RESUMO
Purpose: To report our experience with patient specific implants for one-step orbit reconstruction following hyperostotic SWM removal and to describe the evolution of the technique through three surgical cases. Methods: Three cases of one-step SWM removal and orbit reconstruction are described. All cases are given consecutively to describe the evolution of the technique. Hyperostotic bone resection was facilitated by electromagnetic navigation and cutting guides (templates). Based on a 3D model, silicone molds were made using CAD/CAM. Then PMMA implant was fabricated from these molds. The implant was adjusted and fixed to the cranium with titanium screws after tumor removal. Results: Following steps of the procedure changed over these series: hyperostotic bone resection, implant thickness control, implant overlay features, anatomic adjustments, implant fixation. The proptosis resolved in all cases. In one patient the progressive visual acuity deterioration was recognized during the follow-up. No oculomotor disturbances and no tumor regrowth were found at the follow-up. Conclusion: CAD/CAM technologies enable creation of implants of any size and configuration, and thereby, to increase the extent of bony resection and lower the risk of tumor progression. The procedure is performed in one step which decreases the risk of postoperative morbidity.
RESUMO
OBJECTIVE: Analysis of results of surgical treatment of 112 patients with large and giant anterior cerebral artery (ACA) aneurysms. METHODS: This is the largest clinical series of large and giant ACA aneurysms ever reported. Retrospective analysis of medical charts, radiographic studies, and intraoperative videos was performed. Univariate and multivariate analysis of relations among 3 types of outcomes (complete aneurysm occlusion, ischemic complications, and clinical outcomes) and predicting factors was performed. RESULTS: Most aneurysms were communicant (84.8%). Aneurysms of the A1 segment and distal segments (A2-A5) were encountered rarely. Complete aneurysm occlusion (class I) was shown in 95 cases (90.5%). In 4 patients, only exploration and wrapping were performed because of severe atherosclerosis and chronic intraluminal thrombi. Partial occlusion (class III) was shown in 2 patients, and neck residual (class II) in 4 patients. Cerebral ischemia developed in 29 patients postoperatively. Occlusion or injury of the A1 segment and anterior communicating artery perforators and recurrent branch of Heubner were the most common reason for ischemic complications. At follow-up, 97 patients (86.6%) had favorable outcomes. Ten patients (8.9%) had unfavorable outcomes because of postoperative complications. CONCLUSIONS: Microsurgery provides effective and relatively safe occlusion of complex ACA aneurysms. Direct clipping can be applied in most cases independent of their precise location. In certain cases, alternative methods can be safely used. According to multivariate analysis, giant aneurysm size, aneurysm-related mass effect, involvement of large arterial branches in the aneurysm wall, and intraoperative complications were significant predicting factors for ischemic complications.