Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38676226

RESUMO

Advanced light sources in the blue-green band are crucial for underwater wireless optical communication (UWOC) systems. Vertical-external-cavity surface-emitting lasers (VECSELs) can produce high output power and good beam quality, making them suitable for UWOC. This paper presents a 108 m distance UWOC based on a 100 mW 490 nm blue VECSEL and an acousto-optic modulator (AOM). The high-quality beam, which is near diffraction-limited, undergoes relatively small optical attenuation when using a conventional avalanche photodiode (APD) as the detector and employing 64-pulse position modulation (PPM). At the time-slot frequency of 50 MHz, the bit error rate (BER) of the UWOC was 2.7 × 10-5. This is the first reported AOM-based UWOC system with a transmission distance over 100 m. The estimated maximum transmission distance may be improved to about 180 m by fully utilizing the detection accuracy of the APD according to the measured attenuation coefficient of the blue VECSEL used. This type of UWOC system, composed of a high-beam-quality light source and a conventional detector, make it more closely suited to practical applications.

2.
Opt Express ; 27(5): 6389-6403, 2019 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-30876225

RESUMO

A cube-corner is employed as a photoelectric autocollimator's reflector to extend the angle measurement range and the corresponding algorithms are deduced. Experimental investigations reveal that the measurement range is extended from 1.2° to 12° without enlarging the objective lens's aperture. The accuracy is better than 35" when the deflection is less than 8°.

3.
Sensors (Basel) ; 15(4): 8527-39, 2015 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-25871721

RESUMO

Force producer is one of the core components of a Wire Suspended Micro-Pendulum Accelerometer; and the stability of permanent magnet in the force producer determines the consistency of the acceleration sensor's scale factor. For an assembled accelerometer; direct measurement of magnetic field strength is not a feasible option; as the magnetometer probe cannot be laid inside the micro-space of the sensor. This paper proposed an indirect measurement method of the remnant magnetization of Micro-Pendulum Accelerometer. The measurement is based on the working principle of the accelerometer; using the current output at several different scenarios to resolve the remnant magnetization of the permanent magnet. Iterative Least Squares algorithm was used for the adjustment of the data due to nonlinearity of this problem. The calculated remnant magnetization was 1.035 T. Compared to the true value; the error was less than 0.001 T. The proposed method provides an effective theoretical guidance for measuring the magnetic field of the Wire Suspended Micro-Pendulum Accelerometer; correcting the scale factor and temperature influence coefficients; etc.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...