Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Nucl Med ; 41(7): 1139-44, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10914902

RESUMO

UNLABELLED: Tissue attenuation results in nonuniform myocardial perfusion images with significant sex differences. New SPECT imaging protocols to correct attenuation are currently under investigation. This study was performed to assess the effects of attenuation correction (AC) on overall image uniformity compared with more conventional imaging protocols in both men and women. METHODS: Thirty-nine patients (19 men, 20 women) with less than a 5% likelihood of coronary artery disease were studied. (99m)Tc-sestamibi studies were acquired with a triple-head scanner equipped with a simultaneous transmission and emission protocol. Four imaging protocols were compared: a 180 degrees acquisition and filtered backprojection reconstruction (FBP), a 360 degrees acquisition and FBP, a 360 degrees acquisition and iterative reconstruction (IT), and a 360 degrees acquisition with IT and AC. Quantitative analysis was performed to evaluate myocardial tracer uniformity for men and women. RESULTS: 180 degrees, 360 degrees FBP, and 360 degrees IT showed sex differences, with decreased tracer concentration in the anterior wall in women and decreased tracer concentration in the inferior wall in men. AC images showed the greatest uniformity (9.9% coefficient of variation for AC versus 12.5% for IT, P < 0.0001), and no statistically significant differences in uniformity were seen between male and female AC studies. CONCLUSION: More uniform myocardial perfusion images were obtained with AC, resulting in images with no differences in uniformity between men and women. These techniques are expected to improve specificity and overall diagnostic accuracy.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Artefatos , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Fatores Sexuais , Tecnécio Tc 99m Sestamibi
2.
J Nucl Cardiol ; 6(3): 257-69, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10385181

RESUMO

BACKGROUND: Observer variability has been shown with interpretation of planar thallium-201 images. The interpretive reproducibility of technetium-99m sestamibi tomographic imaging is unknown. This study evaluated the interpretive reproducibility of interpretable Tc-99m sestamibi tomographic images among nuclear cardiologists with a wide range of training and experience. METHODS: Three experienced readers (EX) and 3 less-experienced readers (LEX) interpreted 138 exercise and rest Tc-99m sestamibi tomographic images (101 were abnormal in patients with coronary artery disease [CAD], 37 were normal in patients with <5% likelihood of CAD) twice in random sequence without clinical data. Images of good to excellent quality were randomly selected from a database at 2 nuclear cardiology laboratories. Intraobserver and interobserver agreement for global, left anterior descending (LAD) territory, non-LAD first (normal/abnormal) and second (normal/fixed/reversible) order, and defect extent (normal/single-vessel CAD/multi-vessel CAD) were assessed with percent agreement and Cohen's kappa (kappa) statistic. RESULTS: With regard to intraobserver agreement, first and second order ranged from 87% to 94% and 80% to 90% for global, 82% to 96% and 78% to 95% for LAD, and 88% to 91% and 80% to 90% for non-LAD, respectively. Defect extent ranged from 75% to 90%. There were no differences between EX and LEX for global and non-LAD first and second order, LAD first order, and defect extent. LAD second order was 93% for EX compared with 88% (P = .015) for LEX. With regard to interobserver agreement, first and second order ranged from 73% to 89% and 64% to 85% for global, 73% to 93% and 69% to 91% for LAD, and 76% to 88% and 68% to 84% for non-LAD, respectively. Defect extent ranged from 61% to 82%. Global first and second order ranged from 85% to 87% and 78% to 82% for EX compared with 73% to 84% and 64% to 79% for LEX. LAD first and second order ranged from 89% to 91% and 88% to 89% for EX compared with 73% to 91% and 69% to 70% for LEX. Non-LAD first and second order ranged from 82% to 86% and 76% to 77% for EX compared with 76% to 86% and 68% to 81% for LEX. Defect extent ranged from 69% to 75% for EX compared with 59% to 77% for LEX. CONCLUSIONS: There is moderate to excellent interpretive reproducibility with stress Tc-99m sestamibi SPECT imaging among nuclear cardiologists with a wide range of training and experience.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Circulação Coronária , Interpretação Estatística de Dados , Teste de Esforço , Humanos , Variações Dependentes do Observador , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi
3.
Rev Esp Cardiol ; 51 Suppl 1: 26-32, 1998.
Artigo em Espanhol | MEDLINE | ID: mdl-9549396

RESUMO

BACKGROUND: The aim of this study was to assess the effect of attenuation correction on gender differences in normals and to evaluate its effect on the size and severity of lateral wall perfusion defects in patients with circumflex artery disease. MATERIAL AND METHODS: Tomographic myocardial perfusion imaging with and without attenuation correction was performed on 32 patients with circumflex artery stenosis and compared with patients with less than 5% likelihood of coronary disease. Images were acquired with a triple headed scanner and reconstructed using an iterative algorithm and re-sliced in the short axis plane. Regional count densities were measured on selected short axis slices from the base to the apex in both patients and normals. RESULTS: All attenuation corrected images were found to be more uniform than the non attenuation corrected images on the patients with less than 5% likelihood of coronary artery disease. The coefficient of variation was 12.5% for non attenuation corrected images versus 9.9% for attenuation corrected images (p < 0.0001). When female and male segmental count distributions were compared, significant differences were found which were resolved after attenuation correction. In patients with circumflex artery stenosis, the anterolateral and lateral count densities were lower at all levels with attenuation corrected images with an increasing difference from base to apex. CONCLUSIONS: The use of attenuation correction results in a greater uniformity in normals and an improved estimation of extent and severity of perfusion defects in the territory of the circumflex artery.


Assuntos
Circulação Coronária , Doença das Coronárias/diagnóstico por imagem , Aumento da Imagem/métodos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
4.
Am J Cardiol ; 79(5): 600-5, 1997 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-9068516

RESUMO

Left ventricular (LV) cavity dilation during stress myocardial perfusion imaging has been associated with multivessel disease, and may be an independent prognostic marker in addition to perfusion defects. The present study examines the predictive value for future cardiac events of transient or fixed LV dilation during dipyridamole technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) imaging. The study included 512 consecutive patients who underwent SPECT imaging with Tc-99m sestamibi after dipyridamole infusion. Transient LV dilation was seen in 70 patients (14%) and 74 had fixed cavity dilation (14%); cavity size was normal in 368 patients (72%). Each perfusion scan was classified as normal or abnormal, and if abnormal, defects were categorized as transient or fixed, and as small, medium, or large (depending upon the number of abnormal vascular territories). Events during a mean follow-up of 12.8 +/- 6.8 months were tabulated by direct review of hospital charts and death certificates. The cardiac event rate (cardiac death or nonfatal infarction) was 1.9% in patients with normal cavity size, 11.4% with transient LV dilation, and 13.5% with fixed LV dilation (p < 0.01). Compared with patients with normal cavity size, those with transient LV dilation were more likely to sustain a myocardial infarction (p < 0.01) and those with fixed dilation more frequently suffered cardiac death (p < 0.01) and hospitalization for heart failure (p < 0.01). The group with the highest risk had both a large perfusion defect and cavity dilation. By Cox proportional hazard regression analysis, both transient and fixed LV dilation were strong independent predictors of cardiac events. Transient or fixed LV dilation are commonly seen during dipyridamole Tc-99m sestamibi SPECT imaging (14% incidence for each) and are useful predictors of cardiac events.


Assuntos
Dipiridamol , Cardiopatias/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores , Idoso , Baixo Débito Cardíaco/etiologia , Circulação Coronária , Doença das Coronárias/complicações , Vasos Coronários/diagnóstico por imagem , Morte Súbita Cardíaca/etiologia , Dilatação Patológica/complicações , Dilatação Patológica/diagnóstico por imagem , Dipiridamol/administração & dosagem , Feminino , Seguimentos , Previsões , Cardiopatias/complicações , Ventrículos do Coração/diagnóstico por imagem , Hospitalização , Humanos , Injeções Intravenosas , Masculino , Prognóstico , Modelos de Riscos Proporcionais , Compostos Radiofarmacêuticos/administração & dosagem , Estudos Retrospectivos , Fatores de Risco , Tecnécio Tc 99m Sestamibi/administração & dosagem , Vasodilatadores/administração & dosagem
6.
J Nucl Cardiol ; 3(2): 114-8, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8799236

RESUMO

BACKGROUND: To evaluate the effectiveness of published nuclear cardiology training guidelines, the diagnostic accuracy of image interpretation by nuclear cardiology trainees was compared with that of experienced nuclear cardiologists. METHODS AND RESULTS: The accuracy of three experienced nuclear cardiologists and three trainees with level II experience following Society of Nuclear Medicine/American College of Cardiology/American Society of Nuclear Cardiology guidelines in the interpretation of 114 exercise 99mTc-labeled sestamibi single-photon emission computed tomographic imaging studies was evaluated. Studies were selected randomly and included patients with less than 5% likelihood of coronary artery disease, as well as patients with angiographically demonstrated single and multivessel disease. Studies were interpreted by each reader without knowledge of clinical or exercise data. Each reader classified perfusion as normal or abnormal. Accuracy was assessed according to sensitivity, normalcy rate, and predictive accuracy. In addition, the ability of experienced readers and trainees to identify abnormal perfusion in patients with multivessel disease was compared. Trainees had high accuracy, comparable to experienced readers for sensitivity, normalcy rate, and predictive accuracy, as well as the ability to identify abnormal perfusion in patients with multivessel disease. In all categories, experienced interpretors demonstrated a trend toward greater accuracy with less observer variability than did trainees. CONCLUSION: Structured training in nuclear cardiology following Society of Nuclear Medicine/American College of Cardiology/American Society of Nuclear Cardiology guidelines during clinical cardiology fellowship is effective, and trainees possess the skills to interpret myocardial perfusion images accurately. Interpretive skills can be expected to improve further with experience.


Assuntos
Cardiologia/educação , Competência Clínica , Medicina Nuclear/educação , Doença das Coronárias/diagnóstico por imagem , Educação de Pós-Graduação em Medicina , Escolaridade , Teste de Esforço , Bolsas de Estudo , Guias como Assunto , Humanos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
7.
Cardiology ; 87(2): 134-40, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8653730

RESUMO

Single photon emission computed tomographic (SPECT) imaging with thallium-201 was evaluated in 492 consecutive, unselected patients to ascertain the patterns of use and additive value to the exercise electrocardiogram in the diagnosis of myocardial ischemia in a community hospital setting. Myocardial perfusion images were interpreted by a single observer employing visual and confirmatory quantitative analysis. The majority of patients (69%) were studied to evaluate the functional consequences of known coronary artery disease and not primarily to aid in diagnosis. Relationships among exercise electrocardiograms, SPECT information and coronary angiography were analyzed in 303 patients. The sensitivity was 92% and improved to 96% when multivessel disease was present. Overall, the positive predictive value of tomographic imaging in the detection of coronary disease was 94%. These findings demonstrate the changing pattern of use of myocardial perfusion imaging and confirm the value and applicability of this technique in routine clinical practice.


Assuntos
Angina Pectoris/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Teste de Esforço , Infarto do Miocárdio/diagnóstico por imagem , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/fisiopatologia , Angina Pectoris/cirurgia , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Angiografia Coronária , Ponte de Artéria Coronária , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Feminino , Seguimentos , Hospitais Comunitários , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Valor Preditivo dos Testes
8.
J Am Coll Cardiol ; 26(5): 1202-8, 1995 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-7594033

RESUMO

OBJECTIVES: This study sought to establish the prognostic value of intravenous dipyridamole technetium-99m (Tc-99m) sestamibi single-photon emission computed tomographic (SPECT) myocardial perfusion imaging. BACKGROUND: Optimal management of patients with coronary artery disease involves strategies designed to reduce the risk of myocardial infarction and cardiac death. The role of myocardial perfusion imaging using newer clinical techniques to determine risk and possible benefit from therapy has not been evaluated. METHODS: Myocardial imaging results were classified as normal or abnormal (fixed or reversible defects; small, moderate or large). Follow-up evaluation of all patients included the occurrence of cardiac death or nonfatal myocardial infarction and other cardiac-related hospital admissions. RESULTS: During a mean (+/- SD) follow-up period of 12.8 +/- 6.8 months in 512 patients, 25 had a cardiac event. Patients with abnormal perfusion had significantly more cardiac events than those with normal perfusion (22 vs. 3, p < 0.01). Patients with reversible defects had the highest event rates (8.6%), and those with normal study results had a very low event rate (1.4%). Large defects were strongly associated with more cardiac events and hospital admissions than either normal scan results or abnormal results showing small defects. CONCLUSIONS: Patients with normal study results or a small defect after intravenous dipyridamole Tc-99m sestamibi SPECT imaging had an excellent short-term prognosis. Those with abnormal results (reversible or large defect) had an increased risk of subsequent cardiac death, nonfatal myocardial infarction and other cardiac-related hospital admissions.


Assuntos
Dipiridamol , Cardiopatias/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Vasodilatadores , Adulto , Idoso , Idoso de 80 Anos ou mais , Dipiridamol/administração & dosagem , Feminino , Hospitalização , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Tomografia Computadorizada de Emissão , Vasodilatadores/administração & dosagem
9.
Clin Cardiol ; 17(5): 229-38, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-8004836

RESUMO

Risk stratification in patients with unstable angina is a major clinical problem with important therapeutic implications. Antiplatelet therapy is clearly effective in reducing the occurrence of myocardial infarction and death in this syndrome. Interventions including coronary bypass surgery and coronary angioplasty are frequently recommended for these patients, but the most appropriate application of these techniques needs to be further defined. After a brief discussion of the value of medical and interventional therapies, this review focuses on the clinical and noninvasive predictors of adverse events in unstable angina. An overall management strategy for these patients, based on current information, will be proposed.


Assuntos
Angina Instável/fisiopatologia , Angina Instável/terapia , Angina Instável/tratamento farmacológico , Angina Instável/cirurgia , Protocolos Clínicos , Humanos , Monitorização Fisiológica , Prognóstico , Fatores de Risco
10.
J Am Coll Cardiol ; 22(4): 1155-8, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7691911

RESUMO

OBJECTIVES: The effects of varying concentrations of theophylline on exercise-induced myocardial ischemia were evaluated in patients with stable coronary artery disease. BACKGROUND: Theophylline is a competitive antagonist of adenosine and may have potential as an anti-ischemic medication. It is not known whether these effects on myocardial ischemia are concentration dependent. METHODS: In a double-blind, randomized, crossover manner, 11 patients received, at 1-week intervals, placebo and each of three theophylline doses by intravenous infusion for 45 min. Graded exercise testing was performed before randomization and immediately after each infusion. Concurrent anti-ischemic medications were withheld for 24 h before each exercise test. Serum theophylline concentrations achieved were 3.9 +/- 1.0 mg/liter (low), 8.2 +/- 1.8 mg/liter (medium) and 13.2 +/- 2.3 mg/liter (high). RESULTS: Compared with placebo, none of the three theophylline infusions produced a significant alteration in rest heart rate, blood pressure, mean frequency or severity of ventricular ectopic activity or noncardiac symptoms. The time to onset of ischemia was progressively increased, with medium and high concentrations achieving statistical significance. Similar patterns were observed for oxygen uptake and the heart rate-systolic blood pressure product at the onset of ischemia. Total exercise duration was significantly prolonged with the medium and high concentrations. CONCLUSIONS: It is concluded that administration of varying doses of theophylline before exercise produces a clinically significant and concentration-dependent improvement in the indicators of myocardial ischemia in patients with chronic stable coronary artery disease.


Assuntos
Doença das Coronárias/complicações , Teste de Esforço , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/etiologia , Teofilina/farmacologia , Teofilina/uso terapêutico , Adenosina/antagonistas & inibidores , Idoso , Pressão Sanguínea/efeitos dos fármacos , Complexos Cardíacos Prematuros/complicações , Doença Crônica , Relação Dose-Resposta a Droga , Método Duplo-Cego , Frequência Cardíaca/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/metabolismo , Consumo de Oxigênio , Descanso , Sístole , Teofilina/sangue , Fatores de Tempo
12.
J Am Coll Cardiol ; 21(5): 1075-9, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8459060

RESUMO

OBJECTIVES: Theophylline has been shown to delay the onset of myocardial ischemia and to prolong exercise duration. The present study was done to evaluate the mechanisms and actions of intravenous theophylline on the onset of ischemia and exercise duration. BACKGROUND: The ischemic threshold may be altered by the differential coronary vasodilation induced by endogenous adenosine. Theophylline is a competitive receptor antagonist of adenosine and may have a potential as an anti-ischemic medication. METHODS: A double-blind, placebo-controlled crossover trial using an infusion of intravenous theophylline (8.0 +/- 2.0 mg/liter) or placebo before exercise in 12 patients was done. Oxygen uptake, heart rate, blood pressure and heart rate-blood pressure product were determined at the onset of > or = 0.1-mV ST segment depression and angina pectoris, as well as at peak exercise. The extent of myocardial ischemia was evaluated by electrocardiographic criteria and quantitation of thallium-201 images at peak exercise. RESULTS: When compared with placebo, theophylline significantly delayed time to the onset of exercise-induced ischemia. Ischemia occurred at a higher heart rate-blood pressure product and oxygen uptake. Exercise duration was prolonged but was not associated with greater ischemia, as determined by oxygen uptake, ST segment depression, angina pectoris and size of thallium-201 defect. CONCLUSIONS: It is concluded that theophylline favorably alters myocardial ischemia not only by delaying its onset but also by enabling it to occur at a higher threshold without causing deleterious effects during exercise. The mechanism for the increased ischemic threshold may be through the inhibition of adenosine and the coronary steal phenomenon.


Assuntos
Isquemia Miocárdica/tratamento farmacológico , Teofilina/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Método Duplo-Cego , Eletrocardiografia , Exercício Físico , Coração/diagnóstico por imagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/etiologia , Consumo de Oxigênio/efeitos dos fármacos , Cintilografia , Teofilina/administração & dosagem , Teofilina/farmacologia , Resultado do Tratamento
15.
J Thorac Cardiovasc Surg ; 71(3): 472-5, 1976 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-943032

RESUMO

Fungal endocarditis following prosthetic valve surgery has assumed increased importance as a cause of postoperative death. We present, to our knowledge, the first case of the fungus Paecilomyces varioti producing endocarditis on a prosthetic aortic valve. This seems to be an extremely indolent organism which exhibits an apparent response to antibiotic therapyl. In vitro evidence suggests that this fungus is sensitive to attainable serum levels of both 5-fluorocytosine and amphotericin B. However, after viewing the extracted valve and the devastating embolic phenomenon in our patient, we believe that medical therapy alone would not suffice. Thus we suggest that prompt valve replacement be performed in future cases.


Assuntos
Valva Aórtica/cirurgia , Endocardite/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Fungos Mitospóricos , Micoses/microbiologia , Insuficiência da Valva Aórtica/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Fungos Mitospóricos/patogenicidade , Trombose/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...