Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Heliyon ; 10(9): e30668, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38774097

RESUMO

Objective: To analyse and continually improve existing issues in the quality improvement process of medical linear accelerators (LINACs) and enhance the quality control management of LINACs. Methods: Data were collected from eight LINACs (sourced from three manufacturers) at Zhejiang Cancer Hospital using Excel diaries between January 2019 and December 2020. The data description and analysis were performed using the analytic hierarchy process, SPSSAU and Excel software, and mean-time-to-repair (MTTR)/mean-time-between-failure (MTBF) metrics. Continuous quality improvement was executed using the quality control circle (QCC) quality management method. Results: After quality improvement, the risk frequency of 'LINAC down' events decreased by 43.63% and downtime was reduced by 40.45%. The weight of downtime risk improved by 73.69%. The MTTR recovery value increased by 31.90%, and MTBF reliability increased by 2.97 h. The simulation results demonstrated that the proposed quality improvement measures could effectively decrease the frequency and duration of downtimes, consequently extending the normal operational time of LINACs. Conclusion: Transitioning from instant repair to preventative maintenance can enhance the operational efficiency of equipment and yield economic benefits for hospitals. The QCC method and the event risk evaluation model are effective in reducing the downtime of LINACs and improving their quality control management.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(9): 2991-6, 2016 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-30085492

RESUMO

Blood constituent examination is an important means of health diagnosis. For blood constituent examination, we usually adopt the method of drawing blood, which bring pain and the risk of cross infection to the patient. Near infrared spectrum spectroscopy (NIRS) is a research hotspot in noninvasive blood constituent examination. The spectral data acquisition system of existing instruments is using a Single Chip Microcomputer (SCM) as its microcontroller. The spectral data acquisition system cannot realize the high speed multi-channel acquisition and storage of large amounts of data because of the SCM itself has certain deficiency. So a high speed multi-channel spectral data acquisition system based on Field Programmable Gate Array (FPGA) was designed in this paper in order to realize the system of high speed, multi-channel and high signal-to-noise ratio (SNR) in the area of noninvasive blood constituent examination by near infrared spectroscopy. An Altera Cyclone IV series FPGA was used as the microcontroller in this spectral data acquisition system, which simultaneously controlled two pieces of eight channels AD conversion chip acquiring 16 channels blood pulse wave signal parallel. Under the control of FPGA, the data was cached in FPGA internal ping-pong RAM first, after that it was transferred to an SRAM chip, finally it was sent to the computer via the USB port. Experiment result shows that the spectral data acquisition system can collect 16 channels signal parallel and fast under the sampling frequency of 19 531 Hz and the repetitive signal-to-noise ratio is over 40 000∶1. The system can collect 305 spectrograms per second, more over it can get high SNR human body blood pulse wave signal under the same circumstances. The spectral data acquisition system satisfies the basic requirements of the noninvasive blood constituent examination instrument by NIRS and it can make the instrument collect the human body blood pulse wave data at a high speed. The main innovation point of this article is applying FPGA to the spectral data acquisition system of near infrared noninvasive blood constituent examination instrument. FPGA is able to simultaneously control two pieces of eight channels AD conversion chip acquiring 16 channels blood pulse wave signal parallel. By using FPGA as the microcontroller of the spectral data acquisition system, we solve the problem that SCM as the microcontroller can't realize multi-channel high speed data acquisition and storage of large amounts of data. The acquisition speed is greatly faster than the system before. The second innovation point of this article is we use FPGA internal resources establish a ping-pong RAM buffer. The spectral data from the AD chip is 24 bit, however, the SRAM chip has only 16 bit data bus. Via the ping-pang RAM buffer, the spectral data can transfer from AD chip to SRAM chip. The ping-pong RAM can realize different digits data seamless transfer from AD chip to SRAM chip.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(4): 942-6, 2014 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-25007605

RESUMO

The present paper studies the best detector-distance to improve the near-infrared spectrum signal intensity of the dermis layer and eliminate the interference of the epidermis and subcutaneous layer. First, we analyzed the organizational structure of the skin and calculated the tissue optical parameters of different layers. And we established the Monte Carlo model with the example of glucose absorption peak at 2 270 nm. Then, we used the Monte Carlo method to simulate the light transmission rules in the skin, obtaining the average path length, the average visit depth and the fractions of absorbed energy at each layer with the change in critical angle and detector-distance. The results show that when the photons are incident at an angle less than 45 degrees, you can ignore the effect of the incident angle on photon transmission path, and when the detector-distance is 1 mm, the fraction of absorbed photon energy by the dermis layer is the largest, while it can ensure more energy received by detector. We determined that the best detector-distance is 1mm, which successfully avoids the interference of the epidermis spectral information and obtains large amounts of blood in the dermis layer, which is conducive to the near-infrared non-invasive measurement of biochemical components and the subsequent experiments.


Assuntos
Glucose/análise , Absorção Cutânea , Pele/anatomia & histologia , Espectroscopia de Luz Próxima ao Infravermelho , Modelos Teóricos , Método de Monte Carlo , Fótons
4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(5): 1406-10, 2013 May.
Artigo em Chinês | MEDLINE | ID: mdl-23905362

RESUMO

High signal-to-noise ratio (SNR) of system is necessary to obtain accurate blood components in near infrared noninvasive biochemical analysis. In order to improve SNR of analytical system, high-efficiency double compound parabolic concentrator (DCPC) system was researched, which was aimed at increasing light utilization efficiency. Firstly, with the request of collection efficiency in near infrared noninvasive biochemical analysis, the characteristic of emergent rays through compound parabolic concentrator (CPC) was analyzed. Then the maximum focusing angle range of the first stage CPC was determined. Secondly, the light utilization efficiency of truncated type was compared with standard DCPC, thus the best structure parameters of DCPC system were optimized. Lastly, combined with optical parameters of skin tissue, calculations were operated when incident wavelength is 1 000 nm. The light utilization efficiency of DCPC system, CPC-focusing mirror system, and non-optical collecting system was calculated. The results show that the light utilization efficiency of the three optical systems is 1.46%, 0.84% and 0.26% respectively. So DCPC system enhances collecting ability for human diffuse reflection light, and helps improve SNR of noninvasive biochemical analysis system and overall analysis accuracy effectively.


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Calibragem , Desenho de Equipamento , Humanos , Fenômenos Ópticos , Pele/irrigação sanguínea
5.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(2): 349-53, 2013 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-23697109

RESUMO

To increase the signal-to-noise ratio (SNR) of human near infrared (NIR) spectra, so as to improve the stability and precision of calibration model, the empirical mode decomposition (EMD) method was applied. Eighty-one fingertip absorption curves were collected, with the corresponding clinical examination results obtained immediately. By means of outliers detection and removal, finally 78 samples were determined as the research objects. A three-layer back-propagation artificial neutron network (BP-ANN) model was established and worked for prediction. The results turned out that, through EMD method, the prediction correlation coefficient increased greatly from 0.74 to 0.87. RMSEP was reduced from 12.85 to 8.08 g x L(-1). Other indexes were also obviously improved. The overall results sufficiently demonstrate that it is feasible to use EMD method forhigh SNR pulse wave signals, thus improving the performance of noninvasive hemoglobin calibration models. The application of EMD method can help promote the development of noninvasive hemoglobin monitoring technology.


Assuntos
Algoritmos , Hemoglobinas/análise , Processamento de Sinais Assistido por Computador , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Artefatos , Humanos , Redes Neurais de Computação
6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(11): 2983-8, 2013 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-24555365

RESUMO

Near-infrared spectroscopy (NIRS) is a reliable, rapid, and non-destructive analytical method widely applied in as a number of fields such as agriculture, food, chemical and oil industry. In order to suit different applications, near-infrared spectrometers are now varied. Portable near-infrared spectrometers are needed for rapid on-site identification and analysis. Instruments of this kind are rugged, compact and easy to be transported. In this paper, the current states of portable near-infrared spectrometers are reviewed. Portable near-infrared spectrometers are built of different monochromator systems: filter, grating, Fourier-transform methods, acousto-optic tunable filter (AOTF) and a large number of new methods based on micro-electro-mechanical systems (MEMS). The first part focuses on working principles of different monochromator systems. Advantages and disadvantages of different systems are also briefly mentioned. Descriptions of each method are given in turn. Typical spectrometers of each kind are introduced, and some parameters of these instruments are listed. In the next part we discuss sampling adapters, display, power supply and some other parts, which are designed to make the spectrometer more portable and easier to use. In the end, the current states of portable near-infrared spectrometers are summarized. Future trends of development of portable near-infrared spectrometers in China and abroad are discussed.


Assuntos
Óptica e Fotônica , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Agricultura , China
7.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(9): 2347-50, 2012 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-23240393

RESUMO

In noninvasive biochemical detection, the differential spectrum method based on the change in blood volume can eliminate the interference of human tissue background in theory, and obtain effective spectrum information of blood. In order to demonstrate the effectiveness of the differential spectrum method, simulated experiment was designed. Biological molecules solutions were used for simulating serum sample, filters with different absorption characteristic were used for simulating interference of tissue background, and an adjustable path-length cell was used for simulating blood volume change. Model accuracies of pre- and post-treatment with differential spectrum method were compared. Thus treated, the root mean square error of cross validation (RMSECV) reduced from 437 to 301 mg x dL(-1). The experimental results indicate that using the differential spectrum method can effectively restrain the interference of tissue background, and greatly improve the prediction precision of calibration model.


Assuntos
Análise Química do Sangue , Espectroscopia de Luz Próxima ao Infravermelho , Calibragem , Humanos , Modelos Teóricos
8.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(5): 1225-9, 2012 May.
Artigo em Chinês | MEDLINE | ID: mdl-22827059

RESUMO

To establish the on-line near infrared spectral correction model for the jujube quality of Southern Xinjiang, the main influence factors of online testing results were analyzed, and the corresponding parameters were studied. First of all, the collecting conditions of different jujube were set, such as measurement condition, spectral region, and the parameters of the apparatus. With near infrared spectrometer and self-designed jujube batch collecting attachment, the quality spectrum of jujube was obtained, and combining spectral preprocessing and detection precision, condition parameters were selected. Secondly, through PLS spectrum correction with different modeling parameters and two-dimensional correlation spectroscopy analysis, Brix characteristic spectral parameters were selected. The results showed that with sugar degree central wavelength 9116, 9 418 and 10,500 cm(-1), acquisition resolution 16 cm(-1), and scan number 8, the sugar degree relative error was 8%-10%, the size of single grain jujube spectra was reduced to 1/10 of the original, and the time was reduced to 3 seconds. It was concluded that with the experimental parameters, the spectra were compressed, a primary online correction model was established, and the jujube quality online detection with near infrared spectroscopy was basically realized.


Assuntos
Qualidade dos Alimentos , Espectroscopia de Luz Próxima ao Infravermelho , Ziziphus , Carboidratos/análise , Frutas , Modelos Teóricos
9.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(5): 1423-6, 2012 May.
Artigo em Chinês | MEDLINE | ID: mdl-22827105

RESUMO

The spectral subtraction approach with different flow blood volume in near infrared noninvasive biochemical sensing can eliminate human tissue background interference, but at the same time the pathlength of subtracted spectrum is unknown. Thus, the model will be insufficiently effective if established directly with pathlength-unknown spectra, which is a big problem for subtracted blood volume spectrometry. In the present paper, a simulated experiment was designed to simulate this issue. The orthogonal signal correction method was proposed to eliminate the influence brought by pathlength. Compared with the PLS model before and after orthogonal signal correction, the root mean square error of cross validation (RMSECV) was from 90.17 mg x dL(-1) down to 31.62 mg x dL(-1), and the correlation coefficient was improved from 0.9787 to 0.9968. The experimental results show that using the orthogonal signal correction method can effectively restrain the interference information of path-length, and improve the prediction precision of calibration model. The conclusion in this paper sets the stage for the practical application of the spectral subtraction approach with different flow blood volume.


Assuntos
Determinação do Volume Sanguíneo/métodos , Modelos Teóricos , Espectroscopia de Luz Próxima ao Infravermelho , Volume Sanguíneo , Calibragem , Humanos
10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(4): 930-3, 2012 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-22715755

RESUMO

In noninvasive blood glucose measurement, it is difficult to keep the contact area between skin and internal reflectance element uniform while the mid-infrared spectra of human skin are taken, and this would lead to path-length variations. To study the effect of path-length variations on PLSR calibration model, in the present paper, according to the correlation coefficients between path-lengths and glucose concentrations, two PLSR models were achieved respectively and RMSECV were 31.3 and 4.52 mg x dL(-1), RMSEP were 30.3 and 98.7 mg x dL(-1) for the validation set. The results show that the chance correlations between path-lengths and glucose concentrations will lead to calibration models with different accuracy and robustness. This is useful to improving the reliability of noninvasive measurement of blood glucose by mid-infrared spectroscopy.


Assuntos
Glicemia , Espectrofotometria Infravermelho , Calibragem , Humanos , Modelos Teóricos , Reprodutibilidade dos Testes , Pele
11.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(3): 655-9, 2012 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-22582626

RESUMO

In the present paper, both the physical characteristics and spectral signatures of southern Xinjiang jujube were studied. With the methods of repetitive adjustment and stepwise refinement, the analysis diagram of jujube quality subdivision and characteristic factors were obtained. In actual practice, the spectra repeatability and quality can be improved by setting an optimum acquisition parameter according to different experimental requirements. Through experiments the characteristic factors of crack browning, luster and compositions were obtained, which demonstrates a distinguishing downing characteristic spectral line at the wave number of 10 170 cm(-1). Through characteristic analysis of jujube NIR spectra, the correspondence between the jujube spectra and their qualities was established, which lays the foundation for jujube qualities' characteristic coding in the future. The application of near-infrared topology method in the quality analysis of southern Xinjiang jujube is cost saving, which has a broad application prospect in establishing the NIR analytical standard and model database sharing of the jujube's quality in the future.


Assuntos
Qualidade dos Alimentos , Espectroscopia de Luz Próxima ao Infravermelho , Ziziphus/química , Frutas
12.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(1): 88-91, 2012 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-22497134

RESUMO

"Digital agriculture" or "precision agriculture" is an important direction of modern agriculture technique. It is the combination of the modern information technique and traditional agriculture and becomes a hotspot field in international agriculture research in recent years. As a nondestructive, real-time, effective and exact analysis technique, near infrared spectroscopy, by which precision agriculture could be carried out, has vast prospect in agrology and gradually gained the recognition. The present paper intends to review the basic theory of near infrared spectroscopy and its applications in the field of agrology, pointing out that the direction of NIR in agrology should based on portable NIR spectrograph in order to acquire qualitative or quantitative information from real-time measuring in field. In addition, NIRS could be combined with space remote sensing to macroscopically control the way crop is growing and the nutrition crops need, to change the current state of our country's agriculture radically.


Assuntos
Solo/química , Espectroscopia de Luz Próxima ao Infravermelho , Agricultura , Produtos Agrícolas
13.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(5): 1245-9, 2011 May.
Artigo em Chinês | MEDLINE | ID: mdl-21800574

RESUMO

Soil is the foundation of agricultural production. Rapid analysis of soil nutrients, using near infrared spectral analysis technology, can guide process of agricultural production. Developing near-infrared measuring system with discrete wavelength will change the extensive operation situation of agricultural production. First, the spectra of 85 black soil samples of northeast China, collected by FOSS XDS near-infrared spectrometer were analyzed using the correlation spectra and successive projection algorithm. Then, the characteristic wavelengths of total nitrogen and organic matter were obtained. After that the authors collected the spectra of soil samples using the measuring system with high signal to noise ratio (SNR) that the authors developed. The calibration models for total nitrogen and organic matter were established. The root mean square error of prediction (RMSEP) of total nitrogen and organic matter is 0.019% and 0.36% respectively, and the correlation coefficient of prediction (R(P)) is 0.851 and 0.923, respectively. Experimental results indicate that the characteristic wavelengths for total nitrogen and organic matter can be obtained through the near infrared spectra analyses. The measuring system can be used for soil nutrient analysis and lays the foundation for the industrial applications.

14.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(2): 375-8, 2011 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-21510384

RESUMO

To study rapid analysis of cholesterol concentration in human serum with no reagent, near-infrared spectroscopy was used. Applicability of analytical models was studied. Spectra of serum were measured by a FT-NIR spectrometer with 1, 2 and 6. 5 mm optical path length respectively. Partial least-square (PLS) models were calibrated for cholesterol in combination, first overtone and second overtone spectral regions. Root mean square error of prediction (RMSEP) of these models is 0.15, 0.16 and 0.29 mmol x L(-1), and mean percent error of prediction (MPEP) is 2.9%, 3.1% and 4.8%, respectively. To validate applicability of these models, other two groups of serum spectra were measured in one month after the models were calibrated. These two sample groups were calculated using calibrated models. Prediction result of 1 mm model is the best. The result of this experiment indicates that it's possible to calibrate precise models for cholesterol. If model is based on thinner samples, applicability is better.


Assuntos
Colesterol/sangue , Análise dos Mínimos Quadrados , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Humanos
15.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(8): 2107-10, 2010 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-20939317

RESUMO

In the early nineties of last century, great importance had been gradually attached to the potential of near-infrared spectroscopy (NIRS) in the human body noninvasive biochemical examination. However, the human body is extremely complex. Although research teams have made some achievements in experimental simulations and in-vitro analysis, there is still no substantive breakthrough in clinical application now. The present paper discusses the key problems which prevent NIRS from achieving human noninvasive clinical biochemical examination, such as weak signal, the interference of human tissue background and the problem of blood volume change. The thoughts of noninvasive biomedical examination using NIRS are divided into two categories in terms of analytical method, that is classical near-infrared analysis and issue background interference elimination analysis. This paper also introduces in detail the current status of the two categories in the world, and believes that the second category is more promising to be successful in clinical application under the existing conditions.


Assuntos
Diagnóstico por Imagem , Espectroscopia de Luz Próxima ao Infravermelho , Humanos
16.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(1): 50-3, 2010 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-20302079

RESUMO

Diabetes seriously endanger human health, and noninvasive glucose sensing is the expectation of both doctors and patients. Physiological background is complicated, volatile and mixed with a variety of tissue information, resulting in direct measurement of the body's near infrared spectra difficult to truly reflect the concentration change in glucose. As a matter of fact, blood volume is always changing, but human tissue background and the concentration of blood components are constant in a short period. Taking advantage of this, subtracted blood volume spectrometry is propounded, which could eliminate the interference of human tissue background and obtain effective spectrum information of blood. To verify the effectiveness of the method, a experimental system was developed. The system noise is better than 20 microAU, and the signal to noise ratio of the effective spectrum signal at 1250 nm is 20,000:1. Finally, the feasibility and advantages of subtracted blood volume spectrometry are clarified in clinical application of near infrared non-invasive glucose sensing.


Assuntos
Glicemia/análise , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Razão Sinal-Ruído
17.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(11): 2951-4, 2009 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-20101961

RESUMO

The present paper proposed how to select characteristic near-infrared wavelength for soil total nitrogen by using successive projection algorithm (SPA). Spectral data are compressed by SPA in the first place to obtain the raw wavelengths. Then the group of wavelengths derived from SPA is screened by their contributions to the total nitrogen. The insensitive wavelengths for total nitrogen are eliminated, improving the parsimony of the calibration model. For the 85 soil samples in total nitrogen, SPA was used to select the raw wavelengths. After screening on contribution, the number of wavelengths dropped from 12 by direct SPA to 6. Finally, the calibration model using wavelengths selected by screening on contribution after SPA showed the correlation coefficient (R(p)) of 0.913 and the root mean square error of prediction (RMSEP) of 0.011%. This model is as precise as the one before screening on contribution, and more precise than the result derived from partial least square (PLS) for the whole spectrum. The results demonstrate that the number of wavelengths selected by SPA can be reduced without significantly compromising prediction performance using the screening on contribution. The 6 selected total nitrogen wavelengths in this paper can be a reference for designing smart filter NIR spectrometer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...