RESUMO
After its first introduction in 2002, transcatheter aortic valve implantation (TAVI) has continuously gained more foothold for the treatment of severe aortic stenosis and is nowadays a viable treatment option for inoperable patients or patients at high risk for conventional surgical aortic valve replacement. Although ideally carried out in a so-called hybrid room, incorporating both the strict hygiene and advanced life support possibilities of the operating theatre and the imaging and percutaneous arsenal of the catheterisation suite, in most centres TAVI is at present performed in the catheterisation laboratory. This may raise concern about an increased risk of infection, since there the criteria that are applied regarding disinfection and sterilisation are not as stringent as those of the operating theatre. Therefore, we retrospectively assessed the number of infective complications in patients undergoing TAVI in the catheterisation lab of our institution. Eleven out of 73 patients developed a postprocedural infection, one of which could be attributed to the procedure itself, being superinfection of a surgical groin cut-down. Our conclusion is that percutaneous aortic valve implantation in a catheterisation laboratory is not associated with an increased risk of infective complications.
RESUMO
The implantation of intracoronary stents is currently the standard approach for the treatment of coronary atherosclerotic disease. The widespread adoption of this technology has boosted an intensive research activity in this domain, with continuous improvements in the design of these devices, aiming at reducing problems of restenosis (re-narrowing of the stented segment) and thrombosis (sudden occlusion due to thrombus formation). Recently, a new, light-based intracoronary imaging modality, optical coherence tomography (OCT), was developed and introduced into clinical practice. Due to its very high axial resolution (10-15 µm), it allows for in vivo evaluation of both stent strut apposition and neointima coverage (a marker of healing of the treated segment). As such, it provides valuable information on proper stent deployment, on the behaviour of different stent types in-vivo and on the effect of new types of stents (e.g. drug-eluting stents) on vessel wall healing. However, the major drawback of the current OCT methodology is that analysis of these images requires a tremendous amount of-currently manual-post-processing. In this manuscript, an algorithm is presented that allows for fully automated analysis of stent strut apposition and coverage in coronary arteries. The vessel lumen and stent struts are automatically detected and segmented through analysis of the intensity profiles of the A-lines. From these data, apposition and coverage can then be measured automatically. The algorithm was validated using manual assessments by two experienced operators as a reference. High Pearson's correlation coefficients were found (R = 0.96-0.97) between the automated and manual measurements while Bland-Altman analysis showed no significant bias with good limits of agreement. As such, it was shown that the presented algorithm provides a robust and fast tool to automatically estimate apposition and coverage of stent struts in in-vivo OCT pullbacks. This will be important for the integration of this technology in clinical routine and for the analysis of datasets of larger clinical trials.
Assuntos
Algoritmos , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Processamento de Imagem Assistida por Computador , Stents , Tomografia de Coerência Óptica , Angioplastia Coronária com Balão/efeitos adversos , Automação , Humanos , Hiperplasia , Neointima/etiologia , Neointima/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Resultado do TratamentoAssuntos
Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Embolia Intracraniana/complicações , Embolia Intracraniana/diagnóstico , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico , Embolia , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Humanos , Pessoa de Meia-Idade , Trombose Venosa/complicações , Trombose Venosa/diagnósticoRESUMO
We present a case of iatrogenic left main coronary artery dissection, successfully treated by prompt bail-out stenting, and provide a brief discussion on its occurrence and treatment, as well as the immediate and long-term outcome of percutaneous coronary intervention, including our own single-centre experience, for this potentially catastrophic complication.