Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Methods Cell Biol ; 187: 205-222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705625

RESUMO

Correlated super-resolution fluorescence microscopy and cryo-electron microscopy enables imaging with both high labeling specificity and high resolution. Naturally, combining two sophisticated imaging techniques within one workflow also introduces new requirements on hardware, such as the need for a super-resolution fluorescence capable microscope that can be used to image cryogenic samples. In this chapter, we describe the design and use of the "cryoscope"; a microscope designed for single-molecule localization microscopy (SMLM) of cryoEM samples that fits right into established cryoEM workflows. We demonstrate the results that can be achieved with our microscope by imaging fluorescently labeled vimentin, an intermediate filament, within U2OS cells grown on EM grids, and we provide detailed 3d models that encompass the entire design of the microscope.


Assuntos
Microscopia Crioeletrônica , Microscopia de Fluorescência , Microscopia de Fluorescência/métodos , Microscopia Crioeletrônica/métodos , Humanos , Vimentina/metabolismo , Imageamento Tridimensional/métodos , Imagem Individual de Molécula/métodos , Linhagem Celular Tumoral
2.
Methods Cell Biol ; 187: 223-248, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705626

RESUMO

Super-resolution cryo-correlative light and electron microscopy (SRcryoCLEM) is emerging as a powerful method to enable targeted in situ structural studies of biological samples. By combining the high specificity and localization accuracy of single-molecule localization microscopy (cryoSMLM) with the high resolution of cryo-electron tomography (cryoET), this method enables accurately targeted data acquisition and the observation and identification of biomolecules within their natural cellular context. Despite its potential, the adaptation of SRcryoCLEM has been hindered by the need for specialized equipment and expertise. In this chapter, we outline a workflow for cryoSMLM and cryoET-based SRcryoCLEM, and we demonstrate that, given the right tools, it is possible to incorporate cryoSMLM into an established cryoET workflow. Using Vimentin as an exemplary target of interest, we demonstrate all stages of an SRcryoCLEM experiment: performing cryoSMLM, targeting cryoET acquisition based on single-molecule localization maps, and correlation of cryoSMLM and cryoET datasets using scNodes, a software package dedicated to SRcryoCLEM. By showing how SRcryoCLEM enables the imaging of specific intracellular components in situ, we hope to facilitate adoption of the technique within the field of cryoEM.


Assuntos
Microscopia Crioeletrônica , Microscopia Crioeletrônica/métodos , Humanos , Imagem Individual de Molécula/métodos , Tomografia com Microscopia Eletrônica/métodos , Software , Processamento de Imagem Assistida por Computador/métodos , Vimentina/metabolismo , Animais
3.
J Struct Biol ; 215(4): 108040, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37918761

RESUMO

Correlated super-resolution cryo-fluorescence and cryo-electron microscopy (cryoEM) has been gaining popularity as a method to investigate biological samples with high resolution and specificity. A concern in this combined method (called SR-cryoCLEM), however, is whether and how fluorescence imaging prior to cryoEM acquisition is detrimental to sample integrity. In this report, we investigated the effect of high-dose laser light (405, 488, and 561 nm) irradiation on apoferritin samples prepared for cryoEM with excitation wavelengths commonly used in fluorescence microscopy, and compared these samples to controls that were kept in the dark. We found that laser illumination, of equal duration and intensity as used in cryo-single molecule localization microscopy (cryoSMLM) and in the presence of high concentrations of fluorescent protein, did not affect the achievable resolution in cryoEM, with final reconstructions reaching resolutions of âˆ¼ 1.8 Å regardless of the laser illumination. The finding that super-resolution fluorescence imaging of cryosamples prior to cryoEM data acquisition does not limit the achievable resolution suggests that super-resolution cryo-fluorescence microscopy and in situ structural biology using cryoEM are entirely compatible.


Assuntos
Biologia Molecular , Imagem Óptica , Microscopia Crioeletrônica/métodos , Microscopia de Fluorescência/métodos , Corantes
5.
Sci Rep ; 13(1): 8270, 2023 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-37217690

RESUMO

Cryogenic transmission electron microscopy (cryo-TEM) and super-resolution fluorescence microscopy are two popular and ever improving methods for high-resolution imaging of biological samples. In recent years, the combination of these two techniques into one correlated workflow has gained attention as a promising route towards contextualizing and enriching cryo-TEM imagery. A problem that is often encountered in the combination of these methods is that of light-induced damage to the sample during fluorescence imaging that renders the sample structure unsuitable for TEM imaging. In this paper, we describe how absorption of light by TEM sample support grids leads to sample damage, and we systematically explore the importance of parameters of grid design. We explain how, by changing the grid geometry and materials, one can increase the maximum illumination power density in fluorescence microscopy by up to an order of magnitude. Finally, we demonstrate the significant improvements in super-resolution image quality that are enabled by the selection of support grids that are optimally suited for correlated cryo-microscopy.

6.
J Struct Biol ; 215(2): 107965, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37100102

RESUMO

In cryo-transmission electron microscopy (cryo-TEM), sample thickness is one of the most important parameters that governs image quality. When combining cryo-TEM with other imaging methods, such as light microscopy, measuring and controlling the sample thickness to ensure suitability of samples becomes even more critical due to the low throughput of such correlated imaging experiments. Here, we present a method to assess the sample thickness using reflected light microscopy and machine learning that can be used prior to TEM imaging of a sample. The method makes use of the thin-film interference effect that is observed when imaging narrow-band LED light sources reflected by thin samples. By training a neural network to translate such reflection images into maps of the underlying sample thickness, we are able to accurately predict the thickness of cryo-TEM samples using a light microscope. We exemplify our approach using mammalian cells grown on TEM grids, and demonstrate that the thickness predictions are highly similar to the measured sample thickness. The open-source software described herein, including the neural network and algorithms to generate training datasets, is freely available at github.com/bionanopatterning/thicknessprediction. With the recent development of in situ cellular structural biology using cryo-TEM, there is a need for fast and accurate assessment of sample thickness prior to high-resolution imaging. We anticipate that our method will improve the throughput of this assessment by providing an alternative method to screening using cryo-TEM. Furthermore, we demonstrate that our method can be incorporated into correlative imaging workflows to locate intracellular proteins at sites ideal for high-resolution cryo-TEM imaging.


Assuntos
Aprendizado de Máquina , Proteínas , Animais , Microscopia Eletrônica de Transmissão , Microscopia Crioeletrônica/métodos , Software , Mamíferos
7.
Elife ; 112022 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-36305590

RESUMO

Cryogenic electron tomography (cryo-ET) combined with subtomogram averaging, allows in situ visualization and structure determination of macromolecular complexes at subnanometre resolution. Cryogenic focused ion beam (cryo-FIB) micromachining is used to prepare a thin lamella-shaped sample out of a frozen-hydrated cell for cryo-ET imaging, but standard cryo-FIB fabrication is blind to the precise location of the structure or proteins of interest. Fluorescence-guided focused ion beam (FIB) milling at target locations requires multiple sample transfers prone to contamination, and relocation and registration accuracy is often insufficient for 3D targeting. Here, we present in situ fluorescence microscopy-guided FIB fabrication of a frozen-hydrated lamella to address this problem: we built a coincident three-beam cryogenic correlative microscope by retrofitting a compact cryogenic microcooler, custom positioning stage, and an inverted widefield fluorescence microscope (FM) on an existing FIB scanning electron microscope. We show FM controlled targeting at every milling step in the lamella fabrication process, validated with transmission electron microscope tomogram reconstructions of the target regions. The ability to check the lamella during and after the milling process results in a higher success rate in the fabrication process and will increase the throughput of fabrication for lamellae suitable for high-resolution imaging.


Assuntos
Tomografia com Microscopia Eletrônica , Elétrons , Microscopia Crioeletrônica/métodos , Tomografia com Microscopia Eletrônica/métodos , Microscopia de Fluorescência , Íons
8.
ACS Nano ; 14(4): 4487-4498, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32239914

RESUMO

Membraneless organelles formed by liquid-liquid phase separation are dynamic structures that are employed by cells to spatiotemporally regulate their interior. Indeed, complex coacervation-based phase separation is involved in a multitude of biological tasks ranging from photosynthesis to cell division to chromatin organization, and more. Here, we use an on-chip microfluidic method to control and study the formation of membraneless organelles within liposomes, using pH as the main control parameter. We show that a transmembrane proton flux that is created by a stepwise change in the external pH can readily bring about the coacervation of encapsulated components in a controlled manner. We employ this strategy to induce and study electrostatic as well as hydrophobic interactions between the coacervate and the lipid membrane. Electrostatic interactions using charged lipids efficiently recruit coacervates to the membrane and restrict their movement along the inner leaflet. Hydrophobic interactions via cholesterol-tagged RNA molecules provide even stronger interactions, causing coacervates to wet the membrane and affect the local lipid-membrane structure, reminiscent of coacervate-membrane interactions in cells. The presented technique of pH-triggered coacervation within cell-sized liposomes may find applications in synthetic cells and in studying biologically relevant phase separation reactions in a bottom-up manner.


Assuntos
Células Artificiais , Lipossomos , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Microfluídica
9.
Nat Commun ; 10(1): 1800, 2019 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-30996302

RESUMO

Liquid-liquid phase separation (LLPS), especially coacervation, plays a crucial role in cell biology, as it forms numerous membraneless organelles in cells. Coacervates play an indispensable role in regulating intracellular biochemistry, and their dysfunction is associated with several diseases. Understanding of the LLPS dynamics would greatly benefit from controlled in vitro assays that mimic cells. Here, we use a microfluidics-based methodology to form coacervates inside cell-sized (~10 µm) liposomes, allowing control over the dynamics. Protein-pore-mediated permeation of small molecules into liposomes triggers LLPS passively or via active mechanisms like enzymatic polymerization of nucleic acids. We demonstrate sequestration of proteins (FtsZ) and supramolecular assemblies (lipid vesicles), as well as the possibility to host metabolic reactions (ß-galactosidase activity) inside coacervates. This coacervate-in-liposome platform provides a versatile tool to understand intracellular phase behavior, and these hybrid systems will allow engineering complex pathways to reconstitute cellular functions and facilitate bottom-up creation of synthetic cells.


Assuntos
Células Artificiais/metabolismo , Permeabilidade da Membrana Celular , Lipossomos/metabolismo , Microfluídica/métodos , Células Artificiais/química , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Dispositivos Lab-On-A-Chip , Lipossomos/química , Microfluídica/instrumentação , Transição de Fase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...