RESUMO
An efficient mode of evaluation for eye movements is the use of objective eye tracking systems combined with subjective tests (NSUCO or DEM), which are easily applicable across all age groups and in eye care clinical settings. The objective of this study was to characterize fixations during reading in two groups: a group of children with neurodevelopmental disorders (NDDG, 24 children, age: 6-12 years) and a group of children with oculomotor anomalies but without NDD (OAG, 24 children, age: 6-12 years). The results obtained were compared with those from a control group (CG, 20 children, age: 6-12 years). Specifically, the outcomes obtained with two subjective score systems, the Northeastern State University College of Optometry's Oculomotor (NSUCO) test and the Developmental Eye Movement (DEM) test, were compared with the objective analysis obtained through a commercially available eye tracker (Tobii Eye X, Tobii, Stockholm, Sweden). Specialized analysis software, namely Clinical Eye Tracker 2020 (Thomson Software Solutions, Welham Green, UK), was used. It was found that children with NDD had impaired oculomotor skills. A higher number of regressions, more fixations, and longer durations of fixations appear to be characteristic signs of this population group. Additionally, children with NDD took longer to complete the DEM test, as well as exhibiting more errors. The use of objective videoculographic systems for eye tracking and subjective tests like the NSUCO or DEM are good tools to assess saccadic movements, allowing the detection of oculomotor abnormalities in children with NDD.
RESUMO
Spatial aspects of visual performance are usually evaluated through visual acuity charts and contrast sensitivity (CS) tests. CS tests are generated by vanishing the contrast level of the visual charts. However, the quality of retinal images can be affected by both ocular aberrations and scattering effects and none of those factors are incorporated as parameters in visual tests in clinical practice. We propose a new computational methodology to generate visual acuity charts affected by ocular scattering effects. The generation of glare effects on the visual tests is reached by combining an ocular straylight meter methodology with the Commission Internationale de l'Eclairage's (CIE) general disability glare formula. A new function for retinal contrast assessment is proposed, the subjective straylight function (SSF), which provides the maximum tolerance to the perception of straylight in an observed visual acuity test. Once the SSF is obtained, the subjective straylight index (SSI) is defined as the area under the SSF curve. Results report the normal values of the SSI in a population of 30 young healthy subjects (19 ± 1 years old), a peak centered at SSI = 0.46 of a normal distribution was found. SSI was also evaluated as a function of both spatial and temporal aspects of vision. Ocular wavefront measures revealed a statistical correlation of the SSI with defocus and trefoil terms. In addition, the time recovery (TR) after induced total disability glare and the SSI were related; in particular, the higher the RT, the greater the SSI value for high- and mid-contrast levels of the visual test. No relationships were found for low contrast visual targets. To conclude, a new computational method for retinal contrast assessment as a function of ocular straylight was proposed as a complementary subjective test for visual function performance.
RESUMO
PURPOSE: To evaluate alterations of the choroid in patients with a neurodegenerative disease versus healthy controls, a custom algorithm based on superpixel segmentation was used. DESIGN: A cross-sectional study was conducted on data obtained in a previous cohort study. SUBJECTS: Swept-source optical coherence tomography (OCT) B-scan images obtained using a Triton (Topcon, Japan) device were compiled according to current OSCAR IB and APOSTEL OCT image quality criteria. Images were included from three cohorts: multiple sclerosis (MS) patients, Parkinson disease (PD) patients, and healthy subjects. Only patients with early-stage MS and PD were included. METHODS: In total, 104 OCT B-scan images were processed using a custom superpixel segmentation (SpS) algorithm to detect boundary limits in the choroidal layer and the optical properties of the image. The algorithm groups pixels with similar structural properties to generate clusters with similar meaningful properties. MAIN OUTCOMES: SpS selects and groups the superpixels in a segmented choroidal area, computing the choroidal optical image density (COID), measured as the standard mean gray level, and the total choroidal area (CA), measured as px2. RESULTS: The CA and choroidal density (CD) were significantly reduced in the two neurodegenerative disease groups (higher in PD than in MS) versus the healthy subjects (p < 0.001); choroidal area was also significantly reduced in the MS group versus the healthy subjects. The COID increased significantly in the PD patients versus the MS patients and in the MS patients versus the healthy controls (p < 0.001). CONCLUSIONS: The SpS algorithm detected choroidal tissue boundary limits and differences optical density in MS and PD patients versus healthy controls. The application of the SpS algorithm to OCT images potentially acts as a non-invasive biomarker for the early diagnosis of MS and PD.
RESUMO
This cross-sectional and observational study includes 50 eyes of subjects with color blindness and 50 eyes of control subjects. Visual function (visual acuity, contrast sensitivity, and color vision) and neuroretinal structure were assessed in all subjects using optical coherence tomography (OCT). Significant thinning of the retinal nerve fiber layer, ganglion cell layer, and retina were observed in the color blindness group. Significant thinning was also recorded in layers that involve photoreceptor nuclei (between the outer limiting layer and the Bruch membrane and between the outer plexiform layer and the outer limiting membrane). OCT evaluation based on retinal segmentation is a rapid (5-10 minutes) non-invasive technique and seems to be a good biomarker of color blindness.
Assuntos
Defeitos da Visão Cromática , Visão de Cores , Humanos , Estudos Transversais , Retina , Acuidade Visual , Tomografia de Coerência Óptica/métodosRESUMO
The purpose of the present study was to examine the visual perception system in expert climbers through a psychophysical optical test in a cross-sectional study. Twenty-seven male participants with an International Rock Climbing Research Association (IRCRA) best on-sight lead skill level ranging between 18 and 27 and a best red-point level ranging between 18 and 29 completed a series of psychophysical optic tests assessing their visual field, visual acuity, and contrast sensitivity. Climbers were divided by their best red-pointed lead level, and, following IRCRA recommendations, two groups were created: an advanced group (IRCRA redpoint level between 18 and 23), and an elite-high elite group (IRCRA redpoint level between 24 and 29). The elite group presented more training days per week (5.25 ± 1.28), best on-sighted lead level (24.63 ± 1.92 IRCRA), and best red-pointed lead level (26.63 ± 2.56 IRCRA) than the advanced group (3.67 ± 0.91 training days per week, 19.50 ± 1.04 IRCRA on-sighted level and 20.67 ± 1.57 IRCRA red-pointed level). Better visual perception outputs were produced by the group of elite climbers in visual field tests; no differences were observed between the two groups for visual acuity and contrast sensitivity tests. Overall, findings indicate that best climbers performed better at the visual perception tasks that tested their visual field. Such better perception from best climbers is discussed given (1) the greater time they spend coercing the visual system during practicing climbing and (2) the specific complexity of the stimuli as they are confronted to harder routes where holds are less perceptible and the time to find best hold sequences is constrained.
RESUMO
PURPOSE: To evaluate the ability of new Swept source (SS) optical coherence tomography (OCT) technology to detect changes in retinal and choroidal thickness in patients with Parkinson's disease (PD). DESIGN: Observational case-control cross sectional study, developed from January to May 2016. METHODS: In total, 50 eyes from 50 patients diagnosed with PD and 54 eyes of 54 healthy controls underwent retinal and choroidal assessment using SS DRI Triton OCT (Topcon), using the 3D Wide protocol. Total macular thickness and peripapillary data (retinal, ganglion cell layer [GCL+, GCL++] and retinal nerve fiber layer [RNFL] thickness) were analyzed. Macular and peripapillary choroidal thickness was evaluated (Figure 1). RESULTS: Significant peripapillary retinal thinning was observed in PD patients in total average (p = 0.017), in the nasal (p = 0.038) and temporal (p = 0.004) quadrants and in superotemporal (p = 0.004), nasal (p = 0.039), inferotemporal (p = 0.019), and temporal (p = 0.003) sectors. RNFL and GCL ++ thickness showed a significant reduction in the inferotemporal sector (p = 0.026 and 0.009, respectively). No differences were observed in macular retinal thickness between controls and patients. Choroidal thickness was found to have increased in all sectors in PD patients compared with controls, both in the macular (inner nasal, p = 0.015; inner inferior, p = 0.030; outer nasal, p = 0.012; outer inferior, p = 0.049) and the peripapillary area (total thickness, p = 0.011; nasal, p = 0.025; inferior, p = 0.007; temporal, p = 0.003; inferotemporal, p = 0.003; inferonasal, p = 0.016) Conclusion: New SS technology for OCT devices detects retinal thinning in PD patients, providing increased depth analysis of the choroid in these patients. The choroid in PD may present increased thickness compared to healthy individuals; however, more studies and histological analysis are needed to corroborate our findings.
Assuntos
Corioide/patologia , Macula Lutea/patologia , Disco Óptico/patologia , Doença de Parkinson/complicações , Doenças Retinianas/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Fibras Nervosas/patologia , Doença de Parkinson/patologia , Doenças Retinianas/etiologia , Estudos RetrospectivosRESUMO
OBJECTIVE: To assess changes in the retinal nerve fiber layer (RNFL) and macula in subjects with cardiovascular risk factors or subclinical ischemia. DESIGN: Prospective and observational study. METHODS: A total of 152 healthy men underwent cardiovascular examination, including quantification of subclinical atheroma plaques by artery ultrasound scans, blood analysis, and a complete ophthalmic evaluation, including spectral-domain optical coherence tomography. The variables registered in cardiovascular examination were quantification of classic major risk factors, subclinical atheroma plaques by artery ultrasound scans, and analytical records. The ophthalmic evaluation registered RNFL and macular thickness. RESULTS: Mean subject age was 51.27±3.71 years. The 40 subjects without classic cardiovascular risk factors did not show differences in RNFL and macular thicknesses compared with the 112 subjects with at least one risk factor (except in sector 9 that showed higher thicknesses in subjects with ≥1 risk factor). Comparison between the group of subjects with and without atheroma plaques revealed no differences in RNFL and macular thicknesses. The sub-analysis of subjects with subclinical atheroma plaques in the common carotid artery revealed a significant reduction in central macular thickness in the left eye compared with the right eye (p = 0.016), RNFL in the superior quadrant (p = 0.007), and the 11 o'clock sector (p = 0.020). Comparison between smokers and nonsmokers revealed that smokers had significant thinning of the central macular thickness (p = 0.034), the nasal RNFL quadrant (p = 0.006), and the 3 and 5 o'clock sectors (p = 0.016 and 0.009). CONCLUSIONS: Classic cardiovascular risk factors do not cause RNFL or macular thickness reduction, but tobacco smoking habit reduces nasal RNFL thickness. Subclinical atherosclerosis in the common carotid artery associates a reduction in central macular and nasal RNFL quadrant thicknesses in the left eye compared with the right eye.
Assuntos
Fenômenos Fisiológicos Cardiovasculares , Fibras Nervosas , Retina/anatomia & histologia , Adulto , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
Purpose: To quantify changes in visual function parameters and in the retinal nerve fiber layer and macular thickness over a 5-year period in patients with Parkinson's disease (PD). Methods: Thirty patients with PD and 30 healthy subjects underwent a complete ophthalmic evaluation, including assessment of visual acuity, contrast sensitivity vision, color vision, and retinal evaluation with spectral-domain optical coherence tomography (SD-OCT). All subjects were reevaluated after 5 years to quantify changes in visual function parameters, the retinal nerve fiber layer, and macular thickness. Association between progressive ophthalmologic changes and disease progression was analyzed. Results: Changes were detected in visual function parameters and retinal nerve fiber layer thickness in patients compared with controls. Greater changes were found during the follow-up in the PD group than healthy subjects in visual acuity, contrast sensitivity, Lanthony color test (P < 0.016), in superotemporal and temporal retinal nerve fiber layer sectors (P < 0.001), and in macular thickness (all sectors except inner superior and inner inferior sectors, P < 0.001). Progressive changes in the retinal nerve fiber layer were associated with disease progression (r = 0.389, P = 0.028). Conclusions: Progressive visual dysfunction, macular thinning, and axonal loss can be detected in PD. Analysis of the macular thickness and the retinal nerve fiber layer by SD-OCT can be useful for evaluating Parkinson's disease progression.
Assuntos
Doença de Parkinson/complicações , Retina/fisiopatologia , Degeneração Retiniana/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Visão de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Progressão da Doença , Feminino , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Doença de Parkinson/fisiopatologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Acuidade Visual/fisiologiaRESUMO
Neurodegenerative diseases present a current challenge for accurate diagnosis and for providing precise prognostic information. Developing imaging biomarkers for multiple sclerosis (MS), Parkinson disease (PD), and Alzheimer's disease (AD) will improve the clinical management of these patients and may be useful for monitoring treatment effectiveness. Recent research using optical coherence tomography (OCT) has demonstrated that parameters provided by this technology may be used as potential biomarkers for MS, PD, and AD. Retinal thinning has been observed in these patients and new segmentation software for the analysis of the different retinal layers may provide accurate information on disease progression and prognosis. In this review we analyze the application of retinal evaluation using OCT technology to provide better understanding of the possible role of the retinal layers thickness as biomarker for the detection of these neurodegenerative pathologies. Current OCT analysis of the retinal nerve fiber layer and, specially, the ganglion cell layer thickness may be considered as a good biomarker for disease diagnosis, severity, and progression.
RESUMO
AIM: To evaluate structural changes in the retina and their correlation with visual dysfunction in patients with multiple sclerosis. METHODS: Patients with multiple sclerosis (n = 84) and healthy controls (n = 84) underwent structural evaluation of the retinal nerve fiber layer, and macular and ganglion cell layer thicknesses using Spectral domain optical coherence tomography (SD-OCT). All subjects underwent high and low contrast visual acuity, color vision (using the Farnsworth and L´Anthony desaturated D15 color tests), and contrast sensitivity vision using the Pelli Robson chart and CSV 1000E test. RESULTS: Macular, retinal nerve fiber layer, and ganglion cell layer thinning was observed in multiple sclerosis patients compared to healthy controls (p<0.05). High- and low-contrast visual acuity and contrast sensitivity vision at four different spatial frequencies were significantly reduced in comparison with healthy subjects (p<0.05). Macular, retinal nerve fiber layer and ganglion cell layer measurements correlated with high and low contrast visual acuity, and contrast sensitivity vision. Contrast sensitivity vision was the functional parameter that most strongly correlated with the structural measurements in multiple sclerosis and was associated with ganglion cell layer measurements. The L´Anthony color vision score (age-corrected color confusion index) was associated with macular measurements. CONCLUSIONS: Patients with multiple sclerosis had visual dysfunction that correlated with structural changes evaluated by SD-OCT. Macular and ganglion cell layer measurements may be good indicators of visual impairment in multiple sclerosis patients.
Assuntos
Esclerose Múltipla/diagnóstico por imagem , Retina/diagnóstico por imagem , Transtornos da Visão/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico , Tomografia de Coerência Óptica , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia , Acuidade VisualRESUMO
PURPOSE: To evaluate the thickness of the 10 retinal layers of patients with Alzheimer's disease (AD) using a new segmentation technology of the Spectralis optical coherence tomography (OCT) and to determine whether the thickness of specific layers predicts neurodegeneration or AD severity. METHODS: Patients with AD (n = 150) and age-matched healthy controls (n = 75) were analysed using the segmentation application prototype to automatically segment all retinal layers in a macular scan. Thicknesses of each layer were compared between patients with AD and controls, and between patients with disease durations of less than or at least 3 years. Associations between retinal layer thicknesses, disease duration and AD severity were evaluated. RESULTS: Patients with AD had reduced thickness in the retinal nerve fibre, ganglion cell, inner plexiform and outer nuclear layers (p < 0.05). The inner retinal layers were more affected in patients with long disease duration. Ganglion cell and retinal nerve fibre layer thicknesses were inversely correlated with AD duration and severity. Ganglion cell and inner plexiform layers thicknesses were predictive of axonal damage. CONCLUSIONS: The segmentation application revealed ganglion cell and retinal layer atrophy in patients with AD compared with controls, especially in the inner layers of patients with long disease duration. Ganglion cell layer reduction was associated with increased axonal damage and may predict greater disease severity.
Assuntos
Doença de Alzheimer/diagnóstico , Fibras Nervosas/patologia , Doenças Retinianas/diagnóstico , Células Ganglionares da Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Tomografia de Coerência Óptica , Acuidade Visual/fisiologiaRESUMO
Purpose: To assess the relationship between the retinal nerve fibre layer (RNFL) thickness and the frequency-doubling technology perimetry (FDT) outcome. Methods: Sixty-two healthy individuals and 72 glaucoma patients were prospectively selected. All participants underwent a reliable FDT and optical coherence tomography (OCT). Pearson correlations were calculated between the unlogged threshold values of FDT and RNFL thicknesses measured by OCT. Results: Mild to moderate correlations were found between a few points from FDT and RNFL thicknesses in the vertical axis. The nasal superior area of FDT and the RNFL thickness at the 7-o'clock position had the strongest correlation (0.434, p < 0.001). Conclusions: The poor agreement between FDT and OCT parameters suggests that both instruments assess different characteristics of glaucomatous optic neuropathy. The map obtained validates previously reported clinical findings and contributes to a better understanding of the structure-function relationship in glaucoma. © 2014 S. Karger AG, Basel.
RESUMO
OBJECTIVE: To evaluate the relationship between spectral-domain optical coherence tomography (OCT) and standard automated perimetry (SAP) in healthy and glaucoma individuals. METHODS: The sample comprised 338 individuals divided into 2 groups according to intraocular pressure and visual field outcomes. All participants underwent a reliable SAP and imaging of the optic nerve head with the Cirrus OCT. Pearson correlations were calculated between threshold sensitivity values of SAP (converted to linear scale) and OCT parameters. RESULTS: Mean age did not differ between the control and glaucoma groups (59.55 ± 9.7 years and 61.05 ± 9.4 years, resp.; P = 0.15). Significant differences were found for the threshold sensitivities at each of the 52 points evaluated with SAP (P < 0.001) and the peripapillary retinal nerve fiber layer (RNFL) thicknesses, except at 3 and 9 clock-hour positions between both groups. Mild to moderate correlations (ranging between 0.286 and 0.593; P < 0.001) were observed between SAP and most OCT parameters in the glaucoma group. The strongest correlations were found between the inferior RNFL thickness and the superior hemifield points. The healthy group showed lower and weaker correlations than the glaucoma group. CONCLUSIONS: Peripapillary RNFL thickness measured with Cirrus OCT showed mild to moderate correlations with SAP in glaucoma patients.
Assuntos
Glaucoma/patologia , Glaucoma/fisiopatologia , Pressão Intraocular , Fibras Nervosas/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
PURPOSE: We calculated and validated a linear discriminant function (LDF) for Fourier domain optical coherence tomography (OCT) to improve the diagnostic ability of retinal and retinal nerve fiber layer (RNFL) thickness parameters in the detection of Alzheimer's disease (AD). METHODS: We enrolled AD patients (n = 151) and age-matched, healthy subjects (n = 61). The Cirrus and Spectralis OCT systems were used to obtain retinal measurements and circumpapillary RNFL thickness for each participant. An LDF was calculated using all retinal and RNFL OCT measurements. Receiver operating characteristic (ROC) curves were plotted and compared among the LDF and the standard parameters provided by OCT devices. Sensitivity and specificity were used to evaluate diagnostic performance. A validating set was used in an independent population to test the performance of the LDF. RESULTS: The optimal function was calculated using the RNFL thickness provided by Spectralis OCT, using the 768 points registered during peripapillary scan acquisition (grouped to obtain 24 uniformly divided locations): 18.325 + 0.056 × (315°-330°) - 0.122 × (300°-315°) - 0.041 × (285°-300°) + 0.091 × (255°-270°) + 0.041 × (225°-240°) + 0.183 × (195°-210°) - 0.108 × (150°-165°) - 0.092 × (75°-90°) + 0.051 × (30°-45°). The largest area under the ROC curve was 0.967 for the LDF. At 95% fixed specificity, the LDF yielded the highest sensitivity values. CONCLUSIONS: Measurements of RNFL thickness obtained with the Spectralis OCT device differentiated between healthy and AD individuals. Based on the area under the ROC curve, the LDF was a better predictor than any single parameter.
Assuntos
Doença de Alzheimer/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Estudos de Casos e Controles , Estudos Transversais , Análise Discriminante , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e EspecificidadeRESUMO
PURPOSE: To evaluate the thickness of the 10 retinal layers in the paramacular area of Parkinson disease patients using a new segmentation technology of optical coherence tomography (OCT) to examine whether the thickness of specific layers predicts neurodegeneration or Parkinson disease severity. DESIGN: Observational prospective study. METHODS: Parkinson disease patients (n = 129) and age-matched healthy subjects (n = 129) were enrolled. The Spectralis OCT system was used to automatically segment all retinal layers in a parafoveal scan using the new segmentation application prototype. Mean thickness of each layer was calculated and compared between Parkinson disease patients and healthy subjects, and between Parkinson disease patients with disease durations of less than or at least 10 years. A correlation analysis was performed to evaluate the association between retinal layer thickness, duration of disease, and Parkinson disease severity. Logistic regression analysis was performed to determine the most sensitive layer for predicting axonal atrophy. RESULTS: Parkinson disease patients showed statistically significant reduced thickness in the retinal nerve fiber, ganglion cell, inner plexiform, and outer plexiform layers and increased thickness in the inner nuclear layer compared with healthy subjects (P < .05). The inner retinal layers were more affected in Parkinson disease patients with long disease duration. The ganglion cell layer thickness was inversely correlated with disease duration and Parkinson disease severity, and was predictive of axonal damage in Parkinson disease patients. CONCLUSIONS: The segmentation application of the Spectralis OCT revealed retinal layer atrophy in Parkinson disease patients, especially in the inner layers of patients with long disease duration. Ganglion cell layer reduction was associated with increased axonal damage.
Assuntos
Doença de Parkinson/diagnóstico , Neurônios Retinianos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Atrofia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia de Coerência Óptica , Acuidade VisualRESUMO
PURPOSE: To test the diagnostic ability of spectral domain optical coherence tomography for the detection of Parkinson disease using retinal nerve fiber layer and retinal thickness parameters. Retinal pigment epithelium produces levodopa. METHODS: Patients with Parkinson disease (n = 111) and healthy subjects (n = 200) were enrolled. The Spectralis optical coherence tomography was used to obtain retinal nerve fiber layer thickness and retinal measurements. Two linear discriminant functions (LDFs) were developed, one using retinal nerve fiber layer parameters and another using retinal thickness. A validating set was used to test the performance of both LDFs. Receiver operating characteristic curves were plotted and compared with the standard parameters provided by optical coherence tomography for both LDFs. Sensitivity and specificity were used to evaluate diagnostic performance. RESULTS: The Retinal LDF combines only retinal thickness parameters and provided the best performance: 31.173 + 0.026 × temporal outer - 0.267 × superior outer + 0.159 × nasal outer - 0.197 × inferior outer - 0.060 × superior inner + 0.049 × foveal thickness. The largest areas under the receiver operating characteristic curve were 0.902 for Retinal LDF. The Retinal LDF yielded the highest sensitivity values. CONCLUSION: Measurements of retinal thickness differentiate between subjects who are healthy and those with advanced Parkinson disease.
Assuntos
Fibras Nervosas/patologia , Doença de Parkinson/diagnóstico , Doenças Retinianas/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Idoso , Área Sob a Curva , Análise Discriminante , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Acuidade Visual/fisiologiaRESUMO
BACKGROUNDS/AIMS: To evaluate the effect of uncomplicated cataract phacoemulsification on the measurements of macular and retinal nerve fibre layer (RNFL) in healthy subjects using two spectral domain (SD) optical coherence tomography (OCT) instruments--Cirrus OCT (Zeiss) and Spectralis OCT (Heidelberg)--and to assess the reliability of the measurements obtained with these two devices before and after cataract surgery. METHODS: The study included 60 eyes of 60 healthy subjects (22 men and 38 women, 54-88 years of age) who underwent cataract phacoemulsification. One month before and one month after surgery, three repetitions of scans were performed using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments. The differences between RNFL and macular thickness measurements obtained in the two visits were analysed. Repeatability was evaluated by calculating the coefficient of variation (COV) for each of the parameters recorded and for each visit. RESULTS: The RNFL measurements obtained with the Cirrus and Spectralis OCT differed before and after surgery, and most of these differences were statistically significant (p<0.05). Macular thickness measurements using the Spectralis OCT were not significantly different between the two visits, whereas the differences found with the Cirrus OCT were statistically significant. The repeatability was better after surgical removal of the cataract, and the differences between COV in the two visits were significant with the Cirrus OCT. CONCLUSIONS: The presence of cataracts affects RNFL and macular measurements performed with SD-OCT. The repeatability of the images significantly improved after cataract phacoemulsification when using the Cirrus OCT.
Assuntos
Catarata/patologia , Facoemulsificação , Tomografia de Coerência Óptica/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentaçãoRESUMO
PURPOSE: To evaluate the effect of uncomplicated cataract phacoemulsification on macular and retinal nerve fiber layer (RNFL) thickness using two spectral-domain optical coherence tomography (OCT) instruments, Cirrus OCT and Spectralis OCT, in patients having non-insulin-dependent diabetes mellitus (NIDDM) without retinopathy, and to assess the reliability of the OCT measurements before and after cataract surgery. METHODS: The study included 35 eyes of 35 patients having NIDDM without retinopathy (20 men and 15 women, mean age 69.8 years, range, 48-80 years) who underwent cataract phacoemulsification. One month before and 1 month after surgery, visual acuity and three repetitions of scans using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments were performed. The differences between the two visits were analyzed by Student's t-test for paired samples. Repeatability of OCT measurements was evaluated by calculating the coefficients of variation for each of the parameters recorded and for each visit. RESULTS: RNFL thicknesses provided by Cirrus and Spectralis OCT and macular measurements provided by Cirrus OCT differed significantly between the two visits. Macular thicknesses provided by Spectralis OCT before and after surgery were not significantly different. OCT repeatability was better after surgery with lower coefficients of variation for scans performed after surgical removal of the cataract. CONCLUSIONS: The presence of cataracts affects RNFL and macular measurements performed with OCT in NIDDM patients without retinopathy. The repeatability of the images significantly improved after cataract phacoemulsification.