Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Catheter Cardiovasc Interv ; 93(6): E343-E345, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28544381

RESUMO

Impella (Abiomed, Danvers, MA) is an effective option for emergent treatment of critical refractory cardiogenic shock. However, in patients who have inadequate peripheral arterial access, Impella for left ventricular support sometimes requires surgical access, leading to disadvantages for emergent procedures or invasiveness for very sick patients. In addition, Impella for right ventricular support was recently reported to contribute to the management of severe biventricular dysfunction. In this report, we describe a case of refractory cardiogenic shock in a patient with inadequate vascular access who was treated with biventricular Impella via venous and caval-aortic access under conscious sedation. This technique can be used as a bridge to surgical ventricular assist device or heart transplantation. © 2017 Wiley Periodicals, Inc.


Assuntos
Cateterismo Periférico , Veia Femoral , Coração Auxiliar , Implantação de Prótese/instrumentação , Choque Cardiogênico/terapia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Sedação Consciente , Feminino , Humanos , Desenho de Prótese , Punções , Recuperação de Função Fisiológica , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 11(2): 107-115, 2018 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-29348004

RESUMO

OBJECTIVES: This study sought to investigate predictors and safety of next-day discharge (NDD) after transcatheter aortic valve replacement (TAVR). BACKGROUND: Information about predictors and safety of NDD after TAVR is limited. METHODS: The study reviewed 663 consecutive patients who underwent elective balloon-expandable TAVR (from July 2014 to July 2016) at our institution. We first determined predictors of NDD in patients who underwent minimalist transfemoral TAVR. After excluding cases with complications, we compared 30-day and 1-year outcomes between NDD patients and those with longer hospital stay using Cox regression adjusting for the Predicted Risk of Mortality provided by the Society of Thoracic Surgeons. The primary endpoint was the composite of mortality and readmission at 1 year. RESULTS: A total of 150 patients had NDD after TAVR and 210 patients had non-NDD. Mean age and the Society of Thoracic Surgeons Predicted Risk of Mortality were 80.7 ± 8.8 years and 6.6 ± 3.7%, respectively. Predictors of NDD were male sex (odds ratio [OR]: 2.02; 95% confidence interval [CI]: 1.28 to 3.18), absence of atrial fibrillation (OR: 1.62; 95% CI: 1.02 to 2.57), serum creatinine (OR: 0.71; 95% CI: 0.55 to 0.92), and age (OR: 0.95; 95% CI: 0.93 to 0.98). As expected, 84% of patients with complications had non-NDD. After excluding cases with complications, there was no difference in hazard rates of the 30-day composite outcome between NDD and non-NDD (hazard ratio: 0.62; 95% CI: 0.20 to 1.91), but the hazard of the composite outcome at 1 year was significantly lower in the NDD group (hazard ratio: 0.47; 95% CI: 0.27 to 0.81). This difference in the composite outcome can be explained by the lower hazard of noncardiovascular related readmission in the NDD group. CONCLUSIONS: Factors predicting NDD include male sex, absence of atrial fibrillation, lower serum creatinine, and younger age. When compared with patients without complications with a longer hospital stay, NDD appears to be safe, achieving similar 30-day and superior 1-year clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Tempo de Internação , Alta do Paciente , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Biomarcadores/sangue , Comorbidade , Creatinina/sangue , Feminino , Nível de Saúde , Hemodinâmica , Humanos , Masculino , Readmissão do Paciente , Segurança do Paciente , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 90(4): 690-700, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471092

RESUMO

BACKGROUND: Though several anatomical characteristics have been reported separately as risk factors for paravalvular leak (PVL) and landing zone (LZ) complications after transcatheter aortic valve replacement (TAVR), multivariate risk models are needed. METHODS: Patients that underwent balloon-expandable TAVR with multidetector cardiac computed tomography (MDCT) sizing were studied. MDCT images were analyzed and the association between anatomical factors and ≥mild PVL, ≥moderate PVL, and LZ complications (annular rupture, requirement of new permanent pacemaker, and coronary obstruction) was determined, and subsequently competing predictive models were developed and validated. RESULTS: A total of 316 consecutive TAVR patients were included. Median age was 82.0 years (74.0-87.0) and STS score was 8.3% (5.4-10.9). Factors associated with ≥mild PVL included TAVR with Sapien/Sapien XT vs. Sapien 3 (OR = 2.50, 95% CI = 1.24-5.07), LVOT nontubularity (OR = 1.02, 95% CI = 1.01-1.04), LZ calcification (OR = 1.01, 95% CI = 1.00-1.01), and low cover index (OR = 0.94, 95% CI = 0.91-0.96). Factors associated with LZ complications included LZ calcification (OR = 1.01, 95% CI 1.00-1.01), leaflet asymmetry (OR = 1.01, 95% CI 1.01-1.02), and cover index (OR = 1.09, 95% CI 1.03-1.14). Predictive models for ≥mild PVL (AUC = 0.71, 95% CI = 0.66-0.77), ≥moderate PVL (AUC = 0.75, 95% CI = 0.65-0.84), and LZ complications (AUC = 0.77, 95% CI = 0.67-0.87) were created using procedural details and anatomical data from the MDCT. Clinical variables were not included as they were poorly correlated with the occurrence of PVL and LZ complications. For each outcome, the area under the curve (AUC) of the multivariate model was superior to the model consisting only of individual factors. CONCLUSIONS: A model using procedural/anatomical characteristics derived from MDCT predicts ≥mild PVL, ≥moderate PVL, and LZ complications post-TAVR. Incorporation of anatomical risks into clinical practice may help stratify patients before TAVR. © 2017 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Feminino , Próteses Valvulares Cardíacas , Humanos , Modelos Logísticos , Masculino , Tomografia Computadorizada Multidetectores , Análise Multivariada , Razão de Chances , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
5.
JACC Cardiovasc Interv ; 10(5): 500-507, 2017 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-28279317

RESUMO

OBJECTIVES: The aim of this study was to compare outcomes of transcatheter intervention (TI) versus surgical intervention (SI) for paravalvular leak (PVL). BACKGROUND: Data comparing the treatment of PVL with TI and SI are limited. METHODS: A retrospective cohort study was conducted comparing baseline characteristics, procedural details, and 1-year survival in consecutive patients who underwent TI or SI for moderate or greater PVL from 2007 to 2016. The primary outcome was a composite of death, reintervention for PVL, or readmission for congestive heart failure-related symptoms at 1 year. RESULTS: Of 114 patients, 56 underwent TI and 58 underwent SI. PVL locations were mitral, aortic, and pulmonary in 69 (60.5%), 39 (34.2%), and 6 (5.3%) patients, respectively. At baseline, TI patients were older (age 71 vs. 62 years; p = 0.010) and had fewer cases of active endocarditis (0.0% vs. 25.9%, p < 0.001) than SI patients. The TI group had a shorter post-operative stay (4 vs. 8 days; p < 0.001), a shorter intensive care unit stay (0 vs. 3 days; p < 0.001), and fewer readmissions at 30 days (8.9% vs. 25.9%; p = 0.017). There were no differences in the primary endpoint (TI 33.9% vs. SI 39.7%; p = 0.526) or 1-year survival (TI 83.9% vs. SI 75.9%; p = 0.283) between groups. CONCLUSIONS: In this study, TI for PVL closure had comparable 1-year clinical outcomes with SI, even after adjusting for differences in baseline characteristics, with less in-hospital morbidity and 30-day rehospitalization. Although further study is needed, these findings support the increased implementation of TI for PVL closure at experienced institutions.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valvas Cardíacas/cirurgia , Complicações Pós-Operatórias/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Centros Médicos Acadêmicos , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Feminino , Georgia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 89(4): 775-780, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27862901

RESUMO

OBJECTIVES: To compare outcomes after minimalist and standard transfemoral transcatheter aortic valve replacement (TF-TAVR) in patients with severe chronic obstructive pulmonary disease (COPD). BACKGROUND: TF-TAVR is increasingly performed with conscious sedation and transthoracic echocardiography guidance (minimalist). The safety/efficacy of this technique in patients with severe COPD is unknown. METHODS: We compared demographics, 30-day outcomes and 1-year survival of patients with severe COPD (FEV1% ≤50) who underwent minimalist vs. standard TF-TAVR between 2008 and 2015 at our institution. RESULTS: Of 88 patients with severe COPD, 46 underwent minimalist and 42 underwent standard TF-TAVR. There were no differences on baseline characteristics, except for more history of coronary artery bypass grafting (45.5% vs. 20.6%, P = 0.03) and less history of cerebrovascular disease (16.7% vs. 45.5%, P = 0.03) in the standard TF-TAVR. Seventeen minimalist TF-TAVR patients (41.0%) were transferred directly to the general medical ward with telemetry monitoring (without ICU stay); all standard TF-TAVR patients went to the ICU. Minimalist TF-TAVR patients had shorter procedure time (97 vs. 129 min, P < 0.001), ICU time (21.8 vs. 29.8 hr, P = 0.001) and length of stay (2 vs. 5 days, P = 0.001). There were no differences in procedure complications and 30-day mortality between groups. In our multivariate analysis, minimalist TF-TAVR (HR 0.28, 95%CI 0.08-0.97) and previous coronary revascularization (HR 0.24, 95%CI 0.09-0.65) were associated with increased 1-year survival. In contrast, moderate paravalvular leak (HR 7.73, 95%CI 1.94-30.84) was associated with decreased 1-year survival. CONCLUSION: In patients with severe COPD, Minimalist TF-TAVR results in less resource utilization and improved 1-year survival compared to standard approach. Our findings should be validated in a larger cohort of patients with severe COPD. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Doença Pulmonar Obstrutiva Crônica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Ecocardiografia Transesofagiana , Feminino , Artéria Femoral , Seguimentos , Georgia/epidemiologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/mortalidade , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
7.
Int J Cardiol ; 223: 444-449, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27544602

RESUMO

BACKGROUND: Neutrophil-lymphocyte (NLR) and platelet-lymphocyte ratios (PLR) mark systemic inflammation. Patients with high NLR and PLR have worse cardiovascular disease and outcomes. We assessed the role of these ratios in predicting outcomes after transcatheter aortic valve replacement (TAVR). METHODS: The association between NLR and PLR with baseline characteristics, 30-day outcomes, and 1-year readmission/survival was determined in patients that underwent TAVR between 2007 and 2014 and had baseline complete blood count with differential. A subgroup analysis determined the association between change in NLR and PLR (discharge-baseline) and 1-year outcomes. RESULTS: In 520 patients that underwent TAVR, a higher NLR (p=0.01) and PLR (p=0.02) were associated with a higher STS-PROM score, and with increased occurrence of the 30-day early-safety outcome (by VARC-2), even after adjusting for STS-PROM score, valve generation (Sapien vs. Sapien XT), and access (transfemoral vs. non-transfemoral) (NLR: OR 1.29, 95% CI 1.04-1.61; PLR: OR 1.27, 95% CI 1.01-1.60) but not with 1-year readmission or survival. In our subgroup analysis (N=294), change in PLR was not associated with the 1-year outcomes but a high change in NLR was associated with worse 1-year survival/readmission and 1-year survival, even after adjusting for STS-PROM score, valve generation and access (HR 1.22, 95% CI 1.04-1.44 and HR 1.26, 95% CI 0.99-1.6, respectively). CONCLUSIONS: NLR and PLR correlate with surgical risk. An elevated NLR and PLR were associated with the occurrence of 30-day adverse outcomes, similar to the STS-PROM score. A high variation of NLR from baseline to discharge may help stratify patients that underwent TAVR in addition to traditional risk factors.


Assuntos
Estenose da Valva Aórtica/cirurgia , Plaquetas/patologia , Linfócitos/patologia , Neutrófilos/patologia , Complicações Pós-Operatórias/sangue , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/mortalidade , Feminino , Seguimentos , Humanos , Contagem de Leucócitos , Masculino , Contagem de Plaquetas , Complicações Pós-Operatórias/mortalidade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
8.
Cardiovasc Ultrasound ; 12: 40, 2014 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-25277882

RESUMO

BACKGROUND: Diastolic wall strain (DWS), defined using posterior wall thickness (PWT) measurements from standard echocardiographic images (DWS = [PWT(systole)-PWT(diastole)]/PWT(systole)), has been proposed as a marker of left ventricular (LV) diastolic stiffness. However, the equation for DWS is closely related to systolic radial strain, and whether DWS is associated with abnormal cardiac mechanics (reduced systolic strains and diastolic tissue velocities) is unknown. We sought to determine the relationship between DWS and systolic and diastolic cardiac mechanics. METHODS: We calculated DWS and performed speckle-tracking analysis in a large population- and family-based study (Hypertension Genetic Epidemiology Network [HyperGEN]; N=1907 after excluding patients with ejection fraction [EF] <50% or posterior wall motion abnormalities). We measured global longitudinal, circumferential, and radial strain (GLS, GCS, and GRS, respectively) and early diastolic (e') tissue velocities, and we determined the independent association of DWS with cardiac mechanics using linear mixed effects models to account for relatedness among study participants. We also prospectively performed receiver-operating characteristic (ROC) analysis of DWS for the detection of abnormal cardiac mechanics in a separate, prospective validation study (N=35). RESULTS: In HyperGEN (age 51 ± 14 years, 59% female, 45% African-American, 57% hypertensive), mean DWS was 0.38 ± 0.05. DWS decreased with increasing comorbidity burden (ß-coefficient -0.013 [95% CI -0.015, -0.011]; P<0.0001). DWS was independently associated with GLS, GCS, GRS, and e' velocity (adjusted P<0.05) but not LV chamber compliance (EDV20, P=0.97). On prospective speckle-tracking analysis, DWS correlated well with GLS, GCS, and GRS (R=0.61, 0.57, and 0.73, respectively; P<0.001 for all comparisons). C-statistics for DWS as a diagnostic test for abnormal GLS, GCS, and GRS were: 0.78, 0.79, and 0.84, respectively. CONCLUSIONS: DWS, a simple parameter than can be calculated from routine 2D echocardiography, is closely associated with systolic strain parameters and early diastolic (e') tissue velocities but not LV chamber compliance.


Assuntos
Módulo de Elasticidade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Biomarcadores , Diástole , Ecocardiografia/estatística & dados numéricos , Técnicas de Imagem por Elasticidade/estatística & dados numéricos , Feminino , Humanos , Hipertensão/epidemiologia , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Estresse Mecânico , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia
10.
Arch Intern Med ; 172(11): 864-71, 2012 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-22566489

RESUMO

BACKGROUND: Rapid activation of the cardiac catheterization laboratory for primary percutaneous coronary intervention (PCI) improves outcomes for ST-segment elevation myocardial infarction (STEMI), but selected emphasis on minimizing time to reperfusion may lead to a greater frequency of false-positive activations. METHODS: We analyzed consecutive patients referred for primary PCI for a possible STEMI at 2 centers from October 2008 to April 2011. "False-positive STEMI activation" was defined as lack of a culprit lesion by angiography or by assessment of clinical, electrocardiographic, and biomarker data in the absence of angiography. Clinical and electrocardiographic factors associated with false-positive activations were evaluated in a backward stepwise selection bootstrapped logistic regression model. RESULTS: Of 411 STEMI activations by emergency physicians, 146 (36%) were deemed to be false-positive activations. Structural heart disease and heart failure were the most common diagnoses among false-positive activations. Electrocardiographic left ventricular hypertrophy (adjusted odds ratio [AOR], 3.15; 95% CI, 1.55-6.40; P=.001), a history of coronary disease (AOR, 1.93; 95% CI, 1.04-3.59; P=.04), or prior illicit drug abuse (AOR, 2.67; 95% CI, 1.13-6.26; P=.02) independently increased the odds of false-positive STEMI activations. Increasing body mass index decreased the odds of a false-positive activation (AOR, 0.91; 95% CI, 0.86-0.97; P=.004), as did angina at presentation (AOR, 0.28; 95% CI, 0.14-0.57; P < .001). CONCLUSIONS: More than a third of patients referred for primary PCI from the emergency department did not have a STEMI. Multiple patient-level characteristics were significantly associated with an increased odds of false-positive STEMI activation.


Assuntos
Angioplastia Coronária com Balão , Tratamento de Emergência/métodos , Sistema de Condução Cardíaco/fisiopatologia , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Adulto , Idoso , Análise de Variância , Biomarcadores/sangue , Eletrocardiografia , Reações Falso-Positivas , Feminino , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Masculino , Anamnese , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Prevalência , Sistema de Registros , Fatores de Risco , Transtornos Relacionados ao Uso de Substâncias/complicações , Fatores de Tempo , Troponina I/sangue , Estados Unidos/epidemiologia
11.
Am J Cardiol ; 109(3): 327-31, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22078964

RESUMO

Early in the course of ST-segment elevation myocardial infarction (STEMI), therapies that may harm patients who develop left ventricular (LV) dysfunction, such as ß-blockers, are often administered. The investigators analyzed the ACTIVATE-SF database, a registry of consecutive STEMI activations presenting to 2 medical centers at the University of California, San Francisco. LV dysfunction was defined as an ejection fraction ≤40% on echocardiography. Of 211 patients included in the analysis, 66 (31%) had LV ejection fractions ≤40%. Patients with LV dysfunction were older (63 ± 15 vs 56 ± 13 years, p = 0.002). In multivariate regression models, decreased renal function (reference group, creatinine <1.0 mg/dl; adjusted odds ratio [AOR] creatinine >1.5 mg/dl 6.35, 95% confidence interval [CI] 1.66 to 24.31, p = 0.007), a history of coronary artery disease (AOR 3.12, 95% CI 1.26 to 7.71, p = 0.014), ST-segment elevation >2 mm on 12-lead electrocardiography (AOR 2.78, 95% CI 1.31 to 5.87, p = 0.008), and need for mechanical ventilation (AOR 3.98, 95% CI 1.41 to 11.19, p = 0.009) increased the odds of LV dysfunction. Inferior ST-segment elevations were associated with 88% decreased odds of LV dysfunction (AOR 0.12, 95% CI 0.06 to 0.35, p <0.001). A prediction score using these characteristics stratified patients into low-, intermediate-, and high-risk groups for LV dysfunction; positive likelihood ratios for LV dysfunction in these groups were 0.07, 1.14, and 4.93, respectively. In conclusion, 5 key predictors of in-hospital LV dysfunction after STEMI were identified; a risk score based on these predictors helps to quickly identify patients presenting with STEMI who are at the highest risk for developing significant LV dysfunction and could guide optimal therapeutic choices.


Assuntos
Diagnóstico Precoce , Eletrocardiografia , Ventrículos do Coração/fisiopatologia , Infarto do Miocárdio/complicações , Disfunção Ventricular Esquerda/diagnóstico , Intervalos de Confiança , Ecocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/etiologia
12.
JACC Cardiovasc Interv ; 3(1): 114-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20129579

RESUMO

OBJECTIVES: Our aim was to describe the use of balloon aortic valvuloplasty (BAV) to select proper transcatheter heart valve (THV) size. BACKGROUND: Transesophageal echocardiogram (TEE) measurement alone of the aortic annulus may not be adequate to select a THV size. BAV can more accurately size the aortic annulus. We report our experience using this strategy in patients undergoing THV implantation. METHODS: Twenty-seven patients underwent sizing of the aortic annulus by BAV and TEE. We implanted the minimal THV size that was greater than the annulus measured by BAV. RESULTS: The annulus measured by TEE was 21.3 +/- 1.6 mm and by BAV was 22.6 +/- 1.8 mm (p < 0.001). The number of balloon inflations was 2.7 +/- 0.7 (range 2 to 4), and the balloon sizes used were 22.0 +/- 1.8 mm (range 20 to 25 mm). Fourteen patients (52%) required upsizing of the initial balloon suggested by TEE; rapid pacing duration was 8 +/- 1.3 s (range 6 to 11 s). No change in aortic insufficiency or hemodynamic instability occurred with BAV. Fifteen patients (56%) received a 23-mm THV; 12 patients a 26-mm THV. No coronary occlusion, annular damage, or THV embolization occurred. Paravalvular leak was grade

Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco , Cateterismo , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo/instrumentação , Ecocardiografia Transesofagiana , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...