Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
2.
Anaesthesia ; 75(4): 529-540, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31701521

RESUMO

The cost effectiveness of reusable vs. single-use flexible bronchoscopy in the peri-operative setting has yet to be determined. We therefore aimed to determine this and hypothesised that single-use flexible bronchoscopes are cost effective compared with reusable flexible bronchoscopes. We conducted a systematic review of the literature, seeking all reports of cross-contamination or infection following reusable bronchoscope use in any clinical setting. We calculated the incidence of these outcomes and then determined the cost per patient of treating clinical consequences of bronchoscope-induced infection. We also performed a micro-costing analysis to quantify the economics of reusable flexible bronchoscopes in the peri-operative setting from a high-throughput tertiary centre. This produced an accurate estimate of the cost per use of reusable flexible bronchoscopes. We then performed a cost effectiveness analysis, combining the data obtained from the systematic review and micro-costing analysis. We included 16 studies, with a reported incidence of cross-contamination or infection of 2.8%. In the micro-costing analysis, the total cost per use of a reusable flexible bronchoscope was calculated to be £249 sterling. The cost per use of a single-use flexible bronchoscope was £220 sterling. The cost effectiveness analysis demonstrated that reusable flexible bronchoscopes have a cost per patient use of £511 sterling due to the costs of treatment of infection. The findings from this study suggest benefits from the use of single-use flexible bronchoscopes in terms of cost effectiveness, cross-contamination and resource utilisation.


Assuntos
Broncoscópios/economia , Broncoscopia/instrumentação , Análise Custo-Benefício/economia , Equipamentos Descartáveis/economia , Reutilização de Equipamento/economia , Broncoscopia/economia , Desenho de Equipamento , Humanos
3.
J Hosp Infect ; 97(4): 319-328, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28729139

RESUMO

Inadequate drying of endoscope channels is a possible cause of replication and survival of remaining pathogens during storage. The presence during storage of potentially contaminated water in endoscope channels may promote bacterial proliferation and biofilm formation. An incomplete drying procedure or lack of drying and not storing in a vertical position are the most usual problems identified during drying and endoscope storage. Inadequate drying and storage procedures, together with inadequate cleaning and disinfection, are the most important sources of endoscope contamination and post-endoscopic infection. Flexible endoscopes may be dried in automated endoscope reprocessors (AERs), manually, or in drying/storage cabinets. Flushing of the endoscope channels with 70-90% ethyl or isopropyl alcohol followed by forced air drying is recommended by several guidelines. Current guidelines recommend that flexible endoscopes are stored in a vertical position in a closed, ventilated cupboard. Drying and storage cabinets have a drying system that circulates and forces the dry filtered air through the endoscope channels. Endoscope reprocessing guidelines are inconsistent with one another or give no exact recommendations about drying and storage of flexible endoscopes. There is no conclusive evidence on the length of time endoscopes can be safely stored before requiring re-disinfection and before they pose a contamination risk. To minimize the risk of disease transmission and nosocomial infection, modification and revision of guidelines are recommended as required to be consistent with one another.


Assuntos
Dessecação/métodos , Endoscópios/microbiologia , Contaminação de Equipamentos , Descontaminação/métodos , Transmissão de Doença Infecciosa/prevenção & controle , Desinfecção/métodos , Humanos , Doença Iatrogênica/prevenção & controle
4.
Georgian Med News ; (255): 81-5, 2016 Jun.
Artigo em Russo | MEDLINE | ID: mdl-27441541

RESUMO

The aim of the study was to determine the concentrations of inflammatory markers C-reactive protein (C-RP) and cytokines - IL-1ß, IL-4 in patients with arterial hypertension (AH) and obesity. The study involved 64 patients with hypertension, who were divided into 2 groups. The first (main group) consisted of 39 patients with arterial hypertension II degree and obesity 1 st. The second group was performed by 25 patients diagnosed with hypertension II degree without obesity. The study of serum cytokines was carried out by ELISA using the company>s «Ukrmedservis¼ sets, Ukraine, and for the C-RP - set, company «DRG International Inc.¼ (USA) following instructions. Obesity was assessed by body mass index and waist to hip ratio. The study found that hypertension with obesity is characterized by a more pronounced increasing in the C-RP and IL-1 ß and reducing in anti-inflammatory IL-4, in comparison with the control group. And this is the evidence of a significant activation of inflammatory processes in such cohort of the patients. Thus immunoinflammatory disorders are essential in the development of hypertension in combination with obesity. A direct link is detected between obesity and the severity of inflammation in patients with hypertension.


Assuntos
Proteína C-Reativa/metabolismo , Hipertensão/sangue , Interleucina-1beta/sangue , Interleucina-4/sangue , Obesidade/sangue , Idoso , Biomarcadores/sangue , Feminino , Humanos , Hipertensão/complicações , Hipertensão/imunologia , Inflamação/sangue , Inflamação/imunologia , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/imunologia
5.
J Hosp Infect ; 76(4): 345-50, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20951470

RESUMO

The effects of peracetic acid-based (PAA) disinfectant with, and without, additional drying on Candida albicans, Candida parapsilosis, Pseudomonas aeruginosa and Stenotrophomonas maltophilia, isolated from contaminated flexible endoscopes, in single- and dual-species biofilms were studied. Biofilms were prepared in sterile tissue culture polystyrene 96-well microtitre plates and were quantified using the tetrazolium salt (MTT) reduction assay and by counting colony-forming yeasts and bacteria from 10-fold serial biofilm dilutions on agar plates. An in vitro biofilm model was applied to mimic the biofilm formation inside the endoscope channels and to imitate the disinfection and drying procedures used for reprocessing of flexible endoscopes. The PAA-based disinfectant was effective against bacteria and yeasts in the planktonic and biofilm states directly after treatment, but allowed regrowth of all biofilms if the drying procedure was skipped. No biofilm regrowth occurred in wells after a drying procedure in all single- and dual-species biofilms. Routine cleaning procedures do not remove biofilm reliably from endoscope channels if the accurate drying procedure is not applied. This may explain the failure of decontamination during endoscope reprocessing.


Assuntos
Biofilmes/efeitos dos fármacos , Candida/efeitos dos fármacos , Desinfetantes/farmacologia , Endoscópios/microbiologia , Ácido Peracético/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Stenotrophomonas maltophilia/efeitos dos fármacos , Candida/fisiologia , Desinfecção/métodos , Humanos , Viabilidade Microbiana/efeitos dos fármacos , Modelos Biológicos , Pseudomonas aeruginosa/fisiologia , Stenotrophomonas maltophilia/fisiologia , Sais de Tetrazólio/metabolismo , Tiazóis/metabolismo
6.
Endoscopy ; 41(10): 913-6, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19750453

RESUMO

Endoscopes, including duodenoscopes, are medical devices that are frequently associated with outbreaks of nosocomial infections. We investigated an outbreak of multidrug-resistant PSEUDOMONAS AERUGINOSA sepsis affecting three patients after endoscopic retrograde cholangiopancreaticography (ERCP). Epidemiologic investigation supplemented by molecular typing revealed that one ERCP scope was the source of infection with P. AERUGINOSA. No contamination with this microorganism was found after screening of washer-disinfectors, connecting tubes, and environmental surfaces in the endoscopy center. PSEUDOMONAS isolates from blood and endoscope channels before gas sterilization with ethylene oxide (ETO) were characterized by molecular typing as "linked isolates". Though the current surveillance system did not prevent the infections in three patients, our microbiological surveillance protocol with routine culturing of endoscopes was helpful in detecting the source of contamination and probably avoided numerous cross-contaminations in other patients who underwent ERCP procedures with endoscopes.


Assuntos
Infecção Hospitalar/microbiologia , Surtos de Doenças/prevenção & controle , Duodenoscópios/microbiologia , Infecções por Pseudomonas/prevenção & controle , Sepse/microbiologia , Idoso , Farmacorresistência Bacteriana Múltipla , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções por Pseudomonas/etiologia , Pseudomonas aeruginosa/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...