Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
BMC Med Imaging ; 24(1): 215, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39143526

RESUMO

BACKGROUND: Due to the increasing incidence of ischaemic cerebrovascular diseases, the accurate assessment of internal carotid artery (ICA) stenosis is crucial for the development of treatment plans. This systematic review and meta-analysis aimed to evaluate the diagnostic value of computed tomography angiography (CTA) for severe ICAstenosis, thereby providing support for clinical decision-making and promoting diagnostic updates. METHODS: The PubMed, Embase, Cochrane Library, China National Knowledge Infrastructure (CNKI), Wanfang Database, VIP Database for Chinese Technical Periodicals (VIP), and Chinese Biomedical Literature (CBM) electronic databases were searched from inception to March 21, 2024, to identify publicly available research literature on the use of CTA to diagnose severe ICA stenosis. Literature screening, data extraction, and quality assessment were conducted based on the inclusion and exclusion criteria as well as the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) standards. Data analysis was performed using Stata 17.0 and Meta-Disc 1.4 software. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio of the included studies were calculated using Stata 17.0 software, and forest plots and summary receiver operating characteristic (SROC) curves were generated. The area under the curve (AUC) was calculated, and funnel plots were constructed to assess publication bias. RESULTS: A total of 16 studies with 2368 vascular segments were included. The meta-analysis revealed that the combined sensitivity and specificity of CTA for severe ICA stenosis were 0.93 (95% CI: 0.88 ~ 0.96) and 0.99 (95% CI: 0.96 ~ 1.00), respectively. The combined positive likelihood ratio and negative likelihood ratio were 92.0 (95% CI: 24.2 ~ 349.6) and 0.07 (95% CI: 0.04 ~ 0.13), respectively. The diagnostic odds ratio was 1302 (95% CI: 257 ~ 6606), and the AUC of the SROC curve was 0.98. The Deeks funnel plot suggested no publication bias among the included studies. CONCLUSION: CTA demonstrated high sensitivity and specificity for diagnosing severe ICA stenosis. Therefore, this study provided important evidence for the accurate diagnosis and treatment of severe ICA stenosis. However, there was considerable heterogeneity among the included studies, thus indicating the need for additional high-quality prospective studies to confirm the clinical applicability of CTA.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas , Angiografia por Tomografia Computadorizada , Sensibilidade e Especificidade , Humanos , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Artéria Carótida Interna/diagnóstico por imagem , Curva ROC , Índice de Gravidade de Doença
2.
Food Chem ; 424: 136367, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37207607

RESUMO

Hops extracts and their derivatives have many important biological activities, among them, excellent antibacterial and antioxidant properties make them a promising food preservative. However, poor water solubility limits their application in the food industry. This work aimed to improve the solubility of Hexahydrocolupulone (HHCL) by preparing solid dispersion (SD) and investigating the application of the obtained products (HHCL-SD) in actual food systems. HHCL-SD was prepared by solvent evaporation with PVPK30 as a carrier. The solubility of HHCL was dramatically increased to 24.72 mg/mL(25 ℃)by preparing HHCL-SD, much higher than that of raw HHCL (0.002 mg/mL). The structure of HHCL-SD and the interaction between HHCL and PVPK30 were analyzed. HHCL-SD was confirmed to have excellent antibacterial and antioxidant activities. Furthermore, the addition of HHCL-SD proved to be beneficial for the sensory, nutritional quality, and microbiological safety of fresh apple juice, hence prolonging its shelf-life.


Assuntos
Malus , Antioxidantes/farmacologia , Solventes/química , Antibacterianos/farmacologia , Solubilidade
3.
Antibiotics (Basel) ; 12(1)2022 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-36671237

RESUMO

Colistin is a last-line antibiotic against Gram-negative pathogens. However, the emergence of colistin resistance has substantially reduced the clinical effectiveness of colistin. In this study, synergy between colistin and capric acid was examined against twenty-one Gram-negative bacterial isolates (four colistin-susceptible and seventeen colistin-resistant). Checkerboard assays showed a synergistic effect against all colistin-resistant strains [(FICI, fractional inhibitory concentration index) = 0.02-0.38] and two colistin-susceptible strains. Time-kill assays confirmed the combination was synergistic. We suggest that the combination of colistin and capric acid is a promising therapeutic strategy against Gram-negative colistin-resistant strains.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...