1.
BMC Med Imaging ; 24(1): 130, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834987

RESUMO

In this study, we propose a novel method for quantifying tortuosity in 3D voxelized objects. As a shape characteristic, tortuosity has been widely recognized as a valuable feature in image analysis, particularly in the field of medical imaging. Our proposed method extends the two-dimensional approach of the Slope Chain Code (SCC) which creates a one-dimensional representation of curves. The utility of 3D tortuosity ( τ 3 D ) as a shape descriptor was investigated by characterizing brain structures. The results of the τ 3 D computation on the central sulcus and the main lobes revealed significant differences between Alzheimer's disease (AD) patients and control subjects, suggesting its potential as a biomarker for AD. We found a p < 0.05 for the left central sulcus and the four brain lobes.


Assuntos
Doença de Alzheimer , Encéfalo , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Encéfalo/diagnóstico por imagem , Feminino , Idoso , Masculino , Algoritmos , Imageamento por Ressonância Magnética/métodos , Estudos de Casos e Controles
2.
J Ultrasound Med ; 42(11): 2567-2582, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37490582

RESUMO

OBJECTIVES: Here we report on the intra- and inter-operator variability of the backscatter coefficient (BSC) estimated with a new low-variance quantitative ultrasound (QUS) approach applied to breast lesions in vivo. METHODS: Radiofrequency (RF) echo signals were acquired from 29 BIRADS 4 and 5 breast lesions in 2 sequential cohorts following 2 imaging protocols: cohort 1) radial and antiradial views, and cohort 2) short- and long-axis views. Protocol 2 was implemented after retraining and discussion on how to improve reproducibility. Each patient was scanned by at least 2 of 3 radiologists; each performed 3 acquisitions with transducer and patient repositioning in between acquisitions. BSC was estimated using a low-variance QUS approach based on regularization. Intra- and inter-operator variability of the intra-lesion median BSC was evaluated with a multifactorial ANOVA test (P-values) and the intraclass correlation coefficient (ICC). RESULTS: Inter-operator variability was only significant in the first protocol (P < .007); ICCinter = .77 (95% CI .71-.82), indicating good inter-operator agreement. In the second protocol, the inter-operator variability was not significant (P > .05) and agreement was excellent (ICCinter = .92 [.89-.94]). In both protocols, the intra-operator variability was not significant. CONCLUSIONS: Our findings demonstrate the need for standardizing image acquisition protocols for backscatter-based QUS to reduce inter-operator variability and ensure its successful translation to the characterization of suspicious breast masses.

3.
Neuroimage ; 207: 116343, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31734431

RESUMO

A voxel-based method for measuring sulcal width was developed, validated and applied to a database. This method (EDT-based LM) employs the 3D Euclidean Distance Transform (EDT) of the pial surface and a Local Maxima labeling algorithm. A computational phantom was designed to test method performance; results revealed the method's inaccuracy δ, to range between 0.1 and 0.5 voxels, for a width that varied between 1 and 7 voxels. Two morphological descriptors were computed to characterize each defined sulcus: mean sulcal width (MSW) and mean absolute deviation (MAD). The former is the average width for all available width measurements within the sulcus, and the latter is the deviation of these measurements. The EDT-based LM method was applied to the Minimal Interval Resonance Imaging in the Alzheimer's Disease (MIRIAD) database, for a set of high-resolution Magnetic Resonance (MR) images of 66 subjects: 43 patients with Alzheimer Disease (AD) and 23 control subjects. AD causes significant gray matter loss; hence, some sulci were expected to broaden. Methodological results concurred with this hypothesis. After a Wilcoxon test, MSW was grater in the case of all sulci pertaining to AD patients, (p < 0.05, FDR corrected), whereas MAD showed significant differences in 8 sulci (p < 0.05, FDR corrected). This work presents a novel voxel-based method for measuring sulcal width and extracting descriptors to characterize and compare the sulci within and across subjects.


Assuntos
Doença de Alzheimer/patologia , Doença de Alzheimer/fisiopatologia , Córtex Cerebral/patologia , Córtex Cerebral/fisiopatologia , Processamento de Imagem Assistida por Computador , Algoritmos , Mapeamento Encefálico , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino