feasible and patient-friendly tool.


Assuntos
Imagem de Contraste de Manchas a Laser , Psoríase , Adulto , Humanos , Fluxometria por Laser-Doppler , Microcirculação , Perfusão , Imagem de Perfusão , Projetos Piloto , Psoríase/diagnóstico por imagem , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
5.
Sci Rep ; 11(1): 18251, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-34521868

RESUMO

Fluid flow shear stresses are strong regulators for directing the organization of vascular networks. Knowledge of structural and flow dynamics information within complex vasculature is essential for tuning the vascular organization within engineered tissues, by manipulating flows. However, reported investigations of vascular organization and their associated flow dynamics within complex vasculature over time are limited, due to limitations in the available physiological pre-clinical models, and the optical inaccessibility and aseptic nature of these models. Here, we developed laser speckle contrast imaging (LSCI) and side-stream dark field microscopy (SDF) systems to map the vascular organization, spatio-temporal blood flow fluctuations as well as erythrocytes movements within individual blood vessels of developing chick embryo, cultured within an artificial eggshell system. By combining imaging data and computational simulations, we estimated fluid flow shear stresses within multiscale vasculature of varying complexity. Furthermore, we demonstrated the LSCI compatibility with bioengineered perfusable muscle tissue constructs, fabricated via molding techniques. The presented application of LSCI and SDF on perfusable tissues enables us to study the flow perfusion effects in a non-invasive fashion. The gained knowledge can help to use fluid perfusion in order to tune and control multiscale vascular organization within engineered tissues.


Assuntos
Circulação Sanguínea , Vasos Sanguíneos/fisiologia , Imagem Óptica/métodos , Engenharia Tecidual/métodos , Animais , Vasos Sanguíneos/diagnóstico por imagem , Vasos Sanguíneos/crescimento & desenvolvimento , Embrião de Galinha , Eritrócitos/fisiologia , Imagem Multimodal/métodos , Músculos/irrigação sanguínea , Músculos/diagnóstico por imagem , Neovascularização Fisiológica
6.
Sci Rep ; 11(1): 16646, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34404886

RESUMO

Enabling handheld perfusion imaging would drastically improve the feasibility of perfusion imaging in clinical practice. Therefore, we examine the performance of handheld laser speckle contrast imaging (LSCI) measurements compared to mounted measurements, demonstrated in psoriatic skin. A pipeline is introduced to process, analyze and compare data of 11 measurement pairs (mounted-handheld LSCI modes) operated on 5 patients and various skin locations. The on-surface speeds (i.e. speed of light beam movements on the surface) are quantified employing mean separation (MS) segmentation and enhanced correlation coefficient maximization (ECC). The average on-surface speeds are found to be 8.5 times greater in handheld mode compared to mounted mode. Frame alignment sharpens temporally averaged perfusion maps, especially in the handheld case. The results show that after proper post-processing, the handheld measurements are in agreement with the corresponding mounted measurements on a visual basis. The absolute movement-induced difference between mounted-handheld pairs after the background correction is [Formula: see text] (mean ± std, [Formula: see text]), with an absolute median difference of [Formula: see text]. Realization of handheld LSCI facilitates measurements on a wide range of skin areas bringing more convenience for both patients and medical staff.


Assuntos
Desenho de Equipamento , Imagem de Perfusão/métodos , Psoríase/diagnóstico por imagem , Feminino , Humanos , Lasers , Masculino , Psoríase/patologia , Reprodutibilidade dos Testes
7.
Opt Lett ; 45(18): 5101-5104, 2020 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-32932463

RESUMO

Wavefront shaping is increasingly being used in modern microscopy to obtain high-resolution images deep inside inhomogeneous media. Wavefront shaping methods typically rely on the presence of a "guide star" to find the optimal wavefront to mitigate the scattering of light. However, the use of guide stars poses severe limitations. Notably, only objects in the close vicinity of the guide star can be imaged. Here, we introduce a guide-star-free wavefront shaping method in which the optimal wavefront is computed using a digital model of the sample. The refractive index model of the sample, that serves as the input for the computation, is constructed in situ by the microscope itself. In a proof of principle imaging experiment, we demonstrate a large improvement in the two-photon fluorescence signal through a diffuse medium, outperforming state-of-the-art wavefront shaping by a factor of two in imaging depth.

8.
Biomed Opt Express ; 11(5): 2352-2365, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32499928

RESUMO

Functional performance of handheld laser speckle contrast imaging (LSCI) is compromised by movement artefacts. Here we quantify the movements of a handheld LSCI system employing electromagnetic (EM) tracking and measure the applied translational, tilt and on-surface laser beam speeds. By observing speckle contrast on static objects, the magnitudes of translation and tilt of wavefronts are explored for various scattering levels of the objects. We conclude that for tissue mimicking static phantoms, on-surface speeds play a dominant role to wavefront tilt speed in creation of movement artefacts. The ratio depends on the optical properties of the phantom. Furthermore, with the same applied speed, the drop in the speckle contrast increases with decreasing reduced scattering coefficient, and hence the related movement artefact increases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...