Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Opt Express ; 30(3): 3289-3301, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35209590

RESUMO

We present a theoretical overview and a proposed methodology which demonstrates SLASOPS (single laser asynchronous optical sampling) as a single-laser alternative to the conventional two-laser ASOPS technique. We propose the optical and electronic setup in which SLASOPS may be achieved experimentally with a single 2-section mode-locked laser diode as the pulsed-laser source and simulate how asynchronous optical sampling is generated and detected theoretically. We highlight the technique's ability to provide customizable scan ranges, scan rates and scan resolutions through variation of the imbalance in the interferometer arms and by tuning the repetition rate of the pulsed-laser source, which we present as optical cross-correlations between pulse pairs. We incorporate jitter into the system mathematically to assess the limitations on resolving both intensity and interferometric cross-correlation traces and to investigate the effects of averaging such traces in real-time. Analysis is then carried out on cross-correlation trace amplitude, width, and temporal positioning in order to discuss the technique's ability for deployment in typical optical sampling applications. In particular we note SLASOPS' ability to conduct asynchronous optical sampling using only a single laser, halving both the expense and technical requirements, doing so at megahertz scan rates, and within a spatial precision of just a few microns.

2.
Opt Express ; 24(8): 8370-81, 2016 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-27137274

RESUMO

We report on the first demonstration of absolute frequency comb metrology with an optical parametric oscillator (OPO) frequency comb. The synchronously-pumped OPO operated in the 1.5-µm spectral region and was referenced to an H-maser atomic clock. Using different techniques, we thoroughly characterized the frequency noise power spectral density (PSD) of the repetition rate frep, of the carrier-envelope offset frequency fCEO, and of an optical comb line νN. The comb mode optical linewidth at 1557 nm was determined to be ~70 kHz for an observation time of 1 s from the measured frequency noise PSD, and was limited by the stability of the microwave frequency standard available for the stabilization of the comb repetition rate. We achieved a tight lock of the carrier envelope offset frequency with only ~300 mrad residual integrated phase noise, which makes its contribution to the optical linewidth negligible. The OPO comb was used to measure the absolute optical frequency of a near-infrared laser whose second-harmonic component was locked to the F = 2→3 transition of the 87Rb D2 line at 780 nm, leading to a measured transition frequency of νRb = 384,228,115,346 ± 16 kHz. We performed the same measurement with a commercial fiber-laser comb operating in the 1.5-µm region. Both the OPO comb and the commercial fiber comb achieved similar performance. The measurement accuracy was limited by interferometric noise in the fibered setup of the Rb-stabilized laser.

3.
Opt Express ; 23(2): 1283-8, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835887

RESUMO

We present the first example of a femtosecond optical parametric oscillator frequency comb harmonically-pumped by a 333-MHz Ti:sapphire laser to achieve a stabilized signal comb at 1-GHz mode spacing in the 1.1-1.6-µm wavelength band. Simultaneous locking of the comb carrier-envelope-offset and repetition frequencies is achieved with uncertainties over 1 s of 0.27 Hz and 5 mHz respectively, which are comparable with those of 0.27 Hz and 1.5 mHz achieved for 333-MHz fundamental pumping. The phase-noise power-spectral density of the CEO frequency integrated from 1 Hz-64 kHz was 2.8 rad for the harmonic comb, 1.0 rad greater than for fundamental pumping. The results show that harmonic operation does not substantially compromise the frequency-stability of the comb, which is shown to be limited only by the Rb atomic frequency reference used.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...