Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Orthod Craniofac Res ; 20(4): 202-208, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28857415

RESUMO

OBJECTIVES: To determine differences in arch forms derived from the root apices locations between individuals with <2 mm maxillary crowding and controls. SETTING AND SAMPLE POPULATION: The Department of Orthodontics, Pusan National University. Cone-beam computed tomography (CBCT) images of 102 patients in the control group and 95 patients in the crowding group. MATERIALS AND METHODS: X, Y and Z coordinates of the tip of the crowns and the apex of the root of the maxillary teeth (except second molars) were determined on the CBCT images. The acquired three-dimensional (3D) coordinates were converted into two-dimensional (2D) coordinates via projection on the palatal plane, and the Procrustes analysis was employed to process the converted 2D coordinates. The mean shape of the arch form derived from the location of the tip of the crowns and the apex of the root was compared between groups using the statistical shape analysis. RESULTS: There was a statistically significant difference (P = .046) between the groups for the mean shape of the root apex arch form, but the difference was small and clinically irrelevant as it is minor compared to the degree of crowding. CONCLUSIONS: Maxillary arch from at the level of the maxillary apices only shows minor differences between crowded and non-crowded dentitions.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Má Oclusão/diagnóstico por imagem , Má Oclusão/patologia , Maxila/diagnóstico por imagem , Maxila/patologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/patologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
2.
Rev Sci Instrum ; 85(8): 084703, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25173291

RESUMO

Microwave applicators are widely employed for materials heating in scientific research and industrial applications, such as food processing, wood drying, ceramic sintering, chemical synthesis, waste treatment, and insect control. For the majority of microwave applicators, materials are heated in the standing waves of a resonant cavity, which can be highly efficient in energy consumption, but often lacks the field uniformity and controllability required for a scientific study. Here, we report a microwave applicator for rapid heating of small samples by highly uniform irradiation. It features an anechoic chamber, a 24-GHz microwave source, and a linear-to-circular polarization converter. With a rather low energy efficiency, such an applicator functions mainly as a research tool. This paper discusses the significance of its special features and describes the structure, in situ diagnostic tools, calculated and measured field patterns, and a preliminary heating test of the overall system.


Assuntos
Micro-Ondas , Modelos Teóricos
3.
Genes Immun ; 15(5): 333-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24848932

RESUMO

MicroRNAs (miRNAs) regulate the synthesis of cytokines in response to Toll-like receptor (TLR) activation. Our recent microarray study comparing normal and inflamed human dental pulps showed that miRNA-181 (miR-181) family is differentially expressed in the presence of inflammation. Prior studies have reported that the dental pulp, which is composed primarily of TLR4/2+ fibroblasts, expresses elevated levels of cytokines including interleukin-8 (IL-8) when inflamed. In this study, we employed an in-vitro model to determine the role of the miRNA-181 family in the TLR agonist-induced response in human fibroblasts. TLR4/2+ primary human dental pulp fibroblasts were stimulated with lipopolysaccharide from Porphyromonas gingivalis (Pg LPS), a known oral pathogen, and IL-8 and miR-181 expression measured. An inversely proportional relationship between IL-8 and miR-181a was observed. In-silico analysis identified a miR-181a-binding site on the 3' untranslated region (UTR) of IL-8, which was confirmed by dual-luciferase assays. MiR-181a directly binds to the 3'UTR of IL-8, an important inflammatory component of the immune response, and modulates its levels. This is the very first report demonstrating miR-181a regulation of IL-8.


Assuntos
Fibroblastos/metabolismo , Interleucina-8/metabolismo , MicroRNAs/metabolismo , Regiões 3' não Traduzidas , Sítios de Ligação , Células Cultivadas , Polpa Dentária/citologia , Fibroblastos/imunologia , Humanos , Interleucina-8/genética , Lipopolissacarídeos/farmacologia , MicroRNAs/genética , Receptores Toll-Like/agonistas
4.
J Dent Res ; 93(4): 406-11, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24482033

RESUMO

The aim of this study was to determine the effects of glutathione-S-transferase-fused recombinant biglycan (GST-BGN) on craniofacial bone regeneration. We recently demonstrated a positive effect of tissue-derived BGN on bone morphogenetic protein 2 (BMP-2) function, which is exerted likely via the BGN core protein. Here, we investigated the effects of GST-BGN lacking any posttranslational modifications on BMP-2 function in vitro and in vivo. In the C2C12 cell culture system, BMP-2-induced Smad 1/5/8 phosphorylation and alkaline phosphatase activity were both enhanced by the addition of GST-BGN. For the in vivo effect, we employed a Sprague-Dawley rat mandible defect model utilizing 1 µg (optimal) or 0.1 µg (suboptimal) of BMP-2 combined with 0, 2, 4, or 8 µg of GST-BGN. At 2 weeks post-surgery, newly formed bone was evaluated by microcomputed tomography and histologic analyses. The results revealed that the greatest amounts of bone within the defect were formed in the groups of suboptimal BMP-2 combined with 4 or 8 µg of GST-BGN. Also, bone was well organized versus that formed by the optimal dose of BMP. These results indicate that recombinant BGN is an efficient substrate to promote low-dose BMP-induced osteogenesis.


Assuntos
Biglicano/farmacologia , Proteína Morfogenética Óssea 2/farmacologia , Osteogênese/efeitos dos fármacos , Fosfatase Ácida/análise , Fosfatase Alcalina/efeitos dos fármacos , Animais , Biglicano/uso terapêutico , Biomarcadores/análise , Densidade Óssea/efeitos dos fármacos , Proteína Morfogenética Óssea 2/uso terapêutico , Regeneração Óssea/efeitos dos fármacos , Técnicas de Cultura de Células , Linhagem Celular , Colágeno/química , Glutationa Transferase/farmacologia , Isoenzimas/análise , Sistema de Sinalização das MAP Quinases/efeitos dos fármacos , Doenças Mandibulares/patologia , Doenças Mandibulares/fisiopatologia , Ratos , Ratos Sprague-Dawley , Proteínas Recombinantes , Transdução de Sinais/efeitos dos fármacos , Proteína Smad1/efeitos dos fármacos , Proteína Smad5/efeitos dos fármacos , Proteína Smad8/efeitos dos fármacos , Fosfatase Ácida Resistente a Tartarato , Engenharia Tecidual , Alicerces Teciduais/química , Microtomografia por Raio-X
5.
Gene Ther ; 20(2): 158-68, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22402320

RESUMO

Multipotent adult progenitor cells (MAPCs) are bone marrow-derived stem cells with a high growth rate suitable for therapeutical applications as three-dimensional (3D) aggregates. Combined applications of osteogenically differentiated MAPC (OD-MAPC) aggregates and adeno-associated viral vectors (AAV) in bone bioengineering are still deferred until information with regard to expansion technologies, osteogenic potential, and AAV cytotoxicity and transduction efficiency is better understood. In this study, we tested whether self-complementary AAV (scAAV) can potentially be used as a gene delivery system in an OD-MAPC-based 'in vivo' bone formation model in the craniofacial region. Both expansion of rat MAPC (rMAPC) and osteogenic differentiation with dexamethasone were also tested in 3D aggregate culture systems 'in vitro' and 'vivo'. rMAPCs grew as undifferentiated aggregates for 4 days, with a population doubling time of 37 h. After expansion, constant levels of Oct4 transcripts, and Oct4 and CD31 surface markers were observed, which constitute a hallmark of undifferentiated stage of rMAPCs. Dexamethasone effectively mediated rMAPC osteogenic differentiation by inducing the formation of a mineralized collagen type I network, and facilitated the activation of the wnt/ß-catenin, a crucial pathway in skeletal development. To investigate the genetic modification of rMAPCs grown as 3D aggregates before implantation, scAAV serotypes 2, 3 and 6 were evaluated. scAAV6 packaged with the enhanced green fluorescent protein expression cassette efficiently mediated long-term transduction (10 days) 'in vitro' and 'vivo'. The reporter transduction event allowed the tracing of OD-rMAPC (induced by dexamethasone) aggregates following OD-rMAPC transfer into a macro-porous hydroxyapatite scaffold implanted in a rat calvaria model. Furthermore, the scAAV6-transduced OD-rMAPCs generated a bone-like matrix with a collagenous matrix rich in bone-specific proteins (osteocalcin and osteopontin) in the scaffold macro-pores 10 days post-implantation. Newly formed bone was also observed in the interface between native bone and scaffold. The collective work supports future bone tissue engineering applications of 3D MAPC cultures for expansion, bone formation and the ability to alter genetically these cells using scAAV vectors.


Assuntos
Células-Tronco Adultas/citologia , Diferenciação Celular , Osteogênese , Células-Tronco Pluripotentes/citologia , Células-Tronco Adultas/metabolismo , Animais , Regeneração Óssea , Colágeno Tipo I/metabolismo , Dependovirus/genética , Matriz Extracelular/metabolismo , Técnicas de Transferência de Genes , Vetores Genéticos , Fator 3 de Transcrição de Octâmero/genética , Fator 3 de Transcrição de Octâmero/metabolismo , Molécula-1 de Adesão Celular Endotelial a Plaquetas/genética , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo , Células-Tronco Pluripotentes/metabolismo , Ratos , Transplante de Células-Tronco , Transcrição Gênica , Via de Sinalização Wnt
6.
Int Endod J ; 45(2): 146-55, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22070803

RESUMO

AIM: To evaluate the mechanical behaviour of the dentine/cement/post interface of a maxillary central incisor using the finite element method and to compare the stresses exerted using conventional or customized post cementation techniques. METHODOLOGY: Four models of a maxillary central incisor were created using fibreglass posts cemented with several techniques: FGP1, a 1-mm-diameter conventionally cemented post; CFGP1, a 1-mm-diameter customized composite resin post; FGP2, a 2-mm-diameter conventionally cemented post; CFGP2, a 2-mm-diameter customized composite resin post. A distributed load of 1N was applied to the lingual aspect of the tooth at 45° to its long axis. Additionally, polymerization shrinkage of 1% was simulated for the resin cement. The surface of the periodontal ligament was fixed in the three axes (X =Y = Z = 0). The maximum principal stress (σ(max) ), minimum principal stress (σ(min)), equivalent von Mises stress (σ(vM) ) and shear stress (σ(shear)) were calculated for the dentine/cement/post interface using finite element software. RESULTS: The peak of σ(max) for the cement layer occurred first in CFGP1 (1.77 MPa), followed by CFGP2 (0.99), FGP2 (0.44) and FGP1 (0.2). The shrinkage stress (σ(vM) ) of the cement layer occurred as follows: FGP1 (35 MPa), FGP2 (34), CFGP1 (30.7) and CFGP2 (30.1). CONCLUSIONS: Under incisal loading, the cement layer of customized posts had higher stress concentrations. The conventional posts showed higher stress because of polymerization shrinkage.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Planejamento de Prótese Dentária , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Vidro/química , Incisivo/ultraestrutura , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Fenômenos Biomecânicos , Cimentação/métodos , Simulação por Computador , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Teste de Materiais , Modelos Biológicos , Ligamento Periodontal/fisiologia , Polimerização , Resistência ao Cisalhamento , Estresse Mecânico , Propriedades de Superfície , Microtomografia por Raio-X/métodos
7.
Int J Oral Maxillofac Surg ; 38(10): 1088-93, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19647417

RESUMO

The aim of this study was to determine whether elastic properties and apparent density of bone differ in different anatomical regions of the maxilla and mandible. Additional analyses assessed how elastic properties and apparent density were related. Four pairs of edentulous maxilla and mandibles were retrieved from fresh human cadavers. Bone samples from four anatomical regions (maxillary anterior, maxillary posterior, mandibular anterior, mandibular posterior) were obtained. Elastic modulus (EM) and hardness (H) were measured using the nano-indentation technique. Bone samples containing cortical and trabecular bone were used to measure composite apparent density (cAD) using Archimedes' principle. Statistical analyses used repeated measures ANOVA and Pearson correlations. Bone physical properties differed between regions of the maxilla and mandible. Generally, mandible had higher physical property measurements than maxilla. EM and H were higher in posterior than in anterior regions; the reverse was true for cAD. Posterior maxillary cAD was significantly lower than that in the three other regions.


Assuntos
Análise do Estresse Dentário , Arcada Edêntula/patologia , Arcada Edêntula/fisiopatologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Módulo de Elasticidade , Feminino , Dureza , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade
8.
J Oral Rehabil ; 33(7): 501-8, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16774508

RESUMO

Three-dimensional, anisotropic finite element models were executed to investigate the biomechanical effects of in-line and offset placements of implants on implant-supported partial prostheses. Three implant placements of finite element models were created: in-line, buccal offset and lingual offset placements. The mesh models of a cadaver mandibular segment and a three-united crown containing the 2nd premolar, the 1st molar and the 2nd molar were constructed by computer tomography images. The material properties of mandible were applied as transversely isotropic and linearly elastic. Two loading modes (100N), vertical and oblique, were evaluated in all models. Insignificant difference was observed in implant stresses between the in-line and offset placements under the vertical loading mode. Under the oblique loading, however, the offset placement decreased the implant stress by a maximum of 17%. The maximum stress at cortical bone and trabecular bone around each implant did not show conspicuous difference between the in-line and offset placements. This study demonstrated the mechanisms of how stresses were distributed between the in-line and offset placements. Even though the offset placements showed the benefit of decreasing implant stresses, justified from the bone stress the offset placements provided no advantage for the stress decreasing over the in-line placement.


Assuntos
Prótese Dentária Fixada por Implante/métodos , Mandíbula/fisiopatologia , Anisotropia , Implantes Dentários , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Mandíbula/diagnóstico por imagem , Modelos Dentários , Estresse Mecânico , Tomografia Computadorizada por Raios X
9.
J Biomech ; 36(8): 1209-14, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12831748

RESUMO

Information is scarce about Young's modulus of healing bone surrounding an implant. The purpose of this preliminary study is to quantify elastic properties of pig alveolar bone that has healed for 1 month around titanium threaded dental implants, using the nanoindentation method. Two 2-year-old Sinclair miniswine were used for the study. Nanoindentation tests perpendicular to the bucco-lingual cross section were performed on harvested implant-bone blocks using the Hysitron TriboScope III. Nomarski differential interference contrast microscopy was used to identify pyramidal indentation measurements that were from bone. Reduced moduli, averaged for all anatomical regions, were found to start low (6.17 GPa) at the interface and gradually increase (slope=0.014) to a distance of 150 microm (7.89 GPa) from the implant surface, and then flatten to a slope of 0.001 from 150 to 1500 microm (10.13 GPa). Mean reduced modulus and its relationship to distance did not differ significantly by anatomic location (e.g., coronal, middle, and apical third; P>/=0.28 for all relevant tests) at 1 month after implantation.


Assuntos
Processo Alveolar/fisiologia , Dente Pré-Molar/fisiopatologia , Dente Pré-Molar/cirurgia , Remodelação Óssea , Implantes Dentários , Testes de Dureza/métodos , Perda do Osso Alveolar/prevenção & controle , Animais , Dente Pré-Molar/citologia , Elasticidade , Análise de Falha de Equipamento/métodos , Dureza , Técnicas In Vitro , Nanotecnologia/métodos , Propriedades de Superfície , Suínos , Extração Dentária
10.
J Dent Res ; 82(8): 585-91, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12885840

RESUMO

The universally accepted concept of delay-loaded dental implants has recently been challenged. This study hypothesizes that early loading (decreased implant healing time) leads to increased bone formation and decreased crestal bone loss. We used 17 minipigs to study implants under a controlled load, with non-loaded implants for comparison. Radiographic and histological assessments were made of the osseointegrated bone changes for 3 healing times (between implant insertion and loading), following 5 months of loading. The effect of loading on crestal bone loss depended on the healing time. Early loading preserved the most crestal bone. Delayed loading had significantly more crestal bone loss compared with the non-loaded controls (2.4 mm vs. 0.64 mm; P < 0.05). The histological assessment and biomechanical analyses of the healing bone suggested that loading and bioactivities of osteoblasts exert a synergistic effect on osseointegration that is likely to support the hypothesis that early loading produces more favorable osseointegration.


Assuntos
Perda do Osso Alveolar/prevenção & controle , Implantes Dentários , Mandíbula/fisiopatologia , Animais , Planejamento de Prótese Dentária , Modelos Lineares , Mandíbula/cirurgia , Osseointegração , Osteogênese/fisiologia , Estresse Mecânico , Suínos , Porco Miniatura , Fatores de Tempo , Suporte de Carga/fisiologia , Cicatrização/fisiologia
11.
J Dent Res ; 82(6): 438-42, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12766195

RESUMO

Three-dimensional imaging of dental tissues will have a major impact in dentistry if the images are accurate. The purpose of this study was to measure the accuracy and precision of a system for creating three-dimensional images of dental arches. Using vinyl polysiloxane impression materials and improved dental stone, we made 10 stone casts of a "dental" standard with known dimensions. The impressions and casts were scanned by means of a Comet 100 optical scanner. Custom software created three-dimensional images (computer models) from the scanned data. Accuracy was defined as the average of the absolute differences between the computer models and the standard. Precision was the standard deviation of accuracy over 10 repeated measures. Software processing improved the accuracy of the scanner data. Accuracy +/- precision for the casts and impressions was 0.024 +/- 0.002 mm and 0.013 +/- 0.003 mm, respectively. The system produced computer models with sufficient accuracy for clinical application.


Assuntos
Simulação por Computador , Arco Dental/anatomia & histologia , Imageamento Tridimensional , Modelos Anatômicos , Algoritmos , Sulfato de Cálcio , Materiais para Moldagem Odontológica , Materiais Dentários , Humanos , Processamento de Imagem Assistida por Computador , Modelos Dentários , Polivinil , Reprodutibilidade dos Testes , Siloxanas , Software , Propriedades de Superfície , Interface Usuário-Computador
12.
J Dent Res ; 81(5): 338-43, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-12097448

RESUMO

A helical axis describing mandibular motion can be calculated from two distinct positions of the mandible; however, as these positions come closer together, calculation errors increase. This study investigated the effects of errors in the calculated helical axis on simulated mandibular motion by the measurement of changes in occlusal contacts. A standard helical axis was calculated from a simulated lateral movement. A series of digital interocclusal records from centric to a 5 degree mandibular rotation about the standard helical axis was created. Digital dental cast models were aligned to the interocclusal records. Helical axis parameters and occlusal contacts calculated with the use of the aligned digital models were compared with those of the standard. Helical axes calculated from mandibular positions separated by 1.5 degrees to 5.0 degrees yielded equivalent occlusal contacts. Qualitatively, contacts for helical axes calculated from jaw rotations of 0.7 degrees or larger were nearly identical to those of the standard.


Assuntos
Simulação por Computador , Oclusão Dentária , Registro da Relação Maxilomandibular , Modelos Dentários , Articuladores Dentários , Humanos , Imageamento Tridimensional , Registro da Relação Maxilomandibular/métodos , Mandíbula/fisiologia , Movimento , Reprodutibilidade dos Testes
13.
Dent Mater ; 18(3): 281-6, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11823022

RESUMO

OBJECTIVES: The silicone elastomer A-2186 is a widely used maxillofacial prosthetic material. It is a pourable two-component silicone rubber cured by a platinum catalyst. Used as a prosthetic material, A-2186 has short working time and because of its hydrophobic nature, poor adhesion to non-silicone based adhesives. The purpose of this study is to evaluate the physical properties of new prosthetic materials based on methacryloxypropyl-terminated polydimethylsiloxane (MPDS-MF), and to compare the properties with those of A-2186. METHODS: Hardness, tensile strength, ultimate elongation, tear strength and adhesive bonding strength of MPDS-MF and A-2186 with and without additives were determined and compared. The bonding strengths of the extrinsic colorant carrier with the prosthetic materials were also determined. Statistical analyses were done using a two-way analysis of variance (ANOVA). For significant effects, post-hoc tests were done using the Bonferroni correction. RESULTS: The hardness of MPDS-MF is similar to A-2186. However, tensile strength, tear strength, ultimate elongation, and adhesive bonding strength of MPDS-MF are higher than those of A-2186. SIGNIFICANCE: MPDS-MF is cured by free radical thermal polymerization and crosslinking. The working time of MPDS-MF, unlike A-2186, is long. The presence of methacrylate groups in MPDS-MF enhances its adhesion to non-silicone based adhesive. Based on the present study, it appears that MPDS-MF is suitable for use in fabricating of clinical prostheses.


Assuntos
Materiais Biocompatíveis/química , Dimetilpolisiloxanos/química , Prótese Maxilofacial , Adesivos/química , Análise de Variância , Fenômenos Químicos , Físico-Química , Corantes/química , Elasticidade , Radicais Livres/química , Dureza , Temperatura Alta , Humanos , Teste de Materiais , Polímeros/química , Desenho de Prótese , Elastômeros de Silicone/química , Estatística como Assunto , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo
14.
J Prosthodont ; 10(2): 78-85, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11512112

RESUMO

PURPOSE: Future growth in dental practice lies in digital imaging enhancing many chairside procedures and functions. This revolution requires the fast, accurate, and 3D digitizing of clinical records. One such clinical record is the chairside impression. This study investigated how surface angle and surface roughness affect the digitizing of vinyl polysiloxane impression materials. MATERIALS AND METHODS: Seventeen vinyl polysiloxane impression materials were digitized with a white light optical digitizing system. Each sample was digitized at 3 different angles: 0 degrees, 22.5 degrees, and 45 degrees, and 2 digitizer camera f-stops. The digitized images were rendered on a computer monitor using custom software developed under NIH/NIDCR grant DE12225. All the 3D images were rotated to the 0 degrees position, cropped using Corel Photo-Paint 8 (Corel Corp, Ottawa, Ontario, Canada), then saved in the TIFF file format. The impression material area that was successfully digitized was calculated as a percentage of the total sample area, using Optimas 5.22 image processing software (Media Cybernetics, LP, Silver Spring, MD). The dependent variable was a Performance Value calculated for each material by averaging the percentage of area that digitized over the 3 angles. New samples with smooth and rough surfaces were made using the 7 impression materials with the largest Performance Values. These samples were tested as before, but with the additional angle of 60 degrees. Silky-Rock die stone (Whip Mix Corp, Louisville, KY) was used as a control. RESULTS: The Performance Values for the 17 impression materials ranged from 0% to 100%. The Performance Values for the 7 best materials were equivalent to the control at f/11 out to a surface angle of 45 degrees; however, only Examix impression material (GC America Inc, Alsip, IL) was equivalent to the control at f/11/\16. At the 60 degrees surface angle with f/11/\16, the Performance Values were 0% for all the impression materials, whereas that for the control was 90%. The difference in the Performance Values for the smooth and rough surface textures was 7%, which was not significant. CONCLUSIONS: The digitizing performance of vinyl polysiloxane impression materials is highly material and surface angle-dependent and is significantly lower than the die stone control when angles to 60 degrees are included. It is affected to a lesser extent by surface texture.


Assuntos
Materiais para Moldagem Odontológica/química , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Polivinil/química , Siloxanas/química , Análise de Variância , Sulfato de Cálcio/química , Terminais de Computador , Apresentação de Dados , Sistemas de Gerenciamento de Base de Dados , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Luz , Óptica e Fotônica/instrumentação , Elastômeros de Silicone/química , Software , Estatística como Assunto , Propriedades de Superfície
15.
J Oral Rehabil ; 28(6): 517-25, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11422677

RESUMO

Many researches have addressed the high correlation between the fracture of restored teeth and the prepared cavity geometry. In addition, concerns about bonding versus debonding dental materials from cavity walls and different occlusal force conditions could also alter the mechanical responses in a restored tooth. This study employed an automatic mesh procedure to investigate the mechanical interactions between different interfacial conditions and cavity parameters such as pulpal wall depth under different chewing functions. The results indicated that when occlusal force was applied directly on the tooth, it could increase unfavourable stress dramatically. When interfacial fixation was simulated as the contact condition between the tooth tissue and restorative material, it might increase the fracture potential exponentially compared with the bonded interface. For pulpal wall depth analyses, greater risks of fracture for the remaining tooth were observed in deeper cavity of mesio-occlusal-distal (MOD) restorations and the existence of a pulpal wall is essential even it is only 1 mm above the gingival wall.


Assuntos
Preparo da Cavidade Dentária/métodos , Restauração Dentária Permanente/métodos , Análise de Elementos Finitos , Modelos Biológicos , Dente/fisiologia , Força de Mordida , Simulação por Computador , Colagem Dentária , Materiais Dentários/química , Polpa Dentária/anatomia & histologia , Polpa Dentária/fisiologia , Humanos , Mastigação/fisiologia , Estresse Mecânico , Dente/anatomia & histologia , Fraturas dos Dentes/etiologia , Fraturas dos Dentes/fisiopatologia
16.
J Oral Rehabil ; 28(6): 576-85, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11422685

RESUMO

The use of an mesial-occlusal-distal (MOD) restoration in repairing a large carious lesion depends on many factors. Biomechanical performance is one of the most important. It has been recognized that resistance to restoration failure is not solely a biological concern (e.g. toxicity), but that the cavity shape, dimensions, and the state of stress must all be taken into account. In the present study, a newly developed auto-mesh program was used to generate 30 three-dimensional (3D) finite element (FE) models simulating the biomechanics for multiple factorial design of the MOD gold restoration in a maxillary second premolar. Stress levels were related to individual design factors (e.g. pulpal wall depth [P], isthmus width [W] and interaxial thickness [T]) and to their interactions under the worst physiological scenario: a concentrated bite force acting on lingual cusp with debonded interfaces between cavity walls and restorations. The results showed that enlarging the volume of the MOD cavity significantly increased stresses in enamel but did not intentionally affect stresses in dentin. The alternation of individual design parameters significantly changed the peak stresses (P < 0.05). For all three parameters, except for the width, the peak stress increased as the cavity dimension increased. Stress elevation rate (termed as 'volumetric stress rate'--stress elevation by increasing one unit volume of the restored materials) was different among three design factors. Depth was the most critical factor governing the stress elevation in enamel (1.76 MPa mm(-3)) while length (interaxial thickness) was the most important parameter in dentin (0.49 MPa mm(-3)). Width was the least compromising factor to the remaining tooth, 0.32 MPa mm(-3) for enamel and -0.23 MPa mm(-3) for dentin. The findings, at its core, did not fully agree with the traditional concept that the preservation of tooth substances will reduce risk of tooth fracture. This study leaves open possibility for the structural optimization of the MOD restoration.


Assuntos
Dente Pré-Molar/fisiologia , Restauração Dentária Permanente/métodos , Análise de Elementos Finitos , Ligas de Ouro , Dente Pré-Molar/anatomia & histologia , Fenômenos Biomecânicos , Força de Mordida , Simulação por Computador , Preparo da Cavidade Dentária/classificação , Preparo da Cavidade Dentária/métodos , Esmalte Dentário/anatomia & histologia , Esmalte Dentário/fisiologia , Polpa Dentária/anatomia & histologia , Polpa Dentária/fisiologia , Restauração Dentária Permanente/classificação , Dentina/anatomia & histologia , Dentina/fisiologia , Análise Fatorial , Ligas de Ouro/química , Humanos , Modelos Biológicos , Estresse Mecânico , Propriedades de Superfície , Fraturas dos Dentes/fisiopatologia
18.
Auton Neurosci ; 94(1-2): 25-33, 2001 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-11775704

RESUMO

The present study investigated the contributions of vagal and nonvagal sensory nerve fibers on neurogenic inflammation in rat bronchial airways. A surgical procedure was developed via the rat mediastinum ventral intercostal space to prepare an intercostal opening without causing pneumothorax for performing stellate ganglionectomy alone, thoracic vagus nerve section alone, and stellatectomy plus thoracic vagotomy, and for injecting capsaicin (2 microl, 10 mg/ml) and 6-hydroxydopamine (2 microl, 50 mg/ml) into the ganglion. One week later in our procedure, we investigated if neurogenic inflammation induced by an intravenous injection of capsaicin (300 nmol/ml/kg) and innervation density of substance P-immunoreactive sensory axons could be decreased after chronic denervation in the rat lower airways. The major findings were that surgical removal of the right stellate ganglion and local capsaicin application resulted in a significant attenuation of neurogenic plasma extravasation in the right bronchial tree evoked by systemic capsaicin application. Reduction of neurogenic plasma extravasation was totally abolished by combined stellatectomy and thoracic vagotomy. The number of substance P-containing axons was also greatly decreased following these surgical and capsaicin treatments. It is concluded that sensory nerve fibers from both vagal source and nonvagal (spinal) source, which associated with the stellate ganglion, contributed significantly to neurogenic inflammation in the bronchial airways with a slightly higher contribution from the vagus nerve.


Assuntos
Bronquite/patologia , Capsaicina/farmacologia , Ganglionectomia , Gânglio Estrelado/efeitos dos fármacos , Gânglio Estrelado/fisiologia , Animais , Axônios/metabolismo , Brônquios/inervação , Bronquite/prevenção & controle , Permeabilidade Capilar/efeitos dos fármacos , Feminino , Imuno-Histoquímica , Masculino , Oxidopamina , Ratos , Ratos Sprague-Dawley , Substância P/metabolismo , Simpatectomia Química , Vagotomia
19.
J Prosthet Dent ; 84(4): 436-43, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11044852

RESUMO

STATEMENT OF PROBLEM: Noncarious cervical lesions are described as having a multifactorial cause, with occlusal trauma and toothbrush abrasion frequently mentioned as major factors. Finite element modeling studies have demonstrated a relocalization of occlusal stresses to the cervical area due to flexure of the crown. This may cause microcracking, especially under tensile stresses, that will lead to a loss of enamel and dentin in the cervical region. Clinical confirmation of an occlusal cause for noncarious cervical lesions has been difficult to obtain. PURPOSE: This study investigated whether occlusal wear was correlated with an increase in the size of noncarious cervical lesions. MATERIAL AND METHODS: Loss of contour at occlusal and cervical sites on 3 teeth of a single individual was measured using digital and visualization techniques at 3 time intervals over a 14-year time span. The 1983 baseline casts and 1991, 1994, and 1997 clinical impressions of a single adult patient with existing noncarious cervical lesions were replicated in epoxy. Surfaces of all replicas were digitized with a contact digitizing system. Sequential digitized surfaces were fit together and analyzed using AnSur-NT surface analysis software. Clinical losses of surface contour by volume and depth of the left mandibular first molar and first and second premolars were recorded. RESULTS: Nine measurements of cervical volume loss (range 0.9 to 11.5 mm(3)) and 9 corresponding measurements of occlusal volume loss (range 0.39 to 7.79 mm(3)) were made. The correlation between occlusal and cervical volume loss was strong (r(2)=0.98) and significant (P<.0001). CONCLUSION: For the single adult patient in this study, there was a direct correlation between occlusal wear and the growth of noncarious cervical lesions.


Assuntos
Oclusão Dentária Traumática/complicações , Análise do Estresse Dentário , Abrasão Dentária/complicações , Colo do Dente/patologia , Adulto , Dente Pré-Molar , Força de Mordida , Simulação por Computador , Técnica de Moldagem Odontológica , Análise do Estresse Dentário/métodos , Análise de Elementos Finitos , Humanos , Estudos Longitudinais , Masculino , Mandíbula , Modelos Dentários , Dente Molar , Resistência à Tração , Abrasão Dentária/etiologia , Abrasão Dentária/patologia , Coroa do Dente/fisiopatologia
20.
J Dent Res ; 79(8): 1584-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11023279

RESUMO

Mineral loss in early caries cannot be measured without invasive procedures. To quantify mineral loss without sectioning the tooth, one must determine the optical scattering of the enamel. Using enamel white-spot lesions, we hypothesize that the optical scattering power (Sp) of the demineralized enamel would provide a quantitative estimate of mineral loss. Enamel slabs were demineralized to produce artificial white spots. The data were acquired by means of a Charge-Coupled Device (CCD) camera and image-processing software. For the purpose of comparison, mineral loss (deltaZ) of the demineralized samples was determined by the use of a microhardness approach after the samples were sectioned. The scattering power correlated well with deltaZ (r2 = 0.82). In contrast, simple reflectance of the demineralized samples correlated poorly with deltaZ (r2 = 0.22). The validity of using scattering power to measure demineralization has been confirmed by a three-dimensional Monte Carlo Simulation.


Assuntos
Cárie Dentária/diagnóstico , Esmalte Dentário/fisiologia , Desmineralização do Dente/fisiopatologia , Animais , Bovinos , Simulação por Computador , Cárie Dentária/fisiopatologia , Esmalte Dentário/química , Permeabilidade do Esmalte Dentário , Tecnologia de Fibra Óptica , Dureza , Processamento de Imagem Assistida por Computador , Modelos Lineares , Método de Monte Carlo , Óptica e Fotônica , Fotografação/instrumentação , Refratometria , Reprodutibilidade dos Testes , Espalhamento de Radiação , Semicondutores , Desmineralização do Dente/diagnóstico , Transiluminação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...