Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 11360, 2021 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-34059754

RESUMO

A key predictor of morbidity and mortality for patients with a bloodstream infection is time to appropriate antimicrobial therapy. Accelerating antimicrobial susceptibility testing from positive blood cultures is therefore key to improving patient outcomes, yet traditional laboratory approaches can require 2-4 days for actionable results. The eQUANT-a novel instrument utilizing electrical biosensors-produces a standardized inoculum equivalent to a 0.5 McFarland directly from positive blood cultures. This proof-of-concept study demonstrates that eQUANT inocula prepared from clinically significant species of Enterobacterales were comparable to 0.5 McF inocula generated from bacterial colonies in both CFU/ml concentration and performance in antimicrobial susceptibility testing, with ≥ 95% essential and categorical agreement for VITEK2 and disk diffusion. The eQUANT, combined with a rapid, direct from positive blood culture identification technique, can allow the clinical laboratory to begin antimicrobial susceptibility testing using a standardized inoculum approximately 2-3 h after a blood culture flags positive. This has the potential to improve clinical practice by accelerating conventional antimicrobial susceptibility testing and the resulting targeted antibiotic therapy.


Assuntos
Eletrônica , Testes de Sensibilidade Microbiana/métodos , Algoritmos , Automação , Técnicas Biossensoriais , Contagem de Colônia Microbiana , Estudos de Avaliação como Assunto , Estudos de Viabilidade , Testes de Sensibilidade Microbiana/normas , Estudo de Prova de Conceito
2.
Adv Mater ; 26(35): 6138-44, 2014 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-25047764

RESUMO

Organic field-effect transistor (OFET) sensors can meet the need for portable and real-time diagnostics. An electronicreadout enzyme-linked immunosorbent assay using OFETs for the detection of a panel of three biomarkers in complex media to create a pre-eclampsia prognostic is demonstrated, along with biodetection utilizing a fully inkjet-printed and flexible OFET to underscore our ability to produce disposable devices.


Assuntos
Pré-Eclâmpsia/diagnóstico , Transistores Eletrônicos , Anticorpos/imunologia , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Feminino , Glucose Oxidase/química , Glucose Oxidase/metabolismo , Humanos , Pré-Eclâmpsia/metabolismo , Gravidez , Prognóstico , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/sangue , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/imunologia
3.
Nat Commun ; 5: 2954, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24389531

RESUMO

In recent decades, the susceptibility to degradation in both ambient and aqueous environments has prevented organic electronics from gaining rapid traction for sensing applications. Here we report an organic field-effect transistor sensor that overcomes this barrier using a solution-processable isoindigo-based polymer semiconductor. More importantly, these organic field-effect transistor sensors are stable in both freshwater and seawater environments over extended periods of time. The organic field-effect transistor sensors are further capable of selectively sensing heavy-metal ions in seawater. This discovery has potential for inexpensive, ink-jet printed, and large-scale environmental monitoring devices that can be deployed in areas once thought of as beyond the scope of organic materials.


Assuntos
Técnicas Biossensoriais/instrumentação , Água Doce/química , Íons/análise , Metais Pesados/análise , Polímeros , Água do Mar/química , Transistores Eletrônicos , Desenho de Equipamento , Semicondutores , Soluções
4.
ACS Nano ; 7(5): 3970-80, 2013 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-23597051

RESUMO

Biodetection using organic field-effect transistors (OFETs) is gaining increasing interest for applications as diverse as food security, environmental monitoring, and medical diagnostics. However, there still lacks a comprehensive, empirical study on the fundamental limits of OFET sensors. In this paper, we present a thorough study of the various parameters affecting biosensing using an OFET decorated with gold nanoparticle (AuNP) binding sites. These parameters include the spacing between receptors, pH of the buffer, and ionic strength of the buffer. To this end, we employed the thrombin protein and its corresponding DNA binding aptamer to form our model detection system. We demonstrate a detection limit of 100 pM for this protein with high selectivity over other proteases in situ. We describe herein a feasible approach for protein detection with OFETs and a thorough investigation of parameters governing biodetection events using OFETs. Our obtained results should provide important guidelines to tailor the sensor's dynamic range to suit other desired OFET-based biodetection applications.


Assuntos
Nanotecnologia/instrumentação , Compostos Orgânicos/química , Trombina/metabolismo , Transistores Eletrônicos , Aptâmeros de Nucleotídeos/genética , Aptâmeros de Nucleotídeos/metabolismo , Sequência de Bases , Ouro/química , Humanos , Nanopartículas Metálicas/química , Modelos Moleculares , Concentração Osmolar , Conformação Proteica , Reprodutibilidade dos Testes , Trombina/química
5.
ACS Nano ; 6(10): 9291-8, 2012 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-23016890

RESUMO

Silicon nanowire field-effect transistors have attracted substantial interest for various biochemical sensing applications, yet there remains uncertainty concerning their response to changes in the supporting electrolyte concentration. In this study, we use silicon nanowires coated with highly pH-sensitive hafnium oxide (HfO(2)) and aluminum oxide (Al(2)O(3)) to determine their response to variations in KCl concentration at several constant pH values. We observe a nonlinear sensor response as a function of ionic strength, which is independent of the pH value. Our results suggest that the signal is caused by the adsorption of anions (Cl(-)) rather than cations (K(+)) on both oxide surfaces. By comparing the data to three well-established models, we have found that none of those can explain the present data set. Finally, we propose a new model which gives excellent quantitative agreement with the data.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletrólitos/química , Nanopartículas Metálicas/química , Modelos Químicos , Silício/química , Transistores Eletrônicos , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Nanopartículas Metálicas/ultraestrutura
7.
Nano Lett ; 11(9): 3597-600, 2011 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-21766793

RESUMO

We observe very small gate-voltage shifts in the transfer characteristic of as-prepared graphene field-effect transistors (GFETs) when the pH of the buffer is changed. This observation is in strong contrast to Si-based ion-sensitive FETs. The low gate-shift of a GFET can be further reduced if the graphene surface is covered with a hydrophobic fluorobenzene layer. If a thin Al-oxide layer is applied instead, the opposite happens. This suggests that clean graphene does not sense the chemical potential of protons. A GFET can therefore be used as a reference electrode in an aqueous electrolyte. Our finding sheds light on the large variety of pH-induced gate shifts that have been published for GFETs in the recent literature.


Assuntos
Técnicas Biossensoriais/métodos , Grafite/química , Nanotecnologia/métodos , Óxido de Alumínio/química , Soluções Tampão , Cobre/química , Eletroquímica/métodos , Eletrodos , Fluorbenzenos/química , Concentração de Íons de Hidrogênio , Íons , Nanopartículas/química , Óptica e Fotônica/métodos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...