Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38667445

RESUMO

Glucose meters provide a rapid blood glucose status for evidence-based diagnosis, monitoring, and treatment of diabetes mellitus. We aimed to evaluate the commutability of processed blood materials (PBMs) and their use in the performance evaluation of glucose meters. Two PBMs obtained by the fixed-cell method were analyzed for homogeneity, stability, and commutability. The compatibility of ten pairs between mass spectrometry and each glucose meter was categorized as compatible (mean paired difference ≤ 5%) and incompatible (mean paired difference > 5%). The performance of glucose meter 1 (n = 767) and glucose meter 2 (n = 266) was assessed. The glucose in the PBMs remained homogenized and stable for at least 180 days. Six out of ten pairs had commutable PBMs. Commutability of PBMs was observed in both well-compatible and incompatible glucose results. Target glucose values from mass spectrometry were significantly different (p ≤ 0.05) from consensus values in one group of glucose meters. When commutable PBMs were used, glucose meter 1 showed better performance than glucose meter 2, and the percentage of satisfaction was associated when using target values for glucose from mass spectrometry and consensus values, but the performance of glucose meter 2 was not associated. PBM from a fixed-cell method could be mass produced with acceptable homogeneity and stability. Commutability testing of PBMs is required prior to use in the performance evaluation of glucose meters, as the commutability of glucose in the PBMs obtained by a fixed-cell method was variable and depended on the individual glucose meter.

2.
Clin Lab ; 70(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38469786

RESUMO

BACKGROUND: Hemoglobin A1C (HbA1C) is used to evaluate glycemic control over a three-month period. Blood matrix-based HbA1C materials are needed for quality control and evaluation of HbA1C measurements. This study investigated the commutability of blood materials (BMs) and aimed to upgrade BMs for HbA1C testing for use as proficiency test (PT) material. METHODS: We measured BMs from a DM blood donor (n = 1), an in vitro glycation procedure (n = 3), and from commercial sources (n = 2) for HbA1C in parallel with fresh unprocessed BMs (n = 3) and clinical blood samples (n = 25). Two NGSP-certified methods, including a turbidimetric and an enzymatic immunoassay, were used for HbA1C determinations. Commutability as investigated according to CLSI EP14-Ed4 guidelines. RESULTS: The commutable BMs exhibited a mean paired difference of 0% to 9% when compared to reference methods, whereas the non-commutable BMs represented a mean paired difference of 3% to 11%. Fresh, unprocessed BMs with a low HbA1C of 6.0% were more commutable than BMs with a high HbA1C. The values of HbA1C in BMs (mean and uncertainty following ISO Guide 35 for RM production) were applied to upgrade the PT material to be used as a reference material. The relative uncertainty of BM-Ndm-1 and BM-Gcb-3 were 1 and 0.4%, respectively. CONCLUSIONS: The commutability of hemoglobin in BMs is dependent on the preparation process. Blood materials with a high HbA1C content are usually less commutable versus materials with low HbA1C content when prepared by the same process. Our study showed BMs can be successfully used as quality control or PT materials.


Assuntos
Testes Hematológicos , Humanos , Padrões de Referência , Hemoglobinas Glicadas , Incerteza , Controle de Qualidade
3.
Sensors (Basel) ; 20(15)2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32718040

RESUMO

A detection method for type-II pyrethroids in an environmental water sample using a microfluidic paper-based analytical device (µPAD) is reported here. The detection approach is based on the formation of cyanide from the hydrolysis of type-II pyrethroids and the colorimetric detection of cyanide on a layer-based µPAD. Parafilm and inexpensive laminating pouches were used to create a hydrophobic barrier for the assay on the µPAD. This detection approach was selective to type-II pyrethroids in water for which an environmental water sample was tested. The calibration curves for cypermethrin, deltamethrin, cyhalothrin, and fenvalerate ranged from 2 to 40 µg/mL without sample preconcentration. The lower concentrations of type-II pyrethroids can be assessed by including a preconcentration step prior to the detection on a µPAD. This detection system provides an alternative platform for fast, semiquantitative testing for pesticide contamination in environmental surface water by allowing for portability, low reagent/sample consumption, and low-cost testing.

4.
Anal Bioanal Chem ; 411(28): 7341-7355, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31667564

RESUMO

Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place. Metrology institutes worldwide maintain infrastructure for the practical realization of metrological traceability and demonstrate the equivalence of their measurement capabilities through participation in key comparisons organized under the auspices of the CCQM. These institutes provide certified reference materials, as well as other dedicated value-assignment services benefiting the in-vitro diagnostic (IVD) industry, reference (calibration) laboratories and the clinical chemistry laboratories. The roles of these services in supporting national, regional, and international activities to ensure the metrological traceability of clinical chemistry measurements are described. Graphical abstract.


Assuntos
Biomarcadores/análise , Compostos Orgânicos/análise , Bibliotecas de Moléculas Pequenas/análise , Calibragem , Testes de Química Clínica , Humanos , Técnicas In Vitro , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...