Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Biopolymers ; : e23607, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884122

RESUMO

A simple, cost-effective, one-pot method was proposed to introduce bis-phosphonic groups onto alginic acid and carboxymethyl cellulose (CMC). New derivatives were characterized by means of nuclear magnetic resonance, X-ray photoelectron, and attenuated total reflectance Fourier transform infrared spectroscopy. These analyses confirmed the successful transformation of carboxylic groups present in alginic acid and CMC into bis-phosphonic groups. Additionally, thermogravimetric analysis coupled with differential scanning calorimetry was employed to investigate the thermal properties of the bis-phosphonic derivatives of alginate and CMC. The results clearly demonstrate the char-forming ability of both studied bis-phosphonated polycarbohydrates, suggesting their potential as intumescent materials.

2.
Knee ; 48: 217-225, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38733872

RESUMO

BACKGROUND: Anterior knee pain (AKP) is one of the reasons for dissatisfaction after total knee replacement (TKR). It may result from patellofemoral joint dysfunction, caused by improper rotation of implant components. The aim of this study was to analyze patella positioning in patients after standard measured resection TKR and TKR with a use of a dynamic tensioner, and to assess the frequency of AKP, range of motion (ROM), and patient-reported outcome measures 6 weeks and 3 months postoperatively. METHODS: The study consisted of 127 patients who underwent TKR. Eighty-nine of them treated with use of the dynamic tensioner FUZION formed the study group; the remainder formed the control group. All participants received cemented PERSONA MC without patella resurfacing. All patients had a standard anteroposterior, lateral weight-bearing, long-leg view X-ray and computed tomography examination in 30° of knee flexion following the procedure. RESULTS: There were no significant differences between the study and the control groups regarding: posterior condylar axis (PCA)-patella angle, surgical transepicondylar axis (sTEA)-patella angle, PCA-sTEA angle, deviation from 90° in PCA-patella, sTEA-patella and PCA-sTEA angles. No significant difference was found in a ratio of obtaining PCA-patella angle deviation of more than 3°. Regarding clinical parameters, statistically and questionablly clinically significant difference in favor of the Study Group was found in Forgotten Joint Score 6 weeks and 3 months post-operativley and ROM 6 weeks post-operatively. However, such difference was not found by analyzing ROM 3 months post-operatively, AKP and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores. CONCLUSION: Compared with the standard 3° of femoral component external rotation, use of a dynamic tensioner does not allow for more accurate restoration of the patellar facet position with reference to the PCA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Patela , Amplitude de Movimento Articular , Humanos , Artroplastia do Joelho/métodos , Masculino , Feminino , Estudos de Casos e Controles , Amplitude de Movimento Articular/fisiologia , Idoso , Patela/cirurgia , Pessoa de Meia-Idade , Rotação , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/fisiopatologia , Fêmur/cirurgia , Desenho de Prótese , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Joelho/diagnóstico por imagem
3.
Int J Mol Sci ; 25(10)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38791498

RESUMO

The post-column reaction method enables the evaluation of the antiradical capacity of individual components in a mixture by separating the components using HPLC and measuring stable free radical (e.g., DPPH●) scavenging that occurs after the chromatography column. The equipment typically consists of two detectors. The first records signals of the analytes leaving the column. The second records radical scavenging by the analytes, which appears as a negative band. The recorded signals are found on two separate chromatograms, which must be combined to interpret the results. In this study, a single DAD detector was used behind the post-column reactor, enabling the simultaneous recording of the analyte bands and negative signals, indicating radical scavenging. The objective of this study was to evaluate the antiradical capacity of key compounds found in two herbal raw materials used in traditional Chinese medicine. Saposhnikovia divaricata roots contain phenolic acids, chromones, and furanocoumarins. Chlorogenic acid, rosmarinic acid, and imperatorin demonstrated strong radical scavenging, while prim-O-glucoslocimifugin showed a weaker response, both in standards and in root extracts. However, scavenging was not observed for cimifugin and 4'-O-ß-D-glucosyl-5-O-methylvisamminol. Astragalus mongholicus roots contain astragalosides I-IV (triterpene saponins). None of these showed DPPH● scavenging. Furthermore, additional signals were observed, indicating the presence of unidentified radical scavenging compounds.


Assuntos
Sequestradores de Radicais Livres , Extratos Vegetais , Plantas Medicinais , Plantas Medicinais/química , Extratos Vegetais/química , Cromatografia Líquida de Alta Pressão/métodos , Sequestradores de Radicais Livres/química , Apiaceae/química , Raízes de Plantas/química , Cromonas/análise , Cromonas/química , Furocumarinas/química , Furocumarinas/análise
4.
Reumatologia ; 62(2): 128-133, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799773

RESUMO

Introduction: Total hip arthroplasty (THA) is nowadays considered as the most effective treatment option for end-stage hip osteoarthritis (OA) and one of the most successful orthopedic procedures. Precise reproduction of the center of rotation (COR) is among the most important aspects of recreating native hip biomechanics after THA as it is strictly related to muscle tension and force distribution within the hip joint. Both vertical and horizontal shift in cup positioning and COR restoration are commonly observed radiological signs corresponding with lesser functional outcome. The aim of this study was to assess whether the superior border of the native acetabulum morphology has an impact on cup positioning and COR restoration in patients undergoing THA as treatment of primary OA of the hip. Material and methods: A cohort of 150 consecutive patients with diagnosis of end-stage primary hip OA who underwent THA via an anterolateral approach with the same implant in 2021 was analyzed retrospectively. Standard standing pelvic X-rays were performed pre- and postoperatively and appropriate measurements were taken. Several radiological parameters on obtained X-rays were assessed. Statistical analysis of all the measurements was performed. Results: There was a statistically significant positive weak correlation between cup offset and acetabular roof angle (rs = 0.25, p = 0.002). There were statistically insignificant positive correlations between acetabular roof angle and COR restoration (rs = 0.14, p = 0.097), acetabular roof angle and total offset (rs = 0.087, p = 0.29) and a negative correlation between acetabular roof angle and femoral offset (rs = 0.071, p = 0.39). Conclusions: The present study revealed that preoperative acetabular roof angle influences the positioning of the prosthetic cup in the transverse axis. There also seems to be a correlation between the acetabular roof angle and COR restoration, but its significance needs further evaluation. Surgeons could use this knowledge to preoperatively assess the risk of cup malposition and adjust their technique during the THA procedure with probable improvement of hip function.

5.
Reumatologia ; 62(2): 121-127, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38799774

RESUMO

Introduction: Fracture of the proximal femur is common in elderly patients, in fact threatening their lives. Age-related sarcopenia may be involved in the imbalance resulting in the injury. Handy and readily accessible biochemical tests would be useful to assess the musculoskeletal system condition in daily practice. The aim of the study was to determine whether there is any relation between muscle decay and fracture of the proximal femur and to assess bone quality in elderly patients. Material and methods: In the study 22 patients who represented the treatment group were hospitalized due to proximal femur fracture. Eighteen patients from the control group with no fracture in their history were admitted to the Internal Medicine Department. Anyone treated for osteoporosis, immune disease affecting protein balance, neoplasm, mental illness, heart failure, or myocardial infarction was excluded from the study. In every case a blood sample from an elbow vein was drawn, collected in EDTA-K2 tubes, and then centrifuged to separate plasma from the whole blood. Subsequently, the concentrations of C-terminal cross-linked telopeptide of type I collagen (CTX-I), sex hormone binding globulin (SHBG) and creatine kinase (CK) in plasma were determined using commercial enzyme-linked immunosorbent assays. Results: The CK plasma concentration differed between the patient groups (p = 0.011). The SHBG plasma concentration was significantly higher in the treatment group (p = 0.006), whereas a slight difference in CTX-I plasma concentration between the groups was found (p = 0.038). No significant correlations between plasma CK, SHBG or CTX-I were found (p > 0.05). Conclusions: Creatine kinase is actually not an appropriate marker for the clinical assessment of muscle tissue quality in patients with or at risk of proximal femur fracture. Analyzing the quality of bone tissue, we can conclude it was poorer in patients with proximal femur fracture than in the control group.

6.
Chemosphere ; 338: 139538, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37478995

RESUMO

A novel, biomass-derived hybrid sorbent Ban-CD-EPI-Fe was successfully synthesized in a coprecipitation method, in which ß-cyclodextrin copolymerized with banana peel extract and epichlorohydrin was grafted onto an iron oxide surface. The composition, presence of functional groups, morphology, thermal stability, and magnetic properties of the obtained material were characterized by Powder X-Ray Diffraction (XRD), X-Ray Photoelectron Spectroscopy (XPS), Fourier Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy and Energy Dispersive X-Ray Spectroscopy (SEM-EDS), Thermogravimetric Analysis (TGA), and Physical Properties Measurement System (PPMS). The material bearing around 28% of ß-cyclodextrin units has mesoporous structure with plate-like morphology and active surface area determined by BET and Langmuir models equal to 38.35 and 53.59 m2 g-1, respectively. The sorption studies aimed to remove an endocrine disruptor - bisphenol A (BPA), from water. The results showed that the time evolution could be fitted with pseudo-second kinetic order with a rate constant k equal to 0.05 g mg-1 min-1. According to the Langmuir isotherm, a monolayer is created during BPA sorption, and the maximum sorption capacity was estimated as 93.5 mg g-1. After BPA sorption, the hybrid material could be easily separated by an external magnet and regenerated under mild conditions keeping its recyclability in at least eight cycles.


Assuntos
Poluentes Químicos da Água , beta-Ciclodextrinas , Poluentes Químicos da Água/análise , Adsorção , beta-Ciclodextrinas/química , Fenômenos Magnéticos , Espectroscopia de Infravermelho com Transformada de Fourier , Cinética
7.
BMC Musculoskelet Disord ; 24(1): 610, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491199

RESUMO

BACKGROUND: Total knee replacement (TKR) is considered one of the most common elective orthopaedic procedures. The main focus of TKR is to offer patient's symptomatic relief from persistent knee pain. To achieve this it is crucial to restore joint biomechanics by performing proper bone cuts. Some surgeons favor the measured resection technique, others prefer gap balancing technique. The researchers of the presented study performed TKR using these two techniques. The aim of this study was to compare the postoperative change in joint line and posterior condylar offset after TKR with use of anatomic knee design implants between gap balancing and measured resection techniques. METHODS: Two hundred twenty-five X-rays of patients who underwent TKR performed by a single surgeon between 2020 and 2021 were analyzed. The first group of patients (101) was operated with the use of gap balancing technique and the second group (124) was operated with the use of measured resection technique. Patients included in the study were > 50 years of age, had confirmed primary knee osteoarthritis, underwent primary TKR with a PS (posterior stabilized) knee implants without patella resurfacing and had at least 15 degree flexion contracture. T-student test and U Mann-Whitney test were used in statistical analysis of results, according to the normality of distribution examined with the Shapiro-Wilk test. Post-hoc analysis was performed using the Dwass-Steel-Crichtlow-Fligner test (DSCF). RESULTS: The postoperative analysis showed a significantly elevated joint line level in the gap balancing group (-2.6 ± 4.1 vs -0.7 ± 4.8, p < 0.0005). In the gap balancing group significantly more patients had joint lines elevated > 2 mm comparing to measured resection technique. The difference between pre- and postoperative PCO (posterior condylar offset) and PCOR (posterior condylar offset ratio) results had no significant differences (100.8 ± 11.8 vs 101 ± 12.5, p > 0.05) between the groups. CONCLUSIONS: The results of the study suggest that when it comes to restoring joint line level measured resection technique seems to be superior in comparison to the gap balancing technique. What is more, results indicate measured resection is equal in terms of restoring posterior condylar offset to the gap balancing technique. TRIAL REGISTRATION: NCT04164147, date of registration: November 14, 2019.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Estudos de Coortes , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
8.
Sci Rep ; 13(1): 10107, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37344514

RESUMO

Formation of plasmonically active silver, copper and composite silver-copper nanostructures were studied in this paper. Metallic nanostructures were fabricated by thermal disintegration, so called dewetting, of the thin films in an argon atmosphere. The formation process of the nanostructures was in-situ observed by a novel method, based on resistance measurements. The influence of the material and thickness of the initial thin film on temperature of their disintegration was investigated. Electrical measurements were validated by scanning electron microscopy observations, while metallic the behavior of nanostructures was studied by XPS method. The formation of silver-copper nanocomposite structures was confirmed by UV-vis spectroscopy. Plasmon resonance with two characteristic peaks for nanocomposite structures was observed.

9.
Medicina (Kaunas) ; 59(5)2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37241112

RESUMO

Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic-assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher's exact, Kruskal-Wallis and Dwass-Steel-Crichtlow-Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0° in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia , Próteses e Implantes
10.
Beilstein J Nanotechnol ; 14: 420-433, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025365

RESUMO

In this work, the specific role of the addition of graphene oxide (GO) to state-of-the-art nickel-iron (NiFe) and cobalt-nickel-iron (CoNiFe) mixed oxides/hydroxides towards the oxygen evolution reaction (OER) is investigated. Morphology, structure, and OER catalytic activity of the catalysts with and without GO were studied. The catalysts were fabricated via a two-step electrodeposition. The first step included the deposition of GO flakes, which, in the second step, were reduced during the simultaneous deposition of NiFe or CoNiFe. As a result, NiFe-GO and CoNiFe-GO were fabricated without any additives directly on the nickel foam substrate. A significant improvement of the OER activity was observed after combining NiFe with GO (OER overpotential η(10 mA·cm-2): 210 mV) compared to NiFe (η: 235 mV) and GO (η: 320 mV) alone. A different OER activity was observed for CoNiFe-GO. Here, the overall catalytic activity (η: 230 mV) increased compared to GO alone. However, it was reduced in comparison to CoNiFe (η: 224 mV). The latter was associated with the change in the morphology and structure of the catalysts. Further OER studies showed that each of the catalysts specifically influenced the process. The improvement in the OER by NiFe-GO results mainly from the structure of NiFe and the electroactive surface area of GO.

11.
Arch Orthop Trauma Surg ; 143(9): 5901-5907, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37000268

RESUMO

INTRODUCTION: During the last years, main attention while performing total knee replacement was paid to femoral component alignment; however, there is still lack of studies concerning tibial baseplate rotational alignment, especially in terms of anatomical designs of knee prosthesis. Some recent studies proved that tibial baseplate malrotation might be a cause of knee pain and patients' dissatisfaction. The aim of this study was to compare tibial component rotation and its coverage on the tibial plateau achieved with curve-on-curve and tibial tuberosity techniques (t-t technique) with use of anatomic knee designs with asymmetric tibial baseplate. MATERIALS AND METHODS: A total of 88 patients were randomly assigned in a 1:1 ratio to undergo total knee arthroplasty with use of the PERSONA PS (Zimmer Biomet) knee design with an asymmetric baseplate. The rotation of the tibial component was assessed and performed with two different techniques: curve-on-curve technique and tibial tuberosity technique. Tibial component rotation was measured on computed tomography (CT) scans using the method suggested by Benazzo et al. and designed for asymmetrical implants. For the measurement of the tibial bone coverage, the component surface area was outlined and measured on a proper CT section, then the tibial cut surface area was outlined and measured on a section just below the cement level. Pre- and post-operative range of motion was measured by another independent researcher 12 months post-operatively during follow-up visit. RESULTS: There was a statistically significant difference between both groups in median value of tibial rotation angle: 7° (interquartile range (IQR) = 0-12) in curve-on-curve technique group vs 2° (IQR-1-7) in tibial tuberosity technique group, probability value (p) = 0.0041, with values above 0 meaning external rotation of the component. There was no statistically significant difference between both groups in terms of range of motion (ROM) with average values of 124.3° ± 13.0° for curve-on-curve technique and 125.6° ± 12.8° for t-t technique with p = 0.45. There was a statistically insignificant difference between both groups in terms of coverage percentage in slight favor for curve-on-curve technique (85.9 ± 4.2 vs 84.5 ± 4.8, p = 0.17). CONCLUSION: In this study, no difference between the groups in terms of tibial bone coverage and range of motion was proved, even though both techniques differed significantly with values of tibial rotation. Future studies should be focused on influence of specific values of tibial rotation on patient-reported outcomes and survivorship of anatomic knee implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
12.
Medicine (Baltimore) ; 101(42): e31107, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36281192

RESUMO

In every surgical subspecialty surgical site infection (SSI) or implant infections, although occur seldom, pose a threat to patients' health. Risk factors of such states is diabetes mellitus (DM), considered one of the most widespread health-related problems of the 21st century. Orthopedists perform big joint replacements that usually concern older adults and therefore often deal with patients suffering from comorbidities. DM is frequently one of them and can furthermore often remain underdiagnosed. The other risk for complication is a rapid beginning of the rehabilitation which starts on the day following the surgery. To eliminate the debilitating impact of DM and hypoglycemia on surgical patients, we aim to investigate the relationship between the glycemia values and the postoperative outcomes in certain periods of time in patients undergoing orthopedic surgeries. Participants meeting inclusion criteria will have inserted a glycemia measuring device (Dexcom G5, Inc., San Diego, CA) in the periods of time. First time it will take place 14 days prior to the surgery and right after the surgery for the second time for the period of another 14 days. All patients will undergo standard total knee arthroplasty or total hip arthroplasty procedures. Patients will be assessed preoperatively and 14 days, 1, 3, 6, 12, and 24 months postoperatively. The assessment of the joint condition will consist of: patient-reported outcomes (The Knee injury and Osteoarthritis Outcome Score, Harris Hip Score, the Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]); assessment of potential SSI and cardiovascular complications (the Finnish Diabetes Risk Score [FINDRISC], the Systematic Coronary Risk Evaluation [SCORE]) and the clinical examination. To investigate the influence of orthopedic surgery (anesthesia) on glycemia and the significance and safety of early patients mobilization after the big joints surgeries. To investigate changes of glycemia in patients with normal glycemia metabolism, potentially protecting them from hypoglycemia during hospital stay and increasing their awareness of potential development of DM in the future. Additionally, this study will correlate perioperative glycemic levels with risk of cardiovascular events in one year follow-up, and its influence on SSI and implant complications.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Hipoglicemia , Osteoartrite , Idoso , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Hipoglicemia/etiologia , Estudos Observacionais como Assunto , Osteoartrite/etiologia , Período Pós-Operatório , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento
13.
Colloids Surf B Biointerfaces ; 218: 112749, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35932556

RESUMO

This paper reports the effects of rhamnolipids presence in the alginate hydrogel and CO32- solution, on the precipitation of CaCO3 in the Ca2+ loaded alginate hydrogel. Characteristics of the formed particles are discussed. Model conditions containing alginate hydrogel and rhamnolipids were used in order to mimic the natural environment of biomineralization in biofilms. It has been shown that rhamnolipids affect the characteristics of precipitated calcium carbonate effect of using these biosurfactants depends on their concentration as well as whether they are directly present in the hydrogel matrix or the carbonate solution surrounding the hydrogel. The greatest effect compared to the control samples was found for the rhamnolipids in the form of micelles directly present in the hydrogel with the CaCl2 cross-linked solution at concentration of 0.05 M. These conditions result in the highest increase in vaterite content, specific surface area, and pore volume. The mechanism of CaCO3 precipitation in alginate hydrogel containing rhamnolipids has been proposed.


Assuntos
Alginatos , Hidrogéis , Biomineralização , Carbonato de Cálcio , Cloreto de Cálcio , Glicolipídeos , Micelas
14.
Materials (Basel) ; 15(6)2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35329720

RESUMO

In this paper, the structural properties and the electrical conductivity of La1-xPrxNbO4+δ (x = 0.00, 0.05, 0.1, 0.15, 0.2, 0.3) and PrNbO4+δ are presented and discussed. All synthesized samples crystallized in a monoclinic structure with similar thermal expansion coefficients. The phase transition temperature between the monoclinic and tetragonal structure increases with increasing praseodymium content from 500 °C for undoped LaNbO4+δ to 700 °C for PrNbO4+δ. Thermogravimetry, along with X-ray photoelectron spectroscopy, confirmed a mixed 3+/4+ oxidation state of praseodymium. All studied materials, in humid air, exhibited mixed protonic, oxygen ionic and hole conductivity. The highest total conductivity was measured in dry air at 700 °C for PrNbO4+δ, and its value was 1.4 × 10-3 S/cm.

15.
Materials (Basel) ; 15(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35057350

RESUMO

Due to the rising concentration of toxic nitrogen oxides (NOx) in the air, effective methods of NOx removal have been extensively studied recently. In the present study, the first developed WO3/S-doped g-C3N4 nanocomposite was synthesized using a facile method to remove NOx in air efficiently. The photocatalytic tests performed in a newly designed continuous-flow photoreactor with an LED array and online monitored NO2 and NO system allowed the investigation of photocatalyst layers at the pilot scale. The WO3/S-doped-g-C3N4 nanocomposite, as well as single components, were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), Brunauer-Emmett-Teller surface area analysis (BET), X-ray fluorescence spectroscopy (XRF), X-ray photoemission spectroscopy method (XPS), UV-vis diffuse reflectance spectroscopy (DR/UV-vis), and photoluminescence spectroscopy with charge carriers' lifetime measurements. All materials exhibited high efficiency in photocatalytic NO2 conversion, and 100% was reached in less than 5 min of illumination under simulated solar light. The effect of process parameters in the experimental setup together with WO3/S-doped g-C3N4 photocatalysts was studied in detail. Finally, the stability of the composite was tested in five subsequent cycles of photocatalytic degradation. The WO3/S-doped g-C3N4 was stable in time and did not undergo deactivation due to the blocking of active sites on the photocatalyst's surface.

16.
Beilstein J Nanotechnol ; 12: 1271-1278, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34900508

RESUMO

In this work we study the luminescence properties of europium-doped titanium dioxide and tellurium oxide thin films enhanced by gold plasmonic nanostructures. We propose a new type of plasmon structure with an ultrathin dielectric film between plasmonic platform and luminescent material. Plasmonic platforms were manufactured through thermal annealing of the gold thin film. Thermal dewetting of gold film results in spherical gold nanostructures with average dimensions of 50 nm. Both, luminescent TiO2:Eu and TeO2:Eu films were deposited by RF magnetron sputtering from mosaic targets. The morphology of the gold nanostructures was investigated by SEM and TEM, while the composition of oxides film was analyzed by XPS. Luminescence properties were studied on the basis of excitation and emission spectra. The experiments show that the additional dielectric layer enhances the luminescence intensity. Such structures could be potential candidates as phosphors in white LEDs.

17.
Arthroplast Today ; 12: 62-67, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34765714

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is considered the most efficient treatment of end-stage osteoarthritis. There is an ongoing debate about proper implant designs and articulation types. One of the considered causes of unsatisfactory outcome and patients' dissatisfaction is femoral or tibial component overhanging, which can lead to chronic knee pain and restricted motion. The aim of this study is to compare radiological outcomes of TKA using an anatomic PERSONA Posterior-Stabilized (PS) knee design with its nonanatomic predecessor, the NexGen LPS. METHODS: A group of 39 patients who received the PERSONA PS system and 33 patients who received the NexGen LPS was included. PERSONA patients were matched to NexGen patients using a 0.1 propensity score threshold with priority given to exact matches. Anteroposterior, lateral, and long-leg radiographs were taken preoperatively and at 6 weeks postoperatively to perform radiological and statistical analysis. RESULTS: The PERSONA subgroup had statistically higher posterior condylar offset. There is no statistically significant difference in posterior condylar offset ratio. There were less cases of femoral notching, femoral overhang, and placing tibial baseplate in the medial overhang in the PERSONA PS subgroup than in the NexGen subgroup (each statistically significant). Occurrence of tibial underhang was not statistically significant. CONCLUSION: Radiological assessment in short-term follow-up showed excellent results for PERSONA knee design with better fit to native femur and tibia. In comparison to its predecessor, it also spares more bone tissue. As the aforementioned parameters are risk factors of lesser clinical outcomes, the PERSONA design gives high hopes for improvement of TKA satisfaction rate.

18.
Materials (Basel) ; 14(19)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34640082

RESUMO

In this work, for the first time, the influence of scaling up the process of titanium dioxide nanotube (TiO2NT) synthesis on the photoelectrochemical properties of TiO2 nanotubes is presented. Titanium dioxide nanotubes were obtained on substrates of various sizes: 2 × 2, 4 × 4, 5 × 5, 6 × 6, and 8 × 8 cm2. The electrode material was characterized using scanning electron microscopy as well as Raman and UV-vis spectroscopy in order to investigate their morphology, crystallinity, and absorbance ability, respectively. The obtained electrodes were used as photoanodes for the photoelectrochemical water splitting. The surface analysis was performed, and photocurrent values were determined depending on their place on the sample. Interestingly, the values of the obtained photocurrent densities in the center of each sample were similar and were about 80 µA·cm2. The results of our work show evidence of a significant contribution to wider applications of materials based on TiO2 nanotubes not only in photoelectrochemistry but also in medicine, supercapacitors, and sensors.

19.
Materials (Basel) ; 14(16)2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34443013

RESUMO

Glass-ceramics with the composition B2O3-Bi2O3-SrF2 were synthesized by the conventional melt-quenching technique and subsequent crystallization of the parental glasses. The temperature at which the ceramization was carried out was selected based on differential scanning calorimetry (DSC) analysis. The structure of the studied materials and the formation of SrF2 nanocrystals were confirmed by the Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) techniques. It was found that the amount of strontium fluoride introduced into the parental borate-bismuth glass has a significant impact on the growth of SrF2 nanocrystals. In particular, the influence of the crystalline SrF2 phase on luminescence intensity and kinetics was studied using Eu2O3-doped samples. An increase in luminescence intensity was observed in the samples in which SrF2 nanocrystals were formed. This is most likely related to the fact that some of the Eu3+ ions were (after annealing of the glass) located in the crystalline structure of strontium fluoride. This was confirmed both by the luminescence lifetime obtained based on the luminescence decay curves and the calculated Judd-Ofelt parameters, Ω2 and Ω4. The results achieved confirm that the glasses and glass-ceramics described in this work could be considered as a new phosphor for light-emitting diodes (LEDs).

20.
Materials (Basel) ; 14(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064192

RESUMO

Carbon nanotubes were successfully functionalized for the first time in a free radical phosphonylation reaction. Three synthetic protocols were proposed. Carbon nanotubes and diethylphosphite reacted in the presence of known radical initiator, such as azobisisobutyronitrile, single electron oxidant-Mn(OAc)3, or under UV radiation. The functionalized material was fully characterized by means of spectroscopic methods, together with microscopic, surface area and thermogravimetric analyses. UV-illumination was found to be the most effective approach for introducing phosphonates onto carbon nanotubes. X-ray photoelectron spectroscopy analysis showed 6% phosphorus in this sample. Moreover, the method was performed at room temperature for only one hour, using diethylphosphite as a reactant and as a solvent. The functionalized carbon nanotubes showed an improved thermal stability, with a decomposition onset temperature increase of more than 130 °C. This makes it very promising material for flame retarding applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...