Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 12(1): 8-13, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29195844

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being offered to high-risk patients with symptomatic aortic valve stenosis. Recent reports have suggested a high incidence of subclinical leaflet thrombosis following bioprosthestic aortic valve replacement. We report the frequency and clinical presentation of leaflet thrombosis identified by cardiac CT in patients referred for follow-up contrast enhanced CT angiography following TAVI. METHODS: 91 consecutive patients referred for follow-up contrast-enhanced CT angiography following TAVI were screened for inclusion in this analysis. Out of these, 13 patients were excluded. All CT examinations were performed using a 2nd or a 3rd generation dual-source system (Somatom Definition Flash/Force, Forchheim, Germany). In all patients, retrospectively ECG-gated spiral acquisition with tube modulation was performed to allow for assessment of leaflet motion. All prostheses were analyzed for presence of leaflet thrombosis defined as hypo-attenuated leaflet thickening with or without leaflet restriction. Post-procedural antithrombotic regimen as well as symptom status was documented in all patients. RESULTS: 78 consecutive patients (35 males, 81 ± 4 years) were analyzed. TAVI had been performed in all patients (76 transfemoral access, 2 transapical access) with either balloon-expandable prostheses (4 Sapien XT, 64 Sapien 3) or self-expandable prostheses (5 SJM Portico, 5 Symetis Acurate). Follow-up CT angiography was performed at a median of 4 months following index procedure (Interquartile range 1 month). Leaflet thrombosis was detected in 18 patients (23%, 14 Sapien 3, 1 Sapien XT, 2 SJM Portico, 1 Symetis Acurate). In patients with leaflet thickening on CT, only 11% were on either oral anticoagulation or new oral anticoagulants versus 50% for patients with no leaflet thickening (p 0.002). In patients with leaflet thrombosis, 3 leaflets were affected in 5 patients, 2 leaflets in 5 patients and in 8 patient only 1 leaflet was affected. Clinical symptoms (angina, dyspnea or both) were reported in 2/18 patients with leaflet thrombosis (11%) and in both patients a significant increase of the mean echocardiographic gradient over the prosthesis was documented. The peak and mean echocardiographic gradients obtained at the day of CT examination was significantly higher in symptomatic patients versus asymptomatic patients (peak 46 ± 7 vs. 23 ± 11 mmHg, mean 29 ± 7 vs. 12 ± 6 mmHg, p = 0.01 and 0.002, respectively). Follow-up CT was available for 4 patients with complete resolution of the hypo-attenuated leaflet thickening following treatment. CONCLUSION: Leaflet thrombosis following TAVI is a relatively frequent finding in patients referred for contrast enhanced CT angiography following TAVI. In the majority of patients it follows a subclinical course and is substantially more frequent in individuals who are not on oral anticoagulation. However, in patients with relevant increase in prosthetic gradients, symptomatic presentations are possible.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Trombose/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Fibrinolíticos/administração & dosagem , Alemanha/epidemiologia , Próteses Valvulares Cardíacas , Humanos , Incidência , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Trombose/epidemiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
2.
Eur Radiol ; 22(1): 51-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21845463

RESUMO

OBJECTIVES: Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. METHODS: 42 patients (82 ± 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. RESULTS: Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 ± 70 HU and 340 ± 77 HU. Aortic/iliac CNR was 21.7 ± 6.8 HU and 14.5 ± 5.4 HU using 100 kV (18.8 ± 4.1 HU and 8.7 ± 2.6 HU using 120 kV). Mean effective dose was 4.5 ± 1.2 mSv. CONCLUSIONS: High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Meios de Contraste/administração & dosagem , Angiografia Coronária , Implante de Prótese de Valva Cardíaca , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Artefatos , Índice de Massa Corporal , Cateterismo Cardíaco/métodos , Meios de Contraste/efeitos adversos , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Humanos , Artéria Ilíaca/patologia , Artéria Ilíaca/cirurgia , Masculino , Período Pré-Operatório , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes
3.
Eur J Radiol ; 72(1): 85-91, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18619752

RESUMO

OBJECTIVE: Assessment of left ventricular function is possible in contrast-enhanced cardiac CT data sets. However, rapid ventricular motion especially in systole can lead to artifacts. Dual Source Computed Tomography (DSCT) has high temporal resolution which effectively limits motion artifact. We therefore assessed the accuracy of DSCT to detect regional left ventricular wall motion abnormalities in comparison to invasive cine angiocardiography. METHODS: We analyzed DSCT data sets of 50 patients (39 male, 11 female, mean age: 61+/-10 years) which were acquired after intravenous injection of 55-70 mL contrast agent (rotation time: 330 ms, collimation: 2 mm x 64 mm x 0.6 mm, 120 kV, 380 mAs, ECG-correlated tube current modulation). 10 data sets consisting of transaxial slices with a slice thickness of 1.5 mm, an increment of 1.0 mm and a matrix of 256 x 256 pixels were reconstructed at 10 time instants during the cardiac cycle (0-90% in 10% increments). The data sets were analyzed visually by two independent readers, using standard left ventricular planes, concerning regional wall motion abnormalities. DSCT was verified in a blinded fashion against cine ventriculography performed during cardiac catheterization (RAO and LAO projection), using a 7-segment model. Analysis was performed on a per-patient (presence of at least one hypo-, a- or dyskinetic segment) and on a per-segment basis. RESULTS: Concerning the presence of a wall motion abnormality, the two observers agreed in 340/350 segments (97%) and 48/50 patients (96%). In invasive cine angiocardiography, 22 of 50 patients displayed at least one segment with abnormal contraction. To detect these patients, DSCT showed a sensitivity of 95% (21/22), specificity of 96% (27/28), positive predictive value of 95% and negative predictive value of 96%. Out of a total of 350 left ventricular segments, 66 segments had abnormal contraction in cine angiocardiography (34 hypokinetic, 26 akinetic, 6 dyskinetic). For detection of these segments, DSCT had a sensitivity of 88% (58/66), specificity of 98% (278/284), positive predictive value of 91% (58/64) and negative predictive value of 97% (278/286). CONCLUSION: DSCT allows the detection of regional wall motion abnormalities with high interobserver agreement as well as high sensitivity and specificity. Whereas sensitivity and positive predictive value were higher in a per-patient- in comparison to a per-segment-based analysis, specificity, negative predictive value and interobserver agreement did not differ considerably between both analyzing methods.


Assuntos
Angiocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
J Comput Assist Tomogr ; 25(4): 569-73, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11473187

RESUMO

PURPOSE: We conducted phantom studies to investigate whether overlapping cross-sections and volumetric scoring would significantly improve interscan reproducibility of electron beam tomography (EBT) for coronary artery calcium quantification. METHOD: Fifteen phantoms simulating various amounts of coronary calcification were scanned in five different positions with a slice thickness of 3.0 mm and a table feed of 3.0, 2.5, and 2.0 mm. For the conventional "Agatston score" and a "volume score" (total volume of calcified lesions), interscan variabilities were compared between the three image acquisition protocols. RESULTS: Agatston score variability was significantly lower for the 2.0 mm table feed than for the 3.0 or 2.5 mm table feed (3.0 mm: 22.9 +/- 10.3%; 2.5 mm: 13.6 +/- 8.2%; 2.0 mm: 8.9 +/- 5.5%). Volume score variability was significantly lower for 2.5 and 2.0 mm table feed than for 3.0 mm table feed (3.0 mm: 21.7 +/- 11.0%; 2.5 mm: 10.9 +/- 5.9%; 2.0 mm: 9.8 +/- 5.9%). CONCLUSION: Overlapping cross-sections, especially in combination with volumetric scoring, significantly improved interscan reproducibility of EBT calcium quantification in a phantom study.


Assuntos
Calcinose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/patologia , Cardiomiopatias/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
6.
Am J Cardiol ; 87(2): 210-3, A8, 2001 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-11152842

RESUMO

In 120 patients, the mean interscan variability of coronary calcium quantification by electron beam tomography was 19.9% (median 7.8%) for the traditional calcium score, and 16.2% (median 5.7%) for volumetric scoring. Although this difference was not significant, there was a significant influence of the total amount of calcium, number of acquired images, and image noise on interscan reproducibility.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Calcinose/patologia , Doença das Coronárias/patologia , Humanos , Masculino , Pessoa de Meia-Idade
7.
Heart ; 84(5): 489-93, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11040005

RESUMO

OBJECTIVE: To evaluate the accuracy of contrast enhanced electron beam computed tomography (EBCT) after acute myocardial infarction in determining patency of the infarct related artery and detecting high grade stenoses and occlusions in the coronary vessels. DESIGN: Case study using blinded comparison with invasive coronary angiography. PATIENTS: 36 patients (mean age 53 years) 4-70 days after acute myocardial infarction. INTERVENTIONS: The patients were studied by EBCT and invasive coronary angiography. For EBCT, 50 axial images of the heart (3 mm slice thickness) were acquired. They were triggered by the ECG during breath holding, after intravenous injection of contrast agent. The original images, surface reconstructions, and maximum intensity projections were evaluated for the presence of high grade stenoses and occlusions of the coronary arteries. MAIN OUTCOME MEASURES: EBCT results were compared with invasive coronary angiography. RESULTS: Of a total of 144 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 36 patients), 29 (20%) were unevaluable by EBCT. In the remaining arteries, 33 of 36 high grade lesions were correctly detected (92% sensitivity). Specificity was also 92% (73/79). Patency of the infarct related artery was correctly detected in 15 of 16 cases (94%). Five of the 14 occluded infarct related arteries (35%) were mistaken as stenotic but patent, and six could not be assessed. CONCLUSIONS: EBCT is very accurate in detecting significant coronary artery lesions in patients after acute myocardial infarction, but differentiation between occluded and patent infarct related arteries is currently unreliable.


Assuntos
Angiografia Coronária/métodos , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Meios de Contraste , Doença das Coronárias/diagnóstico por imagem , Elétrons , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Método Simples-Cego
8.
Radiology ; 216(2): 457-63, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10924570

RESUMO

PURPOSE: To determine the speed of and changes in the speed of coronary arterial movement during the cardiac cycle with electron-beam computed tomography (CT). MATERIALS AND METHODS: With electron-beam CT, 20 consecutive cross-sectional images were acquired at the mid right coronary artery (with 50-msec acquisition time, 8-msec intersection delay, 7-mm section thickness, and intravenous administration of 40 mL of contrast agent) in 25 patients. On the basis of the displacement of the left anterior descending, left circumflex, and right coronary arterial cross sections from image to image, movement velocity in the transverse imaging plane was calculated and was correlated with the simultaneously recorded electrocardiogram. RESULTS: The velocity of in-plane coronary arterial motion varied considerably during the cardiac cycle. Peaks were caused by ventricular systole and diastole and by atrial contraction. The mean velocity was 46.6 mm/sec +/- 12. 5 (SD). The mean velocity of right coronary arterial movement (69.5 mm/sec +/- 22.5) was significantly faster than that of the left anterior descending (22.4 mm/sec +/- 4.1) or the left circumflex coronary artery (48.4 mm/sec +/- 15.0). The lowest mean velocity (27. 9 mm/sec) was at 48% of the cardiac cycle. CONCLUSION: The lowest velocity of coronary arterial movement, which displays considerable temporal variation, was at 48% of the cardiac cycle.


Assuntos
Angiografia Coronária/métodos , Contração Miocárdica , Tomografia Computadorizada por Raios X/métodos , Idoso , Anatomia Transversal , Função Atrial/fisiologia , Meios de Contraste/administração & dosagem , Vasos Coronários/fisiologia , Diástole/fisiologia , Eletrocardiografia , Feminino , Humanos , Injeções Intravenosas , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Movimento , Intensificação de Imagem Radiográfica , Sístole , Função Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...