Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(8): 460, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39083185

RESUMO

OBJECTIVES: Evaluate the 5-year safety and efficacy of a narrow-diameter (3.0 mm) implant that was immediately provisionalized with a single crown in the maxillary lateral incisor or mandibular central or lateral incisor area. MATERIALS AND METHODS: An open, prospective, single-cohort, multicenter study was conducted, in which narrow-diameter implants were placed in fresh, healed extraction, or congenitally missing sites. All patients were required to meet strict criteria for immediate loading. The primary endpoints were marginal bone levels (MBL) and MBL changes (MBLC) from implant placement to 5-year follow-up. Secondary endpoints included cumulative 5-year survival and success rates, soft tissue health, and esthetic parameters. RESULTS: A total of 91 implants were placed in 77 patients. The mean MBL remained stable from the 1-year (- 0.79 ± 0.73 mm, n = 75) to 5-year (- 0.74 ± 0.87 mm, n = 65) follow-up. A marginal bone gain of 0.11 ± 0.83 mm was observed from the 1-year to 5-year follow-up. The cumulative 5-year survival rate was 96.5%, and the cumulative 5-year success rate was 93%. The clinical parameters, including the modified plaque index, modified sulcus bleeding index, Jemt's papilla index, and pink esthetic score improved throughout the 5-year study. CONCLUSIONS: The study demonstrated that narrow-diameter implants represent a safe and predictable treatment option for subjects suitable for immediate loading and with limited bone volume or limited inter-dental space. CLINICAL RELEVANCE: Narrow-diameter implants with immediate provisionalization can be considered for use to restore missing or damaged teeth with predictable functional and esthetic outcomes. This trial was registered with ClinicalTrials.gov (NCT02184845).


Assuntos
Coroas , Planejamento de Prótese Dentária , Estética Dentária , Carga Imediata em Implante Dentário , Humanos , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Implantes Dentários para Um Único Dente , Incisivo , Idoso
2.
Clin Oral Investig ; 26(4): 3593-3604, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34997359

RESUMO

OBJECTIVES: This open, single-cohort, multicenter, prospective study investigated the efficacy of immediately provisionalized tapered conical connection implant for single-tooth restorations in the anterior and premolar regions of the maxilla after 5 years of function. MATERIALS AND METHODS: All implants were placed in healed sites and immediately provisionalized. MBLs, soft-tissue parameters, and oral-health impact profile (OHIP) were evaluated at implant insertion, 6, 12, 24, 36, and 60 months. Paired Wilcoxon signed-rank tests and Kaplan-Meier survival analysis was used for statistical and implant survival/success analyses, respectively. RESULTS: Seventy-seven patients (81 implants) completed the 5-year follow-up. The 5-year cumulative survival and success rates were 97.8%, and the mean MBL change from implant insertion to 5 years was - 0.80 ± 1.13 mm. Optimal papilla index scores were observed at 90.1% of sites at 5 years compared with 32.8% of sites at insertion. Pink esthetic score, modified bleeding and plaque indices, and OHIP showed statistically significant improvement at the 5-year follow-up. CONCLUSIONS: Immediately provisionalized tapered conical connection implants promote marginal bone stability and excellent esthetic outcomes after 5 years of function. CLINICAL RELEVANCE: This treatment is a viable option for patients requiring immediately provisionalized single-tooth restorations in the esthetic zone and shows favorable long-term clinical outcomes, including marginal bone stability and excellent esthetics.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Planejamento de Prótese Dentária , Estética Dentária , Seguimentos , Humanos , Maxila/cirurgia , Estudos Prospectivos , Resultado do Tratamento
3.
Clin Oral Investig ; 23(4): 1877-1885, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30225678

RESUMO

OBJECTIVES: This multicenter prospective clinical trial investigated immediately provisionalized, anodized, conical connection, tapered implants with platform shifting in maxillary anterior and premolar sites. MATERIALS AND METHODS: Patients requiring single-tooth implant-supported restorations in maxillary anterior and premolar sites were enrolled. Implants were immediately provisionalized and evaluated at insertion, 6 months, and annually thereafter. Outcome measures were marginal bone level change (ΔMBL), cumulative survival rate (CSR), and success rate, soft-tissue parameters, and oral health impact profile (OHIP). ΔMBL and Pink Esthetic Score were analyzed using Wilcoxon signed-rank tests. CSR was calculated using life table analysis. Other soft-tissue parameters were analyzed using sign tests. RESULTS: Of 94 enrolled patients (99 implants), 84 (88 implants) attended the 3-year follow-up. After an initial bone loss between implant insertion and 6 months (- 0.92 ± 1.23 mm), bone levels stabilized from 6 months to 3 years (0.13 ± 0.94 mm) with no significant change. The 3-year CSR was 98.9%, and the cumulative success rate was 96.9%. Papilla index scores of 2 or 3 were observed at 88.6% of sites at the 3-year visit compared with 32.8% at implant insertion. Improvements were observed for all other outcomes, including bleeding on probing, esthetics, plaque, and OHIP. CONCLUSIONS: This restorative protocol was associated with high primary stability, patient satisfaction, stable bone levels, and an overall improvement of the soft tissue outcomes over a 3-year period. CLINICAL RELEVANCE: The presented treatment is a viable option for single-tooth restorations of maxillary anterior teeth and premolars with successful short- to mid-long-term clinical outcomes.


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Adolescente , Adulto , Idoso , Dente Pré-Molar , Estética Dentária , Feminino , Seguimentos , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
4.
Oral Implantol (Rome) ; 5(4): 75-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23741600
5.
J Appl Biomater Biomech ; 7(1): 23-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20740435

RESUMO

PURPOSE: The research presented is aimed at the characterization of the mechanical resistance of an innovative system of an abutment-fixture connection in dental implants. This innovative connection system is composed of a triangular prismatic connection designed to improve the anti-rotational properties of the implant, and to seal any gap between the abutment and the fixture. METHODS: The mechanical performances of the dental implant system were investigated by means of static mechanical strength tests, which allowed the identification of the bending, torque and compression resistance of the system, and fatigue testing, according to the practice standard - ISO 14801. Surface finishing was also analyzed by scanning electron microscopy (SEM) observations and laser profilometry tests. RESULTS: The analyzed implant exhibited good mechanical characteristics, both in static and in fatigue tests. Moreover, the gap between the fixture and the abutment detected by SEM analyses was restricted, both before and after fatigue tests, being approximately 4 mum in the worst case observed: this is representative of optimal sealing against fluid infiltration. CONCLUSIONS: The modification of traditional dental implants with the introduction of a triangular prismatic connection system not only allowed the implant rotational stability and sealing performances to increase, but also conferred optimal mechanical resistance to the implant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...