Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Front Immunol ; 15: 1348430, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38840911

RESUMO

Introduction: Spontaneous cervical artery dissection (sCAD) is a rare vasculopathy whose trigger is still unknown. We hypothesized that autoimmunity against components of the vascular wall might play a critical role in sCAD and examined anti-collagen type I antibodies in patients with sCAD, acute ischemic stroke, patients with thromboendarterectomy, and controls. Methods: Fifty-seven patients with sCAD (age 45.7 ± 10.2 years, female 18 (31.6%)) were prospectively enrolled in four German stroke centers. Blood samples were collected at baseline, at day 10 ± 3, and after 6 ± 1 months. Patients with ischemic stroke not related to CAD (n=54, age 56.7 ± 13.7 years, female 15 (27.8%)), healthy probands (n=80, age 57.4 ± 12.9 years, female 56 (70%)), and patients undergoing thromboendarterectomy of the carotid artery (n=9, age 70.7 ± 9.3 years, female 2 (22.2%)) served as controls. Anti-collagen type I antibodies were determined by enzyme-linked immunosorbent assays (ELISAs). Results: Patients with acute sCAD had higher serum levels of anti-collagen type I antibodies (33.9 ± 24.6 µg/ml) than probands (18.5 ± 11.0 µg/ml; p <0.001) but lower levels than patients with ischemic stroke not related to sCAD (47.8 ± 28.4 µg/ml; p=0.003). In patients with sCAD, serum levels of anti-collagen type I antibodies were similar in the acute, subacute, and chronic phase. Levels of anti-collagen type I antibodies significantly correlated with circulating collagen type I (rho=0.207, p=0.003). Conclusion: Anti-collagen type I antibodies seem not to represent a trigger for acute sCAD or ischemic stroke but may rather be linked to the metabolism and turnover of collagen type I.


Assuntos
Autoanticorpos , Colágeno Tipo I , AVC Isquêmico , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Colágeno Tipo I/imunologia , Colágeno Tipo I/sangue , Estudos Prospectivos , AVC Isquêmico/imunologia , AVC Isquêmico/sangue , Adulto , Idoso , Autoanticorpos/sangue , Autoanticorpos/imunologia , Dissecação da Artéria Vertebral/imunologia , Dissecação da Artéria Vertebral/sangue , Dissecação da Artéria Vertebral/cirurgia
2.
Transl Stroke Res ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37945800

RESUMO

An impaired integrity of vascular elements and the extracellular matrix (ECM) has been discussed to play a critical role in the pathophysiology of spontaneous cervical artery dissection (sCAD). This study aimed to explore the temporal course of circulating elastin, collagen type I, and collagen type III in patients with sCAD and evaluated their eligibility as diagnostic biomarkers. Patients with sCAD were prospectively enrolled in four German stroke centers. Blood samples were collected at baseline (acute phase), at day 10 ± 3 (subacute phase), and after 6 ± 1 months (chronic phase). Patients with acute ischemic stroke not related to sCAD, healthy probands, and patients undergoing thromboendarterectomy of the carotid artery served as control groups. Serum levels of elastin and collagen types I and III were determined by ELISAs. Fifty-seven patients with sCAD were enrolled. Compared to all three control groups, patients with sCAD had significantly lower levels of elastin and collagen type III at baseline and after 6 months. Compared to healthy probands, patients with sCAD showed similar collagen type I levels at baseline and in the subacute phase, but significantly increased levels after 6 months. As serum levels of elastin, collagen types I and III were not elevated in the acute phase, they do not appear eligible as biomarkers for the diagnosis of sCAD. Persisting low serum levels of elastin and collagen type III towards the chronic phase of sCAD strengthens the hypothesis of a subtle, in most cases clinically inapparent affection of the ECM in patients with sCAD.

3.
Nervenarzt ; 93(6): 575-582, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-34731278

RESUMO

BACKGROUND: To improve the sensitivity of the EEG in the diagnosis and classification of seizures or epilepsy, long-term recording with inferior temporal electrodes are recommended. MATERIAL AND METHODS: The spatial distribution of epileptiform discharges from 24­h EEG with 25 electrodes (10-20, extended by F9/F10, T9/T10, P9/P10) was retrospectively analyzed in 25 cases. RESULTS: Maximum negativity was located below the 10-20 electrodes in 84%. Epileptiform discharges were more clearly detected on inferior temporal electrodes in 64%. In the intention-to-test population of 77 patients the number needed to test with extra electrodes was estimated as 5. CONCLUSION: Recording EEG with 25 electrodes for 24 h improves the detection and localization of temporal epileptiform discharges also in geriatric patients with suspected nonlesional epilepsy.


Assuntos
Eletroencefalografia , Epilepsia , Idoso , Eletrodos , Epilepsia/diagnóstico , Humanos , Estudos Retrospectivos , Convulsões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...