Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
bioRxiv ; 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39386574

RESUMO

The scarcity of human donor corneal graft tissue worldwide available for corneal transplantation necessitates the development of alternative therapeutic strategies for treating patients with corneal blindness. Corneal stromal stem cells (CSSCs) have the potential to address this global shortage by allowing a single donor cornea to treat multiple patients. To directly deliver CSSCs to corneal defects within an engineered biomatrix, we developed a UNIversal Orthogonal Network (UNION) collagen bioink that crosslinks in situ with a bioorthogonal, covalent chemistry. This cell-gel therapy is optically transparent, stable against contraction forces exerted by CSSCs, and permissive to the efficient growth of corneal epithelial cells. Furthermore, CSSCs remain viable within the UNION collagen gel precursor solution under standard storage and transportation conditions. This approach promoted corneal transparency and re-epithelialization in a rabbit anterior lamellar keratoplasty model, indicating that the UNION collagen bioink serves effectively as an in situ -forming, suture-free therapy for delivering CSSCs to corneal wounds. TEASER. Corneal stem cells are delivered within chemically crosslinked collagen as a transparent, regenerative biomaterial therapy.

2.
bioRxiv ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39345483

RESUMO

Hydrogels composed of collagen, the most abundant protein in the human body, are widely used as scaffolds for tissue engineering due to their ability to support cellular activity. However, collagen hydrogels with encapsulated cells often experience bulk contraction due to cell-generated forces, and conventional strategies to mitigate this undesired deformation often compromise either the fibrillar microstructure or cytocompatibility of the collagen. To support the spreading of encapsulated cells while preserving the structural integrity of the gels, we present an interpenetrating network (IPN) of two distinct collagen networks with different crosslinking mechanisms and microstructures. First, a physically self-assembled collagen network preserves the fibrillar microstructure and enables the spreading of encapsulated human corneal mesenchymal stromal cells. Second, an amorphous collagen network covalently crosslinked with bioorthogonal chemistry fills the voids between fibrils and stabilizes the gel against cell-induced contraction. This collagen IPN balances the biofunctionality of natural collagen with the stability of covalently crosslinked, engineered polymers. Taken together, these data represent a new avenue for maintaining both the fiber-induced spreading of cells and the structural integrity of collagen hydrogels by leveraging an IPN of fibrillar and amorphous collagen networks. Statement of significance: Collagen hydrogels are widely used as scaffolds for tissue engineering due to their support of cellular activity. However, collagen hydrogels often undergo undesired changes in size and shape due to cell-generated forces, and conventional strategies to mitigate this deformation typically compromise either the fibrillar microstructure or cytocompatibility of the collagen. In this study, we introduce an innovative interpenetrating network (IPN) that combines physically self-assembled, fibrillar collagen-ideal for promoting cell adhesion and spreading-with covalently crosslinked, amorphous collagen-ideal for enhancing bulk hydrogel stability. Our IPN design maintains the native fibrillar structure of collagen while significantly improving resistance against cell-induced contraction, providing a promising solution to enhance the performance and reliability of collagen hydrogels for tissue engineering applications.

3.
Sci Rep ; 14(1): 21806, 2024 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-39300144

RESUMO

Topical eye drop approaches to treat ocular inflammation in dry eyes often face limitations such as low efficiency and short duration of drug delivery. Nanofibers serve to overcome the limitation of the short duration of action of topical eye drops used against ocular inflammation in dry eyes. Several attempts to develop suitable nanofibers have been made; however, there is no ideal solution. Here, we developed polycaprolactone (PCL) nanofibers loaded with dexamethasone acetate (DEX), prepared by electrospinning, as a potential ocular drug delivery platform for corneal injury treatment. Thirty-nine Sprague Dawley rats (7 weeks old males) were divided into four treatment groups after alkaline burns of the cornea; negative control (no treatment group); dexamethasone eyedrops (DEX group); PCL fiber (PCL group); dexamethasone loaded PCL (PCL + DEX group). We evaluated therapeutic efficacy of PCL + DEX by examining the epithelial wound healing effect, the extent of corneal opacity and neovascularization. Additionally, various inflammatory factors, including IL-1ß, were investigated through immunochemistry, western blot analysis, and quantitative real-time RT-PCR (qRT-PCR). PCL + DEX group showed histologically alleviated signs of corneal inflammation compared with DEX group, which showed a decrease in IL-1ß and MMP9 in the corneal stroma. The quantitative expression on day 1 after alkaline burn of pro-inflammatory markers, including IL-1ß and IL-6, in the PCL + DEX group was significantly lower than that in the DEX group. Notably, PCL + DEX treatment significantly suppressed neovascularization, and enhanced the anti-inflammatory function of DEX during the acute phase of ocular inflammation. Collectively, these findings suggest that PCL + DEX may be a promising approach to effective drug delivery in corneal burn injuries.


Assuntos
Queimaduras Químicas , Dexametasona , Nanofibras , Poliésteres , Ratos Sprague-Dawley , Cicatrização , Animais , Dexametasona/farmacologia , Dexametasona/administração & dosagem , Dexametasona/análogos & derivados , Nanofibras/química , Poliésteres/química , Ratos , Queimaduras Químicas/tratamento farmacológico , Queimaduras Químicas/patologia , Masculino , Cicatrização/efeitos dos fármacos , Queimaduras Oculares/tratamento farmacológico , Queimaduras Oculares/patologia , Queimaduras Oculares/induzido quimicamente , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/administração & dosagem , Anti-Inflamatórios/química , Lesões da Córnea/tratamento farmacológico , Lesões da Córnea/patologia , Interleucina-1beta/metabolismo , Interleucina-1beta/genética , Metaloproteinase 9 da Matriz/metabolismo , Córnea/efeitos dos fármacos , Córnea/metabolismo , Córnea/patologia , Soluções Oftálmicas , Modelos Animais de Doenças
4.
ACS Nano ; 18(33): 21925-21938, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39106436

RESUMO

Corneal defects can lead to stromal scarring and vision loss, which is currently only treatable with a cadaveric corneal transplant. Although in situ-forming hydrogels have been shown to foster regeneration of the cornea in the setting of stromal defects, the cross-linking, biomechanical, and compositional parameters that optimize healing have not yet been established. This, Corneal defects are also almost universally inflamed, and their rapid closure without fibrosis are critical to preserving vision. Here, an in situ forming, bioorthogonally cross-linked, nanocluster (NC)-reinforced collagen and hyaluronic acid hydrogel (NCColHA hydrogel) with enhanced structural integrity and both pro-regenerative and anti-inflammatory effects was developed and tested within a corneal defect model in vivo. The NCs serve as bioorthogonal nanocross-linkers, providing higher cross-linking density than polymer-based alternatives. The NCs also serve as delivery vehicles for prednisolone (PRD) and the hepatocyte growth factor (HGF). NCColHA hydrogels rapidly gel within a few minutes upon administration and exhibit robust rheological properties, excellent transparency, and negligible swelling/deswelling behavior. The hydrogel's biocompatibility and capacity to support cell growth were assessed using primary human corneal epithelial cells. Re-epithelialization on the NCColHA hydrogel was clearly observed in rabbit eyes, both ex vivo and in vivo, with expression of normal epithelial biomarkers, including CD44, CK12, CK14, α-SMA, Tuj-1, and ZO-1, and stratified, multilayered morphology. The applied hydrogel maintained its structural integrity for at least 14 days and remodeled into a transparent stroma by 56 days.


Assuntos
Hidrogéis , Hidrogéis/química , Hidrogéis/farmacologia , Animais , Coelhos , Ácido Hialurônico/química , Ácido Hialurônico/farmacologia , Córnea/efeitos dos fármacos , Regeneração/efeitos dos fármacos , Humanos , Reagentes de Ligações Cruzadas/química , Colágeno/química , Fator de Crescimento de Hepatócito/farmacologia , Fator de Crescimento de Hepatócito/metabolismo , Fator de Crescimento de Hepatócito/química
5.
Proc Natl Acad Sci U S A ; 121(31): e2407501121, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39042697

RESUMO

This study explores the impact of electrostatic interactions and hydrogen bonding on tear film stability, a crucial factor for ocular surface health. While mucosal and meibomian layers have been extensively studied, the role of electrolytes in the aqueous phase remains unclear. Dry eye syndrome, characterized by insufficient tear quantity or quality, is associated with hyperosmolality, making electrolyte composition an important factor that might impact tear stability. Using a model buffer solution on a silica glass dome, we simulated physiologically relevant tear film conditions. Sodium chloride alone induced premature dewetting through salt crystal nucleation. In contrast, trace amounts of solutes with hydroxyl groups (sodium phosphate dibasic, potassium phosphate monobasic, and glucose) exhibited intriguing phenomena: quasi-stable films, solutal Marangoni-driven fluid influx increasing film thickness, and viscous fingering due to Saffman-Taylor instability. These observations are rationalized by the association of salt solutions with increased surface tension and the propensity of hydroxyl-group-containing solutes to engage in significant hydrogen bonding, altering local viscosity. This creates a viscosity contrast between the bulk buffer solution and the film region. Moreover, these solutes shield the glass dome, counteracting sodium chloride crystallization. These insights not only advance our understanding of tear film mechanics but also pave the way for predictive diagnostics in dry eye syndrome, offering a robust platform for personalized medical interventions based on individual tear film composition.


Assuntos
Eletrólitos , Ligação de Hidrogênio , Lágrimas , Lágrimas/química , Eletrólitos/química , Humanos , Viscosidade , Cloreto de Sódio/química , Fosfatos/química , Tensão Superficial , Eletricidade Estática , Síndromes do Olho Seco/metabolismo , Molhabilidade , Compostos de Potássio
6.
Drug Deliv ; 31(1): 2379369, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39010743

RESUMO

PURPOSE: Targeted drug delivery to the optic nerve head may be useful in the preclinical study and later clinical management of optic neuropathies, however, there are no FDA-approved drug delivery systems to achieve this. The purpose of this work was to develop an optic nerve head drug delivery technique. METHODS: Different strategies to approach the optic nerve head were investigated, including standard intravitreal and retroorbital injections. A novel SupraChoroidal-to-Optic-NervE (SCONE) delivery was optimized by creating a sclerotomy and introducing a catheter into the suprachoroidal space. Under direct visualization, the catheter was guided to the optic nerve head. India ink was injected. The suprachoroidal approach was performed in New Zealand White rabbit eyes in vivo (25 animals total). Parameters, including microneedle size and design, catheter design, and catheter tip angle, were optimized ex vivo and in vivo. RESULTS: Out of the candidate optic nerve head approaches, intravitreal, retroorbital, and suprachoroidal approaches were able to localize India ink to within 2 mm of the optic nerve. The suprachoroidal approach was further investigated, and after optimization, was able to deposit India ink directly within the optic nerve head in up to 80% of attempts. In eyes with successful SCONE delivery, latency and amplitude of visual evoked potentials was not different than the naïve untreated eye. CONCLUSIONS: SCONE delivery can be used for targeted drug delivery to the optic nerve head of rabbits without measurable toxicity measured anatomically or functionally. Successful development of this system may yield novel opportunities to study optic nerve head-specific drug delivery in animal models, and paradigm-shifting management strategies for treating optic neuropathies. TRANSLATIONAL RELEVANCE: Here we demonstrate data on a new method for targeted delivery to the optic nerve head, addressing a significant unmet need in therapeutics for optic neuropathies.


Assuntos
Sistemas de Liberação de Medicamentos , Animais , Coelhos , Corioide , Nervo Óptico/efeitos dos fármacos , Potenciais Evocados Visuais/efeitos dos fármacos , Disco Óptico , Injeções Intravítreas , Agulhas , Carbono
7.
Bioact Mater ; 40: 417-429, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39022184

RESUMO

In situ-forming hydrogels are an attractive option for corneal regeneration, and the delivery of growth factors from such constructs have the potential to improve re-epithelialization and stromal remodeling. However, challenges persist in controlling the release of therapeutic molecules from hydrogels. Here, an in situ-forming bio-orthogonally crosslinked hydrogel containing growth factors tethered via photocleavable linkages (PC-HACol hydrogel) was developed to accelerate corneal regeneration. Epidermal growth factor (EGF) was conjugated to the hydrogel backbone through photo-cleavable (PC) spacer arms and was released when exposed to mild intensity ultraviolet (UV) light (2-5 mW/cm2, 365 nm). The PC-HACol hydrogel rapidly gelled within a few minutes when applied to corneal defects, with excellent transparency and biocompatibility. After subsequent exposure to UV irradiation, the hydrogel promoted the proliferation and migration of corneal epithelial cells in vitro. The rate of re-epithelialization was positively correlated to the frequency of irradiation, verified through ex vivo rabbit cornea organ culture studies. In an in vivo rat corneal wound healing study, the PC-HACol hydrogel exposed to UV light significantly promoted re-epithelialization, the remodeling of stromal layers, and exhibited significant anti-scarring effects, with minimal α-SMA and robust ALDH3A1 expression. Normal differentiation of the regenerated epithelia after healing was evaluated by expression of the corneal epithelial biomarker, CK12. The remodeled cornea exhibited full recovery of corneal thickness and layer number without hyperplasia of the epithelium.

8.
Nanoscale ; 16(14): 6934-6938, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38511606

RESUMO

Efficient and robust quantification of the number of nanoparticles in solution is not only essential but also insufficient in nanotechnology and biomedical research. This paper proposes to use optical coherence tomography (OCT) to quantify the number of gold nanorods, which exemplify the nanoparticles with high light scattering signals. Additionally, we have developed an AI-enhanced OCT image processing to improve the accuracy and robustness of the quantification result.

9.
Res Sq ; 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38352508

RESUMO

Glaucoma is a leading cause of visual impairment and blindness in the United States and worldwide. Elevated intraocular pressure (IOP) has been identified as the only modifiable risk factor in glaucoma, and there exists a need for a glaucoma procedure that is safe, efficacious, and can be performed in the outpatient clinic setting. Suprachoroidal expansion has been explored as a method to lower IOP previously. The purpose of this work was to design a monolithic hydrogel implant that would not clear or degrade to potentially achieve long term (possibly permanent) IOP reduction. Here, we developed and showed ex vivo testing of a novel photo-crosslinked polyethylene glycol (PEG) suprachoroidal spacer implant delivered via a custom-designed injector system. We optimized the composition, shape, and mechanics of the implant to be suitable for implantation with the suprachoroidal space. We developed a microneedle injector system to deliver this implant. We showed precise control over implant location and volume occupied within the suprachoroidal space. Further preclinical testing is needed to demonstrate efficacy.

10.
Bioengineering (Basel) ; 11(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38247931

RESUMO

The corneal endothelium, comprising densely packed corneal endothelial cells (CECs) adhering to Descemet's membrane (DM), plays a critical role in maintaining corneal transparency by regulating water and ion movement. CECs have limited regenerative capacity within the body, and globally, there is a shortage of donor corneas to replace damaged corneal endothelia. The development of a carrier for cultured CECs may address this worldwide clinical need. In this study we successfully manufactured a gelatin nanofiber membrane (gelNF membrane) using electrospinning, followed by crosslinking with glutaraldehyde (GA). The fabricated gelNF membrane exhibited approximately 80% transparency compared with glass and maintained a thickness of 20 µm. The gelNF membrane demonstrated desirable permeability and degradability for a Descemet's membrane analog. Importantly, CECs cultured on the gelNF membrane at high densities showed no cytotoxic effects, and the expression of key CEC functional biomarkers was verified. To assess the potential of this gelNF membrane as a carrier for cultured CEC transplantation, we used it to conduct Descemet's membrane endothelial keratoplasty (DMEK) on rabbit eyes. The outcomes suggest this gelNF membrane holds promise as a suitable carrier for cultured CEC transplantation, offering advantages in terms of transparency, permeability, and sufficient mechanical properties required for successful transplantation.

11.
Adv Healthc Mater ; 13(25): e2303325, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38134346

RESUMO

Microextrusion-based 3D bioprinting into support baths has emerged as a promising technique to pattern soft biomaterials into complex, macroscopic structures. It is hypothesized that interactions between inks and support baths, which are often composed of granular microgels, can be modulated to control the microscopic structure within these macroscopic-printed constructs. Using printed collagen bioinks crosslinked either through physical self-assembly or bioorthogonal covalent chemistry, it is demonstrated that microscopic porosity is introduced into collagen inks printed into microgel support baths but not bulk gel support baths. The overall porosity is governed by the ratio between the ink's shear viscosity and the microgel support bath's zero-shear viscosity. By adjusting the flow rate during extrusion, the ink's shear viscosity is modulated, thus controlling the extent of microscopic porosity independent of the ink composition. For covalently crosslinked collagen, printing into support baths comprised of gelatin microgels (15-50 µm) results in large pores (≈40 µm) that allow human corneal mesenchymal stromal cells (MSCs) to readily spread, while control samples of cast collagen or collagen printed in non-granular support baths do not allow cell spreading. Taken together, these data demonstrate a new method to impart controlled microscale porosity into 3D printed hydrogels using granular microgel support baths.


Assuntos
Bioimpressão , Colágeno , Hidrogéis , Tinta , Células-Tronco Mesenquimais , Impressão Tridimensional , Humanos , Bioimpressão/métodos , Colágeno/química , Células-Tronco Mesenquimais/citologia , Hidrogéis/química , Microgéis/química , Porosidade , Viscosidade , Animais
12.
Clin Ophthalmol ; 17: 3323-3330, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026608

RESUMO

Purpose: We examine the rate of and reasons for follow-up in an Artificial Intelligence (AI)-based workflow for diabetic retinopathy (DR) screening relative to two human-based workflows. Patients and Methods: A DR screening program initiated September 2019 between one institution and its affiliated primary care and endocrinology clinics screened 2243 adult patients with type 1 or 2 diabetes without a diagnosis of DR in the previous year in the San Francisco Bay Area. For patients who screened positive for more-than-mild-DR (MTMDR), rates of follow-up were calculated under a store-and-forward human-based DR workflow ("Human Workflow"), an AI-based workflow involving IDx-DR ("AI Workflow"), and a two-step hybrid workflow ("AI-Human Hybrid Workflow"). The AI Workflow provided results within 48 hours, whereas the other workflows took up to 7 days. Patients were surveyed by phone about follow-up decisions. Results: Under the AI Workflow, 279 patients screened positive for MTMDR. Of these, 69.2% followed up with an ophthalmologist within 90 days. Altogether 70.5% (N=48) of patients who followed up chose their location based on primary care referral. Among the subset of patients that were seen in person at the university eye institute under the Human Workflow and AI-Human Hybrid Workflow, 12.0% (N=14/117) and 11.7% (N=12/103) of patients with a referrable screening result followed up compared to 35.5% of patients under the AI Workflow (N=99/279; χ2df=2 = 36.70, p < 0.00000001). Conclusion: Ophthalmology follow-up after a positive DR screening result is approximately three-fold higher under the AI Workflow than either the Human Workflow or AI-Human Hybrid Workflow. Improved follow-up behavior may be due to the decreased time to screening result.

13.
Ophthalmol Sci ; 3(4): 100330, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37449051

RESUMO

Objective: Detection of diabetic retinopathy (DR) outside of specialized eye care settings is an important means of access to vision-preserving health maintenance. Remote interpretation of fundus photographs acquired in a primary care or other nonophthalmic setting in a store-and-forward manner is a predominant paradigm of teleophthalmology screening programs. Artificial intelligence (AI)-based image interpretation offers an alternative means of DR detection. IDx-DR (Digital Diagnostics Inc) is a Food and Drug Administration-authorized autonomous testing device for DR. We evaluated the diagnostic performance of IDx-DR compared with human-based teleophthalmology over 2 and a half years. Additionally, we evaluated an AI-human hybrid workflow that combines AI-system evaluation with human expert-based assessment for referable cases. Design: Prospective cohort study and retrospective analysis. Participants: Diabetic patients ≥ 18 years old without a prior DR diagnosis or DR examination in the past year presenting for routine DR screening in a primary care clinic. Methods: Macula-centered and optic nerve-centered fundus photographs were evaluated by an AI algorithm followed by consensus-based overreading by retina specialists at the Stanford Ophthalmic Reading Center. Detection of more-than-mild diabetic retinopathy (MTMDR) was compared with in-person examination by a retina specialist. Main Outcome Measures: Sensitivity, specificity, accuracy, positive predictive value, and gradability achieved by the AI algorithm and retina specialists. Results: The AI algorithm had higher sensitivity (95.5% sensitivity; 95% confidence interval [CI], 86.7%-100%) but lower specificity (60.3% specificity; 95% CI, 47.7%-72.9%) for detection of MTMDR compared with remote image interpretation by retina specialists (69.5% sensitivity; 95% CI, 50.7%-88.3%; 96.9% specificity; 95% CI, 93.5%-100%). Gradability of encounters was also lower for the AI algorithm (62.5%) compared with retina specialists (93.1%). A 2-step AI-human hybrid workflow in which the AI algorithm initially rendered an assessment followed by overread by a retina specialist of MTMDR-positive encounters resulted in a sensitivity of 95.5% (95% CI, 86.7%-100%) and a specificity of 98.2% (95% CI, 94.6%-100%). Similarly, a 2-step overread by retina specialists of AI-ungradable encounters improved gradability from 63.5% to 95.6% of encounters. Conclusions: Implementation of an AI-human hybrid teleophthalmology workflow may both decrease reliance on human specialist effort and improve diagnostic accuracy. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

14.
ACS Appl Bio Mater ; 6(5): 1787-1797, 2023 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-37126648

RESUMO

Bioengineered corneal tissue is a promising therapeutic modality for the treatment of corneal blindness as a substitute for cadaveric graft tissue. In this study, we fabricated a collagen gel using ultraviolet-A (UV-A) light and riboflavin as a photosensitizer (PhotoCol-RB) as an in situ-forming matrix to fill corneal wounds and create a cohesive interface between the crosslinked gel and adjacent collagen. The PhotoCol-RB gels supported corneal epithelialization and exhibited higher transparency compared to physically crosslinked collagen. We showed that different riboflavin concentrations yielded gels with different mechanical and biological properties. In vitro experiments using human corneal epithelial cells (hCECs) showed that hCECs are able to proliferate on the gel and express corneal cell markers such as cytokeratin 12 (CK12) and tight junctions (ZO-1). Using an ex vivo burst assay, we also showed that the PhotoCol-RB gels are able to seal corneal perforations. Ex vivo organ culture of the gels filling lamellar keratectomy wounds showed that the epithelium that regenerated over the PhotoCol-RB gels formed a multilayer compared to just a double layer for those that grew over physically cross-linked collagen. These gels can be formed either in situ directly on the wound site to conform to the geometry of a defect, or can be preformed and then applied to the corneal wound. Our results indicate that PhotoCol-RB gels merit further investigation as a way to stabilize and repair deep and perforating corneal wounds.


Assuntos
Colágeno , Córnea , Humanos , Colágeno/farmacologia , Regeneração , Riboflavina/farmacologia , Géis/farmacologia
15.
Cornea ; 42(1): 97-104, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35965399

RESUMO

PURPOSE: We recently showed that in situ-forming collagen gels crosslinked through multifunctional polyethylene glycol (PEG) supported corneal epithelialization 7 days after treatment of lamellar keratectomy wounds. In this study, we aimed to evaluate the longer-term regenerative effects of this gel in animals. METHOD: Corneal wound healing was assessed 60 days after lamellar keratectomy and gel treatment using slitlamp examination, optical coherence tomography (OCT), pachymetry, corneal topography, an ocular response analyzer, and tonometry. The corneas were evaluated for the presence of beta-tubulin, cytokeratin 3, zonula occludens-1, and alpha smooth muscle actin (SMA) markers. Gene expression of aldehyde dehydrogenase 3A1 (ALDH3A1), cluster of differentiation 31, CD163, alpha-SMA, hepatocyte growth factor, and fibroblast growth factor 2 (FGF-2) and protein expression of CD44 and collagen VI were evaluated. RESULTS: Intraocular pressure, corneal thickness, and hysteresis for the corneas treated with collagen-PEG gels did not significantly change compared with the saline group. However, placido disk topography revealed greater regularity of the central cornea in the gel-treated group compared to the saline group. The gel-treated group exhibited a lower degree of epithelial hyperplasia than the saline group. Immunohistochemical and gene expression analysis showed that the gel-treated corneas exhibited lower alpha-SMA expression compared with the saline group. CD163 and CD44 were found to be elevated in the saline-treated group compared with normal corneas. CONCLUSIONS: The in situ-forming collagen-PEG gel promoted epithelialization that improved central corneal topography, epithelial layer morphology, and reduced expression of fibrotic and inflammatory biomarkers after 60 days compared to the saline group.


Assuntos
Lesões da Córnea , Hidrogéis , Animais , Polietilenoglicóis , Seguimentos , Colágeno/metabolismo , Córnea/metabolismo
16.
Transl Vis Sci Technol ; 11(10): 22, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36239965

RESUMO

Purpose: Millions worldwide suffer vision impairment or blindness from corneal injury, and there remains an urgent need for a more effective and accessible way to treat corneal defects. We have designed and characterized an in situ-forming semi-interpenetrating polymer network (SIPN) hydrogel using biomaterials widely used in ophthalmology and medicine. Methods: The SIPN was formed by cross-linking collagen type I with bifunctional polyethylene glycol using N-hydroxysuccinimide ester chemistry in the presence of linear hyaluronic acid (HA). Gelation time and the mechanical, optical, swelling, and degradation properties of the SIPN were assessed. Cytocompatibility with human corneal epithelial cells and corneal stromal stem cells (CSSCs) was determined in vitro, as was the spatial distribution of encapsulated CSSCs within the SIPN. In vivo wound healing was evaluated by multimodal imaging in an anterior lamellar keratectomy injury model in rabbits, followed by immunohistochemical analysis of treated and untreated tissues. Results: The collagen-hyaluronate SIPN formed in situ without an external energy source and demonstrated mechanical and optical properties similar to the cornea. It was biocompatible with human corneal cells, enhancing CSSC viability when compared with collagen gel controls and preventing encapsulated CSSC sedimentation. In vivo application of the SIPN significantly reduced stromal defect size compared with controls after 7 days and promoted multilayered epithelial regeneration. Conclusions: This in situ-forming SIPN hydrogel may be a promising alternative to keratoplasty and represents a step toward expanding treatment options for patients suffering from corneal injury. Translational Relevance: We detail the synthesis and initial characterization of an SIPN hydrogel as a potential alternative to lamellar keratoplasty and a tunable platform for further development in corneal tissue engineering and therapeutic cell delivery.


Assuntos
Lesões da Córnea , Hidrogéis , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/uso terapêutico , Colágeno/química , Colágeno/farmacologia , Colágeno/uso terapêutico , Colágeno Tipo I , Ésteres , Humanos , Ácido Hialurônico/química , Ácido Hialurônico/farmacologia , Ácido Hialurônico/uso terapêutico , Hidrogéis/química , Hidrogéis/farmacologia , Hidrogéis/uso terapêutico , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Polietilenoglicóis/uso terapêutico , Polímeros/química , Coelhos
17.
Transl Vis Sci Technol ; 11(9): 9, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36112103

RESUMO

Purpose: To investigate and quantify the effect of recombinant human lubricin (rh-lubricin) on model tear film stability. Methods: A custom-built, interferometry-based instrument called the Interfacial Dewetting and Drainage Optical Platform was used to create and record the spatiotemporal evolution of model acellular tear films. Image segmentation and analysis was performed in MATLAB to extract the most essential features from the wet area fraction versus time curve, namely the evaporative break-up time and the final wet area fraction (A10). These two parameters indicate the tear film stability in the presence of rh-lubricin in its unstressed and stressed forms. Results: Our parameters successfully captured the trend of increasing tear film stability with increasing rh-lubricin concentration, and captured differences in rh-lubricin efficacy after various industrially relevant stresses. Specifically, aggregation and fragmentation caused by a 4-week, high temperature stress condition negatively impacted rh-lubricin's ability to maintain model tear film stability. Adsorbed rh-lubricin alone was not sufficient to resist break-up and maintain full area coverage of the model tear film surface. Conclusions: Our results demonstrate that fragmentation and aggregation can negatively impact rh-lubricin's ability to maintain a stable tear film. In addition, the ability of rh-lubricin to maintain wetted area coverage is due to both freely dispersed and adsorbed rh-lubricin. Translational Relevance: Our platform and analysis method provide a facile, intuitive, and clinically relevant means to quantify the effect of ophthalmic drugs and formulations intended for improving tear film stability, as well as capture differences between variants related to drug stability and efficacy.


Assuntos
Glicoproteínas , Lágrimas , Glicoproteínas/química , Glicoproteínas/farmacologia , Humanos , Interferometria/métodos , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacologia , Lágrimas/química , Visão Ocular
18.
J Phys Chem B ; 126(33): 6338-6344, 2022 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-35972346

RESUMO

In this work, we describe the development of a tunable, acellular in vitro model of the mucin layer of the human tear film. First, supported lipid bilayers (SLBs) comprised of the phospholipid DOPC (1,2-dioleoyl-sn-glycero-3-phosphocholine) and biotinyl cap PE (1,2-dioleoyl-sn-glycero-3-phosphoethanolamine-N-(cap biotinyl)) are created on the surface of a glass dome with radius of curvature comparable to the human eye. Next, biotinylated bovine submaxillary mucins (BSM) are tethered onto the SLB using streptavidin protein. The mucin presentation can be tuned by altering the concentration of biotinylated BSM, which we confirm using fluorescence microscopy. Due to the optically smooth surface that results, this model is compatible with interferometry for monitoring film thickness. Below a certain level of mucin coverage, we observe short model tear film breakup times, mimicking a deficiency in membrane-associated mucins. In contrast, the breakup time is significantly delayed for SLBs with high mucin coverage. Because no differences in mobility or wettability were observed, we hypothesize that higher mucin coverage provides a thicker hydrated layer that can protect against external disturbances to thin film stability. This advance paves the way for a more physiological, interferometry-based in vitro model for investigating tear film breakup.


Assuntos
Bicamadas Lipídicas , Fosfolipídeos , Animais , Bovinos , Humanos , Microscopia de Fluorescência , Mucinas
19.
Diagnostics (Basel) ; 12(7)2022 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-35885619

RESUMO

While color fundus photos are used in routine clinical practice to diagnose ophthalmic conditions, evidence suggests that ocular imaging contains valuable information regarding the systemic health features of patients. These features can be identified through computer vision techniques including deep learning (DL) artificial intelligence (AI) models. We aim to construct a DL model that can predict systemic features from fundus images and to determine the optimal method of model construction for this task. Data were collected from a cohort of patients undergoing diabetic retinopathy screening between March 2020 and March 2021. Two models were created for each of 12 systemic health features based on the DenseNet201 architecture: one utilizing transfer learning with images from ImageNet and another from 35,126 fundus images. Here, 1277 fundus images were used to train the AI models. Area under the receiver operating characteristics curve (AUROC) scores were used to compare the model performance. Models utilizing the ImageNet transfer learning data were superior to those using retinal images for transfer learning (mean AUROC 0.78 vs. 0.65, p-value < 0.001). Models using ImageNet pretraining were able to predict systemic features including ethnicity (AUROC 0.93), age > 70 (AUROC 0.90), gender (AUROC 0.85), ACE inhibitor (AUROC 0.82), and ARB medication use (AUROC 0.78). We conclude that fundus images contain valuable information about the systemic characteristics of a patient. To optimize DL model performance, we recommend that even domain specific models consider using transfer learning from more generalized image sets to improve accuracy.

20.
Biomater Sci ; 10(17): 4997-5005, 2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-35815427

RESUMO

As the collagen layer weakens with increasing age or certain diseases such as keratoconus and myopia, the mechanical property of the collagen layer decreases with corneal deformation. To circumvent these problems, the corneal collagen has been crosslinked with the photosensitizer riboflavin under UV light after de-epithelialization. However, this treatment with riboflavin and UV light can cause notable damage to the eye. Here, the biocompatible rose bengal (RB) dye was conjugated to hyaluronic acid (HA) to enhance the corneal permeability, which can be activated by safe green light with a wavelength of 530 nm. Two-photon microscopy revealed the deep tissue penetration of the HA-RB conjugate in comparison with RB. Collagen fibrillogenesis, ex vivo tensile test, and ex vivo histological analysis confirmed the effective collagen crosslinking by HA-RB conjugate and the light irradiation. Furthermore, we developed a smart contact lens for on-demand HA-RB conjugate delivery from the reservoir embedded in the contact lens. Taken together, we could envision the feasibility of a smart contact lens for biophotonic myopia vision correction.


Assuntos
Lentes de Contato , Miopia , Colágeno , Reagentes de Ligações Cruzadas , Humanos , Ácido Hialurônico , Miopia/tratamento farmacológico , Fármacos Fotossensibilizantes , Riboflavina , Rosa Bengala , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...