1.
Clin Chem ; 47(9): 1627-32, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11514396

RESUMO

BACKGROUND: Measurement of porphobilinogen (PBG) is useful in the diagnosis of the acute neurologic porphyrias. Currently used colorimetric assays lack analytical and clinical sensitivity and specificity. METHODS: We developed a liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the measurement of PBG in 1 mL of urine, using 5-(aminoethyl)-4-(carboxymethyl) 1H-2,4-[(13)C]pyrolle-3-propanoic acid ([2,4-(13)C]PBG; 2.75 microg) as internal standard. After solid-phase extraction, LC-MS/MS analysis was performed in the selected-reaction monitoring (SRM) mode. PBG and [2,4-(13)C]PBG were monitored through their own precursor and product ion settings (m/z 227 to 210 and m/z 229 to 212, respectively). The retention time of PBG and [2,4-(13)C]PBG was 1.0 min in a 2.3-min analysis. RESULTS: Daily calibrations (n = 6) between 0.1 and 2.0 mg/L were linear and reproducible. Inter- and intraassay CVs were 3.2-3.5% and 2.6-3.1%, respectively, at mean concentrations of 0.24, 1.18, and 2.15 mg/L. The regression equation for the comparison between an anion-exchange column method (y) and the LC-MS/MS method (x) was: y = 0.84x + 0.74 (S(y/x) = 5.8 mg/24 h; r = 0.85; n = 100). In 47 volunteers, PBG excretion was 0.02-0.42 mg/24 h, lower than reported reference intervals (up to 2.0 mg/24 h) based on colorimetric methods. In 85 samples with PBG < or =0.5 by LC-MS/MS, 8 (9.4%) had values > or =2.0 mg/24 h by the anion-exchange method (mean +/- SD, 4.3 +/- 1.8 mg/24 h). In 11 patients with confirmed diagnoses of acute porphyria and increased PBG by LC-MS/MS, 2 had values within the reported reference intervals by a quantitative anion-exchange method. CONCLUSIONS: The quantitative LC-MS/MS method for PBG measurement exhibits greater analytical specificity and improved clinical sensitivity and specificity than currently available methods.


Assuntos
Porfobilinogênio/urina , Cromatografia Líquida , Humanos , Técnicas de Diluição do Indicador , Valores de Referência , Espectrometria de Massas por Ionização por Electrospray
2.
Pediatrics ; 108(1): E19, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11433098

RESUMO

Very long chain fatty acid dehydrogenase (VLCAD) deficiency is a rare but treatable cause of cardiomyopathy, fatty liver, skeletal myopathy, pericardial effusions, ventricular arrhythmias, and sudden death. Unrecognized, VLCAD deficiency may be rapidly progressive and fatal, secondary to its cardiac involvement. Because early diagnosis improves outcome, we present a neonate with VLCAD deficiency in whom retrospective analysis of the newborn screening card revealed that a correct diagnosis could have been made by newborn screening using tandem mass spectrometry. Our patient demonstrated a classic neonatal course with transient hypoglycemia at birth, interpreted as culture-negative sepsis, followed by a quiescent period notable only for hypotonia and poor feeding. At 3 months, he presented with cardiorespiratory failure and pericardial effusions, requiring pericardiocentesis, tracheostomy, and prolonged mechanical ventilation. Plasma free-fatty acid and acylcarnitine profiles demonstrated small but significant elevations of C14:2, C14:1, C16, and C18:1 acylcarnitine species, findings consistent with a biochemical diagnosis of VLCAD deficiency. Enteral feeds were changed to Portagen formula with marked improvement in cardiac symptoms over several weeks. To confirm the biochemical diagnosis, molecular analysis was performed by analysis of genomic DNA on a blood sample of the patient. Sequencing analysis and delineation of VLCAD mutations were performed using polymerase chain reaction and genomic sequencing. The patient was heterozygous for 2 different disease-causing mutations at the VLCAD locus. The maternal mutation was a deletion of bp 842-3 in exon 8, causing a shift in the reading frame. The paternal mutation was G+1A in the consensus donor splice site after exon 1; this splice-site mutation would likely result in decreased mRNA. The likely consequence of these mutations is essentially a null phenotype. To determine whether this case could have been picked up by tandem mass spectrometry analysis at birth when the patient was asymptomatic, acylcarnitine analysis was performed on the patient's original newborn card (after obtaining parental consent, the original specimen was provided courtesy of Dr Kenneth Pass, Director, New York State Newborn Screening Program). The blood sample had been obtained at 1 week of age and stored at room temperature for 6 months and at 70 degrees C thereafter for 18 months. Electrospray tandem mass spectrometry used a LC-MS/MS API 2000 operated in ion evaporation mode with the TurboIonSpray ionization probe source. The acylcarnitine profile obtained from the patient's original newborn card was analyzed 2 years after it was obtained. In comparison with a normal control, there was a significant accumulation of long chain acylcarnitine species, with a prominent peak of tetradecenoylcarnitine (C14:1), the most characteristic metabolic marker of VLCAD deficiency. This profile would have likely been even more significant if it had been analyzed at the time of collection, yet 2 years later is sufficient to provide strong biochemical evidence of the underlying disorder. Discussion. VLCAD was first discovered in 1992, and clinical experience with VLCAD deficiency has been accumulating rapidly. Indeed, the patients originally diagnosed with long chain acyl-CoA deficiency suffer instead from VLCAD deficiency. The phenotype of VLCAD deficiency is heterogeneous, ranging from catastrophic metabolic and cardiac failure in infancy to mild hypoketotic, hypoglycemia, and exertional rhabdomyolysis in adults. This case demonstrates that VLCAD deficiency could have been detected from the patient's own neonatal heel-stick sample. Most likely, a presymptomatic diagnosis would have avoided at least part of a lengthy and intensive prediagnosis hospitalization that had an estimated cost of $400 000. Although VLCAD is relatively rare, timely and correct diagnosis leads to dramatic recovery, so that detection by newborn screening could prevent the onset of arrhythmias, heart failure, metabolic insufficiency, and death. Fatty acid oxidation defects, including VLCAD deficiency, may account for as many as 5% of sudden infant death patients. Recent instrumentation advances have made automated tandem mass spectrometry of routine neonatal heel-stick samples technically feasible. Pilot studies have demonstrated an incidence of fatty acid oxidation defects, including short chain, medium chain, and very long chain acyl-CoA dehydrogenase deficiencies, of approximately 1/12 000. As a result, cost-benefit ratios for this approach should be systematically examined.


Assuntos
Acil-CoA Desidrogenase de Cadeia Longa/deficiência , Erros de Diagnóstico , Erros Inatos do Metabolismo/complicações , Erros Inatos do Metabolismo/diagnóstico , Mutação , Diagnóstico Diferencial , Hepatomegalia/genética , Humanos , Lactente , Recém-Nascido , Masculino , Erros Inatos do Metabolismo/genética , Erros Inatos do Metabolismo/metabolismo , Reflexo Anormal/genética , Análise de Sequência de DNA
3.
Mol Genet Metab ; 73(1): 38-45, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11350181

RESUMO

We have developed a capillary gas chromatography-electron-capture negative-ion mass spectrometry (GC/MS) method for the quantitative determination of C8-C26 total fatty acids in plasma. Following hydrolysis, hexane extraction, and derivatization with pentafluorobenzyl bromide, fatty acid esters are analyzed in two steps: a splitless injection and a second, split injection (1:100) for the quantitation of the more abundant long-chain species. Fourteen saturated and 25 unsaturated fatty acids are quantified by selected ion monitoring in ratio to 13 stable-isotope-labeled internal standards. Calibrations exhibit consistent linearity and reproducibility. Intraassay (n = 17) and interassay (n = 12) CVs ranged from 2.5 to 13.2% and from 4.6 to 22.9%, respectively. Recoveries ranged from 76 to 106%. Reference ranges were established for four age groups (<1 month, 1 month to 1 year, 1-17 years, >18 years) and compared to specimens from patients with nutritional deficiency of omega-3 and omega-6 polyunsaturated fatty acids, inborn errors of mitochondrial fatty acid oxidation, and peroxisomal disorders. Retrospective evaluation of the concentration of linoleic acid in 35 cases with a diagnosis of essential fatty acid deficiency previously made by gas chromatographic analysis with flame ionization detection (GC/FID) found a specificity and sensitivity of only 55 and 50%, respectively, for the GC/FID method when compared to GC/MS.


Assuntos
Ácidos Graxos/sangue , Doenças Metabólicas/sangue , Distúrbios Nutricionais/sangue , Adolescente , Transporte Biológico , Criança , Pré-Escolar , Ácidos Graxos/metabolismo , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Lactente , Recém-Nascido , Doenças Metabólicas/diagnóstico , Mitocôndrias/metabolismo , Mitocôndrias/patologia , Distúrbios Nutricionais/diagnóstico , Oxirredução , Valores de Referência
4.
Ann Clin Lab Sci ; 31(2): 199-204, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11337910

RESUMO

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to measure 6 metabolic compounds of the adrenocorticosteroid pathway simultaneously on residual specimens from patients who had previously been previously diagnosed, on the basis of immunoassays, as having congenital adrenal hyperplasia (CAH), 11 beta-hydroxylase deficiency, 21-hydroxylase deficiency, or Addison disease (adrenal insufficiency). Two subjects with normal adrenal function had serum cortisol values of 13.6 and 8.9 micrograms/dL and serum cortisone values of 2.1 and 0.6 microgram/dL, but the rest of the compounds were undetectable. Two patients with 11 beta-hydroxylase deficiency had serum 11 beta-deoxycortisol values of 14.9 and 10.0 micrograms/dL and serum 11-deoxycorticosterone values of 3.9 and 1.0 microgram/dL, but their serum levels of cortisol and cortisone were diminished. A patient with 21-hydroxylase deficiency had a highly increased serum 17-hydroxyprogesterone concentration of 28.5 micrograms/dL (or 28,500 ng/dL, the traditional unit to report this assay) and a serum 21-deoxycortisol concentration of 6.9 ug/dL (this is a pathologic marker of 21-hydroxylase deficiency that is nondetectable in sera of healthy subjects). This patient also had diminished concentrations of serum cortisol and cortisone (0.9 and 0.3 microgram/dL, respectively). At 30 and 60 min after corticotropin (ACTH) stimulation, serum cortisol was the only compound that showed a dramatic increase in the normal subjects; the patient with 21-hydroxylase deficiency showed an increase of serum 17-hydroxyprogesterone level, but no increase of serum cortisol level; the patient with Addison disease showed no increase in the levels of serum cortisol or other compounds. Metyprapone, which blocks 11 beta-hydroxylase activity, increased the serum 11-deoxycorticosteroid levels and decreased the serum cortisol level. This pilot study demonstrates that it is feasible to use LC-MS/MS for the laboratory diagnosis of adrenal cortical dysfunction. The authors envision that LC-MS/MS may soon become an ideal analytical technique for the diagnosis of such endocrine diseases.


Assuntos
Doenças do Córtex Suprarrenal/diagnóstico , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , 17-alfa-Hidroxiprogesterona/sangue , Doença de Addison/sangue , Doença de Addison/diagnóstico , Doenças do Córtex Suprarrenal/sangue , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Hormônio Adrenocorticotrópico , Adulto , Idoso , Cortisona/sangue , Cortodoxona/sangue , Desoxicorticosterona/sangue , Feminino , Humanos , Hidrocortisona/sangue , Masculino , Metirapona , Pessoa de Meia-Idade
5.
J Nutr ; 131(5): 1615S-20S, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11340127

RESUMO

Beginning in the mid 1960s, mass spectrometry was introduced in a few academic laboratories for the analysis of organic acids by gas chromatography-mass spectrometry. Since then, multiple-stage mass spectrometers have become available and many new applications have been developed. Major advantages of these new techniques include their ability to rapidly determine many different compounds in complex biological matrices with high sensitivity and in sample volumes of usually < 100 microL. A high sample throughput is further realized because extensive sample preparations are often not necessary. However, because the technical know-how is not yet widely available and significant experience is required for correct interpretation of results, these methods are being implemented slowly in routine clinical laboratories as opposed to research laboratories. Several of these new applications are considered with regard to clinical medicine.


Assuntos
Deficiência de Vitaminas/diagnóstico , Espectrometria de Massas , Erros Inatos do Metabolismo/diagnóstico , Humanos , Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Espectrometria de Massas/tendências , Erros Inatos do Metabolismo/sangue
6.
Clin Chim Acta ; 306(1-2): 35-41, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11282092

RESUMO

We have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of homovanillic acid (HVA), a biochemical marker for catecholamine and neurotransmitter metabolism. Urine specimens are spiked with 5 microg of a stable-isotope labeled internal standard, 13C(6)18O-HVA, and prepared by automated solid phase extraction. Residues were dissolved in acetonitrile: 0.05% aqueous acetic acid and analyzed by MS/MS in the selected reaction monitoring mode (HVA: m/z 181 to m/z 137; 13C(6)18O-HVA: m/z 189 to m/z 145) after separation using a Discovery RP Amide C16 column. Consecutive calibrations (n=7) between 0.52 and 16.7 mg/l exhibited consistent linearity and reproducibility. At a urine concentration of 0.51 mg/l, the signal-to-noise ratio for HVA was 21:1. Inter- and intra-assay CVs ranged from 0.3% to 11.4%, at mean concentrations ranging 1.8 to 22.7 mg/l. Recovery of HVA added to urine ranged between 94.7% and 105% (1.25 mg/l added), 92.0% and 102% (5.0 mg/l), and 96.0% and 104% (10 mg/l). LC-MS/MS is well suited to replace an HPLC method for routine HVA determination, by providing positive identification, faster turn around time, virtually no repeat analyses and a 44% reduction of personnel necessary to perform the testing.


Assuntos
Ácido Homovanílico/urina , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos , Isótopos , Padrões de Referência , Reprodutibilidade dos Testes
7.
Clin Chem ; 47(3): 513-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11238305

RESUMO

BACKGROUND: Congenital disorders of glycosylation (CDG) are autosomal recessive disorders that produce increased serum carbohydrate-deficient transferrin (CDT) isoforms. Methods to resolve CDT from fully glycosylated transferrin (Trf) have been based on a neutral shift in the isoelectric focusing (IEF) pattern or on a reduction in the negative charge, allowing resolution by anion-exchange chromatography. Our purpose was to develop a method of resolution and relative quantification of Trf isoforms using online immunoaffinity liquid chromatography-mass spectrometry (LC-MS). METHODS: Serum (25 microL) was diluted with 100 microL of water before application to an immunoaffinity column that sequestered Trf isoforms. Trf isoforms were eluted from the immunoaffinity column, concentrated on a C4 column, eluted from the C4 column, and introduced into the mass spectrometer. Analysis of the Trf isoforms was entirely automated and completed in <10 min per sample. RESULTS: The LC-MS method demonstrated that the major abnormal Trf isoforms in CDG lack one complete oligosaccharide structure (mono-oligosaccharide) or both oligosaccharide structures (a-oligosaccharide), but not the sialic acids, as presumed on the basis of IEF methods. Calculation of relative ratios among three possible species (mono-/di-oligosaccharide and a-/di-oligosaccharide) is reproducible [mean intra- and interassay CVs were 9.3% (n = 10) and 10% (n = 5), respectively]. A reference range for patients <18 years was determined by analysis of 209 samples (for mono-/di-oligosaccharide, the median was 0.041 and the range was 0.018-0.083; for a-/di-oligosaccharide, the median was 0.007 and the range was 0.002-0.036). Comparison of data obtained with an affinity chromatography-IEF method and the LC-MS method demonstrated equivalence in the interpreted results (n = 170). CONCLUSIONS: Advantages of the LC-MS method include improved sensitivity, minimal sample preparation, and an analysis time of <10 min. The method was automated, which allowed high throughput, with >100 samples analyzed in a single day. Moreover, the nature of the oligosaccharide defect in CDG is accurately reflected by mass resolution, and subtle oligosaccharide truncations may also be detected by this method.


Assuntos
Transferrina/análise , Animais , Anticorpos , Cromatografia Líquida/métodos , Humanos , Focalização Isoelétrica , Isoformas de Proteínas/sangue , Isoformas de Proteínas/imunologia , Coelhos , Valores de Referência , Espectrometria de Massas por Ionização por Electrospray , Transferrina/imunologia
8.
Clin Chem ; 46(11): 1804-10, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11067816

RESUMO

BACKGROUND: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization is robust and allows accurate measurement of both low- and high-molecular weight components of complex mixtures. We developed a LC-MS/MS method for the analysis of methylmalonic acid (MMA), a biochemical marker for inherited disorders of propionate metabolism and acquired vitamin B(12) deficiency. METHODS: We added 1 nmol of the internal standard MMA-d(3) to 500 microL of plasma or 100 microL of urine before solid-phase extraction. After elution with 18 mol/L formic acid, the eluate was evaporated, and butyl ester derivatives were prepared with 3 mol/L HCl in n-butanol at 65 degrees C for 15 min. For separation, we used a Supelcosil LC-18, 33 x 4.6 mm column with 60:40 (by volume) acetonitrile:aqueous formic acid (1 g/L) as mobile phase. The transitions m/z 231 to m/z 119 and m/z 234 to m/z 122 were used in the selected reaction monitoring mode for MMA and MMA-d(3,) respectively. The retention time of MMA was 2.2 min in a 3.0-min analysis, without interference of a physiologically more abundant isomer, succinic acid. RESULTS: Daily calibrations between 0.25 and 8.33 nmol in 0.5 mL exhibited consistent linearity and reproducibility. At a plasma concentration of 0.12 micromol/L, the signal-to-noise ratio for MMA was 40:1. The regression equation for our previous gas chromatography-mass spectrometry (GC-MS) method (y) and the LC-MS/MS method (x) was: y = 1.030 x -0.032 (S(y|x) = 1.03 micromol/L; n = 106; r = 0.994). Inter- and intraassay CVs were 3. 8-8.5% and 1.3-3.4%, respectively, at mean concentrations of 0.13, 0.25, 0.60, and 2.02 micromol/L. Mean recoveries of MMA added to plasma were 96.9% (0.25 micromol/L), 96.0% (0.60 micromol/L), and 94.8% (2.02 micromol/L). One MS/MS system used only overnight (7.5 h) replaced two GC-MS systems (30 instrument-hours/day) to run 100-150 samples per day, with reductions of total cost (supplies plus equipment), personnel, and instrument time of 59%, 14%, and 75%, respectively. CONCLUSIONS: This method is well suited for large-scale MMA testing (> or =100 samples per day) where a shorter analytical time is highly desirable. Reagents are less expensive than the anion-exchange/cyclohexanol-HCl method, and sample preparation of batches up to 100 specimens is completed in less than 8 h and is automated.


Assuntos
Ácido Metilmalônico/sangue , Ácido Metilmalônico/urina , Cromatografia Líquida , Deutério , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Técnicas de Diluição do Indicador , Espectrometria de Massas por Ionização por Electrospray
9.
Clin Chem ; 45(9): 1517-22, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10471655

RESUMO

BACKGROUND: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. METHODS: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 microL of either plasma or urine with homocystine-d(8) (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d(4) were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d(4) was 1.5 min in a 2.5-min analysis. RESULTS: Daily calibrations between 2.5 and 60 micromol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 micromol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x - 1.377 (r = 0.975; S(y|x) =1.595 micromol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; S(y|x) =1.146 micromol/L; n = 367). Inter- and intraassay CVs were 2.9-5.9% and 3.6-5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 micromol/L. Mean recovery of tHcy was 94.2% (20 micromol/L) and 97.8% (50 micromol/L). CONCLUSIONS: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.


Assuntos
Homocisteína/sangue , Homocisteína/urina , Cromatografia Líquida de Alta Pressão , Imunoensaio de Fluorescência por Polarização , Humanos , Espectrometria de Massas , Técnica de Diluição de Radioisótopos , Sensibilidade e Especificidade