Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Int J Numer Method Biomed Eng ; : e3857, 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39075679

RESUMO

Renal anisotropy is a complex property of the kidney and often poses a challenge in obtaining consistent measurements when using shear wave elastography to detect chronic kidney disease. To circumvent the challenge posed by renal anisotropy in clinical settings, a dimensionless biomarker termed the 'anisotropic ratio' was introduced to establish a correlation between changes in degree of renal anisotropy and progression of chronic kidney disease through an in silico perspective. To achieve this, an efficient model reduction approach was developed to model the anisotropic property of kidneys. Good agreement between the numerical and experimental data were obtained, as percentage errors of less than 5.5% were reported when compared against experimental phantom measurement from the literature. To demonstrate the applicability of the model to clinical measurements, the anisotropic ratio of sheep kidneys was quantified, with both numerical and derived experimental results reporting a value of .667. Analysis of the anisotropic ratio with progression of chronic kidney disease demonstrated that patients with normal kidneys would have a lower anisotropic ratio of .872 as opposed to patients suffering from renal impairment, in which the anisotropic ratio may increase to .904, as determined from this study. The findings demonstrate the potential of the anisotropic ratio in improving the detection of chronic kidney disease using shear wave elastography.

2.
Ultrasonics ; 133: 107046, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37247461

RESUMO

The application of ultrasound shear wave elastography for detecting chronic kidney disease, namely renal fibrosis, has been widely studied. A good correlation between tissue Young's modulus and the degree of renal impairment has been established. However, the current limitation of this imaging modality pertains to the linear elastic assumption used in quantifying the stiffness of renal tissue in commercial shear wave elastography systems. As such, when underlying medical conditions such as acquired cystic kidney disease, which may potentially influence the viscous component of renal tissue, is present concurrently with renal fibrosis, the accuracy of the imaging modality in detecting chronic kidney disease may be affected. The findings in this study demonstrate that quantifying the stiffness of linear viscoelastic tissue using an approach similar to those implemented in commercial shear wave elastography systems led to percentage errors as high as 87%. The findings presented indicate that use of shear viscosity to detect changes in renal impairment led to a reduction in percentage error to values as low as 0.3%. For cases in which renal tissue was affected by multiple medical conditions, shear viscosity was found to be a good indicator in gauging the reliability of the Young's modulus (quantified through a shear wave dispersion analysis) in detecting chronic kidney disease. The findings show that percentage error in stiffness quantification can be reduced to as low as 0.6%. The present study demonstrates the potential use of renal shear viscosity as a biomarker to improve the detection of chronic kidney disease.


Assuntos
Técnicas de Imagem por Elasticidade , Insuficiência Renal Crônica , Humanos , Técnicas de Imagem por Elasticidade/métodos , Viscosidade , Reprodutibilidade dos Testes , Análise de Elementos Finitos , Insuficiência Renal Crônica/diagnóstico por imagem , Módulo de Elasticidade , Fibrose , Biomarcadores
3.
Biomed Phys Eng Express ; 9(4)2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37216929

RESUMO

Objective. To develop an algorithm to measure slice thickness running on three types of Catphan phantoms with the ability to adapt to any misalignment and rotation of the phantoms.Method. Images of Catphan 500, 504, and 604 phantoms were examined. In addition, images with various slice thicknesses ranging from 1.5 to 10.0 mm, distance to the iso-center and phantom rotations were also examined. The automatic slice thickness algorithm was carried out by processing only objects within a circle having a diameter of half the diameter of the phantom. A segmentation was performed within an inner circle with dynamic thresholds to produce binary images with wire and bead objects within it. Region properties were used to distinguish wire ramps and bead objects. At each identified wire ramp, the angle was detected using the Hough transform. Profile lines were then placed on each ramp based on the centroid coordinates and detected angles, and the full-width at half maximum (FWHM) was determined for the average profile. The slice thickness was obtained by multiplying the FWHM by the tangent of the ramp angle (23°).Results. Automatic measurements work well and have only a small difference (<0.5 mm) from manual measurements. For slice thickness variation, automatic measurement successfully performs segmentation and correctly locates the profile line on all wire ramps. The results show measured slice thicknesses that are close (<3 mm) to the nominal thickness at thin slices, but slightly deviated for thicker slices. There is a strong correlation (R2= 0.873) between automatic and manual measurements. Testing the algorithm at various distances from the iso-center and phantom rotation angle also produced accurate results.Conclusion. An automated algorithm for measuring slice thickness on three types of Catphan CT phantom images has been developed. The algorithm works well on various thicknesses, distances from the iso-center, and phantom rotations.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos
4.
Ultrasound Med Biol ; 47(8): 2033-2047, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33958257

RESUMO

Early detection of chronic kidney disease is important to prevent progression of irreversible kidney damage, reducing the need for renal transplantation. Shear wave elastography is ideal as a quantitative imaging modality to detect chronic kidney disease because of its non-invasive nature, low cost and portability, making it highly accessible. However, the complexity of the kidney architecture and its tissue properties give rise to various confounding factors that affect the reliability of shear wave elastography in detecting chronic kidney disease, thus limiting its application to clinical trials. The objective of this review is to highlight the confounding factors presented by the complex properties of the kidney, in addition to outlining potential mitigation strategies, along with the prospect of increasing the versatility and reliability of shear wave elastography in detecting chronic kidney disease.


Assuntos
Técnicas de Imagem por Elasticidade , Insuficiência Renal Crônica/diagnóstico por imagem , Anisotropia , Técnicas de Imagem por Elasticidade/tendências , Previsões , Hemodinâmica , Humanos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...