Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Magn Reson ; 271: 15-20, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27522542

RESUMO

The availability of compact, low-cost magnetic resonance imaging instruments would further broaden the substantial impact of this technology. We report highly sensitive detection of magnetic resonance using low-stress silicon nitride (SiNx) membranes. We use these membranes as low-loss, high-frequency mechanical oscillators and find they are able to mechanically detect spin-dependent forces with high sensitivity enabling ultrasensitive magnetic resonance detection. The high force detection sensitivity stems from their high mechanical quality factor Q∼10(6)[1,2] combined with the low mass of the resonator. We use this excellent mechanical force sensitivity to detect the electron spin magnetic resonance using a SiNx membrane as a force detector. The demonstrated force sensitivity at 300K is 4fN/Hz, indicating a potential low temperature (4K) sensitivity of 25aN/Hz. Given their sensitivity, robust construction, large surface area and low cost, SiNx membranes can potentially serve as the central component of a compact room-temperature ESR and NMR instrument having spatial resolution superior to conventional approaches.

2.
Phys Rev Lett ; 115(24): 246602, 2015 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-26705647

RESUMO

We present the measurement of ferromagnetic resonance (FMR-)driven spin pumping and three-terminal electrical spin injection within the same silicon-based device. Both effects manifest in a dc spin accumulation voltage V_{s} that is suppressed as an applied field is rotated to the out-of-plane direction, i.e., the oblique Hanle geometry. Comparison of V_{s} between these two spin injection mechanisms reveals an anomalously strong suppression of FMR-driven spin pumping with increasing out-of-plane field H_{app}^{z}. We propose that the presence of the large ac component to the spin current generated by the spin pumping approach, expected to exceed the dc value by 2 orders of magnitude, is the origin of this discrepancy through its influence on the spin dynamics at the oxide-silicon interface. This convolution, wherein the dynamics of both the injector and the interface play a significant role in the spin accumulation, represents a new regime for spin injection that is not well described by existing models of either FMR-driven spin pumping or electrical spin injection.

3.
Ultramicroscopy ; 111(8): 1360-5, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21864777

RESUMO

An iron filled carbon nanotube (FeCNT), a 10-40 nm ferromagnetic nanowire enclosed in a protective carbon tube, is an attractive candidate for a magnetic force microscopy (MFM) probe as it provides a mechanically and chemically robust, nanoscale probe. We demonstrate the probe's capabilities with images of the magnetic field gradients close to the surface of a Py dot in both the multi-domain and vortex states. We show the FeCNT probe is accurately described by a single magnetic monopole located at its tip. Its effective magnetic charge is determined by the diameter of the iron wire and its saturation magnetization 4πM(s) ≈ 2.2 × 10(4)G. A magnetic monopole probe is advantageous as it enables quantitative measurements of the magnetic field gradient close to the sample surface. The lateral resolution is defined by the diameter of the iron wire and the probe-sample separation.

4.
Rev Sci Instrum ; 80(8): 083704, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19725659

RESUMO

We have developed the variable temperature scanning force microscope capable of performing both magnetic resonance force microscopy (MRFM) and magnetic force microscopy (MFM) measurements in the temperature range between 5 and 300 K. Modular design, large scanning area, and interferometric detection of the cantilever deflection make it a sensitive, easy to operate, and reliable instrument suitable for studies of the dynamic and static magnetization in various systems. We have verified the performance of the microscope by imaging vortices in a Nb thin film in the MFM mode of operation. MRFM spectra in a diphenyl-picryl-hydrazyl film were recorded to evaluate the MRFM mode of operation.

5.
Phys Rev Lett ; 100(19): 197601, 2008 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-18518486

RESUMO

We report nanoscale scanned probe ferromagnetic resonance force microscopy (FMRFM) imaging of individual ferromagnetic microstructures. This reveals the mechanism for high spatial resolution in FMRFM imaging: the strongly inhomogeneous local magnetic field of the cantilever mounted micromagnetic probe magnet used in FMRFM enables selective, local excitation of ferromagnetic resonance (FMR). This approach, demonstrated here in individual permalloy disks, is straightforwardly extended to excitation of localized FMR modes, and hence imaging in extended films.

6.
J Magn Reson ; 154(2): 210-27, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11846579

RESUMO

The magnetic resonance force microscope (MRFM) provides a route to achieving scanned probe magnetic resonance imaging with extremely high spatial resolution. Achieving this capability will require understanding the force exerted on a microscopic magnetic probe by a spatially extended sample over which the probe is scanned. Here we present a detailed analysis of this interaction between probe and sample. We focus on understanding the situation where the micromagnet mounted on the mechanical resonator generates a very inhomogeneous magnetic field and is scanned over a sample with at least one spatial dimension much larger than that of the micromagnet. This situation differs quite significantly from the conditions under which most MRFM experiments have been carried out where the sample is mounted on the mechanical resonator and placed in a rather weak magnetic field gradient. In addition to the concept of a sensitive slice (the spatial region where the magnetic resonance condition is met) it is valuable to map the forces exerted on the probe by spins at various locations; this leads to the concept of the force slice (the region in which spins exert force on the resonator). Results of this analysis, obtained both analytically and numerically, will be qualitatively compared with an initial experimental finding from an EPR-MRFM experiment carried out on DPPH at 4 K.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...