Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros












Base de dados
Intervalo de ano de publicação
1.
J Oral Rehabil ; 43(1): 16-22, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26250478

RESUMO

Among different malocclusions, posterior cross-bite is thought to have a strong impact on the correct functioning of the masticatory system. The association between unilateral posterior cross-bite (UPCB) and temporomandibular joint (TMJ) clicking, however, remains still controversial. The aim of this study was to investigate whether the presence of UCPB during early adolescence increases the risk of reporting TMJ clicking after a long-term follow-up. A longitudinal survey design was carried out in a group of 12-year-old young adolescents, who were examined at baseline for TMJ clicking sounds and unilateral posterior cross-bite. After 10 years, 519 subjects could be reached by a telephone survey. Standardised questions were used to collect self-reported TMJ sounds and to determine whether participants had received an orthodontic treatment. Logistic regression analysis revealed a significant association between unilateral posterior cross-bite and subjectively reported TMJ clicking (odds ratio = 6·0; 95% confidence limits = 3·4-10·8; P < 0·0001). The incidence of TMJ clicking was 12%. At a ten-year follow-up, self-reports of TMJ clicking were significantly associated with the presence of UPCB at baseline, but not with the report of having received an orthodontic treatment. Within the limitation of this study, the presence of unilateral posterior cross-bite in young adolescents may increase the risk of reporting TMJ sounds at a 10-year follow-up. The provision of an orthodontic treatment, however, does not appear to reduce the risk of reporting TMJ sounds.


Assuntos
Luxações Articulares/fisiopatologia , Transtornos da Articulação Temporomandibular/fisiopatologia , Articulação Temporomandibular/fisiopatologia , Adolescente , Auscultação/métodos , Oclusão Dentária Central , Feminino , Seguimentos , Humanos , Incidência , Luxações Articulares/complicações , Masculino , Razão de Chances , Transtornos da Articulação Temporomandibular/complicações
2.
Med Phys ; 35(7): 3293-301, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18697554

RESUMO

Since its introduction the PinPoint (PTW-Freiburg) micro-ionization chamber has been proposed for relative dosimetry (output factors, depth dose curves, and beam profiles) as well as for determination of absolute dose of small high-energy photon beams. This paper investigates the dosimetric performance of a new design (type 31014) of the PinPoint ion chamber with a central aluminum electrode. The study included characterization of inherent and radiation-induced leakage, ion collection efficiency and polarity effect, relative response of the chamber, measurement of beam profiles, and depth dose curves. The 6 and 15 MV photon beams of a Varian 2100 C/D were considered. At the nominal operating voltage of 400 V the PinPoint type 31014 chamber was found to present a strong field size dependence of the polarity correction factor and an excess of the collected charge, which can lead to an underestimation of the collection efficiency if determined with the conventional "two-voltage" method. In comparison to the original PinPoint design (type 31006) the authors found for type 31014 chamber no overresponse to large-area fields if polarity correction is applied. If no correction is taken into consideration, the authors found the chamber's output to be inaccurate for large-area fields (0.5% accuracy limited up to the 12 x 12 and 20 x 20 cm2 field for the 6 and 15 MV beams, respectively), which is a direct consequence of the stem and polarity effects due to the chamber's very small sensitive volume (0.015 cc) and cable irradiation. Beam profiles and depth dose curves measured with type 31014 PinPoint chamber for small and medium size fields were compared to data measured with a 0.125 cc ion chamber and with high-resolution Kodak EDR2 films. Analysis of the penumbra (80%-20% distance) showed that the spatial resolution of type 31014 PinPoint ion chamber approaches (penumbra broadening < or = 0.6 mm) EDR2 film results.


Assuntos
Alumínio/química , Íons , Fótons , Radiometria/métodos , Radioterapia de Intensidade Modulada/instrumentação , Calibragem , Eletrodos , Desenho de Equipamento , Humanos , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Filme para Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...