Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Nucl Med Rev Cent East Eur ; 26(0): 123-129, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37786949

RESUMO

BACKGROUND: As a result of constantly improving surgical methods, an increasing number of patients have medical devices implanted in the cardiovascular system (including vascular grafts and endografts). Such patients are characterised by their high risk of infectious complications due to the possibility of biofilm formation on implanted material. This work aims to analyse the utility of 2-[18F]FDG PET/CT in diagnosing vascular graft and endograft infections. MATERIAL AND METHODS: The study was undertaken on a group of 58 patients, of whom 34 were in the study group, and 24 were in the control group. The 2-[18F]FDG PET/CT study was conducted in the Nuclear Medicine Department at the University Hospital of Lublin. The inclusion criteria for the study group were the presence of a vascular graft or endograft that encompasses the aorta, and strong clinical suspicion of its infection. The inclusion criteria for the control group were the presence of a vascular graft or endograft in the large arteries and the absence of signs of its infection on 2-[18F]FDG PET/CT, as well as the absence of clinically apparent signs and symptoms during six months of observation after 2-[18F]FDG PET/CT. All patients found in the database that met the criteria were included. RESULTS: Vascular endografts were more common in the control group than in the study group. However, in the case of infection of the vascular endograft, signs of infection in 2-[18F]FDG PET/CT were more severe. Images in the study group were divided into three groups that represent image patterns based on CT and PET characteristics. The first pattern (P1) was recognised in six patients. The second (P2) and third (P3) were visible in 11 and 17 patients, respectively. CONCLUSIONS: Comparative analysis of the study and control groups demonstrates the utility of 2-[18F]FDG PET/CT in the diagnosis of vascular graft/endograft infection.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos
2.
Nucl Med Rev Cent East Eur ; 23(2): 63-70, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33007092

RESUMO

BACKGROUND: 18F-FDG PET/CT has become an important tool in diagnosis of prosthetic vascular graft infections (PVGI). The aim of the study was to identify the patterns of vascular graft infection in 18F-FDG PET/CT. MATERIAL AND METHODS: The study was performed in 24 patients with vascular graft infection, in 17 patients implanted in an open surgery mode and in 7 patients by endovascular aortic repair (EVAR). Vascular prostheses were evaluated by two visual scales and semi-quantitative analysis with maximum standardized uptake values (SUV max). RESULTS: In the 3-point scale: 23 patients were in grade 1 and one patient was in grade 2. In the 5-point scale: 19 patients were in grade 5 with the highest activity in the focal area, 4 patients were in grade 4 and one patient in grade 3. The visual evaluation of 18F-FDG PET/CT study revealed that peri-graft high metabolic activity was associated with occurrence of morphological abnormalities (n = 21) like gas bubbles and peri-graft fluid retention or without abnormal CT findings (n = 3). The presence of the gas bubbles was linked to higher uptake of 18F-FDG (p < 0.01, SUVmax 11.81 ± 4.35 vs 7.36 ± 2.80, 15 vs 9 pts). In EVAR procedure, the highest metabolic activity was greater than in classical prosthesis (SUVmax 21.5 vs 13). CONCLUSIONS: 18F-FDG PET/CT is a very useful tool for assessment of vascular graft infections. CT findings like gas bubbles, or peri-graft fluid retention were associated with significantly higher glucose metabolism; however, in some cases without anatomic alterations, increased metabolic activity was the only sign of infection.


Assuntos
Prótese Vascular/efeitos adversos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...